MN1954 Fieldbus Option

Similar documents
PROFIBUS DP Option. for FlexDrive II, Flex+Drive II and MintDrive II. Reference Manual 10/02 MN1911

DeviceNett Option. for FlexDrive II, Flex+Drive II and MintDrive II. Reference Manual 10/02 MN1910

ABB Drives. User s Manual. Modbus Adapter Module RMBA-01

CVIC II - CVIL II - CVIR II - MULTICVIL II - Memory Mapping - Manual

ABB Drives. User s Manual Modbus Adapter Module FMBA-01

ABB Drives. User s Manual Pulse Encoder Interface Module MTAC-01

Contents User Manual For PIM

ABB Drives. User s Manual. Analogue I/O Extension Module RAIO-01

G5 Weighing Instrument

CAN Option for FlexDrive II, Flex+Drive II and MintDrive II. Reference Manual 10/02 MN1909

B63/ NS MS. EtherNet/IP LINK

Profibus DP Expansion Board

Motion Control Products Application note Ethernet POWERLINK routing using motion drives

ABB Drives. User s Manual. Digital I/O Extension Module RDIO-01

Anybus-CC CFW-11. User s Manual. Phone: Fax: Web: -

FACTORY AUTOMATION MANUAL CBX500 HOST INTERFACE MODULES

User Manual Gateway component for EtherNet/IP

DeviceNet Expansion Board

User s Manual Pulse Encoder Interface Module OTAC-01

L5351 DeviceNet Communications Interface

EtherNet/IP Communications Module

crio PN Installation Instructions V0.2/ COMSOFT

INpact Slave PCIe. Profibus/PROFINET IRT Fiber Optic/CC-Link/DeviceNet USER MANUAL EN 1.5

Start-up Guide. AF 100 Adapter Kit NAFA-01

YASKAWA AC Drive 1000-Series Option EtherNet/IP. Technical Manual

Motion Control Products Application note Ethernet POWERLINK routing using the MotiFlex e180

GV3000/SE AC Drive ControlNet Network Communication Option Board M/N 2CN3000

270 MHz Control Modules

Type ME43. Quickstart

Thyro-PX Anybus PROFINET

Removal and Installation8

Anybus Communicator STARTUP GUIDE. IIoT. SP en-us ENGLISH

EtherNet/IP. EtherNet/IP. Installation Manual. YASKAWA AC Drive Option. Type: SI-EN3

Resolver to Digital Expansion Board

XPSMCMx Fieldbus Expansion Modules Instruction Sheet (Original Language)

Sure Coat Modular Gun Control System Part C: UCS ProfiBus Interface Card. Customer Product Manual Part B

Varispeed SERIES OPTION CARD DeviceNet COMMUNICATION INTERFACE CARD USER'S MANUAL Model: SI-N1

Output Interfaces for SVS2000 TM Installation & Operation Manual

User Manual Revision English

Installing the Cisco SFS 3504 Server Switch

DeviceNet PCI Card Instructions Manual

YASKAWA AC Drive Option EtherNet/IP. Technical Manual

RS485 DF1 Communications Module

Operation Manual. Fieldbus system EX510-GDN1. DeviceNet Compatible GW unit

Table of Contents 1 ABOUT THIS DOCUMENT GENERAL COPYRIGHT INFORMATION TERMS ABOUT THE GATEWAY PRODUCT FUNCTIO

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

Anybus-CC Technical Introduction

User Manual CIFX Cards Real Time Ethernet

Dimensional drawings. Dimensional drawings

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

Anybus X-gateway. PROFINET IRT (2.32) Interface NETWORK GUIDE

efesotomasyon.com - Control Techniques,emerson,saftronics -ac drive-servo motor Start-up Guide DeviceNet Adapter Module NDNA-02

Installation Manual. YASKAWA AC Drive-V1000 Option EtherNet/IP. Type SI-EN3/V

Contents i. 1 General Information 2 Introduction. 3 Basic Installation. 4 Input / Output. Contents

Instruction Manual Power Distribution System SVS16-EN-XX

YASKAWA AC Drive 1000-Series Option EtherNet/IP. Technical Manual

Power Xpert Meter 2000 Gateway Card Kit

Optional Accessories 6 2

Replacing the Power Supply

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

Revision History E F G H J K Revision Description: K > Allegion Rebranding.

RMx621. Appendix to the operating manual

This manual was downloaded on (0) TS8000. Firewire Option 8000/FA/00 HA Issue 1

Technical Manual SMART TRAC PS Card

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E

115/230 VAC Digital Input Module OHDI-01

PS/IO Circuit Board Retrofit

MPCR Series DeviceNet Technical Manual TDMPCRDNTM2-0EN 01/08 Subject to change without notice

EX-RC1 Remote I/O Adapter

TRC-190 User s Manual

Altivar - Lexium. Option modules DANGER S1A S1A /8 VW3A3601 / VW3A3608 VW3A3616 / VW3A3627 VW3A3619 VW3A3720 VW3A3721 VW3M3308

DeviceNet Module. User Manual. 1 Important User Information. 2 Installation

ControlStation CEIIx Communication Module Quick Install Guide

Mercury Helios ASSEMBLY MANUAL & USER GUIDE

Instruction Manual Power Distribution System SVS16-PN-XX

BNI EIP Z016. IP67 Modules, 8 Outputs BNI EIP Z016 BNI EIP Z016 IP67 Modules, 16 Outputs User s Guide

Anybus X-gateway. PROFIBUS Master Interface NETWORK GUIDE SCM EN 1.0 ENGLISH

RMx621 /FML621. Appendix to the operating manual

Install the DeviceNet Module using the following procedure:

Date Revision Change(s) 29/07/ First version

Manual. Decentralized Drive Control MOVIFIT FDC-SNI Connection to PROFIBUS/DeviceNet with UFF41B Fieldbus Gateway

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Ethernet/IP Module. User Manual. Contents

G3 Series DeviceNet TM Technical Manual

User Manual Revision English

AnyBus-PCI Profibus DPV1 Master

Serial PROFIBUS Interface

To connect the AC adapter:

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS

Installing the Cisco Unified Videoconferencing 3545 MCU

OPTION FOR ABB DRIVES, CONVERTERS AND INVERTERS FDNA-01 DeviceNet adapter module User s manual

OWC Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE

- 15G0078B120 - DEVICENET MODULE INSTRUCTIONS FOR ASAC-0/ASAC-1/ASAB

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS

User Manual Revision English

DSC FIELDBUS MODULES...

BridgeWay. PROFIBUS to DeviceNet Gateway User Manual. Part No. AB7605. Publication PUB-AB

Safety Instruction. This symbol indicates the possibility of injury or damage to property.

Profinet Module. User Manual. Contents

Flex+Drive II and MintDrive II Brushless AC Servo. Controls. Product Characteristics Overview

Transcription:

MN1954 Fieldbus Option

Contents 1 General Information 2 Introduction 2.1 Fieldbus option features................................ 2-1 2.1.1 Assembly.................................................... 2-2 2.1.2 Installation................................................... 2-3 2.1.3 Connection.................................................. 2-4 3 Fieldbus types 3.1 Introduction.......................................... 3-1 3.1.1 OPT-FB-001: DeviceNet........................................ 3-1 3.1.2 OPT-FB-002: PROFIBUS DP.................................... 3-2 3.1.3 OPT-FB-004: EtherNet/IP....................................... 3-3 3.1.4 OPT-FB-005: Modbus/TCP...................................... 3-4 3.1.5 OPT-FB-006: PROFINET IO..................................... 3-5 4 Configuration 4.1 Introduction.......................................... 4-1 4.1.1 System Config Wizard.......................................... 4-1 4.1.2 Connectivity Wizard........................................... 4-2 4.1.3 Spy window.................................................. 4-2 4.1.4 Device characterization......................................... 4-2 4.1.5 Application Notes............................................. 4-2 5 FAQ 5.1 Introduction.......................................... 5-1 MN1954WEN Contents i

ii Contents MN1954WEN

General Information 1 General Information 1 LT0254A02EN Copyright ABB (c) 2012. All rights reserved. This manual is copyrighted and all rights are reserved. This document or attached software may not, in whole or in part, be copied or reproduced in any form without the prior written consent of ABB. ABB makes no representations or warranties with respect to the contents hereof and specifically disclaims any implied warranties of fitness for any particular purpose. The information in this document is subject to change without notice. ABB assumes no responsibility for any errors that may appear in this document. Mint is a registered trademark of Baldor, a member of the ABB group. Windows XP, Windows Vista and Windows 7 are registered trademarks of the Microsoft Corporation. UL and cul are registered trademarks of Underwriters Laboratories. Anybus is a registered trademark of HMS Industrial Networks Inc ABB Ltd Motion Control 6 Bristol Distribution Park Hawkley Drive Bristol, BS32 0BF United Kingdom Telephone: +44 1454 850000 Fax: +44 1454 859001 E-mail: motionsupport.uk@baldor.com Web site: www.abbmotion.com See rear cover for other international offices. MN1954WEN General Information 1-1

Product Notice Only qualified personnel should attempt the start-up procedure or troubleshoot this equipment. This equipment may be connected to other machines that have rotating parts or parts that are controlled by this equipment. Improper use can cause serious or fatal injury. Safety Notice Intended use: Drives incorporating this product are intended for use in stationary ground based applications in industrial power installations according to the standards EN60204 and VDE0160. They are designed for machine applications that require variable speed controlled three-phase brushless AC motors. These drives are not intended for use in applications such as: Home appliances Medical instrumentation Mobile vehicles Ships Airplanes. Unless otherwise specified, the drive is intended for installation in a suitable enclosure. The enclosure must protect the drive from exposure to excessive or corrosive moisture, dust and dirt or abnormal ambient temperatures. The installation, connection and control of drives is a skilled operation, disassembly or repair must not be attempted. In the event that a drive fails to operate correctly, contact the place of purchase for return instructions. Precautions! WARNING! WARNING! CAUTION! CAUTION! CAUTION Do not touch any circuit board, power device or electrical connection before you first ensure that no high voltage is present at this equipment or other equipment to which it is connected. Electrical shock can cause serious or fatal injury. Only qualified personnel should attempt to start-up, program or troubleshoot this equipment. MEDICAL DEVICE / PACEMAKER DANGER: Magnetic and electromagnetic fields in the vicinity of current carrying conductors and industrial motors can result in a serious health hazard to persons with cardiac pacemakers, internal cardiac defibrillators, neurostimulators, metal implants, cochlear implants, hearing aids, and other medical devices. To avoid risk, stay away from the area surrounding a motor and its current carrying conductors. Electrical components can be damaged by static electricity. Use ESD (electrostatic discharge) procedures when handling this device. To prevent equipment damage, be certain that input and output signals are powered and referenced correctly. To ensure reliable performance of this equipment, be certain that all signals are shielded correctly. 1-2 General Information MN1954WEN

Introduction 2 Introduction 2 2.1 Fieldbus option features The fieldbus options are available as customer-fitted options for the MotiFlex e100 range of drives. Each of these options consists of a module which must be attached to the fieldbus gateway carrier card, OPT-MF-030. This two-part construction allows a different fieldbus module to be fitted at a later date without needing to replace the carrier card. Each option adds slave support for one of the following fieldbuses: OPT-FB-001: DeviceNet (Anybus-CC AB6201) OPT-FB-002: PROFIBUS DP (Anybus-CC AB6200) OPT-FB-004: EtherNet/IP (Anybus-CC AB6214) OPT-FB-005: Modbus/TCP (Anybus-CC AB6213) OPT-FB-006: PROFINET IO (Anybus-CC AB6215) Other fieldbus options may become available. Check www.abbmotion.com for the latest range. The assembled option must only be inserted in the MotiFlex e100 s top slot (slot 1). MN1954WEN Introduction 2-1

2.1.1 Assembly CAUTION Before touching the fieldbus module or carrier card, be sure to discharge static electricity from your body and clothing by touching a grounded metal surface. Alternatively, wear an earth strap while handling the items. 1. Slide the fieldbus module through the opening in the metal mounting bracket. Check that the leading edge of the module engages in the arms / rails of the connector on the carrier card, and that the fieldbus module is flat against the PCB. Figure 1: Slide in fieldbus module 2. Make sure that the pins of the connector on the carrier card line up with the socket on the rear of the fieldbus module. Push the module until the connector on the rear of the module has fully engaged with the connector on the carrier card. Figure 2: Engage with connector 3. Tighten the front fascia screws to 2.5 N m (22 lb-in) using a Torx T8 screwdriver. Tightening the screws lowers retaining clips on the underside of the module, securing it to the metal mounting bracket. Figure 3: Tighten front screws 2-2 Introduction MN1954WEN

2.1.2 Installation 1. Remove all power sources from the MotiFlex e100. Pull off the drive s top front panel cover. Remove the option slot cover s retaining screw. Figure 4: Loosen retaining screw 2. Insert a screwdriver under the edge of the option slot cover and gently lever out the cover. Figure 5: Lift out cover 3. Confirm that the correct option card is being installed. The description is printed on the mounting bracket. Insert the option card with the fieldbus module facing towards the center of the drive. The edges of the option card should locate behind retaining brackets inside the drive. Figure 6: Insert the option card MN1954WEN Introduction 2-3

4. Push in the option card until it clicks into place. The option card s external connector plate should finish approximately level with the 8 posts along the edge of the option slot. Figure 7: Click into place 5. Insert the retaining screw and tighten. If the screw will not locate in the threaded socket on the option card, then check the position of the option card. The screw must be fitted since it provides mechanical support and an electrical chassis connection for the option card. The recommended tightening torque is 0.7 N m (6.2 lb-in). Figure 8: Tighten retaining screw 6. Push on the drive s front panel cover until it clicks into place. 2.1.3 Connection The cables listed in the following table connect Ethernet based fieldbus option cards (Ethernet/IP, Modbus/TCP, PROFINET IO) to other network hardware such as PLCs. The cables are standard CAT5e shielded twisted pair (S/UTP) crossover Ethernet cables: Cable assembly description Part Length m ft CAT5e Ethernet cable CBL002CM-EXS CBL005CM-EXS CBL010CM-EXS CBL020CM-EXS CBL050CM-EXS CBL100CM-EXS 0.2 0.5 1.0 2.0 5.0 10.0 0.65 1.6 3.3 6.6 16.4 32.8 2-4 Introduction MN1954WEN

Fieldbus types 3 Fieldbus types 3 3.1 Introduction All external connections to the fieldbus option card are made using the module s front fascia connector. The required mating connector is supplied where necessary. 3.1.1 OPT-FB-001: DeviceNet The DeviceNet option provides the MotiFlex e100 with slave support for the DeviceNet protocol. Module Status LED Network Status LED 5 V+ in Positive bus supply voltage 4 CAN_H CAN high bus line 3 Shield Cable shield 2 CAN_L CAN low bus line 1 V- in Negative bus supply voltage The module draw a maximum of 50 ma from the bus supply. Figure 9: Connector pin assignments - DeviceNet 3.1.1.1 LED states State Network Status LED (NS) Module Status LED (MS) Off No power Not online / no power Green Online, connection(s) Normal operation established Flashing green (1 Hz) Online, no connection Missing or incomplete configuration. Device needs commissioning. Red Critical link failure Unrecoverable fault(s) Flashing red (1 Hz) Connection(s) timed out Recoverable fault(s) Alternate red/green Self test Self test MN1954WEN Fieldbus types 3-1

3.1.2 OPT-FB-002: PROFIBUS DP The PROFIBUS DP option provides the MotiFlex e100 with slave support for the PROFIBUS DP protocol, using the DP-V1 service level. Status LED (NC) 1 (NC) 2 RX/TX Data B 3 RTS 4 0 V for termination 5 6 +5 V for termination 7 (NC) 8 RX/TX Data A 9 (NC) Operating Mode LED Figure 10: Connector pin assignments - PROFIBUS DP 3.1.2.1 LED states State Operating Mode LED (OP) Status LED (ST) Off Not online / no power No power / not initialized Green Online, data exchange Initialized Flashing green (1 Hz) Online, clear Initialized, diagnostic event(s) present Red - Exception error Flashing red (1 flash) Paramaterization error - Flashing red (2 flashes) PROFIBUS configuration error - The connector housing is connected to the Anybus protective earth via cable shield filters, according to the PROFIBUS standard. Pin 6 can supply up to 60 ma at 22 C (72 F), which is sufficient to power master simulators etc. For normal operating conditions (higher temperatures) the maximum is 10 ma. 3-2 Fieldbus types MN1954WEN

3.1.3 OPT-FB-004: EtherNet/IP The EtherNet/IP option provides the MotiFlex e100 with slave support for the EtherNet/IP protocol. Module Status LED Link/Activity LED Network Status LED 8 (NC) 7 (NC) 6 RX- Receive- 5 (NC) 4 (NC) 3 RX+ Receive+ 2 TX- Transmit- 1 TX+ Transmit+ Figure 11: Connector pin assignments - EtherNet/IP 3.1.3.1 LED states State Off Green Flashing green (1 Hz) Network Status LED (NS) No power / no IP address Online, one or more connections established (CIP Class 1 or 3) Online, no connections established Module Status LED (MS) No power Controlled by a scanner in run state Not configured or scanner in idle state The Ethernet interface supports 10/100 Mbit/s, full or half duplex operation. Link / Activity LED (LINK) No link / no activity Link established Flickering green (10 Hz) - - Activity Red Duplicate IP address, FATAL error Major fault (EXCEPTION state, FATAL error etc.) - Flashing red (1 flash) One or more connections timed out (CIP Class 1 or 3) Recoverable fault(s) - - MN1954WEN Fieldbus types 3-3

3.1.4 OPT-FB-005: Modbus/TCP The Modbus/TCP option provides the MotiFlex e100 with slave support for the Modbus/TCP protocol. Module Status LED Link/Activity LED Network Status LED 8 (NC) 7 (NC) 6 RX- Receive- 5 (NC) 4 (NC) 3 RX+ Receive+ 2 TX- Transmit- 1 TX+ Transmit+ Figure 12: Connector pin assignments - Modbus/TCP 3.1.4.1 LED states State Off Green Flashing green (1 Hz) Network Status LED (NS) No power / no IP address In Process Active or Idle state Waiting for connections Module Status LED (MS) No power Normal operation - - The Ethernet interface supports 10/100 Mbit/s, full or half duplex operation. Link / Activity LED (LINK) No link / no activity Link established Flickering green (10 Hz) - - Activity Red Duplicate IP address or FATAL event Major fault (EXCEPTION state, FATAL event etc.) - Flashing red (1 flash) Process Active time-out Minor fault, or the present IP settings differ from the settings in net.cfg.ob. - 3-4 Fieldbus types MN1954WEN

3.1.5 OPT-FB-006: PROFINET IO The PROFINET IO option provides the MotiFlex e100 with slave support for the PROFINET IO protocol. Module Status LED Link/Activity LED Network Status LED 8 (NC) 7 (NC) 6 RX- Receive- 5 (NC) 4 (NC) 3 RX+ Receive+ 2 TX- Transmit- 1 TX+ Transmit+ Figure 13: Connector pin assignments - PROFINET IO 3.1.5.1 LED states State Network Status LED (NS) Module Status LED (MS) Note that a test sequence is performed on the MS and NS LEDs at startup. The Ethernet interface supports 10/100 Mbit/s, full or half duplex operation. Link / Activity LED (LINK) Off Offline Not initialized No link / no activity Green Online (RUN) Normal operation Link established Flashing green (1 Hz) Online (STOP) - - Flashing green: 1 flash - Diagnostic event(s) - 2 flashes Blink (used by engineering tools to identify node on the network) Flickering green (10 Hz) - - Activity Red - Exception error - Flashing red: 1 flash 2 flashes 3 flashes 4 flashes - Configuration error IP address error Station name error Internal error - MN1954WEN Fieldbus types 3-5

3.1.6 Power consumption The maximum overall power consumption of a Fieldbus option card is 1.8 W. See the main MotiFlex e100 installation manual (MN1943WEN) for further details about the option slots power supply and derating information. 3-6 Fieldbus types MN1954WEN

Configuration 4 Configuration 4 4.1 Introduction Configuration and diagnostic tools for the fieldbus option cards are provided by the Mint WorkBench application. This can be found on the Mint Motion Toolkit CD (OPT-SW-001), or downloaded from www.abbmotion.com. 4.1.1 System Config Wizard The System Configuration Wizard provides a simple, structured way to set up the MotiFlex e100, including the fieldbus option card. 1. Start Mint WorkBench and connect to the MotiFlex e100. In the Toolbox on the left of the screen, click the System Configuration icon. 2. Proceed past the standard Configure Process Data - ETHERNET Powerlink screen until the Configure Process Data - <Fieldbus> screen is displayed. The title of this screen changes according to the installed fieldbus option card: 3. Press F1 to display the Mint Help file. This contains detailed information about using the screen to configure process data items. MN1954WEN Configuration 4-1

4.1.2 Connectivity Wizard The Connectivity Wizard allows you to select the node ID (address), IP address and baud rate, if applicable for the installed fieldbus option card. 4.1.3 Spy window The Spy window, which appears on the right of the Mint WorkBench interface, has several tabs at the bottom, one of which is the Network tab. Click the Edit & Debug icon to ensure the Spy window is displayed, then click the Network tab to display live information about the fieldbus option card. 4.1.4 Device characterization To simplify configuration of a network, electronic files (e.g. EDS, GSD etc.) that characterize the different fieldbus options are available on www.abbmotion.com. These files define the behavior and default settings of the fieldbus option card and can be used by configuration tools when setting up a network. 4.1.5 Application Notes A wide range of Application Notes are available on www.abbmotion.com. These describe the step-by-step integration and configuration of various fieldbus option cards in conjunction with typical fieldbus master devices. 4-2 Configuration MN1954WEN

FAQ 5 FAQ 5 5.1 Introduction The following section lists frequently asked questions (FAQ) when using the fieldbus option cards. Does the MotiFlex e100 I m using support the fieldbus option card? MotiFlex e100 hardware revision A units with serial numbers of U080312xxx and greater support the fieldbus option card. All MotiFlex e100 hardware revision B units support the fieldbus option card. If you have a unit with a serial number outside this range, please contact your local sales office. The revision is indicated by the final letter of the part number shown on the product label. Revision A models have no letter, but revision B models and greater show an additional letter, e.g. MFE460A006B. Does the version of Mint WorkBench I m using support the fieldbus option card? The Mint option card is supported in Mint WorkBench build 5600a onwards. There are enhancements in later releases, but all functionality is supported in this release. It is highly recommended to use the latest release to benefit from all the latest features. Go to www.abbmotion.com. Does the MotiFlex e100 firmware I m using support the fieldbus option card? Firmware builds from build 5610 onwards support the fieldbus option card. As with the Mint WorkBench, it is highly recommended to use the latest release to benefit from all the latest features. Go to www.abbmotion.com. Does the fieldbus option carrier card work with all HMS Anybus CompactCom module types? Currently only the DeviceNet, PROFIBUS, EtherNet/IP, Modbus/TCP and PROFINET IO Anybus module types are supported. Support for other module types will be added in the future. Can I use all of the features that the Anybus CompactCom modules support? Not all of the Anybus features are supported. For example, the e-mailing functionality of the Ethernet based module types (EtherNet/IP, Modbus/TCP and PROFINET IO) is not currently supported. Please refer to the documentation in the Mint WorkBench help file for details of the supported functionality. Why does the node ID change when I change the IP address of an Ethernet based fieldbus option? The node ID is directly linked to the last octet of the IP address, i.e. 192.168.100.XXX, where XXX is the last octet and also the node ID. So if you change the IP address the node ID will also change (and vice versa). When I change the node ID, IP address or baud rate of the fieldbus option, why do the new settings not take effect until after a power-cycle? This is because the fieldbus option is only configured by the firmware on power-up. So settings such as node ID, baud rate and IP address are taken from non-volatile memory on the MotiFlex e100, along with process data mappings and update rates which are taken from MN1954WEN FAQ 5-1

the device configuration file (DCF). So any changes to these configuration parameters will require the drive to be power-cycled or reset for them to become active. When I change the node ID of the fieldbus option, why do I lose all of the process data mappings in the System Configuration Wizard? This is because the fieldbus option s process data mappings are stored in the device configuration file (DCF) in a section that specifies the bus number and node ID. If the node ID is changed and the DCF reloaded, the System Configuration Wizard will not find the previous mappings. Mint WorkBench might give the user the option to inherit the mappings from other sections in the DCF (i.e. other node IDs for the same bus) if it detects them. What is process data? Process data is exchanged through a dedicated data channel in the Anybus-CompactCom host protocol, and is normally associated with fast cyclical network I/O. Exactly how this is represented on the network is highly network specific; for example on PROFIBUS, process data correlates to I/O data. How do I map MotiFlex e100 data into the process data? The only way of mapping MotiFlex e100 data into the fieldbus option s process data is by using the System Configuration Wizard in Mint WorkBench. The end product of this wizard is a Device Configuration File (DCF) which is downloaded to the MotiFlex e100 and then executed on power-up. What MotiFlex e100 data can I map into process data? There is a fixed list of data that can be mapped into the fieldbus option s process data. These are listed in the Add Process Data Object dialog in the Mint WorkBench System Configuration Wizard. When using the fieldbus option as a gateway the parameters that are most likely to be mapped are Comms Location and Net data, both of which are arrays of generic user variables. How much data can I map into the process data? There are several limits to take into consideration. Up to 64 data items can be mapped into the write/transmit process data (transmitted by the MotiFlex e100) and the same into the read/receive process data (received by the MotiFlex e100). There are also limits to the number of bytes of process data that can be mapped, as shown in the following table: Fieldbus option card Maximum write/tx process data (transmitted by drive) Maximum read/rx process data (received by drive) Maximum total process data (tx & rx) DeviceNet 243 bytes 243 bytes 486 bytes PROFIBUS 152 bytes 152 bytes 152 bytes EtherNet/IP 243 bytes 243 bytes 486 bytes PROFINET IO 243 bytes 243 bytes 486 bytes Modbus/TCP 243 bytes 243 bytes 486 bytes The number of bytes is affected by the size of each of the data items that has been mapped. How can I trigger an event on a NextMove e100 EPL manager node when I transmit new data from my fieldbus host (e.g. a PROFIBUS PLC) to the fieldbus option card? With firmware build 5615 or greater, NetData and Comms elements can generate events on a change of state when mapped into Ethernet Powerlink. The first 32 NetData elements (0 to 5-2 FAQ MN1954WEN

31) will generate NetDatax events, and the first 10 Comms array elements (1 to 10) will generate Commsx events. With previous versions of firmware it would be necessary to poll the data on the NextMove e100 in order to detect changes. How do I get data from my fieldbus host/master to devices on the Ethernet Powerlink (EPL) network? With Mint WorkBench connected to the MotiFlex e100 (with the fieldbus option), the System Configuration Wizard is used to setup the process data mappings so that the required data from the fieldbus host is mapped to a unique NetData element or Comms element on the MotiFlex e100. Then, with Mint WorkBench connected to the EPL manager node (e.g. NextMove e100), the System Configuration Wizard is used to map the chosen NetData element or Comms element into the MotiFlex e100 s EPL transmit process data. This configuration is stored in the manager node s network device configuration file (DCF). Can my fieldbus master access all of the MotiFlex e100 s parameters through the fieldbus option? Yes, but only in an acyclic manner. The MotiFlex e100 has been designed so that all of its parameters are represented as Ethernet Powerlink objects in the object dictionary. The fieldbus option support in the firmware has been designed to allow access to the object dictionary through something called the Application Data Object (ADO), which effectively exists in the fieldbus option. Each Ethernet Powerlink object is represented by an instance of the Application Data Object, which is called an Application Data Instance (ADI). These ADIs can be directly accessed by the fieldbus host/master using an acyclic request. The form of this acyclic request will depend on the fieldbus in question: Over DeviceNet and EtherNet/IP the ADIs are accessed using explicit messaging through the ADI CIP object (A2h). Over Modbus/TCP the ADIs are accessed via the holding registers (210h upwards) in the pre-defined register map. Over PROFIBUS DP the ADIs are accessed using DP-V1 read and write services and by specifying a slot and index value. Over PROFINET IO the ADIs are accessed using record data read and write services to API 0 (zero). Can I access all of the MotiFlex e100 s parameters through the fieldbus option in another way? Yes, but only on the Ethernet based fieldbus options. All of the MotiFlex e100 s parameters are available through the built in web server on the EtherNet/IP, Modbus/TCP and PROFINET IO fieldbus option types. A simple interface is provided to allow the user access to network configuration and statistics, and all of the fieldbus option s ADIs (i.e. all of the MotiFlex e100 s parameters). The web server can be accessed using a standard web browser on your PC, e.g. Internet Explorer or Mozilla Firefox, simply by connecting the PC to the fieldbus option and then entering the IP address in the address field. Note that you may need to configure the IP address of your PC so that it resides on the same subnet as the fieldbus option, or vice versa. MN1954WEN FAQ 5-3

Can I control motion on the MotiFlex e100 through the fieldbus option? Yes, there are three different methods that can be used to achieve this: 1. For a MotiFlex e100 that is not mapped as an axis on EPL (i.e. not being controlled over EPL) the easiest solution to allow control of the MotiFlex e100 through the fieldbus option is to use the MotiFlex e100 s NetData elements. If enough NetData elements are mapped into the receive and transmit process data, a command type interface can be created between the MotiFlex e100 and the fieldbus host. This interface can then be exercised on the MotiFlex e100 using the on-board Mint programming language (only available in firmware builds 5616 onwards). An application note is available which explains this in further detail; AN00188 PLC control of MotiFlex e100 via Ethernet IP Fieldbus Option Card, available from www.abbmotion.com. 2. For a MotiFlex e100 that is not mapped as an axis on EPL (i.e. not being controlled over EPL) an alternative, but more complicated, solution would be for the fieldbus host to control the MotiFlex e100 directly through the DS402 device profile. The MotiFlex e100 has been designed around the DS402 profile for Drives and Motion Controllers, and is used in both Ethernet Powerlink and CANopen. Therefore DS402 is integral to the MotiFlex e100 s operation, even though it may not be intrinsic to the type of fieldbus being used on the option card. The fieldbus host would need to monitor and control the DS402 state machine, read and write to the relevant MotiFlex e100 objects in mapped process data and possibly also asynchronously (e.g. via explicit messaging or SDO). Please contact technical support if you wish to discuss this functionality. 3. For a MotiFlex e100 that is mapped as an axis on EPL, the easiest solution to allow control of the MotiFlex e100 through the fieldbus option is to map generic MotiFlex e100 NetData elements into both the fieldbus option process data and into the Ethernet Powerlink process data to and from the manager node. This will then form a portal through which the fieldbus host/master can exchange commands and data with the Ethernet Powerlink manager node, which would need to be programmed to encode and decode these commands in order to assert the necessary control over the MotiFlex e100 (with the fieldbus option fitted). Is the update of the fieldbus option s process data always at the specified update rate, or can it be suspended under certain circumstances? The update of process data is normally at the rate specified in the System Configuration Wizard, but it can be suspended for short periods under the following circumstances: When a FACTORYDEFAULTS command is issued by the user on the MotiFlex e100. When the CONTROLRATE is updated. This occurs when using the CONTROLRATE keyword or API, or by using the DRIVERATINGZONE keyword or API. It also occurs when running a new device configuration file (DCF), which happens when powering up the MotiFlex e100 or when the EPL manager node configures the drive over EPL. When the PARAMETERTABLEMODE API is called using the value 2 (_pmapply). When the DRIVETESTPARAMETER keyword or API is called using the value 20 (_dtptrigger_inductance_measurement). This is automatically called as part of the autotuning process. The reason for suspension of process data updates is because the internal high speed interface from the MotiFlex e100 to the fieldbus option card has to be suspended. In fact, all scheduled code in the firmware has to be suspended in the above circumstances because fundamental drive parameters that affect the core of the firmware s functionality may be updated. This suspension may affect the data connection to a fieldbus host/master. 5-4 FAQ MN1954WEN

MN1954WEN FAQ 5-5

5-6 FAQ MN1954WEN

Comments If you have any suggestions for improvements to this manual, please let us know. Write your comments in the space provided below, remove this page from the manual and mail it to: Manuals ABB Ltd Motion Control 6 Bristol Distribution Park Hawkley Drive Bristol BS32 0BF United Kingdom. Alternatively, you can e-mail your comments to: manuals.uk@baldor.com Comment: continued... MN1954WEN Comments

Thank you for taking the time to help us. Comments MN1954WEN

Contact us ABB Oy Drives P.O. Box 184 FI-00381 HELSINKI FINLAND Telephone +358 10 22 11 Fax +358 10 22 22681 www.abb.com/drives ABB Ltd Motion Control 6 Bristol Distribution Park Hawkley Drive Bristol, BS32 0BF United Kingdom Telephone +44 (0) 1454 850000 Fax +44 (0) 1454 859001 www.abb.com/drives ABB Inc. Automation Technologies Drives & Motors 16250 West Glendale Drive New Berlin, WI 53151 USA Telephone 262 785-3200 1-800-HELP-365 Fax 262 780-5135 www.abb.com/drives ABB Beijing Drive Systems Co. Ltd. No. 1, Block D, A-10 Jiuxianqiao Beilu Chaoyang District Beijing, P.R. China, 100015 Telephone +86 10 5821 7788 Fax +86 10 5821 7618 www.abb.com/drives