ComCom-Ex. Safety instructions

Similar documents
Hazardous Area Tablet Tab-Ex 01 DZ1 SIM SIM CARD INSTALLATION AL19A

Zone 2/22. Smart-Ex 201 Ex-Handy 209. Safety Instructions

Produktbereich Kommunikation. Ex-TRA 300 Safety instructions

Ex-Handy 05. Safety instructions

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015

PTB 01 ATEX 2064 U, IECEx PTB U. Example / Beispiel / Exemple: Type Operating Instructions

Installation Instruction. HART Add-On Module

Innovations in V6.5 Consolidation

RealWear Inc. All rights reserved. Version

ex-tra 300 analog HeadseTs FoR Zone 1 31

PTB 01 ATEX Example / Beispiel / Exemple. Type Operating Instructions

HD 46 HME 46. Instructions for use

CANopen Object Browser, Version 0.5

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

Instruction Manual FB-606 FB-606 TF. Infrared Manual Remote Control. LJU Automatisierungstechnik GmbH

Safety instructions Overvoltage protection B81-35

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter

Operating Instructions

3. EU-DECLARATION OF CONFORMITY The EU-declaration of conformity can be found at the end of this manual.

CANopen Object Browser, Version 0.2

Technical Data. General specifications. Output type Rated operating distance s n 8 mm

Operating manual. Diagnostic adapter VAS Operating manual Diagnostic adapter VAS Client documentation Revision: 00 Version: 05/2018

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 5 mm

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

PROCESS AUTOMATION INSTRUCTION MANUAL FIELDBUS SURGE PROTECTOR F*-LBF-I1.32 F*-LBF-D1.32

BVS 17 ATEX E 117 X / IECEx BVS X Types 3320, 3321, 3323, 3360, 3361, 3363 AE3320, AE3321, AE3323, AE3360, AE3361, AE3363

7PMDM Server x - Microsoft Windows Phone 8 7P Mobile Device Management. Doc.Rel: 1.0 / Doc.No.: Windows_ Phone 8 _EN

SMARTLINE RM76 Supplementary instructions

PHOENIX CONTACT - 12/2007

PI-EX-ME-2NAM/COC-120VAC

BVS 17 ATEX E 117 X / IECEx BVS X Types 3320, 3321, 3323, 3360, 3361, 3363 AE3320, AE3321, AE3323, AE3360, AE3361, AE3363

PI-EX-ME-2NAM/COC-24VDC

Operating Instructions for Level Switch for Liquids. Model: RFS

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern

V1.0. General Notes. Manufacturer. Axdia International GmbH. Tel: +49(0) 2154 / Formerweg 9. Fax: +49(0) 2154 /

BVS 16 ATEX E 118 X / IECEx BVS X Types 8791, 8792, Additional Instructions. Zusatzanleitung Instruction supplémentaire

Power Quality Recorder

WIR RX15-2 Receiver MHz or 2.8 MHz

PTB 01 ATEX Operating Instructions. Solenoid coil Type AC21 Magnetspule Typ AC21 Bobine magnetique AC21

REGARD mA output module. Installation, operation and maintenance

Manual. Panelmeter EX20xx, EX30xx

YT-870 / 875 Series. Rotork YTC Limited VERSION 1.06

M E M O R A N D U M I.S.

Signal processor MS96 for flow sensors MS96-11EX0-R/230VAC

PPA R37. PPA Select Receiver. Instructions For Use and Care MAN154C

SolConeX extra-low voltage flange socket

THECHARGEHUB.COM. User Manual. For Square & Round Models

End User License Agreement

Zener Barriers Bulletin 937Z

Installation & Operation Manual

Operating instructions LSR-3000

PHOENIX CONTACT - 05/2007

GRP Flameproof Visual Signal Xenon or Steady LED

Metal Position Switch

Options. 24-VDC service power supply. RUN output. No Yes No 24 VDC 70 W NX-PD7001

Data sheet. Constant current DALI LED control gear 80 W Output power ma Output current Intelligent temperature protection.

Badger Meter Europa GmbH. INSTRUCTION MANUAL Deluxe LCD display for the MN series. September Version MN-Deluxe LCD display-09/01-e

SoniChek MC. 99 Washington Street Melrose, MA Phone Toll Free TRIPLETT. Mini Sound Level Meter C Weighted

IPCB42501 / IPCB42551

G3B/G3BD. Model Number Structure. Ordering Information. Solid State Relays Model Number Legend. List of Models

DR7100 SERIES Supplementary instructions

NJ-Series Power Supply Unit NJ-PA/PD

Safety instructions. IECEx TUN Ex ia IIC T6 Gb

EP616. August International Ltd United Kingdom Tel: +44 (0) EN FR DE IT ES

What s New? SAP HANA SPS 07 SAP HANA tailored data center integration. SAP HANA Product Management November, 2013

Refer to attachment for more details. Andreas Meyer

What s New? SAP HANA SPS 07 Fuzzy Search (Delta from SPS 06 to SPS 07) SAP HANA Product Management November, 2013

Telex. User Instructions. Echelon 25XT Noise Reduction Headset

TETRIS 2500 High Impedance Active Probe. Instruction Manual

Loop-powered Transmitter for Thermocouple Type K (NiCr-Ni)

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information

Safety instructions VEGATOR 121, 122

Course to Steer Indicator (Operator Unit)

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

Handheld Reader Writer

MANUAL Surge Protectors

hands-free BTE inductor for mobile phones

Operating Instructions PRO-AB /6.15. Leakage Current Measuring Adapter

MACX MCR-EX-SD LP(-SP)

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

B63/ NS MS. EtherNet/IP LINK

Physikalisch-Technische Bundesanstalt P1B

Start Stop Relay ehb5040x

The EB7-4W plugs onto one- or two-channel speaker or headset stations as illustrated in Figure 1. EB7-4W. Option. 4-Wire. Option

RN.341 MY Interface Card. User Guide

END USER LICENSE AGREEMENT PANDA ANTIVIRUS 2007 / PANDA ANTIVIRUS + FIREWALL 2007 / PANDA INTERNET SECURITY 2007

Operating Instructions

LINE VOLTAGE TESTER CT101 USER S MANUAL. Please read this manual carefully and thoroughly before using this product.

XSP / XSR DMX Splitter / RDM Hub. User Manual

The Smart-Ex 01 DELIVERING MOBILITY IN HAZARDOUS AREAS

Manual Version: V1.00. Video Decoder User Manual

Vibration Sensor Type 640

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

Explosion proof UL certified VoIP telephone. FernTel IP Z2 UL. Tabletop unit. Manual FHF BA /12

INTRINSICALLY SAFE Ex ia PSU TYPE AC36W

Achat 115M full-range speaker. user manual

Conductive Level Controller

Quick Start Guide CJB1950ALAAB

MINI MCR-SL-CVS NC

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

Transcription:

ComCom-Ex Safety instructions 1

Content 1. Application...11 1.1 ATEX & IECEx...11 2. Safety precautions...11 3. Faults and damage...11 4. Safety regulations...12 4.1 Possible devices for connection to ComCom Ex...12 4.2 ComCom Ex interface parameters...12 4.3 Accessories Headsets...12 5. Ex-Data...13 6. Specifications...13 7. Connecting your device...14 8. Repair...14 9. Cleaning, maintenance and storage...14 10. Disposal...14 11. Warranty and liability...15 12. EC Declaration of Conformity and Certificate...16 Note: The current safety instructions, operating instructions, EC Declaration of Conformity and the EC-Type-Examination Certificate can be downloaded from the relevant product page at www.ecom-ex.com, or alternatively they can be requested directly from the manufacturer. 10

1. Application 1.1 ATEX & IECEx The ComCom Ex is an intrinsically safe headset for industrial application in areas with an increased risk of explosion in zone 1, zone 2, zone 21 and zone 22 in accordance with the directive 94/9/EC and the IECEx system. 2. Safety precautions These operating instructions contain information and safety regulations which must be rigorously observed for safe operation in the described conditions. Failure to observe this information and these instructions can have serious consequences or may violate regulations. Please read these operating instructions carefully before starting to use the device! In the event of conflicting information, the details specified in the safety precautions shall apply. In case of doubt (in the form of translation or printing errors), the English version shall apply. 3. Faults and damage If there is any reason to suspect that the safety of the device has been impaired, it must be withdrawn from use and removed immediately from the hazardous-area. Measures must be taken to prevent it from being restarted accidentally. The safety of the device may be compromised, if, for example: - There is visible damage to the housing. - The device has been subjected to excessive loads. - The device has been improperly stored. - The device has been damaged in transit. - Device markings or inscriptions are illegible. - Malfunctions occur. - Permitted limit values have been exceeded. 11

4. Safety regulations Use of the ComCom Ex intrinsically safe headset assumes that the operator observes the conventional safety regulations and has read the certificate of conformity in order to eliminate faulty operation of the device. The following points are to be observed: - Connect the ComCom Ex only to the designated devices stated in Clause 4.1 or to devices meeting the interface parameters in clause 4.2 - Only accessories approved by ecom instruments GmbH refer to clause 4.3 may be used. - It must be ensured that the device is not taken into zones 0 or 20. - The unit may not be used in close proximity to processes generating high charges. - The included belt bag may not be taken into hazardous-areas due to the fact that it may become electrostatically charged. 4.1 Possible devices for connection to ComCom Ex It is allowed to connect the ComCom Ex to the following devices: Ex-Handy 0* EPS 11 ATEX 1 345 X Ex-Handy 0* IECEx EPS 11.0005 X 4.2 ComCom Ex interface parameters For interface parameters see IECEx Certificate of Conformity or EC-Type Examination Certificate (ATEX). You can connect the ComCom Ex if it is allowed to add the interface parameter to your device. 4.3 Accessories Headsets The following approved accessory for the ComCom Ex is available: Serenity SPC Ex in ear shell for hearing protection 12

5. Ex-Data ATEX EC-Type-Examination Certificate no.: EPS 12 ATEX 1 482 X IECEx Certificate of Conformity no.: IECEx EPS 12.0030X Ex-marking: II 2G Ex ib IIC T4 Gb II 2D Ex ib IIIC T130 C Db Ambient temperature: Ta -20 C +55 C Approved for zone 1 and 2, device group II, explosion group IIC, IIB, IIA (explosive gases, vapors or mist), temperature class T4, T3, T2 and T1. Approved for zone 21 and 22, device group III, explosion group IIIC, IIIB, IIIA (combustible flying, non conductive dust and conductive dust), maximum temperature 130 C. 6. Specifications Microphone Pattern: Directional: Impedance: Noise Cancelling: Loudspeaker Pattern: Electret, noise cancelling Omni-directional 2200 Ohm Standard microphone: Up to 90 db ambient noises High noise microphone: Up to 105 db ambient noises Dynamic 13

Impedance: 50 Ohm DC, 100 Ohm @ 1 khz Max. Volume: 100 db (SPL) Additional information Weight: Approx. 22 g 7. Connecting your device To connect your headset to the device, plug in the headset connector to the headphone connector only. - i.e. Ex-Handy 07 8. Repair Repairs are to be conducted by ecom instruments GmbH or by personnel or service centers authorized by ecom instruments GmbH, because the safety of the device needs to be tested after repairs are implemented. The actual repair report sheet can be downloaded from the service area at www.ecom-ex.com. 9. Cleaning, maintenance and storage - It is recommended that you have the functionality and accuracy of the headset inspected by the manufacturer every two years. - Do not exceed the permissible storage temperature range of -20 C +55 C 10. Disposal Old electrical devices as well as historical old electrical devices from ecom instruments GmbH are supplied for disposal at our expense and disposed of free of charge in accordance with European Directive 2002/96/EC and the German electrical law of 16/03/2005. 14

The costs associated with returning devices to ecom instruments GmbH are to be borne by the sender. 11. Warranty and liability In accordance with our general terms and conditions ecom instruments GmbH provides a warranty for this product for a period of 2 years regarding its function and material under the specified and permitted operating and maintenance conditions. This warranty does not extend to products that are used improperly, have been modified, neglected, damaged in accidents or exposed to abnormal operating conditions and inappropriate handling. Any claims under the warranty can be invoked by returning the defective equipment to the manufacturer. We reserve the right to repair, adjust or exchange the device. The aforementioned warranty conditions are the sole and the only right of the purchaser to compensation, are exclusively valid and replace all other contract or legal warranty obligations. ecom instruments GmbH assumes no liability for special, direct, indirect, accompanying or consequential damage as well as losses including the loss of data, independent of whether it was caused by violation of the warranty obligation, lawful or unlawful action, action in food faith or any other action. If the limitation of a legal warranty as well as the exclusion or limitation of accompanying or consequential damage is not permissible in certain countries, it may be that the aforementioned limitations and exclusions are not valid for every purchaser. Should any such clause of these warranty conditions be declared ineffective or unenforceable by a competent court, then the effectiveness or enforceability of any of the other conditions of these warranty conditions shall remain unaffected by such a judgment. 15

12. EC Declaration of Conformity and Certificate The EC Declaration of Conformity is enclosed with the sales packaging as a separate document. Please also observe the information provided underneath the table of contents. 16

Copyright 2012 ecom instruments GmbH. Der Inhalt dieses Dokuments darf ohne vorherige schriftliche Genehmigung durch die ecom instruments GmbH in keiner Form, weder ganz noch teilweise vervielfältigt, weitergegeben, verbreitet oder gespeichert werden. Der Inhalt dieses Dokuments wird so präsentiert, wie er aktuell vorliegt. Die ecom instruments GmbH übernimmt weder ausdrücklich noch stillschweigend irgendeine Gewährleistung für die Richtigkeit oder Vollständigkeit des Inhalts dieses Dokuments, einschließlich, aber nicht beschränkt auf die stillschweigende Garantie der Markttauglichkeit und der Eignung für einen bestimmten Zweck, es sei denn, anwendbare Gesetze oder Rechtsprechungen schreiben zwingend eine Haftung vor. Die ecom instruments GmbH behält sich das Recht vor, jederzeit ohne vorhergie Ankündigung Änderungen an diesem Dokument vorzunehmen oder das Dokument zurückzuziehen. The contents of this document, either in part or in their entirety, may not be reproduced, forwarded, distributed or saved in any way without ecom instruments GmbH prior written consent. The contents of this document are presented as they currently exist. ecom instruments GmbH does not provide any express or tacit guarantee for the correctness or completeness of the contents of this document, including, but not restricted to, the tacit guarantee of market suitability or fitness for a specific purpose unless applicable laws or court decisions make liability mandatory. ecom instruments GmbH reserves the right to make changes to this document or to withdraw it any time without prior notice. PA000465/ Druckauflage / 11 / 2012 WEEE-Reg.-Nr. DE 934 99306 500046AL01A00 12 / 2011 Änderungen vorbehalten! Subject to change without notice! ecom instruments GmbH Industriestraße 2 97959 Assamstadt Germany Tel.: +49 (0) 62 94 / 42 24-0 Fax: +49 (0) 62 94 / 42 24-100 E-Mail: sales@ecom-ex.com www.ecom-ex.com 60