MTL8000-2/x Series Modular I/O

Similar documents
GE Intelligent Platforms PAC8000 RTU

TURCK Process Automation IS Interface Technology. Interface Modules. IM Series Cabinet

APPLICATION GUIDE. Interface Modules IM Series.

PAC8000 Hybrid controller (8521-

Control IT S800 I/O System

M-series Intrinsically Safe I/O

WAGO-I/O-SYSTEM. Fieldbus Technology. for Use in Hazardous Areas

Intrinsic Safety Control Drawing

Operating Instructions

Zener Barriers Bulletin 937Z

INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS

General. Remote I/O A4/1.

Engineering Guideline. pac-carriers Type for Honeywell system Experion Series C I/O

S900 Remote I/O System Intrinsic safety in the field ABB

Innovation for system integration

Intrinsically Safe Barriers

Wieland Hazardous Location Devices. Protect Your Class I, Division 2/Zone 2 Locations...And Your Budget

Trusted Strategic Partners in Process Automation. Alliance Member

PROCESS AUTOMATION. MANUAL Z-System. Zener Barriers ISO9001

S800 I/O ABB Automation

Hazardous Area Protection

X57. Intrinsic Safety Barriers

F101, F102, F104. Relcom Installation Instructions. Fieldbus Power Supply F101-PS

PAC BI-DP BIM and 8701-CA-BI Carrier

PAC8000 I/O - 2/2 I/O Modules General-purpose and 2/2 Applications with SafetyNet

PROFIBUS and Integrated Safety architectures in Ex areas

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

How to calculate an Intrinsically Safe loop approval.

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

products PC Control

Your Global Automation Partner. excom I/O System

LB Remote I/O. CEAG Sicherheitstechnik GmbH 256

Isolating repeater IRU 420

Safety Barriers. CEAG safety barriers can be used for all kinds of instrumentation applications.

MARINE CERTIFIED PRODUCTS BY PEPPERL+FUCHS

Termination Board FC-GPCS-RIO16-PF. Features. Assembly. Function. Connection USIO/UPIO 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

5 Fieldbus Technology

High Availability Fieldbus Networks New Physical Layer Technologies. : Nagesha Nayak : Manager Project Pursuit

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

LION SAFE Remote I/O System. LÜTZE TRANSPORTATION GMBH Dimitrios Koutrouvis V00

INTRINSICALLY SAFE ACOUSTIC EMISSION TRANSDUCERS

About the FLEX Ex I/O Systems

expertise I reliability I professionalism

SYSTEM COMPONENTS SYSTEM COMPONENTS MODULES

IECEx Certificate of Conformity

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

How Emerson s I/O on Demand Is Changing the Automation Infrastructure

M-series DeltaV Controller Interface for PROVOX I/O

Product Design Assessment (PDA) Certificate for Component Details

Safety instructions Overvoltage protection B81-35

PRM Integration Guide with. MTL 4840 Series HART Multiplexer

S-Series DeltaV Controller Interface for PROVOX I/O

FOUNDATION Fieldbus Fieldbus Basics

remote I/O future inside

INSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069

POINT I/O Family. Chapter. Overview

String monitoring with CMS - Circuit monitoring system Increased productivity and improved maintenance of PV systems

ELECTRONIC AND CONTROL PROCESS DEVICES. reliability. professionalism. Company Profile.

Advances in NeSSI TM communications

CPU module for zone 2 Series 9442/35

Distributed Intrinsically Safe Fieldbus Applications

D1093S INSTRUCTION MANUAL. D SIL 3 Relay Output Module with Line and Load diagnostics. DIN-Rail Model D1093S

Backplane. Allen-Bradley. System integration. Backplane

New FOUNDATION Fieldbus Interface Techniques Increased Availability and Reduced Costs. Andreas Agostin Pepperl+Fuchs

SIGUARD Safety Combinations and Safe Load Feeders. safety INTEGRATED

FOUNDATION Fieldbus Fieldbus Basics & its Benefits

PHOENIX CONTACT - 05/2007

10 Mb/s Single Twisted Pair Ethernet Process Industry Requirements Steffen Graber Pepperl+Fuchs

Compact Control Builder AC 800M and S800 I/O ABB

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

Instrumentation for Process Analytics

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

Solutions for Fossil Fuel Energy

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

Having communication issues? Model 6 intelligent Motor Control Centers communicate on all platforms. Make the most of your energy SM

M-series DC to DC Power Supply

POINT I/O Family. Chapter. Overview

FOUNDATION. Product Overview. Foundation Fieldbus

M-series Profibus DP Series 2 Plus Interface Card

MSI 100, MSI 200 Programmable Safety Controllers

Safety instructions. IECEx TUN Ex ia IIC T6 Gb

MTL830 SERIES. Cuts installation and cable costs for all IS hazardous-area circuits

West Instruments. The MLC compact multi-loop controller... MLC ends the control or integration compromise

TFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5

General Specifications

GE Intelligent Platforms. Wellhead RTU Solutions

POINT I/O Family. Chapter. Overview

SIRIUS Motor Management and Control Devices

Embedded systems extend automation

IS1 remote I/O. ready for the future

FLEX Ex Spring Clamp Terminal Base

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

Practical Programmable Logic Controllers (PLCs) for Automation and Process Control. Contents

Cube20. Application-oriented. Installation-friendly. Efficient

BA448CF-F FOUNDATION fieldbus Intrinsically safe Panel mounting 8 variable Fieldbus Indicator Issue 3

SOLUTIONS FOR THE PHARMACEUTICAL INDUSTRY Solutions for the Pharmaceutical Industry

SIL certified safety for people, the environment and machinery Overview of PROGNOST -SILver safety analyses... 6

Automation systems. Scalable performance for every requirement

M-series Foundation Fieldbus I/O

Transcription:

-2/x Series Modular Overview Modules Modules - Overview - 2/2 components Use this option for general purpose or nonhazardous applications, or where the equipment and/or field wiring has to be mounted in Zone 2 or Division 2 hazardous areas. Select modules and their field terminals followed by module carriers, Bus interface modules and supply options. 2/2 Modules Analog Input Analog Output Discrete Input Discrete Output Pulse Input 2/1 Modules Analog Input Analog Output Discrete Input Discrete Output Pulse Input Field Terminals 2/2 and 2/1 Terminals s, Extenders, Cables 2/2 s 2/2 Extenders 2/2 Cables - 2/1 components Use this option for Zone 2 or Division 2 hazardous area mounting where the field wiring must connect into Zone 1, Zone 0 or Division 1 hazardous areas. The modules have intrinsic safety (IS) interfaces built in. Select modules and their appropriate IS field terminals followed by module carriers, Bus interface modules and supply options. 2/1 s 2/1 Extenders 2/1 Cables Power Supplies DC/DC Power supplies - 2/2 and 2/1 AC/DC Power supplies - 2/2 Bus Interface Modules Modbus and Profibus - DP Configurator software Node Services Module HART interface module System Specification System specification Cable parameters and approvals Thermocouple characterisation 1

General is a completely modular solution for both general purpose and hazardous area applications. Based upon a carrier system that supports a range of modules, it offers a wide variety of functions, including AC mains and intrinsic safety signals - even within the same node. It has an open architecture that allows communication with a variety of different field-buses by selecting the appropriate type of Bus Interface Module (BIM). 5 Modules 1 4 modules transfer signals to and from field instruments. Input modules receive signals from transmitters and sensors and convert them into a digital form for presentation to the BIM. Output modules receive commands from the BIM and transfer them to actuators. A wide range of modules is available, including types for low-level instrumentation, AC mains and intrinsically safe signals. modules typically have 4, 8 or 16 field channels. Field terminals 2 Field terminals provide the interface between the modules and the field wiring. They include fusing and loopdisconnect as options. A mechanical keying system prevents an module from being connected to the wrong type of field terminal. Field terminals mount onto the module carrier, one to each module. They are clamped firmly by the module to form an electrical and mechanical assembly of high integrity. They may be replaced in service without removing carriers or disturbing the operation of other modules. s 3 s form 's physical and electrical backbone by providing a mounting onto a flat panel or T- or G-section DIN rail. They support and interconnect the BIM, supplies, modules and field terminals, and carry the address, data and lines of the internal Railbus. They provide a termination points for the LAN and field wiring cable screens and can also distribute bussed field to the modules. module carriers are available to support four or eight modules. Power supplies 4 Good management lies at the heart of a true distributed- system. supplies accept locally available unregulated and provide a regulated supply for the BIM and modules. Supply redundancy is supported. 3 2 1 Bus Interface Module (BIM) 5 The BIM provides a serial data connection to a host controller, which could be a distributed control system (DCS), a programmable logic controller (PLC), or a PC running a soft control package. A choice of BIMs allows you to accommodate the most popular fieldbus protocols. The BIM also uses a fast internal bus to pass data to, and obtain data from, the modules. Only one BIM is required at each node to control up to 32 modules. HART-ability The use of smart instruments on process plants is growing but this investment is not always fully exploited. Whether it is for a new installation, or the upgrade of an existing one, MTL has solutions that provide the connections between the HART field instruments, the control systems and the process automation maintenance software. Specifically, the Process system has been designed to be transparent to HART signals, thus allowing the host control software and any HART field instruments to communicate directly with each other. In addition, MTL s HART connection system provides on-line access from a PC to the HART field devices for monitoring device performance. HART devices may be selected for regular status monitoring and alerts can be issued if the status changes. The benefits from this approach are: Reduced commissioning time and cost Reduced process downtime through status monitoring Lower loop maintenance costs by using field device diagnostics Consult an MTL representative for further details. System specification See end of section. 2

in your system Figure 1 shows two possible methods for linking the into a system. On the left is a host controller system that uses fieldbus as the main distribution medium. On the right is a section of a typical DCS/PLC information network, with an operator station that uses a separate interface to the process fieldbus. Host controller Standard fieldbus controller interface DCS / PLC The number of nodes that can be accommodated depends upon the addressing capability of the fieldbus in use. Each node can address 32 modules which, depending upon the number of channels per module, can provide up to 512 points at a single node! A node can consist of a mixture of analog and discrete modules and this gives maximum flexibility to the system designer. Where supported by the fieldbus, full HART pass-through is provided the appears transparent, allowing the host controller to access the HART capabilities of field instruments. Figure 1 - in a system Process LAN/fieldbus Process LAN /fieldbus Fieldbus compatible device node Wide choice of fieldbus options supports a number of popular fieldbus protocols: Modbus (RTU mode), Profibus DP, etc., and the range is growing. If your protocol is not mentioned then consult us. MTL is also interested in talking to OEM partners who want to develop their own fieldbus variations. A software core has been developed that simplifies the design of alternative control interfaces for the system. Redundancy options has been designed to increase availability and minimise downtime. Redundant LAN channels and supplies can be specified as options to increase system availability. Possible downtime is further reduced by ensuring that the system components using active circuitry can be removed and replaced quickly and easily. Even the field terminals can be replaced without interrupting the operation of adjacent modules. s have no active circuitry and are unlikely to need replacement. System supplies The system supply at an node converts the local DC supply to the node and can also provide field for modules with low-level field circuits. Where heavy-current or AC mains circuits are handled by the modules, MTL s innovative scheme for distributing field avoids complex wiring at the field terminal and minimises the backplane/carrier wiring. a) b) c) Zone 0 Hazardous area applications Division 1 Division 2 Zone 1 Figure 2 - in hazardous areas The is a truly field mountable system even in areas where flammable gases are present. It is available in three versions to suit different area classification schemes: a) Equipment and field wiring located in general purpose areas, Class 1, Division 2 hazardous locations or Zone 2 hazardous areas. b) Equipment mounted in general purpose areas, Class 1, Division 2 hazardous Zone 2 (and general purpose) locations or Zone 2 hazardous areas, with field wiring located in Division 1 hazardous locations or Zone 0 hazardous areas. c) -1/1 equipment mounted in Zone 1 hazardous areas, with field wiring located in Zone 0 or Zone 1 hazardous areas. Figure 2 illustrates the connection of field devices for these various options. 3

with general purpose field wiring Many industry applications do not present an explosion risk from gas or dust hazards. In others, the environment may be classified as a Zone 2 or Division 2 hazardous area, where flammable material is expected to occur only in abnormal conditions. For both of these the 2/2 system provides effective distributed for process control. supports a full range of module types covering inputs and outputs for both analog and discrete circuits. The node can be mounted out on the plant in a suitable enclosure providing protection against the environment. Figure 3 shows a node containing all the key components: a Bus Interface Module, PSU modules (including a redundant one), modules on carriers and a pair of carrier-s linked with an extension cable. local 18 36 V DC System supply Otional redundant system supply module (LH) Bus Interface Module (RH) To maximum of 32 modules D.C. link to other with intrinsic safety field wiring The Process System is capable of supporting modules with intrinsic safety (IS) field wiring, for connection to certified or simple apparatus field devices in Division 1 or Zone 0 hazardous areas (see Figure 4). A range of module types with IS field circuits for industrystandard DI, DO, AI and AO applications is supported. modules with built-in protection All voltage and current-limiting components required for IS protection are incorporated within the module housings, so no external, add-on zener barriers or galvanic isolators are necessary. IS field terminals are distinguished from other types by blue colouring of the terminal housing. A unique and sophisticated mechanical keying mechanism prevents modules with different protection techniques from being interchanged, so that potentially explosive or damaging conditions cannot occur. Integrated supplies Power for IS modules is derived from integrated, modular supply units. Each unit is capable of supplying between eight and twenty modules, depending on the type and mix. Optional supply redundancy is supported by means of an additional, redundant supply unit connected in an n+1 arrangement. In applications with mixed IS and non-is field wiring, the full facilities of the regime are retained for the non-is part of the system. Figure 3 node 12 V dc BIM (LH) Bus Interface Module LAN terminals Module and module supply module supply Figure 4 node with IS field wiring In nodes populated only with IS modules, a separate system supply module provides for the Bus Interface Module and node services. Redundancy of this supply is also supported. Extender (RH) DIN rail Extender cables To maximum of 32 modules Optional n+1 redundant module suppl y 4

Mixed types within a single node IS and non-is field wiring types can also be incorporated within one node (see Figure 5). In this arrangement, the two parts of the node are separated by a module. The Railbus Isolator provides a section of internal communications bus ( Railbus ) for the IS modules which is protected from invasion by damaging fault voltages Uniquely, a single node (under the command of one Bus Interface Module) can then support a mixture of certified IS field devices, certified Division 2 or Zone 2 field devices and general purpose, including AC mains circuits. Only one is used per node. Node services carrier (Safe area or Zone 2/Div 2 field wiring) 18 36V dc r (Safe area or Zone 2/Div 2 field wiring) module and carrier Related Literature AN8000 System Specifier s Guide - Modular INM8000 Installation Guide module Figure 5 node with mixed IS and non IS field wiring Optional n+1 redundant module supply 5