VariTrans B The world s first 3-port standard signal isolator in a 6-mm modular housing.

Similar documents
VariTrans P The Problem The variety of tasks results in a large number of different devices.

Standard-Signal Isolation Amplifiers. VariTrans A 21000

VariTrans A The specialist for ±10 V and ±20 ma. With calibrated range selection and broad-range power supply.

WG 20. The WG 20 achieves an extraordinarily. accuracy for hazardous-area. applications.

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P 42000

Signal Doublers. VariTrans A 20300

VariTrans P Standard-Signal Isolators

SensoTrans DMS A 20220

SensoTrans DMS P 32200

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

MINI MCR-SL-UI-2I-NC. Extract from the online catalog. Order No.:

SITOP 3-phase 24 V DC, 20 to 40 A

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description

SITOP in the SIMATIC Design

MINI MCR-SL-CVS NC

MINI MCR-SL-PT100-UI-200

Contact protection relay

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

MINI MCR-SL-PT100-UI(-SP)(-NC)

Alarm Unit DG 3200 Control And Monitor Standard Signals

Extract from the online catalog

QUINT-PS AC/24DC/10

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

QUINT-PS/ 1AC/24DC/ 5

The Art of Measuring. Compact Transmitter with Modbus Interface. MemoRail Modbus

MINI MCR-SL-UI-2I(-SP)(-NC)

RTU500 series Data Sheet Power Supply CP-E 24/2.5

Indicators. Hazardous-Area Indicators. 830 X R Loop-Powered 16 Process Indicator. 830 X S1 Loop-Powered 16 Process Indicator

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

Extract from the online catalog

Power supply CP-C 24/5.0

Article No. 6GK59230PS003AA2 6GK59240PS001AA2 Product Name. Power Supply SCALANCE PS924 PoE Input: 120/230V AC; Output: 54V/ 1.

PHOENIX CONTACT - 07/2006

Process Analysis Systems. Stratos Pro A4 MSPH/MSPH. Chem Energy Pharm Food Water. Connection

Connection of OXY module with oxygen sensor (SE 706, Mettler Toledo InPro 6800, Hamilton Oxyferm) Model used: Stratos Pro A401N OXY/ V AC/DC

Power Supply HARTING pcon

SIPLUS S7-200 PS 203. Overview

Intrinsically Safe Barriers

MACX MCR-SL-(2)I-2)I-ILP(-SP)

4 â Active barrier RN221N with optional HART diagnosis. Technical Information

SITOP power supply. LOGO!Power. Overview. Safety instructions. Description, device design, dimension drawing. Mounting/removal 3

Assembly. Front view. LED yellow/red: Status output Ι/ Fault signal Function. Switch Power Rail

Power supply CP-E 48/1.25 Primary switch mode power supply

RMCN22BD Analog Converter ma - for Zelio Analog

SITOP modular 1ph/2ph. SITOP power supply. SITOP modular 1ph/2ph. Overview. Safety instructions. Description, device design, dimension drawing 2

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

Controlesta RCO-Compact

MINI-DC-UPS/12DC/4. Extract from the online catalog. Order No.:

M-series Intrinsically Safe I/O

Stratos Pro A4 PH. Connection

MODEL 9250 Preliminary data sheet

Power supply CP-E 24/0.75 Primary switch mode power supply

Power Supply HARTING pcon

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

PHOENIX CONTACT - 05/2007

Transducers for Pt-100/1000, Resistors

SR2A201BD compact smart relay Zelio Logic - 20 I O - 24 V DC - no clock - display

PI-EX-ME-2NAM/COC-24VDC

RAD-DAIO6-IFS. I/O extension module, 1 analog input/output, 2 digital wide-range inputs/outputs. INTERFACE Data sheet.

MINI MCR-2-U-I4(-PT) 3-way signal conditioner. Data sheet. 1 Description

TU531, TU532 Terminal Unit

MACX MCR-EX-SD LP(-SP)

Operating instructions. Standstill monitor A / / 2011

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

AI531 Analog Input Module

SR2B121BD compact smart relay Zelio Logic - 12 I O - 24 V DC - clock - display

DeltaV Bulk Power Supplies

TRIO-PS/1AC/24DC/20. Extract from the online catalog. Order No.:

STEP-PS/1AC/24DC/1.75

SR2B202BD compact smart relay Zelio Logic - 20 I O - 24 V DC - clock - display

PHOENIX CONTACT - 12/2007

The Art of Measuring. Compact. Cost-efficient. Digital. Plug & Measure with the new analyzers for Memosens. MemoRail

ETD-BL-1T-OFF-CC- 10S

PI-EX-ME-2NAM/COC-120VAC

AO523 Analog Input Module

Bargraph for quick range overview The digital indicators provide a bargraph in addition to the digital display. This gives you all information

itemp TMT180 Technical information

Power supply CP-E 24/10.0 Primary switch mode power supply

DS5000-IBFS. 5kA rms - 8kA DC Fluxgate current transducer. Features. Description. Application. Precision Innovation /

SITOP PSU8600 power supply system

Operating Instructions Differential Pressure Transducer PS27

RM35LM33MW liquid level control relay RM35-L V AC/DC

DeltaV Bulk Power Supplies

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

AX522 Analog Input/Output Module

LED Driver Linear / area fixed output

LED Driver Linear / area fixed output

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

PSI-MOS-RS422/FO 850 T

SITOP modular 1ph/2ph. SITOP power supply. SITOP modular 1ph/2ph. Overview. Safety instructions. Description, device design, dimension drawing 2

ABL1REM24100 regulated SMPS - single phase V input - 24 V output W

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

LOGO!Power. Power supply. LOGO!Power. Overview. Safety instructions 1. Description, device design, dimension drawing. Mounting/disassembly

Switched-Mode Power Supplies. 5, 12, 18, 48 VDC Output

TF501, TF521 Terminal Bases

Millenium 3. General Characteristics. General environment characteristics for CB, CD, XD, XR and XE product types

ABB i-bus KNX Analogue Input, 4-fold, MDRC AE/S , 2CDG110190R0011

JUMO mtron T Measuring, Control, and Automation System

Transcription:

Standard-Signal Isolation Amplifiers The world s first 3-port standard signal isolator in a 6-mm modular housing. The Task Isolation and, if required, conversion of 0... 20 ma, 4... 20 ma, and 0... 10 V standard signals. If space and budget are limited, there could still be difficulties when it comes to selecting a suitable isolator despite the standard transmission requirements. The Problems Up to now, the only way of reducing costs substantially was to opt for low quality products. As a large number of different signals also required a large number of isolators, this also led to considerable inventory costs. The Solution With its extremely compact design and low self-heating, the new standard-signal isolator from Knick sets new standards. The Vari- Trans B 10000 is available with nine selectable, calibrated ranges or as one of eight different fixed setting variants. The price is extremely attractive in all cases. The Housing Measuring only 6 mm, the closed modular housing of the allows up to 163 active isolation amplifiers per meter of mounting rail. A pluggable cross-connection to supply power enables quick and therefore inexpensive mounting. The Advantages In spite of the reduced space, the VariTrans B 10000 provides true 3-port isolation between the input, output and power supply to prevent parasitic voltages. The Technology Analog signal processing with transformer-based isolation ensures excellent signal transmission. Input and output ranges are easily selected using DIP switches. 74

For up-to-date information, please visit www.knick.de Isolation Amplifiers Indicators Process Analytics Portable Meters Laboratory Meters Sensors Fittings The Facts Safety in the smallest of spaces 3-port isolation in a 6-mm housing Space-saving installation No ventilation clearances required since there is no significant heat development Attractive price One of the most cost-effective quality isolators on the market Long service life Extremely low failure rate (MTBF of 440 years) due to reduced self-heating Good accuracy Exemplary signal transmission for standard applications Low-cost installation Pluggable cross-connections allow for easy and extremely efficient connection of the power supply to several units 8 fixed-range models if range shifting is to be avoided 3-port isolation Prevention of incorrect measurements caused by potential differences Simple configuration DIL switches accessible from outside 5-year warranty Warranty 5 years! Warranty Defects occurring within 5 years from delivery date shall be remedied free of charge at our plant (carriage and insurance paid by sender). Calibrated range selection No complicated calibration or adjusting 75

Standard-Signal Isolation Amplifiers Product Line Device Input Output Order No. with calibrated switching of input and output B 10000 F0 with fixed settings B 10016 F0 B 10017 F0 B 10018 F0 B 10026 F0 B 10016 F0 B 10028 F0 B 10036 F0 B 10037 F0 B 10038 F0 Cross-connections Pluggable cross-connection for looping through of power supply for up to 41 power supply connections of, splittable ZU 0542 24 V DC Specifications Input data Inputs calibrated switching or fixed setting (see product line) Input resistance Current input: voltage drop < 0.1 V at 20 ma, approx. 350 mv for open current output or power failure Voltage input: approx. 100 kohms Overload capacity Current input: < 100 ma Voltage input: voltage limited to 30 V by suppressor diode, max. permitted continuous current: 3 ma Output data Outputs calibrated switching or fixed setting (see product line) Load With output current: 10 V ( 500 ohms at 20 ma) With output voltage: 1 ma ( 10 kohm at 10 V) Offset Residual ripple < 20 µa or < 10 mv < 10 mv rms 76

For up-to-date information, please visit www.knick.de Isolation Amplifiers Indicators Process Analytics Portable Meters Laboratory Meters Sensors Fittings Specifications (continued) Transmission behavior Gain error 0.3 % full scale Additional error for live-zero operation 20 μa or 10 mv Cutoff frequency >100 Hz, 3 db Temperature coefficient < 0.01 %/K full scale Average TC in the specified operating temperature range 0 +55 C, reference temperature 23 C 24 V DC (± 15 %), approx. 0.6 W The power supply can be routed from one device to another via cross-connectors. Isolation Galvanic isolation Test voltage Working voltage (basic insulation) 3-port isolation between input, output and power supply 0.51 kv AC Up to 100 V AC/DC across all circuits with overvoltage category II and pollution degree 2 to EN 61010 Part 1. For applications with high working voltages, ensure there is sufficient spacing or isolation from neighboring devices and protection against electric shocks. Standards and approvals EMC Product family standard: EN 61326 Emitted interference: Class B Immunity to interference: Industry Slight deviations are possible during interference. Approval Explosion protection culus Listed, File No. E340287, E308146, E340288 Standard: UL 61010-1 and CAN/CSA C22.2 No. 61010-1 Europe: II 3G Ex na IIC T6 Gc X USA: Class I Div.2 GRP A,B,C,D T6 Class I Zone 2 AEx na IIC T6 Canada: Class I Zone 2 Ex na IIC T6 XClass I Div.2 GRP A,B,C,D T6 Further data MTBF Approx. 440 years Mean Time Between Failures MTBF according to EN 61709 (SN 29500) Requirements: stationary operation in well-kept rooms, average ambient temperature 40 C, no ventilation, continuous operation Ambient temperature Operation: 0 +55 C Transport and storage: 40 +85 C Design Modular housing with screw terminals, 6.1 mm wide See dimension drawings for further measurements Ingress protection IP 20 Mounting For 35-mm mounting rail according to EN 60715 See dimension drawing for conductor cross-section Weight Approx. 50 g 77

Standard-Signal Isolation Amplifiers Block Diagram + Input 0/ Z 30 Z 30 + Output 0/ + 24 V DC Typical Applications Potential isolation for safe connection of the measurement signals to the processing electronics e.g. C, bar 0/ e.g. PLC, PCS Signal conversion e.g. to convert voltage signals into current signals for interference-free signal transmission over long distances Voltage output e.g. indicator, PLC, PCS 78

For up-to-date information, please visit www.knick.de Isolation Amplifiers Indicators Process Analytics Portable Meters Laboratory Meters Sensors Fittings Application Examples (continued) Load increase e.g. for measuring signals with low load capability Current output e.g. C, bar max. load 50 Ω, e. g. PLC R I = 5 ohms max. load 500 Ω Dimension Drawings and Terminal Assignments 6.1 90 Terminal assignments 1 Input + 2 Input 3 4 + 5 Output 6 Output + 87.9 86.9 Conductor cross-sections: single wire 0.5 2.5 mm 2 stranded wire 0.5 2.5 mm 2 with ferrule 0.5 2.5 mm 2 97.8 All dimensions in mm 79