Generic HART DTM for FDT 1.2 compliant Frame Applications Release 4

Similar documents
Generic HART DTM for FDT 1.2 and FDT compliant frame applications Release 6.1

FONT SOFTWARE END USER LICENSE AGREEMENT. We recommend that you print this Font Software End User License Agreement for further reference.

Upgrading BMDM and BMRG Software and MPM, BDS and DCM Firmware

Shimadzu LabSolutions Connector Plugin

Ludlum Lumic Data Logger Software Manual Version 1.1.xx

vippaq Main App. User Guide

Battery Monitor Data Manager Report Generator Software. User s Guide

Quick Start Guide. Model 0260 Secondary Electronics

SensView User Guide. Version 1.0 February 8, Copyright 2010 SENSR LLC. All Rights Reserved. R V1.0

CX Recorder. User Guide. Version 1.0 February 8, Copyright 2010 SENSR LLC. All Rights Reserved. R V1.0

INTELLEX SOFTWARE VERSION 3.1 UPGRADE

Font Software License

User Guide. Version 2.20

Installing Enterprise Switch Manager

Installing Enterprise Switch Manager

GPA Migration Guide

Installation and Configuration Manual. Price List Utilities. for Microsoft Dynamics CRM Dynamics Professional Solutions Ltd 1 / 14

MULTIFUNCTIONAL DIGITAL SYSTEMS. Software Installation Guide

Price List Utilities. For Dynamics CRM 2016

Winnebago Industries, Inc. Privacy Policy

Webfont License End User License Agreement (EULA)

LOGO LICENSE AGREEMENT(S) CERTIPORT AND IC³

AhnLab Software License Agreement

OCTOSHAPE SDK AND CLIENT LICENSE AGREEMENT (SCLA)

Daniel MeterLink Software v1.40

ssj1708 User s Manual Version 1.3 Revised February 2nd, 2009 Created by the J1708 Experts

fontseek.info outofthedark.xyz

MULTIFUNCTIONAL DIGITAL SYSTEMS. Software Installation Guide

SonicWALL CDP 2.1 Agent Tool User's Guide

User s Manual. JAI Control Tool. Operation Manual. Document Version: C Document P/N:10493

FlukeView. Users Manual. Software for ScopeMeter Test Tools

ssi14229 Server User s Manual Created by the UDS Experts! Version 1.0 Revised May 17, 2016

Hitachi ID Identity and Access Management Suite TRIAL USE LICENSE AGREEMENT. between

Network-MIDI Driver Installation Guide

1. License Grant; Related Provisions.

PCMCIA Flash Card User Guide

CX1 Network Accelerometer & Inclinometer User Guide

DME-N Network Driver Installation Guide for M7CL

Analog & Digital Output Module Quick Start Guide

ALL-TEST PRO 33IND PC Software Quick Start Guide

Getting Started with the Clarinet Fingering Font :

Manual NEWBASE WebShot 1.4. Copyright by NEWBASE GmbH, Hamburg, Germany

Online Localization Service

TotalShredder USB. User s Guide

Snapture for Pocket PC For Windows 95/98/ME/2000/XP/2003 and PocketPC

ssi User s Manual Version 1.1 Revised January 7 th, 2009 Created by the ISO Experts

TERMS OF USE FOR NAT TRAVERSAL FUNCTION TRIAL VERSION

Getting Started (No installation necessary) Windows On Windows systems, simply double click the AntPConc icon to launch the program.

PATGuard Time Manager 2

Getting Started (No installation necessary) Windows On Windows systems, simply double click the AntGram icon to launch the program.

KEPServerEx Client Connectivity Guide

ABB Network Partner. User s Manual CAP/REx 500*2.0

HP Worldwide Limited Warranty and Technical Support

CompleteView Video Player User Manual. CompleteView Version 4.6.1

KepserverEx Client Connectivity Guide

If you do not wish to agree to these terms, please click DO NOT ACCEPT and obtain a refund of the purchase price as follows:

End User License Agreement

Westhold Sign Master User Manual. Version

VoiceMaster. User s Guide. NETphone VoiceMaster Release 2.4. for Microsoft NT Servers, VoiceMaster User s Guide 1

IPNexus Server Secure Instant Messaging & Integrated Collaboration

0Introduction. Overview. This introduction contains general information and tips for using your Avaya CD-ROM.

MOTIF-RACK XS Editor VST Installation Guide

Product Manual Select Code Comcode Issue 8 January EasyView Software for the Galaxy Controller

Products: Software, content and digital materials distributed via the Vuzix App Store.

Electronic Control Software User Instructions

Notice to Users. Serial Number

KEPServerEX Client Connectivity Guide

Oracle Binary Code License Agreement for Java Secure Sockets Extension for Connected Device Configuration 1.0.2

CompleteView Video Player User Manual. CompleteView Version 4.5.1

VW INTERFACE. The AutoSoft DMS and Finance Assistant Integration with VW OEM and VCI. The ASI and VW OEM Interface Solution

Emerald. Caller-ID Search Version 1.2. Emerald Management Suite IEA Software, Inc.

VP-UML Installation Guide

Report Viewer Version 8.1 Getting Started Guide

TOOLS for n Version2 Update Guide

Stellar WAB to PST Converter 1.0

InLinK HM Setup Software Installation & Operation Manual

TWAIN 163/211. User Manual

ADN. System Installer. Instruction manual

MOTIF-RACK XS Editor Installation Guide

SD1306. Speed Dome IP Camera. Quick User Guide

The Contour Perfit Mouse Control Panel

SUPPORT SERVICES FOR DGX PRODUCTS TERMS AND CONDITIONS Release Date: August 17, 2017

User Guide. Portable Calibration Module

KEPServerEX Client Connectivity Guide

Installation Guide. ProView. For System Center operations Manager ProView Installation Guide. Dynamic Azure and System Center insights

Terms Of Use AGREEMENT BETWEEN USER AND DRAKE MODIFICATION OF THESE TERMS OF USE LINKS TO THIRD PARTY WEB SITES USE OF COOKIES

KEPServerEX Client Connectivity Guide

INCLUDING MEDICAL ADVICE DISCLAIMER

SOFTWARE GUIDE. ATP-based cleaning verification and tracking system for the health care industry

Stellar Repair for Video

HIGHSOFT SOLUTIONS AS STANDARD LICENSE TERMS AND CONDITIONS 2.2

Mile Terms of Use. Effective Date: February, Version 1.1 Feb 2018 [ Mile ] Mileico.com

Beta Testing Licence Agreement

2.4GHz Wireless Optical Mouse

E-swipe User Guide. Escan Technologies Corporation

ABSOFT Corporation Software License Agreement. Specifically for IMSL FORTRAN 5.0 BUNDLED WITH FORTRAN COMPILERS FROM ABSOFT FOR WINDOWS OR OS X

TERMS OF SERVICE. Hire Torque Tools Victoria ABN: =======================================================================

Ludlum Lumic Calibration Software Manual

Temperature & Humidity SMS Alert Controller

User Guide. Portable Calibration Module

Transcription:

Generic HART DTM for FDT 1.2 compliant Frame Applications Release 4 Copyright ICS Industrielle Computer Systeme GmbH 2007, all rights reserved. Sublicense for brand labeled version granted to Microflex, LLC Brookshire, Texas, USA

License Terms Generic HART DTM Device Type Manager for the parameterization of HART-capable field devices. The Generic HART DTM runs in frame applications that were implemented in compliance with Release 1.2 of the Field Device Tool Specification. Frame applications may be parameterization programs like PACTware, Engineering tools or control systems. The Generic HART DTM runs under Windows 98, NT 4.0, 2000 and XP. The following licensing terms are in effect: 1. License Grant. This License permits you, as purchaser of the Software, to use one copy of the Software solely for your use on one computer per purchased copy of the software. The enclosed documentation ("Documentation") may not be copied. You agree that you will not sublicense, assign, transfer, distribute, pledge, lease, rent or share your rights under this License except with prior written permission from Microflex, LLC. You agree that you will not modify, adapt or translate, or disassemble, decompile, reverse engineer or otherwise attempt to discover the source code of the Software. 2. Microflex, LLC's Rights. You acknowledge and agree that the Software and Documentation (the "Licensed Products") are proprietary products of Microflex, LLC under international copyright law and disclosed to you by Microflex, LLC in confidence. You shall take all reasonable steps to safeguard the Licensed Products. Microflex owns and retains all copyright, trademark, trade secret and other proprietary rights in and to the Licensed Products. This License conveys to you only a non-exclusive and limited right of use, revocable in accordance with the terms and conditions of this License. 3. Limited Warranty. Microflex warrants that for your benefit alone, for ninety (90) days from the day of delivery to you (the "Warranty Period") the Software media, under normal use in a compatible execution environment, will be free from defects in material and workmanship. Any replacement program will be warranted for the remainder of the original warranty period or thirty (30) days from the date of receipt by you, whichever is longer. In no event may you bring any claim, action or proceeding arising out of the warranty set forth in this Article 3 more than six (6) months after the date on which the breach of warranty occurred. 4. Exceptions to Warranties; Disclaimers. EXCEPT FOR THE ABOVE EXPRESS LIMITED WARRANTY, MICROFLEX, LLC DISCLAIMS ANY AND ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOSE. Microflex, LLC does not warrant that the Software, its use, operation or your ability to use the Software will be uninterrupted or error-free or that all Software errors will be corrected. The warranty set forth above shall not apply to any defect or problems caused by any defect in any hardware or software used in combination with the Software, or use of the Software in execution environments not specified in the Documentation. Microflex, LLC does not warrant that the Software or service will meet your requirements or that the operation of the Software will be uninterrupted or error free. MFXGenHARTDTMeng.fm 2

Microflex, LLC's limited warranty is void if a breach of the warranty has resulted from (i) accident, corruption or misuse of the Software; or (ii) acts or omissions by someone other than Microflex, LLC. 5. Exclusive Remedies. You agree that if, during the Warranty Period, a defect in the Software media appears, your exclusive remedy will be, in Microflex, LLC's sole option, to replace the media or to credit the amounts paid by you to Microflex, LLC, if any, and terminate this License. The later remedy is subject to the return of all copies of the Licensed Products. 6. Limitations of Liability. In no event shall Microflex, LLC be liable for any damages to you or any other party whether arising out of contract or from tort including loss of data, profits or business or other special, incidental, exemplary or consequential damages, even if Microflex, LLC has been advised of the possibility of such loss or damages. Microflex, LLC's cumulative liability shall not exceed the license fee paid, if any, for use of this Software and Documentation. This section shall survive termination of this License. 7. Termination. This agreement is in effect until terminated. You may terminate the agreement at any time by destroying all copies of the Software and Documentation and erasing any copies on storage media. The agreement also terminates if you fail to comply with any terms and conditions of this agreement. In such event, you agree to destroy and erase all copies of the Software and Documentation, and Microflex, LLC will be entitled to all remedies in accordance with applicable law. 8. General. This agreement shall be governed by the laws of the United States of America (USA).Microsoft, Windows, Windows NT and Visual Basic are either registered trademarks or trademarks of Microsoft Corporation USA and/or their locations in other countries. All trademarks used in the text are respected. MFXGenHARTDTMeng.fm 3

1. Introduction The Generic HART Device Type Manager (DTM) is used for the parameterization of HARTcapable field devices. Universal and Common Practice Commands are supported which are executed by most HART-devices. A HART-Communicator or a HART-Multiplexer is required for the hardware-sided communication with a HART-device. The software-sided communication is performed via a HART Communication Device Type Manager (ComDTM). A HART ComDTM is offered e.g. for the parameterization software PACTware by the member companies of the PACTware Consortium e.v.. Other frame applications like e.g. control systems of big automation producers contain their own HART ComDTMs. The Generic HART DTM as well as the HART ComDTM must have been implemented according to the Field Device Tool (FDT) Specification Release 1.2 (see /1/), so they can be used in FDT 1.2 conforming frame applications. As the Field Device Tool Specification has been continuously further developed, the component which processes the interfaces between the frame applications is also constantly updated. This component is the DTM Runtime Library, which was developed by ICS GmbH and is used in the DTMs of numerous device manufacturers. The user interface of the Generic HART DTM contains a component for all parameters which was also developed by ICS GmbH and is compliant with the DTM Styleguide of the FDT Specification. The Generic HART DTM comprises several forms to define the DTM functions. These are: Offline Parameterization Online Parameterization Diagnostics Display of Measured Values Trend with Log Functions Calibration of the current signal Print parameter values Save parameter values The user interface of the DTM is available in German, English and French. If the product is unlicensed, the use of all functions of the Generic HART DTM - except Save and Print parameter values - is enabled for 10 minutes. To use the Generic HART DTM again, the project containing the Generic Hart DTM, must be reloaded. The Professional License provides unlimited use of all functions. MFXGenHARTDTMeng.fm 4

2. Layout of the DTM The DTM displays several fields which contain general and special data and are used to control the display and the communication with the field device. Identification The tag numbers and serial numbers of the HART device which is processed by the Generic HART DTM are displayed under the HART logo. The right part of the identification shows the name of the DTM, the manufacturer and the hardware-version of the HART-device, below it the state of the field device, the most recently read value of the primary variable with unit and the company logo of the ICS GmbH. The website of ICS GmbH can be accessed via the logo on the top right if an internet connection is available at the workplace. Navigation A component of the control area is offered for fast navigation between the dialogs of the DTM. All dialogs are displayed in a tree display. You can switch between dialogs using the mouse and the direction keys of the keyboard. Communication In this part of the control area the state of the parameter of the complete DTM and the state of connection between the field device and the DTM are displayed. Furthermore, a cyclic update of parameter values can be set. The licensee is displayed by a tooltip on the paragraph sign. MFXGenHARTDTMeng.fm 5

Parameter area The parameter area displays a group of parameters which were selected from the frame application (e.g. PACTware) via the context menu or from an entry in the navigation. Toolbar The Toolbar contains keys from the left to the right to show and hide the left control area, to read and write parameters from the field device which are associated to the displayed dialog, to start the online-documentation and to print parameter lists. The parameter lists can be selected by means of the menu. MFXGenHARTDTMeng.fm 6

3. Parameter Component The display and editing of parameter values is offered in accordance with the DTM Styleguide (see /2/). The constituents of parameters component are illustrated below: The identification is displayed in the currently selected language. The value is displayed differently depending on the data type. The display is Windows Styleguide-compliant. The unit is taken from the list of HART-units. The list is contained in the DTMdictionary.xml file. The state of the parameter can adopt the following values: Communication error Device error (Tooltip shows detailed description) Range violation Invalid input Parameter must be confirmed Parameter was changed Parameter is dynamic Parameter cannot be changed with current rights Parameter has initial value Parameter was read from project Parameter was read from device Help is offered for each parameter. It is also displayed in short form as a tooltip. Help is displayed when using key combination Shift F1. MFXGenHARTDTMeng.fm 7

In addition, two context menus are offered. The standard menu which corresponds to the type of the displayed value is opened in the context menu of the parameter value. Different menus may be displayed depending on the configuration of the operating system. The context menu which is accessed via parameter names displays a series of default settings for the parameter value depending on the parameter type as well as the call for the help text. MFXGenHARTDTMeng.fm 8

4. Offline Parameterization Offline parameterization is used for the display and entry of all parameters of a field device that can be edited in the Generic HART DTM. The offline parameterization comprises 4 pages. The first page displays the device-identification: The parameter status is displayed in different icons: the description was modified the serial number contains an invalid character (only digits are admissible) the sensor number is too high. All remaining parameters were read from the device. Commands used: #0 Read out device identification #12 Read message #13 Read tag, description and date #14 Read the sensor information of the primary variables #16 Read device serial number MFXGenHARTDTMeng.fm 9

#17 Write message #18 Write tag, description and date #19 Write device serial number The input value is parameterized on the second page of the offline parameterization: Whereas the sensor limits are default values of the device and are therefore unchangeable, the limits of measuring ranges may be user-defined. The unit of the measured value can be selected from the list of the HART units. The list is contained in file DTMDictionary.xml of directory XMLData in the installation directory of the Generic HART DTM. The selected unit is applied to all limiting values and to the measuring span. It also appears in the display of measured values and in the trend. Commands used: #14 Read sensor information of the primary variables #15 Read information of the primary output #35 Write the limiting values of the primary variables #44 Write the primary unit MFXGenHARTDTMeng.fm 10

The parameters damping, current alarm and transfer function are configured for the output. Commands used: #15 Read information of the primary output #34 Write damping values of the primary variables MFXGenHARTDTMeng.fm 11

The protocol parameters are configured and the revisions are displayed for the HART interface. The polling address is written using the HART CommDTM. #0 Read out device identification #59 Enter the number of the answer preambles MFXGenHARTDTMeng.fm 12

5. Online Parameterization The online parameterization comprises the parameters used for setting the measuring range and the current output. The parameters can be read and written directly. During the read or write operation, the parameter values are displayed grey and a modification of the parameters by the user is disabled. MFXGenHARTDTMeng.fm 13

A tooltip or help text can be displayed alternatively for each parameter. Detailed help text can be called by using Shift F1 or via the context menu. Commands used: #15 Read information of the primary output #35 Write limiting values of the primary variables #44 Write primary unit MFXGenHARTDTMeng.fm 14

6. Measured Value Four variables and the current output value are displayed together in a bar graph. The displayed measuring range, an overview bar, the data window and diverse colors can be defined for each scale in a user dialog. The user dialog is displayed via a double-click on the scale. The overview bar shows which view of the total measuring range is displayed by means of the scale. The data window displays the scale value at the pointer position of a scale. Commands used: #3 Read analog output value and dynamic variables with units #15 Read information of the primary output MFXGenHARTDTMeng.fm 15

7. Trend with log functions The current output variable and the four variables can be written to a diagram cyclically and saved as a csv-file. Commands used: #3 Read analog output value and dynamic variables with units #15 Read information of the primary output MFXGenHARTDTMeng.fm 16

The trend diagram can be modified in many parameters by using the property dialog that is displayed by a double-click. When a new archive file is created, the format of the recorded data can be selected in the following form: For additional processing of archived data from csv-formatted files most of all the setting of a suitable list separator is important. The format of the time and date as well as the decimal separators are determined by the respective local version of Windows. The measured data can also be saved to Microsoft databases. MFXGenHARTDTMeng.fm 17

Data that was acquired in the trend chart is written to the selected file by using key Archive Trend. The recorded measured values can be written to the selected file by using the keys Start and Stop or the recording can be discontinued. The archive may, for example, have the following content: Time stamp;pv;status1;current;status2;sv;status3;tv;status4;qv;status5 25.09.07 18:41:03;59,5224800109863;1;13,5235967636108;1;59,528995513916;1;23,9977188110352;1;855,952941894531;1; 25.09.07 18:41:06;59,5132369995117;1;13,5221176147461;1;59,5146942138672;1;23,9959201812744;1;855,953125;1; 25.09.07 18:41:08;59,5112609863281;1;13,5218019485474;1;59,5093536376953;1;23,995246887207;1;855,953125;1; 25.09.07 18:41:10;59,5085372924805;1;13,5213661193848;1;59,5146942138672;1;23,9959201812744;1;855,953308105469;1; 25.09.07 18:41:12;59,5048751831055;1;13,5207796096802;1;59,5013427734375;1;23,9942359924316;1;855,953308105469;1; 25.09.07 18:41:14;59,5073890686035;1;13,5211820602417;1;59,5075988769531;1;23,9950256347656;1;855,953308105469;1; 25.09.07 18:41:16;59,5043106079102;1;13,5206899642944;1;59,5013427734375;1;23,9942359924316;1;855,953430175781;1; The Software Tool TrendAnalyzer fits perfectly for the analysis or the documentation of archived measured values. If, e.g. in the development of field devices, in the production or quality assurance and in cases of warranty when measured curves must be recorded and documented repeatedly, the respective project file is simply called again. For additional information about TrendAnalyzer see http://www.icsgmbh.de/english/datenanalyse/trendana1.htm MFXGenHARTDTMeng.fm 18

8. Diagnostics The diagnostic functions displays the status of the field device: Commands used: #38 Reset display "Configuration changed" #44 Master reset MFXGenHARTDTMeng.fm 19

9. Calibration A wizard is offered to calibrate the current output. It will guide you through the required steps: The calibration can be repeated successively multiple times. Commands used: #40 Set/reset the current output to/from fixed value #45 zero trim of the digital-analog converter #46 span balancing of the digital-analog converter MFXGenHARTDTMeng.fm 20

10. Print parameters All parameters or a subset of the parameters are printed with their names, values, description and status. If the frame application offers a print preview, the printout can be previewed in a window. Microsoft Internet Explorer, at least Version 5.0 must be installed on the PC to display the preview. MFXGenHARTDTMeng.fm 21

11. Literature /1/ PROFIBUS Guideline: Specification for PROFIBUS Device Description and Device Integration, Volume 3: FDT V 1.2; PROFIBUS Guideline Order No. 2.162 /2/ PROFIBUS Guideline: DTM Styleguide, Guideline for the implementation of Device Type Managers (DTMs) for Field Devices; PROFIBUS Guideline Order No. 2.172 MFXGenHARTDTMeng.fm 22