I/O Expansion Box Installation & Operator s Instruction Manual

Similar documents
FNet Repeater Installation & Operator s Instruction Manual

Chore-Tronics IDM Board Instruction

Pit Transition with 24" Fan Installation and Operators Instruction Manual

Bird Scale Control Installation & Operator s Instruction Manual

Chore-Tronics Mobile Server

Bird Scale Control Installation & Operator s Instruction Manual

C-Collect TM. by CTB Inc. Monitor Box Installation & Operator s Instruction Manual

Turbo Fiberglass Cone Fan and Grill Fan 36 Direct Drive. Installation & Operator s Instruction Manual

36'' & 48'' E-Z Shutter Fan Installation & Operator s Instruction Manual

48 Belt Drive Turbo with Tensioner Cone and Grill Fan Installation and Operators Instruction Manual

36" & 48" Shutter Box Fan Installation & Operator s Instruction Manual

Global Water Instrumentation, Inc.

Installation & Operator s Instruction Manual

Sonic Ruptor 400. User Manual

Resolver to Digital Expansion Board

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

PIM-Mini Pulsed Current Source Operation Manual

Specifications 1 Installation Procedures 2 Wiring Diagrams 3 Installation Checklist 5 Maintenance 5 Warranty Information 6 Material Return Policy 6

4300 WINDFERN RD #100 HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

Remote Microprocessor Control Panel. for use with the. Redi-Purge. High Efficiency Purge System

4300 WINDFERN RD #100 - HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

CC186 AND CC186/2 STAND-ALONE OR SYSTEM CLOCK

DCM Digital Control Modules

RLD-7.2 Two Channel Light Dimmer. (P/N: P-RLD-72 Digital) User & Installation Manual

Evolution Variable Output. With Override Pot. Hired Hand, Inc Co Rd 68 PO Box 99 Bremen, AL 35033

VSD-1MC MANUAL 0-10V / 4-20mA Variable Speed Module with Manual Override

PCM-7140 Pulsed Current Source Operation Manual

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

DVI Extender over Fiber with EMI Shielding

Series 803 LED Product Price Display

MiT. MOVING image TECHNOLOGIES INSTRUCTIONS FOR INSTALLATION, OPERATION, AND MAINTENANCE

PSA200 User s Manual

WARRANTY & LIMITATION OF LIABILITY

WARRANTY & LIMITATION OF LIABILITY

QuickTouch (QT4) Owner s Manual

Contents. HP E1586A Rack Mount Terminal Panel User s Manual

PMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A

212iL Rev. 1.1

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range

Spec Tech Industrial Electric Technical Support. Model: DL34-(XX) Quick Start

PMDX-105 Quad Isolator Board

MPP200 User s Manual

Tornado F-5. Motor Backspin Detect Relay And Probe For F-5 Motor Controller

IRRIGANDER 4 SPLITTER SWITCH

Remote Control for Inverter RC-200. Manual. Please read this manual before operating your RC-200 Remote Control

EMS Electrical Management System

AC4G-D User s Manual

Digital Lighting Systems, Inc. CD400-DMX DMX512 Four Channel Dimmer and Switch module

Wall. No opening (Example: LA-030-W)

User s Guide. POWERVAR Single Phase Power Conditioners

Tracer VM Bluetooth Interface

MAXIMA+ Series Rotary Level Indicator

Irrigander 8/2 Pro Expander 8 Zone Irrigation Expander Installation & User Guide Model 8ZEXT V1.0

Platinum Plus and Platinum Junior Controller

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

SP6R Level Controller Operation Manual

PD10. Pulse Divider Instructions PROUDLY MADE IN THE USA

Sapling Converter Box

User Guide. Control Box. RoscoLED TM.

MAXIMA + Series ROTARY LEVEL CONTROL

Installation Instructions

DVI KVM. Extra Long Range Extender Over One CAT5. User Manual EXT-DVIKVM-ELR. Release A8

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor

5504 Thermocouple Analog Input Module

PREFACE. Thank you for choosing Zen Space Desks. We hope your desk helps you find your zen when being used. Zen Space Desks Team

Installation Instructions

RE-82 RACK MOUNT DIMMER OWNERS MANUAL. 8 X 2400Watts. Revision /29/2007

TSD-SEQ6 Sequencer Controller

Remote Control for Inverter RC-300. Owner's Manual. Please read this manual BEFORE operating your RC-300 Remote Control

Proliphix EPA-60 Installation Guide

NSI DIGITAL DIMMING SYSTEM DDS 5300 / 5600 DIMMER PACK

OZONE SWITCH Model OS-6. OS-6 Features

Digital Lighting Systems, Inc.

Communication Hub. Model: HUB-1. 8 Pheasant Run Newtown, PA USA

Agilent Technologies E5339A 38-Pin Low-Voltage Probe

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

PDC-X Digital Controller

R & D SPECIALTIES SERIES 100 RO CONTROLLER USERS MANUAL. 2004, by R & D Specialties, Inc. All Rights Reserved.

VIP-812A DUAL NETWORKED STATION PORT

INSTALLATION INSTRUCTIONS

V-9939B MICROPHONE ADAPTER

Owner s Manual. TSD-DCPDV DC Power Distribution with Fixed & Variable Outputs. TSD-DCPDV DC Power Distribution. AtlasIED.com

Operation and Installation Manual

VIP-804 QUAD ENHANCED NETWORK AUDIO PORT

700 Series 200 Amp Clamp Meters

Pulse LED Instruction Guide

Data Reporter. Installation-Operation E rev.f

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL

Digital Audio Extender

HVPS-C. High Voltage Power Supply. HVPS-C. Package Contents: Sold Separately. Table of Contents:

Instruction Manual IM E Table of Contents

SoniChek MC. 99 Washington Street Melrose, MA Phone Toll Free TRIPLETT. Mini Sound Level Meter C Weighted

Instruction Manual. CT-4 High-Current Transformer

NEMA 6 Enclosure INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY KIND INCLUDING PERSONAL OR REAL PROPERTY OR FOR INJURY TO ANY PERSON.

Power Quality Recorder

Carefree-Security. Installation and programming instructions 1050A. Owner s Manual

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

Owner s Manual. TSD-DCPDV DC Power Distribution with Fixed & Variable Outputs. TSD-DCPDV DC Power Distribution. AtlasSound.com

Transcription:

I/O Expansion Box Installation & Operator s Instruction Manual May 2004

CTB Inc. Warranty I/O Expansion Box CTB Inc. Warranty CTB Inc. warrants each new Chore-Tronics product manufactured by it to be free from defects in material or workmanship for one year from and after the date of initial installation by or for the original purchaser. If such a defect is found by the Manufacturer to exist within the one-year period, the Manufacturer will, at its option, (a) repair or replace such product free of charge, F.O.B. the factory of manufacture, or (b) refund to the original purchaser the original purchase price, in lieu of such repair or replacement. Labor costs associated with the replacement or repair of the product are not covered by the Manufacturer. Conditions and Limitations 1. The product must be installed by and operated in accordance with the instructions published by the Manufacturer or Warranty will be void. 2. Warranty is void if all components of the system are not original equipment supplied by the Manufacturer. 3. This product must be purchased from and installed by an authorized distributor or certified representative thereof or the Warranty will be void. 4. Malfunctions or failure resulting from misuse, abuse, negligence, alteration, accident, or lack of proper maintenance shall not be considered defects under the Warranty. 5. This Warranty applies only to systems for the care of poultry and livestock. Other applications in industry or commerce are not covered by this Warranty. The Manufacturer shall not be liable for any Consequential or Special Damage which any purchaser may suffer or claim to suffer as a result of any defect in the product. Consequential or Special Damages as used herein include, but are not limited to, lost or damaged products or goods, costs of transportation, lost sales, lost orders, lost income, increased overhead, labor and incidental costs and operational inefficiencies. THIS WARRANTY CONSTITUTES THE MANUFACTURER S ENTIRE AND SOLE WARRANTY AND THIS MANUFACTURER EXPRESSLY DISCLAIMS ANY AND ALL OTHER WARRANTIES, INCLUDING, BUT NOT LIMITED TO, EXPRESS AND IMPLIED WARRANTIES AS TO MERCHANTABILITY, FITNESS FOR PARTICULAR PURPOSES SOLD AND DESCRIPTION OR QUALITY OF THE PRODUCT FURNISHED HEREUNDER. Chore-Tronics Distributors are not authorized to modify or extend the terms and conditions of this Warranty in any manner or to offer or grant any other warranties for Chore-Tronics products in addition to those terms expressly stated above. An officer of CTB, Inc. must authorize any exceptions to this Warranty in writing. The Manufacturer reserves the right to change models and specifications at any time without notice or obligation to improve previous models. Effective: July 2004 Thank You CTB Inc. P.O. Box 2000 Milford, Indiana 46542-2000 U.S.A. Phone (574) 658-4101 Fax (877) 730-8825 Email: ctb@ctbinc.com Internet: http//www.ctbinc.com The employees of CTB Inc. would like to thank your for your recent Chore-Tronics purchase. If a problem should arise, your Chore-Tronics distributor can supply the necessary information to help you. 2

Contents Topic Page User CTB Inc. Warranty.................................................. 2 General............................................................. 4 Support Information.......................................................... 4 Safety Information................................................... 4 Follow Safety Instructions..................................................... 4 Decal Descriptions........................................................... 4 DANGER : Electrical Hazard.................................................. 4 Introduction to Control............................................... 5 Mounting the Control................................................. 5 Wiring............................................................. 6 Power Supply Wiring......................................................... 7 I/O Net Wiring.............................................................. 8 Pulsed Water Meter and Feed Scale Wiring....................................... 9 Airspeed Meter Wiring....................................................... 10 Remote Light Dimmer Control Wiring........................................... 11 Activating Boards in Chore-Tronics Control............................ 12 Troubleshooting..................................................... 13 Part Numbers....................................................... 16 C,D C,D,I C,I C,I C,I C,I C,I C,I C * Legend: C = Customer (end user), D = Distributor (sales), I = Installer of equipment 3

General I/O Expansion Box General Support Information The Chore-Tronics I/O Expansion Box Control is used to add additional inputs and outputs to the Chore- Tronics Model 16 and Model 24 Climate Control. Using this equipment for any other purpose or in a way not within the operating recommendations specified in this manual will void the warranty and may cause personal injury. This manual is designed to provide comprehensive planning, installation, safety, operation, and parts listing information. The Table of Contents provides a convenient overview of the information in this manual. The Table of Contents also specifies which pages contain information for the sales personnel, installer, and consumer (end user). Safety Information Caution, Warning and Danger Decals have been placed on the equipment to warn of potentially dangerous situations. Care should be taken to keep this information intact and easy to read at all times. Replace missing or damaged safety decals immediately. Using the equipment for purposes other than specified in this manual may cause personal injury and/or damage to the equipment. Follow Safety Instructions Carefully read all safety messages in this manual and on your equipment safety signs. Follow recommended precautions and safe operating practices. Keep safety signs in good condition. Replace missing or damaged safety signs. Decal Descriptions DANGER : Electrical Hazard Disconnect electrical power before inspecting or servicing equipment unless maintenance instructions specifically state otherwise. Ground all electrical equipment for safety. All electrical wiring must be done by a qualified electrician in accordance with local and national electric codes. Ground all non-current carrying metal parts to guard against electrical shock. With the exception of motor overload protection, electrical disconnects and over current protection are not supplied with the equipment. 4

I/O Expansion Box Introduction to Control Introduction to Control Mounting the Control The Chore-Tronics I/O Expansion box can consist of an IARM-2 board, and IDM- 16 board, or both. The IARM board provides a 0-10 Vdc output for controlling an external remote light dimmer. The IDM board provides digital inputs for up to 8- water meters, 7-feed scales and an airspeed meter. The Chore-Tronics I/O Expansion Box requires a minimum mounting area of approximately 18" x 18." The Figure below shows the I/O Expansion Box Mounted along with the Chore-Tronics Model 16 giving extra space to allow for opening the boxes. The box should be mounted level on a solid backing using the mounting holes provided. Approximately 38" [96.5 cm] 10.75" [27.3 cm] Approx. 25" [63.5 cm] 17.5" [44.5 cm] 13.25" [33.7 cm] Approx. 36" [91.4 cm] 15.5" [39.4 cm] MT1820-005 04/04 Figure 1. Mounting No other electrical equipment (transformers, light dimmers, additional relays, etc.) should be mounted inside the expansion box. 5

Wiring I/O Expansion Box Wiring The Chore-Tronics I/O Expansion Box can consist of a maximum of three different types of boards. The boards are the IARM-2 board (Item 2, Figure 2), the IDM-16 board (Item 1), and the Power Supply (Item 3). 2 1 3 Item Description 1 Digital Input (IDM-16) Board 2 Analog Output (IARM-2) Board 3 25W Power Supply Figure 2. Wiring 6

I/O Expansion Box Wiring Power Supply Wiring When Wiring the I/O Expansion box, it is recommended that the line voltage wires be brought into one side of the bottom of the box and the low voltage wires (water meter inputs, feed scale inputs, light dimmer control output) be brought into the opposite side of the bottom of the box (Figure 3 below). Bring the 220 volt power supply wires and connect them to the Power supply terminals labeled L1 and L2. The ground rail is only to be used to connect the Expansion box to Earth ground. It is recommended that a ground rod be located no more than 8-10' away from the Expansion box. The Expansion box should be connected to ground using a 12 gauge wire or larger. As always, check the local electric code for additional requirements. Item Description 1 Water Meter, Feed Scale, Light Dimmer Wires (Low Voltage) 2 I/O Net (Low Voltage) 3 Input/Output wires (High Voltage) 3 1 2 Earth Ground Figure 3. Power Supply Wiring 7

Wiring I/O Expansion Box I/O Net Wiring Connect the I/O net terminals in the Expansion box to I/O net terminals on the I/O board of the Chore-Tronics Control using twisted pair sensor wire (See Figure 4 below). Make sure that the positive (+) terminal of the Expansion box is connected to the positive (+) terminal of the control's I/O board. Check the dip switch number 2 located just above the I/O net terminals in the Chore-Tronics Control's I/O board. Make sure that the switch is in the ON position. (See Figure 4) ON 1 2 - + + - + - + - + - Figure 4. I/O Net Wiring 8

I/O Expansion Box Wiring Pulsed Water Meter and Feed Scale Wiring The pulsed water meters and feed scales require non-shielded 20 gauge twisted pair wire. This wire is available through Chore-Time (part number 42208). When routing this wire in the house be sure to keep the wire a minimum of 12" away from line voltage wiring. If there is a need for the sensor wire to cross line voltage wires, cross them at a 90 degree angle to each as shown below. 1 Pulsed Water Meter #5 2 Item Description 1 Non-Shielded Twisted Pair Wire 2 Line Voltage Wiring Figure 5. 90 Cross-over Connect Pulsed Water Meters #2 through #9 to the IDM board terminals as shown in Figure 6 below using the Twisted Pair Wire. If a water meter not sold by CTB, inc. is used make sure that has a dry contact output connection. DO NOT use a water meter that sends voltage out with every pulse. Note the correct position of the IDM Board Dip Switches. Pulsed Water Meter #4 Pulsed Water Meter #3 Pulsed Water Meter #2 3 Pulsed Water Meter #9 2 Pulsed Water Meter #8 Pulsed Water Meter #7 Pulsed Water Meter #6 4 1 Item Description 1 IDM Board 2 Non Shielded Twisted Pair Wire 3 Water Meter 4 IDM Board Dip Switches 1 2 3 4 5 ON MT1820-014 5/04 Figure 6. Water Meter Wiring 9

Wiring I/O Expansion Box Using the blue and brown wires from the Feed Scales Connect Feed Scales #2 through #9 to the IDM board terminals using Twisted Pair Wire (See Figure 7 below). Note the correct position of the Dip Switches. See Feed Scale Manual MT1811 for additional information if needed. Item Description 1 IDM Board 2 Non Shielded Twisted Pair Wire 3 Feed Scale 4 IDM Board Dip Switches Feed Scale #5 Feed Scale #4 Feed Scale #3 Feed Scale #2 4 Feed Scale #8 Feed Scale #7 Feed Scale #6 1 2 3 4 5 ON MT1820-015 05/04 1 Figure 7. Feed Scale Wiring Airspeed Meter Wiring The Airspeed Meter connects to the last digital input terminal on the IDM board using a three conductor wire with a shield (See Figure 8 for Detailed Wiring). See Air Speed Meter manual for installing the Wind Speed Sensor inside the house. Black 3 Item Description 1 Air Speed Meter 2 Last Input Terminal 3 Non Shielded Twisted Pair Brown Green White 2 Figure 8. Airspeed Meter Wiring 10

I/O Expansion Box Wiring Remote Light Dimmer Control Wiring Before connecting the IARM board to a light dimmer, be sure to check that the light dimmer is equipped for remote control dimming. The light dimmer must be able to accept a 0-10 or 10-0 Vdc signal from the IARM board. Refer to the information provided by the light dimmer manufacturer for remote dimming wiring instructions. The Light dimmer connects to the IARM board at the analog output #1 (See Figure 9 below). Be sure that the positive terminal on the IARM board matches with the positive wire/terminal on the light dimmer. 4 ON 5 4 3 2 1 Light Dimmer 0-10 Vdc Input 5 2 + - 1 + - 3 Figure 8. Airspeed Meter Wiring Item Description 1 IARM Board 2 Light Dimmer 3 Non Shielded Twisted Pair 4 Dip Switch 5 Analog Output #1 11

Activating Boards in Chore-Tronics Control I/O Expansion Box Activating Boards in Chore-Tronics Control Make sure that the Chore-Tronics Mdl 16/24 has a D1.0 level or greater EPROM chip installed. Once the Expansion Box has been properly installed, turn power on to the Chore-Tronics control and the Expansion Box. Go to the Setup screen (screen 12) and scroll down to the following section. OPTIONAL HARDWARE USED: Digital input board (IDM-16) Analog output board (IARM-2) NO NO For each board that is installed in the expansion box change the "NO" selection to "YES." After confirming that the board should be activated, the control will try to communicate with the board(s). If an error message appears immediately, check the wiring connections at both boxes and then re-try to change the selection to "YES" (Figure 7 below). Once the board has been activated please refer to the Model 16/24 manual or manual supplement for instructions on setting up the desired features. OPTIONAL HARDWARE USED: Digital input board (IDM-16) Analog output board (IARM-2) YES NO Change to "Yes" 12

I/O Expansion Box Troubleshooting Troubleshooting Problem Possible Cause Possible Solution ATTENTION!!! Board not available message appears when trying to activate IDM-16 or IARM-2 IARM IONET ERROR alarm appears in Alarms screen of Chore-Tronics control. Board does not function. A.) I/O Net wires improperly connected. B.) No power to board(s) C.) Address DIP switches set incorrectly. D.) Defective board in expansion box E.) Defective I/O board in Chore-Tronics control A.) No power to board. B.) I/O Net wires disconnected or connected incorrectly. C.) Address DIP switches set incorrectly on IARM-2 board. D.) Defective IARM-2 board. A.) Check for proper I/O Net wiring in both the expansion box and the Chore-Tronics control. I/O Net is polarity sensitive. B.) Check for 24 Vdc supply to board(s). C.) See IDM-16 and IARM- 2 wiring diagrams (page 9 and 11) for proper DIP switch settings. Cycle power off then on after changing switch settings. D.) Replace defective board E.) Replace defective I/O board. A.) Check for 24 Vdc supply to IARM-2 board. B.) Check for proper I/O Net wiring in both the expansion box and the Chore-Tronics control. I/O Net is polarity sensitive. C.) See IARM-2 wiring diagrams page 11 for proper DIP switch settings. Cycle power off then on after changing switch settings. D.) Replace defective board Troubleshooting Continued... 13

Troubleshooting I/O Expansion Box IDM-16 IONET ERROR alarm message appears in Alarms screen of the Chore- Tronics control. Board does not function. A.) No power to board. B.) I/O Net wires disconnected or connected incorrectly. C.) Address DIP switches set incorrectly on IDM-16 board. D.) Defective IDM-16 board. A.) Check for 24 Vdc supply to IDM-16 board. B.) Check for proper I/O Net wiring in both the expansion box and the Chore-Tronics control. I/O Net is polarity sensitive. C.) See IDM-16 wiring diagrams page 9 for proper DIP switch settings. Cycle power off then on after changing switch settings. D.) Replace defective board IARM-2 board will not dim lights on remote light dimmer. 5 Vdc is present at Analog Output 1 when light percentage is set to 50% on the Light Clock of the Chore-Tronics control. IARM-2 board will not dim lights on remote light dimmer. 5 Vdc is NOT present at Analog Output 1 when light percentage is set to 50% on the Light Clock of the Chore-Tronics control. A.) Improper connection between IARM-2 board and remote light dimmer. B.) See remote light dimmer manual for additional information A.) See IARM IONET ERROR section of trouble shooting guide. A.) Check connections between IARM-2 board and remote light dimmer. Connection is usually polarity sensitive. Troubleshooting Continued... 14

I/O Expansion Box Troubleshooting Airspeed sensor readout on Chore-Tronics control constantly reads LOW even while in full tunnel mode. 1 or more of water meter(s) and/or feed scale(s) #2-#9 not recording usage in Chore-Tronics control. A.) Airspeed less than 125 feet per minute. B.) Airspeed sensor not properly connected to the IDM-16 board. C.) Defective airspeed sensor. D.) Defective IDM-16 board. A.) Function is not set on the water meter/feed scale in the setup screen. B.) Water meter/feed scale not properly connected to the IDM-16 board. C.) Defective water meter, or feed scale pulse switch. D.) Defective IDM-16 board. A.) Airspeed readout will show LOW until airspeed reaches 125 feet per minute or greater. A.) Check wiring connections for the airspeed sensor at the IDM-16 board. See page xx for wiring diagram. B.) Replace defective airspeed sensor. D.) Replace defective board. A.) Be sure that every connected water meter is set either as a drinker or a non drinker meter in the setup screen of the Chore-Tronics control. Be sure that every connected feed scale is set either as a feed or non feeder. B.) Check for proper wiring connections on the IDM-16 board. See page xx for wiring diagram. C.) Replace defective meter or feed scale pulse switch. D.) Replace defective IDM- 16 board. 15

Part Numbers I/O Expansion Box Part Numbers 1 12 2 4 7 10 5 9 8 6 3 49330 IDM 49331 IARM 49332 IDM-IARM Expansion Box Expansion Box Expansion Box Item Description Part No. 1 Sarel Box (13 x 10.2 x 3.6) 49328 49328 49328 2 I/O Expansion Plate 49329 49329 49329 3 Digital Input (IDM) Board 48536 not applicable 48536 4 Power Supply 25W 48861 48861 48861 5 Grounding Rail 43384-2 43384-2 43384-2 6 3 Pole Terminal Strip 34925-3 34925-3 34925-3 7 Expansion Box Input Power Decal 2526-440 2526-440 2526-440 8 Expansion Box I/O Net Decal 2526-441 2526-441 2526-441 9 Ground Decal 2527-63 2527-63 2527-63 10 I/O Exp. Box Decal 2529-832 2529-832 2529-832 11 Twisted Pair Sensor Wire (Not Shown) 42208 42208 42208 12 Analog Output (IARM-2) Board not applicable 48537 48537 16

I/O Expansion Box Part Numbers Page Left Blank For Notes: 17

Part Numbers I/O Expansion Box Revisions to this Manual Page No. Description of Change New Book Contact your nearby Chore-Tronics distributor or representative for additional parts and information. CTB Inc. P.O. Box 2000 Milford, Indiana 46542-2000 U.S.A. Phone (574) 658-4101 Fax (877) 730-8825 E-Mail: ctb@ctbinc.com Internet: http//www.ctbinc.com Printed in the U.S.A. 18