Foot switch. Installation, operation and maintenance manual

Similar documents
Telesmart TXG. Telescopic pillar. Installation, operation and maintenance manual

Ecomag. Linear Actuator. Installation, operation and maintenance manual

Operating instructions for AX5801. TwinSAFE drive option card for the AX5000 servo drive. Version: Date:

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

PTB 01 ATEX 2064 U, IECEx PTB U. Example / Beispiel / Exemple: Type Operating Instructions

PTB 01 ATEX Example / Beispiel / Exemple. Type Operating Instructions

Installation manual plugs and connectors with screw connection (16/32 A)

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

Operating instructions. Standstill monitor A / / 2011

Product and functional description

ETAM3 XETK/FETK ECU Adapter, SAMTEC FFSD - SAMTEC SFM (10fc - 10fc), 0m11 User s Guide

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

SINAMICS. SINAMICS G120P dv/dt filter plus Voltage Peak Limiter. Safety information 1. General. Mechanical installation. Electrical installation 4

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

Overview of types. Technical data

Operating and Installation Manual. EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage

Operating Instructions

Flow Sensor SONOFLOW CO.55

Dialock DT Lite. Operating instructions...2. Operating instructions

C9900-P223 and C9900-P224

Children s sing along cassette player

Explosion proof UL certified VoIP telephone. FernTel IP Z2 UL. Tabletop unit. Manual FHF BA /12

BVS 17 ATEX E 117 X / IECEx BVS X Types 3320, 3321, 3323, 3360, 3361, 3363 AE3320, AE3321, AE3323, AE3360, AE3361, AE3363

LED LIGHT PANEL QUADRANT SMD

Type Quickstart (from device Version 2)

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions

English. Operating Manual. Conductive point level switch MLR120. Retain for later reference. Companies / brands of GHM

Installation- and Operating instructions for CU Port USB 2.0 Hub. Version: 1.3 Date:

CMC III Universal Sensor

Products no longer available

Documentation EM2042. Sixteen Channel Digital Output Module with D-Sub Connector. Version: Date:

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

Portable Sampler MAXX TP5 W / P / C

IPCB42501 / IPCB42551

Signal processor MS96 for flow sensors MS96-11EX0-R/230VAC

BVS 17 ATEX E 117 X / IECEx BVS X Types 3320, 3321, 3323, 3360, 3361, 3363 AE3320, AE3321, AE3323, AE3360, AE3361, AE3363

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

LED LINE SMD LIGHTBAR

Content. Product Description

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

SIWAREX JB Aluminum Housing. Instruction Manual Edition 03/2006

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern

Installation- and Operating instructions for CU Port USB 3.0 Hub. Version: 1.1 Date:

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA. GE Critical Power

Documentation KM2042. Sixteen channel digital output module with D-Sub Connector. Version: Date:

Product and functional description

7032 Digital-Analog Multimeter

CMSA-100 Manual. Cinema Media Server Automation

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

CMC III Temperature/Humidity Sensor

Device technology. Supply Bus voltage V DC. Current consumption via bus. Accuracy in the range 300 1,000 ppm 1,000 2,000 ppm 2,000 5,000 ppm

Operating instructions. Switching amplifier DN0210 DN / / 2015

Assembly instructions FMS-1 / FMS-2. Monitoring system

Product and functional description

LED LIGHT PANEL SMD. LED Light Panel SMD LED Modules for Office Lighting WU-M-542-G (270X540) LED MODULES FOR OFFICE LIGHTING WU-M-542-G

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Installation instructions Inclination sensor EC2019 EC / / 2013

See «Overview of types» 90 s / 60 mm 150 s / 100 mm Manuelle Auslösung der Adaption durch Drücken der Taste «Adaption» oder mit dem PC-Tool

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter

LED LIGHT PANEL SMD. LED Light Panel SMD LED Modules for Office Lighting WU-M-520 (250X250) WU-M-537 (270X270) LED MODULES FOR OFFICE LIGHTING

Operating instructions IO-Link master CabinetLine AL19xx

Operating instructions Evaluation system for flow sensors VS / / 2013

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS

SolConeX extra-low voltage flange socket

Expansion module EM-BAC-MOD-01. Installation manual

SITOP power supply. Selectivity modules. Overview. Safety notes. Description, device design, dimension drawing. Mounting/removal 3

MDM 011-Z1 Regen Resistor

AV24-MFT AV24-MFT2 AV24-MFT2-C105. Power consumption In operation For wire sizing N 1700 N Control Control signal Y Operating range

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS

Product and functional description

VR 71. Installation instructions. Installation instructions. For the competent person GB, IE. Publisher/manufacturer Vaillant GmbH

Operating Instructions

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

HST -TZ1 Guard-locking mechanism (Translation of Original Manual)

801 Stirrer. Manual EN

Operating manual. Diagnostic adapter VAS Operating manual Diagnostic adapter VAS Client documentation Revision: 00 Version: 05/2018

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

Rotary version, three-position control

Polymer Electric. Operating Instructions. Control Unit SG-RST 153. Version 0.3

Documentation. KM2604 and KM2614. Four channel relay module. Version: Date:

TECH-system Type 322 BASIC

Linienkoppler S KNX. Line coupler S KNX. Line coupler S KNX Status: March 16 (Subject to change) Page 1 of 29

B63/ NS MS. EtherNet/IP LINK

Magforce STD/STG/STW/SKD/SKS/STN

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

C9900-P208 and C9900-P209

Type ME43. Quickstart

List of contents. 7-2 CE (ENC EN55022) declaration of conformity CE (LVD EN60950) declaration of conformity. 15 發行章

english S-5EC Potentiometer 5-step Operating Instructions Keep for reference! L-BAL-E265-GB 1608 Index 002

Type Quickstart

Operating and mounting instructions

Product and functional description

Troubleshooting Manual

Metal Position Switch

Transcription:

Installation, operation and maintenance manual ST Foot switch Read this manual before installing, operating or maintaining this actuator. Failure to follow safety precautions and instructions could cause actuator failure and result in serious injury, death or property damage.

Technical instructions for Comfodesk Foot Switch STF / STH / STG Contents 1 General..................................................2 1.1 Using these technical instructions.................................2 1.2 Explanation of symbols..........................................2 1.3 Correct usage..................................................2 1.4 Environmental conditions........................................2 2 Functional method..........................................2 3 Installation and commissioning................................3 3.1 Components supplied............................................3 3.2 Installation...................................................3 3.3 Connection...................................................3 4 Operation...............................................4 4.1 Operation without memory function................................4 4.2 Operation with memory function..................................4 5 Servicing and maintenance....................................5 5.1 Maintenance..................................................5 5.2 Servicing.....................................................5 5.3 Guarantee....................................................5 5.4 Disposal......................................................5 5.5 Liability......................................................6 6 Technical data............................................6 7 Fault locating and clearance..................................6 Compliance with standards EN 60601-1 EN 60335-1 UL 2601-1 SKF Actuations System (Liestal) AG Oristalstrasse 97 CH-4410 Liestal, Switzerland Phone +41/ 61/ 925 41 11 Fax +41/ 61/ 921 37 04 Email actuators@skf.com 531e2950_03/01

1 General 1.1 Using these technical instructions The technical instructions are intended for design engineers who are using this Magnetic product in their applications, and for installation engineers who are working with the product. The technical instructions contain all relevant information about this Magnetic product, and are subject to alteration in the interests of technological progress. Please read the technical instructions carefully and observe the safety instructions. The technical instructions can also be used to produce the operating manual for the end product. This symbol indicates operations and conditions which may pose a risk to persons or objects. Observe these instructions carefully! This symbol identifies information and useful notes for the user. The switch must not be subjected to poor weather conditions. No equipment should be operated in an atmosphere where there is a risk of explosion. 1.2 Explanation of symbols The technical instructions identify possible dangers and important information using symbols next to the relevant text. 1.3 Correct usage The foot switch, in one-way to five-way versions, is used to operate between 1 and a maximum of 5 linear drives. It is intended for use with the following Magnetic drives and control units: STF: SEM1Control (for Ecomag) KOM1/3 Control Matrix MAX62/63/64/65 Drive Telesmart TXG Drive ZVB Distribution Box, SPP Blocking Device STG: KOM2/4 Control ZVB Distribution Box STH: KOM6 Control ZVB Distribution Box, SPP Blocking Device The foot switch is intended for interior applications only. 1.4 Environmental conditions Operation: Temperature 0 C to 40 C Air humidity max. 85% Storage/transportation: Temperature -20 C to 60 C Air humidity max. 95% 2 Functional method A pair of pushbuttons is fitted on the foot switch for each drive to be controlled. The function in question is identified using the relevant symbols. Pressing on one of the pushbuttons initiates drive operation. The drive will run for as long as the button is held down. 531d2950_03/01 Magnetic The Linear Drives Company Page 2/6

3 Installation and commissioning 3.1 Components supplied The foot switch comprises 1 to 5 pushbutton pairs, with connected cable set. Options Expanding threaded inserts (ZBE-521122) Rubber stops (ZBE-135310) 3.2 Installation Free-standing installation with rubber stops The foot switch can be positioned on any level surface using the 4 rubber stops (see options). Ensure that the entire surface of the switch is locating correctly, otherwise operation may be impaired. Fixed installation For fixed installation there are 4 holes with embedded expanding threaded inserts. See fig. 1: Fig. 1 Installation Ensure that the plug is inserted into the correct socket, otherwise there may be a risk of the socket in the equipment being destroyed. Note the plug shape (arrows must be at the top). 3.3 Connection The foot switch line is connected to the relevant control unit, the blocking device (SPP), the distribution box (ZVB) or directly to the drive. Fig. 2 Insert plugs correctly Fig. 3 shows various connection options: All cables must be secured so that no forces are exerted on the plug connections on the foot switch. Stripped plugs and cables may destroy the foot switch! Cables must not be bent or clamped in any way. This may cause malfunctions due to a short circuit. Fig. 3 Connection options When connecting the foot switch to the relevant equipment, please observe the technical instructions for that equipment. 531d2950_03/01 Magnetic The Linear Drives Company Page 3/6

4 Operation 4.1 Operation without memory function Fig. 4 Operation without memory function The drive is controlled directly using the direction keys and. Key Drive is disengaged. Key Drive is engaged. The initialisation run is compulsory, otherwise the memory positions cannot be set up. 4.2 Operation with memory function Initialisation run Move the drive (drives) using the and keys on the foot switch in counter-load direction to the limit position (= reference position) Position 3 Position 2 Position 1 Fig. 5 Operation with memory function The drive is controlled directly using the direction keys and. Key Drive is disengaged. Key Drive is engaged. Keys 1, 2 and 3 on the foot switch are used to move to saved positions. 531d2950_03/01 Magnetic The Linear Drives Company Page 4/6

Saving memory positions 1. Use the keys to move all the drives into the position you want to save on key 1. (Hold down the relevant keys until the required position has been reached.) 2. Press the m key followed by (or simultaneously) key 1. There should be a gap of no longer than 0.5 seconds between pressing the two keys. The save procedure is confirmed by an acoustic signal. If no acoustic signal is sounded, repeat step 2. It may be that the 0.5 seconds has been exceeded. Repeat steps 1 to 3 for programming keys 2 and 3 as required. Retrieving memory positions To retrieve a memory position, press the corresponding key 1, 2 or 3 on the foot switch. If in time the memory positions are no longer correct, repeat the initialisation run. Hold down the key until the drives have reached their positions. All drives will move simultaneously to the saved position. If the drives have not been moved to the reference positions during the commissioning process, this can be triggered by pressing the memory pushbutton M. 5 Servicing and maintenance 5.1 Maintenance The plastic housing and the connected cable need to be checked periodically (every six months) for mechanical damage (cracks). For multi-way switches, a check must be conducted regularly to ensure that the fixing chamber between the individual switches is securely in position. Two fastening clamps are required per connection. Damaged parts should normally be replaced by Magnetic Customer Services. 5.2 Servicing Observe the special magnetic guidelines in ML 0111/87. Cleaning water with chemical additives must be PH neutral. Excessively acidic or alkaline cleaning water may destroy metal and plastic parts. High-pressure steam cleaners are not permitted for use. Only the cleaning agent isopropyl alcohol may be used for disinfecting by hand. Water protection, cleaning, disinfecting The foot switch must only be washed or disinfected with the plug properly connected. Protection classification IPx5 only applies when the unit is plugged in. Following contamination, the foot switch should be cleaned as soon as possible to prevent residues drying onto the switch. A damp cloth and water are suitable for cleaning by hand. The addition of isopropyl alcohol is permitted. 5.3 Guarantee Under the proviso that the operating conditions have been observed and that the equipment does not show any evidence of mechanical damage due to incorrect usage, a guarantee period of 12 months following delivery shall apply to all mechanical and electrical components. 5.4 Disposal Control components and drives can be returned to Magnetic AG, Liestal for disposal. 5.5 Liability Liability for the correct functioning of the equipment shall be transferred to the owner or user, in all cases where the equipment has been incorrectly installed, maintained or serviced by persons not representing Magnetic Service or if the equipment has been operated in a manner inconsistent with the correct usage. Magnetic Aktiengesellschaft shall accept no liability for damage caused by non-compliance with the instructions provided in this documentation. The instructions provided in this document shall not represent additions to the guarantee and liability conditions for the sales and delivery conditions from Magnetic Aktiengesellschaft. 531d2950_03/01 Magnetic The Linear Drives Company Page 5/6

The product is not subject to identification regulations conforming to CE or EMC guidelines. The necessary EMC measures must be taken for the end product by the manufacturer of the end product, in accordance with the installation conditions, wiring and control system, and checked for the intended use. The manufacturer of the machine or system shall be obliged to observe these regulations. 6 Technical data Technical data Foot switches STF/STH/STG Switching voltage 12V DC Switched current 50 ma Connection cable 2500 mm Ambient temperature 0/+40 C Protection type/ IPx5/Safety extra-low voltage classification Colour grey/blue Weight 500/1000/1500 g Fixing screws M5 x (8 + material thickness) 325 311,6 148.5 223 191 40 230 82 108,6 105 7 Fault elimination and troubleshooting Fault Cause Rectification No function Poor Check plug connection plug connections Fig. 5 Dimension drawing The instructions in customer-specific documentation must also be observed. Should it not be possible to rectify a fault, please contact Magnetic AG, Liestal. 531d2950_03/01 Magnetic The Linear Drives Company Page 6/6