SmartOnline 20kVA On-Line Double-Conversion UPS, N+1, 14U Rack/Tower, 208/120V or 240/120V NEMA & C19 outlets MODEL NUMBER: SU20KRT-1TF Description Tripp Lite SU20KRT-1TF 20,000VA / 20kVA / 18,000 watt online, double-conversion UPS system offers complete power protection for critical server, network and telecommunications equipment in a 14U rack/tower configuration. This system delivers complete N+1 redundancy when used at loads up to 10kVA, and non-redundant operation at loads between 10 and 20kVA. Fault-tolerant auto-bypass prevents unexpected service interruptions during UPS overload or internal fault conditions. Included parallel PDU with manual bypass switching enables hot-swappable replacement of all major UPS system components in both N+1 and combined operating modes. Enhanced availability, fault tolerance and simple hot-swap replacement options make this UPS ideal for advanced networking applications in data centers, computer rooms, network closets and rugged industrial locations. Features Tripp Lite SU20KRT-1TF 20kVA, 20,000VA / 18,000 watt on-line, double-conversion UPS system in 14U total rack/tower configuration Unique configuration offers 20kVA non-redundant operation and automatic N+1 redundancy at load levels of 10kVA and under Included Parallel PDU with manual bypass switch enables hot-swap replacement of power modules at any supported load level Hardwire input; 2 L6-30R (208/240v), 8 C19 (208/240v), 8 5-15/20R (120v) and 4 5-15R (120v) outlets Maintains full-time sine wave output within 2% of selectable 200/208/220/230/240V & 120V nominal Expandable runtime with optional external battery packs Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual) Battery independent restart Highly efficient economy mode option Optional SNMPWEBCARD, RELAYIOCARD and RELAYIOMINI interface modules available (RELAYIOMINI requires removal of USB interface module) Applications utilizing the optional network communications card require two SNMPWEBCARD accessories (install one per included power module) HID-compliant USB interface 1 / 6 Highlights 20kVA / 20,000VA / 18,000W on-line double-conversion UPS; 0.9 power factor 208/120V or 240/120V 60Hz output; Economy mode option Hot-swap power and battery modules, N+1 fault tolerance at loads up to 10kVA USB, RS232 & EPO ports; support for SNMP/WEB and contact-closure card options Front panel LEDs with detailed LCD monitoring and control screen Expandable runtime with optional external battery packs Hardwire input (3 wire); L6-30R, C19, 5-15/20R & 5-15R outlets Package Includes Two SU10000RT3UPM UPS power modules Two BP240V10RT3U battery packs One SU6000XFMR2U 208/240V to 120V transformer SUPDMB20K parallel PDU with Bypass switch 4-post rackmount installation kit PowerAlert software and complete cabling
Includes Free PowerAlert monitoring software; PowerAlert LOCAL, PowerAlert NSA and PowerAlert NMS for monitoring up to 250 SNMP-enabled UPS, PDU and other networking devices Optional 2POSTRMKITHD supports installation in 2 post 19 inch racks (6 required) Optional 2-9USTAND supports upright tower placement (2 required) Supports Emergency Power Off (EPO) via built-in interface Front panel LEDs and LCD readout with scroll controls LED / LCD display panel rotates for viewing in rackmount or tower configurations External battery packs are field replaceable and hot swappable Specifications OUTPUT Output Capacity Details Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as load levels are reduced to 95% or less Output Volt Amp Capacity (VA) 20000 Output kva Capacity (kva) 20 Output Watt Capacity (Watts) 18000 Output kw Capacity (kw) 18 Power Factor 0.9 Nominal Output Voltage(s) Supported Nominal Voltage Details Frequency Compatibility Frequency Compatibility Details Output Voltage Regulation (Line Mode) Output Voltage Regulation (Economy Line Mode) Output Voltage Regulation (Battery Mode) UPS Output Receptacles Output Receptacle Details Output Circuit Breakers Output AC Waveform (AC Mode) Output AC Waveform (Battery Mode) 120V; 208V; 240V Power Module supports 208 or 240V nominal in this configuration controlled via front panel LCD interface; included step-down transformer supports 120V output (set rear panel dipswitch on transformer module to appropriate 208 or 240V input setting) 60 Hz Output frequency regulation +/- 0.05Hz (free running) +/- 2% +/- 10% +/- 2% 4 5-15R outlet(s); 8 5-15/20R outlet(s); 2 L6-30R outlet(s); 8 C19 outlet(s) Total 120V output is limited to 4992 watts for 208V input and 5760 watts for 240V input. Additional 120V capacity is available with the addition of one SU6000XFMR2U step-down transformer. POWER MODULE: Two built-in 30A breakers protect one L6-30R outlet each, Eight built-in 20A breakers protect one C19 outlet each; TRANSFORMER MODULE: Two 15A breakers protect 2 5-15R outlets each, Two 20A breakers protect 4 5-15/20R outlets each Sine wave Pure Sine wave 2 / 6
INPUT Rated input current (Maximum Load) Nominal Input Voltage(s) Supported UPS Input Connection Type 108A (208V), 93.6A (240V) 208V AC; 240V AC Hardwire UPS Input Connection Description 3 wire single phase input (L1, L2, G) Recommended Electrical Service 120A @ 200V-240V (L, N, PE), or 125A @ 200V, 208V, or 240V (L1, L2, G) Input Phase Single-Phase BATTERY Full Load Runtime (min.) Half Load Runtime (min.) Expandable Battery Runtime External Battery Pack Compatibility Expandable Runtime Description 4.3 minutes (18,000 watts) 12.5 minutes (9000 watts) Runtime is expandable with external battery packs BP240V10RT3U; BP240V557C-1PH; BP240V787C-1PH; BP240V1037C-1PH; BP240V1407C-1PH For best results, add external batteries in multiples of two so that both included 10kVA power modules have an equal number and type of connected battery packs DC System Voltage (VDC) 240 Battery Recharge Rate (Included Batteries) Battery Replacement Description 6 hours from 10% to 90% (typical, full load discharge) Hot-swappable, user replaceable external battery packs VOLTAGE REGULATION Voltage Regulation Description Overvoltage Correction Undervoltage Correction 2% output voltage regulation in standard online, double-conversion mode Corrects overvoltages up to 300V Corrects undervoltages as low as 100V LEDS ALARMS & SWITCHES LED Indicators Front Panel LCD Display Audible Alarm Alarm Cancel Operation Switches 6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats; LCD Display supports ENGLISH, FRENCH, GERMAN, ITALIAN, SPANISH and PORTUGUESE (see manual) Unique audible alarms for all major UPS, environmental and power conditions (see manual) Alarm cancel switch 2 Switches control off/on power status and alarm-cancel/self-test operation; 2 additional switches support set and execute scrolling LCD functions; bundled PDU includes bypass switch to enable hot-swap UPS power module replacement SURGE / NOISE SUPPRESSION 3 / 6
UPS AC Suppression Response Time EMI / RFI AC Noise Suppression Instantaneous Yes PHYSICAL Included Mounting Accessory Description Installation Form Factors Supported with Optional Accessories Optional Mounting Accessory Notes Primary Form Factor UPS Power Module Dimensions (hwd, in.) UPS Power Module Dimensions (hwd, cm) Installed Whole System Maximum Rack Depth (in.) Installed Whole System Maximum Rack Depth (cm) Rack Height Secondary Form Factor 5 sets of adjustable 4 post rack rails included (one for each included 2U/3U module) 2 post rackmount (2POSTRMKITHD); Tower (2-9USTAND) Qty 5 2POSTRMKITHD required; Qty 2 2-9USTAND required Rackmount 5.14 x 17.5 x 25.82 13.1 x 44.5 x 65.6 32.5 82.6 14U Tower UPS Power Module Weight (lbs.) 44.1 UPS Power Module Weight (kg) 20 UPS Dimensions Details Stepdown Transformer Dimensions (hwd / in.) Stepdown Transformer Dimensions (hwd / cm) Includes 2 SU10000RT3UPM UPS/Power modules and 2 BP240V10RT3U Battery packs; Listed weights and dimensions for UPS/Power module and Included battery pack each refer to a single unit 3.5 x 17.5 x 21.8 8.89 x 44.4 x 55.4 Stepdown Transformer Weight (lbs.) 72.6 Stepdown Transformer Weight (kg) 33 Included Battery Pack Dimensions (hwd / in.) Included Battery Pack Dimensions (hwd / cm) 5.25 x 17.5 x 25 13.3 x 44.5 x 63.5 Included Battery Pack Weight (lbs.) 158.7 Included Battery Pack Weight (kg) 72 UPS Shipping Dimensions (hwd / in.) 37.5 x 40.25 x 51 UPS Shipping Dimensions (hwd / cm) 95.3 x 102.2 x 129.5 Shipping Weight (lbs.) 781 4 / 6
Shipping Weight (kg) 354.6 Cooling Method UPS Housing Material Fans Steel ENVIRONMENTAL Operating Temperature Range Storage Temperature Range Relative Humidity +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius 0 to 95%, non-condensing AC Mode BTU / Hr. (Full Load) 6830 AC Economy Mode BTU / Hr. (Full Load) AC Mode Efficiency Rating (100% Load) AC Economy Mode Efficiency Rating (100% Load) Operating Elevation (ft.) Audible Noise Operating Elevation (m) 2550 87% 96% 0-3000m (0 to 10,000 ft.) 60 dba at front side 1 meter 0-3000 m COMMUNICATIONS Communications Interface Network Monitoring Port Description PowerAlert Software Communications Cable WatchDog Compatibility USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface Applications utilizing the optional network communications card require two SNMPWEBCARD accessories (install one per included power module);additional contact closure support with optional RELAYIOCARD and RELAYIOMINI interface cards; RELAYIOMINI installation requires removal of panel containing USB ports Included USB, DB9 serial and EPO cables included Supports Watchdog application, OS and hard-reboot restart options for remote applications LINE / BATTERY TRANSFER Transfer Time Transfer Time (Economy Mode) Low Voltage Transfer to Battery Power (Setpoint) High Voltage Transfer to Battery Power (Setpoint) No transfer time (0 ms.) in online, double-conversion mode 8 milliseconds typical power failure response in optional economy mode 100V 300V SPECIAL FEATURES Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported 5 / 6
Economy Mode Operation High Availability UPS Features Green Energy-Saving Features Optional economy mode enables high efficiency bypass operation with a maximum output voltage variation of +/-10%. Double conversion mode is automatically restored as mains voltage varies beyond +/-10% with less than 1 millisecond transfer time between modes. Automatic inverter bypass; Manual bypass switch; Detachable hot-swap PDU; Hot swappable UPS power module; Hot swappable batteries High efficiency economy mode operation; Support for daily startup and shutoff; Schedulable daily hours of economy mode operation CERTIFICATIONS UPS Certifications UPS Certification Details Tested to UL1778 (USA); Tested to CSA (Canada); Meets FCC Part 15 Category A (EMI); ROHS (Restriction of Hazardous Substances) IEC 61000-4-5 1995 B Surge Immunity WARRANTY Product Warranty Period (Worldwide) Connected Equipment Insurance (U.S., Canada & Puerto Rico) 2-year limited warranty $250,000 Ultimate Lifetime Insurance 2014 Tripp Lite. All rights reserved. All trademarks are the sole property of their respective owners. Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice. Photos may differ slightly from final products. 6 / 6