RF Characterization Report

Similar documents
RF Characterization Report

Agilent USB3, Slide - 1. Agilent. USB3 Test Fixture Characterization. 10 MHz to 20 GHz March 12,

Labs. Introduction. Application Notes

Labs. Introduction. Application Notes

Connectors. High Performance to 65 GHz. Applications. PDF Volume 1. Click Here for Table of Contents Click Here for Specifications

Direct Connection of OML Frequency Extenders to Keysight s PNA-C (E836xC) VNA for 1-Path 2-Port S-Parameter Measurements

SPICE Model Validation Report

Product Specification

AKELA Vector Network Analyzer (VNA) Quick Start Guide

High Speed Characterization Report. DVI-29-x-x-x-xx Mated With DVI Cable


SMA - 50 Ohm Connectors

Series PC 3.5 precision subminiature connectors

5 Performance Verification

Agilent ENA RF Network Analyzer

GT Micro D High Speed Characterization Report For Differential Data Applications. Micro-D High Speed Characterization Report

SMA - 50 Ohm Connectors

TAPR GPS Kit USER S GUIDE

SMP / SMP-COM / SMP-MAX series R222

SERIES MCX 50 MICRO MINIATURE CONNECTORS

Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2

AgilentTechnologies TS-50 RF Shielded Test Fixtures

TTR500 Series Vector Network Analyzers Demonstration Guide

The EAD Pocket Guide innovative multiband antenna solutions Unit 19, Hillcrest Way Buckingham Industrial Park Buckingham MK18 1HJ.

CBL Starter Cable Kit for DuraNAV System

Agilent Technologies Advanced Signal Integrity

GMS Interconnect Series Product Information

802.3cb PMD and Channel. Anthony Calbone 3/14/2016

Automotive Ethernet BroadR-Reach

TNC SERIES Miniature Coaxial Connectors

Agilent PNA Series Microwave Network Analyzers

Keysight E6964A Automotive Ethernet MDI S-parameter Compliance Solution

RF & MW Connectors RF & MW Adapters RF Connectivity. RF & MW Connectors

Awareness Brochure. New Standards For Precise Component, Semiconductor and Material Measurements. Expanded LCR Meter Performance to 1 GHz!

SMA Connectors Series

Corona 70,000 Ft. Permeability Risetime Degradation (Mated Pair) 2.0 max MH z

Agilent 87222C/D/E Coaxial Transfer Switches dc to 26.5, 40, 50 GHz Product Overview

SECTION 12 SSMA/SSMB/SSMC R121/R203/R202 SIMPLIFICATION IS OUR INNOVATON. Visit for more information

RF switch network. RFB 2000, RFC 2010 or 2020

Keysight MOI for USB 2.0 Connectors & Cable Assemblies Compliance Tests

Keysight MOI for USB Type-C Cable Assemblies Compliance Tests Using Keysight M937XA Multiport PXIe VNA

8700 SERIES. narda OPERATION MANUAL DIGITAL METER CALIBRATION FIXTURE. Safety Test Solutions P/N an L3 communications company

Technical Specifications May 2003

Our Most Important Connection is with You. SECTION 3. Board-to-Board: MMBX / SMP-MAX R223 / R222M

MCX Connectors. Alphabetical Index. Johnson Components P.O. Box 1732 Waseca, MN Fax:

E5071C Adjustment Program. <Agilent Service Center Use Only> Operation Manual. Second Edition. Agilent Part No. N/A

Agilent RF Network Analyzers PNA Series

Dimensions (inch) 3.74 x 1.45 x.95. PMA1-08S 70 MHz -10 GHz Inline Power Monitor with SMA Connectors 1

11525A 11524A

INCHES (MILLIMETERS) CUSTOMER DRAWINGS AVAILABLE ON REQUEST

TEST / PRODUCTION SOCKETS & ADAPTERS for BGA LGA QFN QFP SOIC PLCC LCC PGA Flat Pack and others

TC-5972DP Pneumatic Shield Box

What We Do. Fixturing and Fixture Removal for Multiport Devices with Non-Standard RF Interfaces. Fully automate for: Speed, Accuracy, Ease of Use

RF Connectors Technical Data Sheet. Gold over Nickel Plated Brass Contact. Size 0.5 in [12.7 mm] . Weight lbs [2.27 g].

Southwest Microwave, Inc. Tempe, Arizona, USA +1 (480) mm (V) Series DC to 67.

OSMP Microminiature Push-On Coaxial Connectors

REPORT OF ELECTROMAGNETIC SUSCEPTIBILITY TESTS PERFORMED ON GPS ANTENNA PART NUMBER 42G1215A-XT-1-N PREPARED FOR:

Dimensions (inch) 3.74 x 1.45 x.95. PMA1-03S 70 MHz - 3 GHz Inline Power Monitor with SMA Connectors 1

A simple method to characterize and accurately remove the effects of push-on connectors. O.J. Danzy Application Engineer

Super Coaxial Micro-Plugs and Receptacles

Software Release Notes

PicoVNA. USB vector network analyzer. Quick Start Guide

TC-5972D Shield Box. Features. High RF Shielding. Easy Opening/Closing of lid. EMI filter on all Data and DC lines. Customizable Data connections

Agilent Technologies S-Parameter and TDR Impedance Measurement Solution Summary

S3101 Cable & Antenna Tester Datasheet

HSD / USB-Mini / MX-Connectors for differential signal transmission

Applications & Features, Type SSMP When using blind mate connectors in an application, careful consideration has to be given to choosing the right con

TC-5921A Shield Box. Features. High RF Shielding. Easy Opening/Closing of lid. EMI filters on all Data and DC lines

Keysight N7015A/16A Type-C Test Kit. User Guide

Agilent Upgrade Guide for the 8510 Vector Network Analyzer Product Note

FIELD TESTER CAPABILITY FOR BALANCE MEASUREMENT

SMK Connectors. General Description. Contents (Click on any line to go to the indicated page) Test Data

Features. High RF Shielding. Easy Opening/Closing of lid. EMI filters on all Data and DC lines. Easily customizable to meet various test needs

spinner Measurement & Calibration equipment for network analyzers

Accumeasure TM Capacitance Probes

Cannon 50 Ohm Connectors

Attachment plug with surge protection for coaxial signal interfaces. Connection: N connector, male/female

Features. Reliable High RF Shielding. Pneumatic control of lid open-close and optional test fixture motions

CompuScope Ultra-fast waveform digitizer card for PCI bus. APPLICATIONS. We offer the widest range of

Features. High RF Shielding. Easy Opening/Closing of lid. EMI filters on all Data and DC lines. Easily customizable to meet various test needs

ATEC (2832) Models 8757A, 85027A/B/C, 85020A/B

SLC ultra low jitter Clock Synthesizer 2 MHz to 7 GHz

Installation Note. Agilent Technologies 85105A Option 50 Installation Instructions for RF Switch Replacement Kit

Up to now many different ways of connecting and locking have been used. So the aim of the FAKRA standard

SMA SERIES COAXIAL CONNECTORS

TSML-W Radio Network Analyzer

Tx/Rx Globalstar Helix Antenna, P/N: 73G1625LL-A1-XS-1F1: Pictures, Outline Drawing, Specification, Part List, Part Drawing and Test Data

pickeringtest.com B Microwave Multiplexer Module

Microwave Gilbert Push-on Interconnects

Application Note FOR SMA Calibration Kit for VNA. LCAL06A A female calibration kit and used for DC ~ 6.0 GHz VNA test cable with male end connector.

Pressure sensor For highest pressure applications to 15,000 bar Model HP-2

Calibration kit coefficients -the saga continues

VITA 67 Series. Ideal For Blind Mate Applications. Electrical, Mechanical & Environmental Specifications

/June/2014 Rev C

Product Information. Inductive Proximity Switches IN

Build a Wholesome WLAN Infrastructure with ZyXEL Selected Accessories

Modular Block Converter Systems

E2655C Probe Deskew and Performance Verification Kit

Modular Connector System with High Power, Signal, Fibre-Optic, Coaxial Contacts and Pneumatic Valves

Agilent 85130C NMD 3.5 mm to Type-N Adapter Kit

Transcription:

RF174 Series Cable Assemblies RF174-01SP1-01SP1-0306 RF174-01RP1-01RP1-0308 RF174-01BJ1-01BJ1-0306 RF174-01BR1-01BR1-0306 RF174-02SJ1-02SJ1-0307 RF174-02RP1-02RP1-0307 RF174-02SP1-02SP1-0307 RF174-03SP1-03SP1-0310 RF174-07RP1-07RP1-0310 RF174-07BJ1-07BJ1-0303 RF174-01SB1-01SB1-0306 RF174-01SR1-01SR1-0306 Description: RF Cable Assembly, RG174 Cable Samtec Inc. WWW.SAMTEC.COM Phone: 812-944-6733 520 Park East Blvd. 1-800-SAMTEC-9 (US & Canada) Fax: 812-948-5047 New Albany IN 47151-1147 USA Samtec, Inc. 2005 All Rights Reserved

Table of Contents Test Setup Information... 1 Scope:... 1 Product Description:... 1 Test Calibration:... 2 Adapter Use:... 2 Definition of Assembly Under Test:... 2 Port Designations:... 2 Legend for Plots:... 2 Results Summary... 3 RF174-01SP1-01SP1-0306... 3 RF174-01RP1-01RP1-0308... 4 RF174-01BJ1-01BJ1-0306... 5 RF174-01BR1-01BR1-0306... 6 RF174-02SJ1-02SJ1-0307... 7 RF174-02RP1-02RP1-0307... 8 RF174-02SP1-02SP1-0307... 9 RF174-03SP1-03SP1-0310... 10 RF174-03RP1-03RP1-XXXX... 11 RF174-04SP2-04SP2-XXXX... 12 RF174-04BJ2-04BJ2-XXXX... 13 RF174-05SP2-05SP2-XXXX... 14 RF174-05BJ2-05BJ2-XXXX... 15 RF174-06BJ2-06BJ2-XXXX... 16 RF174-07SP1-07SP1-XXXX... 17 RF174-07RP1-07RP1-0310... 18 RF174-07BJ1-07BJ1-0303... 19 RF174-13GP1-13GP1-XXXX... 20 RF174-13GJ1-13GJ1-XXXX... 21 RF174-01SB1-01SB1-0306... 22 RF174-01SR1-01SR1-0306... 23 Instrument Setup:... 24 Test Fixture:... 24 Samtec Inc. WWW.SAMTEC.COM Phone: 812-944-6733 520 Park East Blvd. 1-800-SAMTEC-9 (US & Canada) Fax: 812-948-5047 New Albany IN 47151-1147 USA Samtec, Inc. 2005 Page:ii All Rights Reserved

Test Setup Information Scope: To perform characterization tests, Insertion Loss, Return Loss and Voltage Standing Wave Ratio. Product Description: The table below presents a description of the different RF174 series cable assemblies that were tested Part Number Length Termination End 1 Termination End 2 RF174-01SP1-01SP1-0306 306mm SMA, Straight Plug SMA, Straight Plug RF174-01RP1-01RP1-0308 308MM SMA, RA Plug SMA, RA Plug RF174-01BJ1-01BJ1-0306 306mm SMA, Straight Jack SMA, Straight Jack RF174-01BR1-01BR1-0306 306mm SMA, Straight Jack, Reverse Polarity SMA, Straight Jack, Reverse Polarity RF174-02SJ1-02SJ1-0307 307 mm MCX, Straight, Jack MCX, Straight, Jack RF174-02RP1-02RP1-0307 307 mm MCX, Right Angle, Plug MCX, Right Angle, Plug RF174-02SP1-02SP1-0307 307 mm MCX, Straight, Plug MCX, Straight, Plug RF174-03SP1-03SP1-0310 310 mm MMCX, Straight, Plug MMCX, Straight, Plug RF174-07RP1-07RP1-0310 310 mm SMB5, Right Angle, Plug SMB5, Right Angle, Plug RF174-07BJ1-07BJ1-0303 303 mm SMB5, Straight, Jack SMB5, Straight, Jack RF174-01SB1-01SB1-0306 306mm SMA, Straight Jack, Sealed SMA, Straight Jack, Sealed RF174-01SR1-01SR1-0306 306mm SMA, Straight Jack, Sealed, Reverse Polarity SMA, Straight Jack, Sealed, Reverse Polarity Page:1

Test Calibration: Calibration is performed using Agilent electronic calibration module, PN 85092-60010 to the calibration point below. Any adapters beyond this point are included in the measurements. Adapter Use: (Sample setup of adapters, actual setup not depicted.) Each port uses at least one precision adapter capable of mating to the assembly under test. Any supplementary adapter will contribute additional electrical characteristics to the measured data. Any use of additional adapters is noted. Definition of Assembly Under Test: The performance characteristics include the interface with adapters. Port Designations: The connector attached to port 1 of the VNA is End 1 from the part number callout. Insertion Loss is measured using S21 and Return Loss / VSWR is measured using S11. Legend for Plots: 5 samples were tested. Only the min/max plots are shown for clarity in this report. Page:2

Results Summary RF174-01SP1-01SP1-0306 Page:3

RF174-01RP1-01RP1-0308 Page:4

RF174-01BJ1-01BJ1-0306 Page:5

RF174-01BR1-01BR1-0306 Page:6

RF174-02SJ1-02SJ1-0307 Page:7

RF174-02RP1-02RP1-0307 Page:8

RF174-02SP1-02SP1-0307 Page:9

RF174-03SP1-03SP1-0310 (Included in measurements is a SMA to MMCX precision adapter on both ports) Page:10

RF174-03RP1-03RP1-XXXX Test not performed, please contact RF@samtec.com for more information. Page:11

RF174-04SP2-04SP2-XXXX Test not performed, please contact RF@samtec.com for more information. Page:12

RF174-04BJ2-04BJ2-XXXX Test not performed, please contact RF@samtec.com for more information. Page:13

RF174-05SP2-05SP2-XXXX Test not performed, please contact RF@samtec.com for more information. Page:14

RF174-05BJ2-05BJ2-XXXX Test not performed, please contact RF@samtec.com for more information. Page:15

RF174-06BJ2-06BJ2-XXXX Test not performed, please contact RF@samtec.com for more information. Page:16

RF174-07SP1-07SP1-XXXX Test not performed, please contact RF@samtec.com for more information. Page:17

RF174-07RP1-07RP1-0310 Page:18

RF174-07BJ1-07BJ1-0303 Page:19

RF174-13GP1-13GP1-XXXX Test not performed, please contact RF@samtec.com for more information. Page:20

RF174-13GJ1-13GJ1-XXXX Test not performed, please contact RF@samtec.com for more information. Page:21

RF174-01SB1-01SB1-0306 Page:22

RF174-01SR1-01SR1-0306 Page:23

Instrument Setup: Network Analyzer Agilent E5071C ENA Series (9 KHz - 8.5 GHz Range) Mechanical Calibration Kit 85032F Electronic Calibration Kit 85092-60010 Averaging Factor 4 Smoothing Off IF Bandwidth 300 Hz Sweep Start 5 MHz Sweep End 8.5 GHz Points 601 Test Fixture: (Typical set-up, actual part not depicted.) Page:24