Towards building an anatomically correct solid eye model with volumetric representation of retinal morphology

Similar documents
Comparison of real-time visualization of volumetric OCT data sets by CPU-slicing and GPU-ray casting methods

Pathology Hinting as the Combination of Automatic Segmentation with a Statistical Shape Model

Pathology Hinting as the Combination of Automatic Segmentation with a Statistical Shape Model

Fuzzy C-means Clustering For Retinal Layer Segmentation On High Resolution OCT Images

Mode-Field Diameter and Spot Size Measurements of Lensed and Tapered Specialty Fibers

OPTICAL COHERENCE TOMOGRAPHY:SIGNAL PROCESSING AND ALGORITHM

Coherent Gradient Sensing Microscopy: Microinterferometric Technique. for Quantitative Cell Detection

The Future of OCT? Swept Source. Todd J. Purkiss, MD, PhD River City Retina Club July 16, 2015

Wavelength scanning interferometry for measuring transparent films of the fusion targets

Light & Optical Systems Reflection & Refraction. Notes

3D OCT imaging in clinical settings: toward quantitative measurements of retinal structures

Correction of refraction. volume deformation measurements

3D SWEPT SOURCE OCT. Very high scanning speed: 30,000 A-Scans/sec. 130,800 A-Scans. Cut plane 16 x 16 x 6 mm. Topo/Pachy Map in 0.3 sec.

FDA 510(k)-cleared OCT system for ophthalmic surgery SEE WHAT YOU VE BEEN MISSING. EnFocus intrasurgical OCT

Quantitative Three-Dimensional Imaging of the Posterior Segment with the Heidelberg Retina Tomograph

Measurement of Highly Parabolic Mirror using Computer Generated Hologram

ksa MOS Ultra-Scan Performance Test Data

Narcissus of Diffractive OpticalSurfaces. Jonathan B. Cohen. ElOp E1ectrooptics Industries Ltd. P.O.B , Rehovot , Israel LINTRODUCTION

Surface and thickness measurement of a transparent film using wavelength scanning interferometry

2011 Optical Science & Engineering PhD Qualifying Examination Optical Sciences Track: Advanced Optics Time allowed: 90 minutes

Image Acquisition Systems

A. K. Srivastava, K.C. Sati, Satyander Kumar alaser Science and Technology Center, Metcalfe House, Civil Lines, Delhi , INDIA

Real Time Process Control with Optical Coherence Tomography

TOTAL INTERNAL REFLECTION BASED ANGLE FILTER FOR SIDE IMAGE MITIGATION IN A CURVED LIGHTGUIDE

LABORATORY SYSTEM FOR X-RAY NANOTOMOGRAPHY

EnFocus Your Upgrade Path to High Performance Intrasurgical OCT

Unsurpassed Wide Field Image Quality

Orthogonal Fabry-Pérot sensor array system for minimal-artifact 3D photoacoustic tomography

Development of a Simulation Method of Three-Dimensional Ultrafine Processing by Femtosecond Laser Shunsuke Nabetani 1, a, Hideki Aoyama 1, b * 1, 2, c

Visual Distortions in Macular Degeneration: Quantitative Diagnosis and Correction

Extracting Wavefront Error From Shack-Hartmann Images Using Spatial Demodulation

Implementing the probe beam deflection technique for acoustic sensing in photoacoustic and ultrasound imaging

ENGR142 PHYS 115 Geometrical Optics and Lenses

A Study of Medical Image Analysis System

Experiment 6. Snell s Law. Use Snell s Law to determine the index of refraction of Lucite.

PHYS 219 General Physics: Electricity, Light and Modern Physics

Ophthalmic Lenses Single use and reusable

Sensor based adaptive laser micromachining using ultrashort pulse lasers for zero-failure manufacturing

Guo, Wenjiang; Zhao, Liping; Chen, I-Ming

Physical properties of prism foil and its pedagogical applications. Faculty of mathematics and physics, University of Ljubljana, Slovenia

Optimal cornea shape design problem for corneal refractive surgery

Measure at the speed of light...

MICHELSON S INTERFEROMETER

Image Formation. Antonino Furnari. Image Processing Lab Dipartimento di Matematica e Informatica Università degli Studi di Catania

EyeTech. Particle Size Particle Shape Particle concentration Analyzer ANKERSMID

The image is virtual and erect. When a mirror is rotated through a certain angle, the reflected ray is rotated through twice this angle.

SWING ARM OPTICAL CMM

Imaging of the Cornea. Arun Brahma

Switzerland ABSTRACT. Proc. of SPIE Vol N-1

PowerMax-Pro kw Sensors

Dr. Larry J. Paxton Johns Hopkins University Applied Physics Laboratory Laurel, MD (301) (301) fax

El- T O O K H Y, Omar

Surface and thickness profile measurement of a transparent film by three-wavelength vertical scanning interferometry

Light and refractive index

Optical Topography Measurement of Patterned Wafers

Lab 5 Microscopy. Introduction. Carrying the Microscope. Depth of Focus. Parts of the Compound Microscope. Magnification

Three-dimensional nondestructive evaluation of cylindrical objects (pipe) using an infrared camera coupled to a 3D scanner

Lab 4 - The Microscope

Reflection and Refraction of Light

Supporting Information: Highly tunable elastic dielectric metasurface lenses

NAME:... REFRACTION. Page 1

Invited Paper. Nukui-Kitamachi, Koganei, Tokyo, , Japan ABSTRACT 1. INTRODUCTION

LIGHT. Descartes particle theory, however, could not be used to explain diffraction of light.

Development of Digital Visualization Tool: Visual Image Simulation (VIS) DigitEyez / Brandon Zimmerman

Null test for a highly paraboloidal mirror

Chapter 33 Continued Properties of Light. Law of Reflection Law of Refraction or Snell s Law Chromatic Dispersion Brewsters Angle

Assembly of thin gratings for soft x-ray telescopes

Polarization of light

Visualization of liquid droplets on a transparent horizontal surface

Fabrication of high quality optical coherence tomography (OCT) calibration artefacts using femtosecond inscription.

NEW OPTICAL MEASUREMENT TECHNIQUE FOR SI WAFER SURFACE DEFECTS USING ANNULAR ILLUMINATION WITH CROSSED NICOLS

Confocal Raman Imaging with WITec Sensitivity - Resolution - Speed. Always - Provable - Routinely

Laser speckle based background oriented schlieren measurements in a fire backlayering front

Reflection & Refraction

City Research Online. Permanent City Research Online URL:

Optics: Laser Light Show Student Advanced Version

Which row could be correct for the colours seen at X, at Y and at Z?

White-light interference microscopy: minimization of spurious diffraction effects by geometric phase-shifting

Computer aided error analysis for a threedimensional precision surface mapping system

Development of Reflector for HR-TFTs

If you are interested in taking advantage of this integrated approach, you must own licensed copies of both ASAP PRO and FDTD Solutions.

Speed of light E Introduction

Lecture 4 Recap of PHYS110-1 lecture Physical Optics - 4 lectures EM spectrum and colour Light sources Interference and diffraction Polarization

specular diffuse reflection.

Segmentation of Three-dimensional Retinal Image Data

Laser Contouring Method for Wall Thickness Metrology on OMEGA Shock Breakout Targets

From Eye to Insight Hand-held, contact-free Optical Coherence Tomography for pediatrics ENVISU C2300 OCT Take OCT to your patient FDA 510(k) Cleared

Chapter 24. Wave Optics. Wave Optics. The wave nature of light is needed to explain various phenomena

The role of light source in coherence scanning interferometry and optical coherence tomography

Signal post processing in frequency domain OCT and OCM using a filter bank approach

Scaling Calibration in the ATRACT Algorithm

LASER SLIT LAMP. Optimized for Retina

Optical Sectioning. Bo Huang. Pharmaceutical Chemistry

LOW-COHERENCE INTERFEROMETRY, AN ADVANCED TECHNIQUE FOR OPTICAL METROLOGY IN INDUSTRY

A NON-IMAGING OPTICAL SYSTEM FOR CHARACTERISATION OF BALL- SHAPED MICRO-INDENTERS

Optics of Vision. MATERIAL TO READ Web: 1.

INFINITY-CORRECTED TUBE LENSES

(A) Electromagnetic. B) Mechanical. (C) Longitudinal. (D) None of these.

Optimization of integrated optic components by refractive index profile measurements

Automatic identification of the temporal retinal nerve fiber raphe from macular cube data

Transcription:

Towards building an anatomically correct solid eye model with volumetric representation of retinal morphology Robert J. Zawadzki a *, T. Scott Rowe b, Alfred R. Fuller c, Bernd Hamann c and John S. Werner a a Vision Science and Advanced Retinal Imaging Laboratory (VSRI) and Dept. of Ophthalmology & Vision Science, UC Davis, 4860 Y Street, Suite 2400, Sacramento, CA USA 95817; b Rowe Technical Design, Inc., 24865 Danafir, Dana Point, CA USA 92629; c Institute for Data Analysis and Visualization (IDAV), Department of Computer Science, UC Davis, One Shields Avenue, Davis, CA 95616 ABSTRACT An accurate solid eye model (with volumetric retinal morphology) has many applications in the field of ophthalmology, including evaluation of ophthalmic instruments and optometry/ophthalmology training. We present a method that uses volumetric OCT retinal data sets to produce an anatomically correct representation of three-dimensional (3D) retinal layers. This information is exported to a laser scan system to re-create it within solid eye retinal morphology of the eye used in OCT testing. The solid optical model eye is constructed from PMMA acrylic, with equivalent optical power to that of the human eye (~58D). Additionally we tested a water bath eye model from Eyetech Ltd. with a customized retina consisting of five layers of ~60 µm thick biaxial polypropylene film and hot melt rubber adhesive. Keywords: Optical coherence tomography; Imaging system; Ophthalmology; Solid eye model; Laser scan systems 1. INTRODUCTION Recent progress in OCT instrumentation has made possible acquisition of volumetric retinal structures within a few seconds, depending on the OCT system s speed and lateral sampling density. This technological evolution is responsible for increasing interest in accurate representation and modeling of volumetric retinal morphology. Over the past five years, our group has been actively developing custom volume visualization software that allows recreation of anatomically correct retinal morphology [1]. An accurate solid eye model (with volumetric retinal morphology) should have many applications in the field of ophthalmology including evaluation of ophthalmic instruments as well as optometry/ophthalmology training. We considered two eye models with volumetric retinal representation. One with anatomically correct representation of threedimensional (3D) retina layers re-created within PMMA acrylic by a laser scan system and the second with a retina consisting of five layers of ~60 µm thick biaxial polypropylene film and hot melt rubber adhesive placed inside a water bath eye model from Eyetech Ltd. Images in the water bath eye model with layered retina are presented. 2. MATERIALS AND METHODS Two different eye models that mimic volumetric representations of retinal structures are described briefly. *rjzawadzki@ucdavis.edu; phone 1 916 734-5839; fax 1 916 734-4543; http://vsri.ucdavis.edu/!""#$%$&' V. 4 (p.1 of 7) / Color: No / Format: Letter / Date: 2010 02 09 08:40:08 PM

2.1. Solid Eye Model The solid optical model eye is constructed from PMMA acrylic, with equivalent optical power (~58D) and axial length of the human eye (see Figure 1). Although PMMA is not a close match to any of the human ocular tissues from an index of refraction standpoint (n=1.485 vs. ~1.35 @!=780 nm), its dispersion Abbe values are (" d = 57.4) [2]. A Coddington style pupil provides for an apparent 8 mm clear aperture, large enough for easy imaging by any ophthalmic instrument. It has one refracting surface and one scanning surface. The scanning surface is slightly aspherical, mirroring the curve of best focus over a 50 degree internal field of view (IFOV), with a base curvature of 12 mm, nearly equivalent to the nominal human eye s retinal curvature [3]. The optical focus curve was designed to be some 300-500 µm anterior to the actual scanning surface, and corresponds to the location of the scanned nerve fiber layer (NFL). The retina on the model eye is constructed by scanning data, layer by layer, from the curvature-corrected 3D model data via a laser scanning system through the scanning surface into the model eye. The shallow depths of material to scan through, plus the fact that the scanning surface is always normal to the internal imaged retinal surface at any given point allows for highly accurate reproduction of the retinal anatomy. Figure 1 shows a visualization of the solid model eye. Fig. 1 Visualization of the solid eye model. Left: Side view; Right: View at the surface to scan. 2.1.1 Volumetric Retina Data Set. The volumetric representation of the retina that was used as an input for the solid optical model was obtained from 3D OCT data acquired in vivo on a normal volunteer eye. We used our standard OCT clinical system [4] to obtain these data. Figure 2 shows a 3D visualization of this data set with the corresponding corrected volume (corrected for OCT scanning beam geometry) that has to be used for the solid optical eye model. Fig. 2 3D Visualization of the retina acquired in vivo. Left: original view; Right: Corrected de-warped volume.!""#$%$&' V. 4 (p.2 of 7) / Color: No / Format: Letter / Date: 2010 02 09 08:40:08 PM

It is essential to use a de-warped (corrected for OCT scanning beam geometry) volumetric representation of the retina. Otherwise during model eye imaging the retinal structure will appear distorted. When we receive the eye model we plan to use it to confirm our OCT imaging system parameters and de-warping algorithm performance [1]. The image below shows the source of OCT B-scan geometry distortion. Fig. 3 Scanning geometry and sampling grid of the OCT retinal system; Left: schematic of the ray s path inside subject s eye for horizontal scanning plane. Right: 2D sampling grid of the OCT system with the axial sampling (#r) and radial sampling (#$) for vertical (V) and horizontal (H) scanning pattern. In order to use the OCT data set for the laser scanning system we had to segment retinal layers and represent them in the solid model format that could be exported to the laser scanning system. Figure 4 shows an OCT B-scan with the corresponding representation that was used in the first round of retina engraving. Additionally the orientation of optical and visual axes with respect to the modeled retina are presented. Fig. 4 Cross-sectional view of the solid eye model (left) and five retinal layers modeled for laser scanner (right) Once we have available the eye model with engraved retina layers we will image it with our OCT system. Figure 5 shows the mechanical components that will allow mounting of the model eye in front of virtually any clinical retinal imaging instrument. Fig. 5 Components of the Solid Eye Model that will be used to mount it in front of any clinical instrument.!""#$%$&' V. 4 (p.3 of 7) / Color: No / Format: Letter / Date: 2010 02 09 08:40:08 PM

2.1.2 The Laser Scanning System. The laser scanning system re-creates an optical retina within the PMMA by extremely precise, localized (spot dia. < 4 µm) changes in index of refraction. The index changes occur by local heating and polymeric crosslinking changes to the PMMA, controlled by both the scan rate and laser power. High power or low scan rates cause micro-vacuoles to be created, thus effectively creating a high local value of #n at that point (pixel). Smaller values of #n s can be created by lower power or higher scan rates, and can approximate the values of #n s present within the retinal layers. Figure 2 shows two examples of art created in both glass and PMMA where this effect is used. Fig. 6 Examples of laser crystal art [5,6], demonstrating the complexity of the structures that can be created by scanning laser. 2.2. Water Bath Eye Model As a second eye model with volumetric retinal representation we tested a modified water bath eye model from Eyetech Ltd with a custom-layered retina. This retina consists of five layers of ~60 µm thick biaxial polypropylene film and hot melt rubber adhesive placed inside water. Figure 7 shows the schematic organization of these retinal layers. Fig. 7 Cross-sectional view of the retina for water bath eye model.!""#$%$&' V. 4 (p.4 of 7) / Color: No / Format: Letter / Date: 2010 02 09 08:40:08 PM

Please verify that (1) all pages are present, (2) all figures are acceptable, (3) all fonts and special characters are correct, and (4) all text and figures fit within the This modified retina is placed inside the water bath eye model replacing its standard retinal plane. Figure 8 shows the water bath eye model and mechanical components that will allow mounting this model eye in front of virtually any clinical retinal imaging instrument. Fig. 8 Left: Water Bath Eye model from Eyetech Ltd. Right: Components of the water bath eye model that are used to mount it in front of any clinical instrument. 3. RESULTS So far, only the water bath eye model could be tested with our OCT system for accuracy of volumetric representation of retinal layers. However before imaging it placed inside the eye model, we imaged it with our OCT microscope [7] which moves the sample on a stage to minimize scanning beam distortions. The image below shows a single OCT B-scan of the layered retina imaged by the OCT microscope (outside model eye) and its 3D visualization. Fig. 9 OCT B-scan of the layered retina imaged by OCT microscope (outside model eye) - top. Visualization of the 3D data set of the layered retina imaged by OCT microscope - bottom.!""#$%$&' V. 4 (p.5 of 7) / Color: No / Format: Letter / Date: 2010 02 09 08:40:08 PM

We placed the layered retina inside the water bath model eye and imaged it with our clinical OCT system. Fig. 10 OCT B-scan of the layered retina imaged inside water bath eye model (top). Scanning beam geometry corrected OCT B-scan of the layered retina shown above. Figure 10 shows native and de-warped B-scans of the volumetric model retina (using our customized visualization software). As can be seen, most of the image distortion could be corrected and an image similar to that obtained with the OCT microscope could be generated. Note that the change in layer appearance is caused by a difference in the OCT focusing plane as well as the presence of surrounding water. 4. CONCLUSIONS We presented two eye models with volumetric representation of the retina to better simulate the real structure of the human eye. Only one of the eye models (water bath eye model) was imaged with OCT and showed potential for representing retinal layers accurately. Several improvements including a curved rather than flat artificial retinal plane should be considered in the next version of this model. Additionally, we were able to test our de-warping software and acquire OCT scanning artifact-free images of retinal structures. ACKNOWLEDGEMENTS Alfred Fuller was supported by a Student Employee Graduate Research Fellowship (SEGRF) via Lawrence Livermore National Laboratory. This research was supported by the National Eye Institute (EY 014743) and Research to Prevent Blindness. REFERNENCES 1. Robert J. Zawadzki, Alfred R. Fuller, Stacey S. Choi, David F. Wiley, Bernd Hamann, John S. Werner Correction of motion artifacts and scanning beam distortions in 3D ophthalmic optical coherence tomography imaging; Proc. SPIE Vol. 6426, 642607 (2007) 2. C. Campbell A test eye for wavefront eye refractors; Journal of Ref. Surgery 21 (2), 127-140 (2005) 3. W. Lotmar Theoretical eye model with aspheric surfaces; J. Opt. Soc. Am., 61 (11), 1522-1529 (1971)!""#$%$&' V. 4 (p.6 of 7) / Color: No / Format: Letter / Date: 2010 02 09 08:40:08 PM

4. Suhail Alam, Robert J. Zawadzki, Stacey S. Choi, Christina Gerth, Susanna S. Park, Lawrence Morse, John S. Werner Clinical Application of Rapid Serial Fourier Domain Optical Coherence Tomography for Macular Imaging; Ophthalmology 113 (8), 1425-1431 (2006) 5. DNA polymerase: http://www.bathsheba.com/crystal/dnapolymerase/ 6. Einstein head: http://www.memorialcrystal.com/how_we_do_it.html 7. Julia W. Evans, Robert J. Zawadzki, Rui Liu, James W. Chan, Stephen M. Lane, John S. Werner Optical coherence tomography and Raman spectroscopy of the ex-vivo retina Journal of Biophotonics 2, 398-406 (2009)!""#$%$&' V. 4 (p.7 of 7) / Color: No / Format: Letter / Date: 2010 02 09 08:40:08 PM