STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions

Similar documents
CNVT-USB-RS485 MODBUS TO USB CONVERTER. Operating instructions

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

RТTH DUAL ROOM SWITCH

MVS RAIL ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions

RXTP ROOM TEMPERATURE

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

HPS-M -2 DIFFERENTIAL PRESSURE TRANSMITTER. Mounting and operating instructions

DPOM8-24/20 DIN RAIL POWER OVER MODBUS MODULE. Mounting and operating instructions

RXTH DUAL ROOM SENSOR / SWITCH

english S-5EC Potentiometer 5-step Operating Instructions Keep for reference! L-BAL-E265-GB 1608 Index 002

Installation manual for for Schleifenbauer DPM3

Fog machine PT Users Manual

Operating instructions. Switching amplifier DN0210 DN / / 2015

MDM 011-Z1 Regen Resistor

1 Channel Strobe Controller ORDERCODE 40226

PanelView Plus/VersaView CE Terminals and Display Modules

Blue Weapon Laser. User manual UK. Version 1.0

SolConeX extra-low voltage flange socket

LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E

Product manual plug, sockets and coupler 16 A.- Z0251

Symmetra PX 160. Maintenance Bypass Enclosure. Installation 05/

Operating instructions. Speed monitor D / / 2014

Digital Overhead Stirrer

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

JanusRAID SA-6692J Hardware User Manual

IGLOO IGLOO EASY INSTRUCTION MANUAL

Phase comparator. User manual Document version: 02i00 Update:

Quick Start Guide and Health and Safety Information

Chameleon Stand-alone

MAXIMA+ Series Rotary Level Indicator

Operation Manual Series W-500

Device technology. Supply Bus voltage V DC. Current consumption via bus. Accuracy in the range 300 1,000 ppm 1,000 2,000 ppm 2,000 5,000 ppm

IGLOO IGLOO EASY INSTRUCTION MANUAL

Operating Manual. icam100

Spectrum Laser. User manual UK. Version 1.0

Output Signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power Supply DC V, ±10%, 0.3 W

MAXIMA + Series ROTARY LEVEL CONTROL

Overview of types. Technical data

Room unit with PPS2 interface

Electromotoric actuators Torques up to 60 Nm Running times ¹) s. ¹) Predefined by the basic unit (LMV5...)

Crossfire. User Manual. Order code: EQLED061

B63/ NS MS. EtherNet/IP LINK

PTB 01 ATEX 2064 U, IECEx PTB U. Example / Beispiel / Exemple: Type Operating Instructions

LED PANEL. User Manual Please read the instructions carefully before use LED-7TC. Innovation, Quality, Performance 15-

Installation manual plugs and connectors with screw connection (16/32 A)

High Precision Quad Output DC Power Supply

InBin-P Pressure switches from 5 Pa Pa

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

Lynx Pro Audio S.L. Valencia, Spain

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern

MC 11 EB-2 Power supply cabinet with external bus, AC version

CPCI System Subrack 1 U

1. Safety Precautions

Promopar ORDERCODE 30120

Large Police Light 100W ORDERCODE 80361

Instruction Manual. T3110 T3110L T3110Ex

DMX LED Starcloth Systems

Configurable Network Paging Console. Product Instructions. Model: X-NPMI

SAMURAI SCAN 50 LED-SC50D. User Guide. Innovation, Quality, Performance. Professional Entertainment Technology 19-

Features: S98-B v1.0 S98-B 9-port switch with buffer power supply for 8 IP cameras

Vortex. User Manual. Order code: EQLED073

Conductive Level Controller

Electrical Actuators

LED W RGBA User Manual

RZ2 BioAmp Processor. Operator s Manual

RZ5/RZ5D/RZ6 Processor. Operator s Manual

CS2 DMX Distribution Splitter

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

Sapling Converter Box

SolConeX Wall-Mounted Socket, 16 A

InView Marquee Message Display

CMSA-100 Manual. Cinema Media Server Automation

Installation Instructions

Optional add-on cassette Attachment Instruction manual

USER MANUAL VIBRATION CONTROL RMA-POWER-BOX 107/230

Gobo Projector XP 80W

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

LEGA ENERGY ELECTRONIC RELAY VOLTAGE STABILIZER VA USER MANUAL

Output signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power supply DC V, ±10%, 0.3 W

LED Par 64 Short DMX ORDERCODE 42431

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

Cove Light AC HO RGB Graze INSTALLATION GUIDE V0.2. Cover: Cove Light AC HO-9 RGB Graze Cove Light AC HO-36 RGB Graze

Please read the instructions carefully before use LED PYRAMID LED-904D. Innovation, Quality, Performance 15-

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

VC3000 Series Line Voltage Switching Relay Pack Controllers Installation Guide

Blitzer Strobe. User Manual. Order code: EQLED366

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

ABB Drives. User s Manual I/O Module Adapter AIMA-01

Explosion proof UL certified VoIP telephone. FernTel IP Z2 UL. Tabletop unit. Manual FHF BA /12

CONTROL PANEL WIRING SPECIFICATIONS

Priva Blue ID Digital input module DI4/DI8/DI16

CPCI System Subrack 3 U

ZF LED Zoom Fresnel. User Manual

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

3/4 U CPCI Serial Case System

ELV12 Series. Instruction Manual

Flexoled FTP3HP RGB LED DMX Driver

Transcription:

STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER Mounting and operating instructions

Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 MOUNTING INSTRUCTIONS IN STEPS 5 VERIFICATION OF INSTALLATION 7 TRANSPORT AND STORAGE 8 WARRANTY AND RESTRICTIONS 8 MAINTENANCE 8 2-8

SAFETY AND PRECAUTIONS Read all the information, the datasheet, mounting and operating instructions and study the wiring and connection diagram before working with the product. For personal and equipment safety, and for optimum product performance, make sure you entirely understand the contents before installing, using, or maintaining this product. For safety and licensing (CE) reasons, unauthorised conversion and / or modifications of the product are inadmissible. The product should not be exposed to abnormal conditions, such as: extreme temperatures, direct sunlight or vibrations. Long-term exposure to chemical vapours in high concentration can affect the product performance. Make sure the work environment is as dry as possible; avoid condensation. All installations shall comply with local health and safety regulations and local electrical standards and approved codes. This product can only be installed by an engineer or a technician who has expert knowledge of the product and safety precautions. Avoid contacts with energised electrical parts. Always disconnect the power supply before connecting, servicing or repairing the product. Always verify that you apply appropriate power supply to the product and use appropriate wire size and characteristics. Make sure that all the screws and nuts are well tightened and fuses (if any) are fitted well. Recycling of equipment and packaging should be taken into consideration and these should be disposed of in accordance with local and national legislation / regulations. In case there are any questions that are not answered, please contact your technical support or consult a professional. 3-8

PRODUCT DESCRIPTION The STR-3 series of transformer fan speed controllers regulate the rotational speed of three-phase voltage controllable motors by varying the output voltage. They are equipped with auto-transformers and control the speed manually in five steps. The used technology provides a regulated output voltage with a perfect sinusoidal shape. ARTICLE CODES Article code Rated max. current [A] STR-3-35L10 3,5 STR-3-50L10 5,0 STR-3-75L10 7,5 STR-3100L10 10,0 STR-3130L10 13,0 INTENDED AREA OF USE Speed control of voltage controllable 230 VAC three phase motors For indoor use only TECHNICAL DATA STANDARDS Supply voltage: 230 VAC / 50 60 Hz Maximum motor current: depends on the version (see article codes) Unregulated output: 230 VAC Wide power range 5-step rotary switch for manual control plus off-position LED status indication Enclosure: sheet steel (RAL 7035, polyester powder coating) Protection standard: IP54 (according to EN 60529) Operating ambient conditions: Temperature: -20 35 C Rel. humidity: 5 95 % rh (non-condensing) Low Voltage Directive 2014/35/EC EMC Directive 2014/30/EC: EN 61326 WEEE Directive 2012/19/EC RoHs Directive 2011/65/EC 4-8

WIRING AND CONNECTIONS Connections Pe R S T N L1 U V W Earth terminals Power supply 3*230 VAC / 50 60 Hz Unregulated output, neutral Unregulated output, phase (230 VAC / 50 60 Hz) Regulated output to motor Make sure you use cables with an appropriate diameter. MOUNTING INSTRUCTIONS IN STEPS Before you start mounting the STR-3, read carefully Safety and Precautions and follow these steps. Choose a smooth solid surface for installation (a wall, panel, etc.). Follow these steps: 1. Open the door of the controller. Mind the wires that connect the rotary switch with the autotransformer. The mounting holes are on the inside back panel of the enclosure and are covered with blanking plugs. 2. Mount the enclosure using corrosion resistant screws or bolts. Mind the correct mounting position and unit mounting dimensions (see Fig. 1 Mounting dimensions and Fig. 2 Mounting position). 3. Pay attention to following instructions in order to minimize the operating temperature: 3.1 Respect the distances both between the wall / ceiling and the device and between two devices as shown in Fig. 2. In order to ensure sufficient ventilation of the controller, clearance on every side has to be maintained. 3.2 When installing the device, please keep in mind that the higher you install it, the warmer the device will get. For example, in a technical room the correct installation height can be of great importance. 3.3 If maximum ambient temperature cannot be adhered to, please provide extra forced ventilation / cooling. Not respecting the abovelisted rules can reduce service life and relieves the manufacturer of any responsibilities. 4. Once secured in position, the mounting screws or bolts should be sealed to maintain the IP rating of the enclosure. 5-8

1 3 2 4 STR-3 5. Because the controller enclosure is made of metal, it must be earthed and bonded to other existing metal surfaces. Fig. 1 Mounting dimensions Fig. 2 Mounting position Correct Incorrect A D B E 50 mm C 50 mm 50 mm Article code A B C D E STR-3-35L10 300 325 185 255 255 STR-3-50L10 300 325 185 255 255 STR-3-75L10 300 425 185 255 255 STR-3100L10 300 425 185 255 355 75 mm STR-3130L10 300 423 235 255 355 6. Insert the cables through the cable glands and do the wiring according to the wiring diagram (see Fig. 3) while adhering to the information from section Wiring and connections above. 6.1 Connect the power supply lines (terminals R, S, T and PE); 6.2 Connect the motor(s) (terminals U, V, W and PE) ; 6.3 If applicable, connect the unregulated output (L1 and N). It can be used to supply a 230 VAC valve, lamp, etc. when the knob is not at 0 position (see Table 1 below). A safety isolator/disconnect switch should be installed on the mains electricity side of all motor drives. The earth wire (green-yellow) of the electrical supply and of any equipment connected to the controller must be connected to the terminals marked as PE. Fig. 3 Wiring and connections STR-3-35L10, STR-3-50L10, STR-3-75L10 R S T N L1 U V W 3 x 230 VAC 230 VAC* STR-3100L10, STR-3130L10 Pe R S T Pe N L1 Pe U V W 3 x 230 VAC 230 VAC * * Do not connect N from the power supply network. 6-8

5. All works must be carried out with equipment fully isolated from the power supply. Make sure the connections are correct before you power the unit. 7. Close the cover. 8. Turn the knob at 0. 9. Tighten the cable glands. 10. Switch on the mains supply. 11. Make sure the tranformer controller can operates normally (consider an isolating switch). 12. Turn the knob into the relevant position to adjust the output voltage. Optional settings The standard configuration of the output voltages is as indicated in Table 1 below. Table 1 Voltage Knob position 0 1 2 3 4 5 Regulated output [VAC] 0 80 110 140 170 230 Unregulated output [VAC] 0 230 230 230 230 230 VERIFICATION OF INSTALLATION Use only tools and equipment with non-conducting handles when working on electrical devices. After connecting the unit to the mains supply, the green LED on its cover should light up indicating that the controller is supplied. Safe operation depends on proper installation. Before start up, ensure the following: The mains supply is connected correctly. Protection is provided against electrical shock. The cables are the appropriate size and fuse-protected. There is sufficient air flow around the unit. The unit is supplied with electrical energy at voltages high enough to inflict personal injury or threat to health. Take the relevant safety measures. Disconnect and confirm that there is no live current flowing to the unit before servicing. Avoid exposing the controller to direct sunlight! 7-8

TRANSPORT AND STORAGE Avoid shocks and extreme conditions; stock in original packing. WARRANTY AND RESTRICTIONS Two years from the delivery date against defects in manufacturing. Any modifications or alterations to the product after the date of publication relieve the manufacturer of any responsibilities. The manufacturer bears no responsibility for any misprints or mistakes in this data. MAINTENANCE In normal conditions this product is maintenance-free. If soiled, clean with a dry or damp cloth. In case of heavy pollution, clean with a non aggressive product. In these circumstances the unit should be disconnected from the supply. Pay attention that no fluids enter the unit. Only reconnect it to the supply when it is completely dry. 8-8