Option X4 Additional Operator Panel AOP-2 Description of option Functional description

Similar documents
Getting started - USW 3.x Software download from internet Software installation Device setup Data backup

Option P1 Event and alarm printer Description of option Functional description Parameter list

Compact Genset Controller, CGC 400 What's in the delivery? The first steps Push-buttons and LEDs

QUICK START GUIDE Generator Paralleling Controller, GPC-3 Generator Protection Unit, GPU-3/GPU-3 Hydro Paralleling and Protection Unit, PPU-3

Automatic Genset Controller, AGC-4 What s in the delivery? Getting started The first steps Using the AGC

AGC 200 Advanced Gen-set Controller What s in the delivery? Getting started The first steps Using the AGC 200

EAP 300 REMOTE ANNUNCIATOR INSTALLATION MANUAL. r.0454a

Option H8.x and H12.x External I/O modules Description of option Functional description

Automatic Genset Controller, AGC-3 What's in the delivery Getting started The first steps Using the AGC

Automatic Genset Controller, AGC-4 What s in the delivery? Getting started The first steps Using the AGC

DEIF A/S. Description of options. Option C2, Generator add-on protection package Automatic Gen-set Controller. Description of option

DEIF A/S. Description of options. Option P1, Event and alarm printer Automatic Gen-set Controller. Description of option. Functional description

APPLICATION NOTES H-coupling

Option H10, Multi-line 2 unit with USB service port. To be used when the multi-line 2 unit service port is USB type

Inverter Interface Interface examples Wiring examples Communication topology

DEIF A/S. Description of options. Option C1 Generator add-on protection package Multi-line 2 version 2. Description of options. Functional description

MULTI-LINE 2 DESCRIPTION OF OPTIONS

OPERATOR'S MANUAL Generator Paralleling Controller, GPC-3 - Generator Protection Unit, GPU-3/GPU-3 Hydro - Paralleling and Protection Unit, PPU-3

APPLICATION NOTES Translations

MULTI-LINE 2 APPLICATION NOTES. Converting PPU-2 to PPU-3 Parameter conversion Wiring Options I/O list. Document no.: A SW version:

MULTI-LINE 2 APPLICATION NOTES

DEIF A/S. Description of options. Option A and B, Loss of mains protection package Automatic Gen-set controller. Description of options

Advanced Graphical Interface, AGI 100

CODESYS v. 2.3, Ethernet driver for AGI 3xx Use the CODESYS Ethernet driver in the AGI Creator Set up the CODESYS for use with the AGI Creator

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

QUICK START GUIDE Generator Protection Unit GPU 300

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

QUICK START GUIDE Paralleling and Protection Unit PPU 300

Panorama rudder indicator TRI-2 Analogue or CAN input Approved according to MED Three extra large scales Long-life LED illumination Built-in dimmer

QUICK START GUIDE Paralleling and Protection Unit PPU 300

DEIF A/S. Description of options. Option H4 Serial comm. CAT CCM communication Multi-line 2 version 2. Description of option Functional description

Genset control and protection with safety system

APPLICATION NOTES DELOMATIC 4, DM-4 GAS/HYDRO

Option M2 Configurable engine control cards Multi-line 2 version B SW version 2.4X.X

Engine Control Unit, ECU 100 Engine control Engine monitoring and protection Easy-to-read graphical display Integrated emulation software solution

Option H3 Serial communication Profibus DP

RTC 300/RTC 600 Installation instructions scan

DATA SHEET IOM 200 analogue interface for AGC 200

Engine Control Unit, ECU 100 Engine control Engine monitoring and protection Easy-to-read graphical display Integrated emulation software solution

Genset Controller Unit Model EMS - GC10. Installation Manual Section

MULTI-LINE 2 APPLICATION NOTES. Converting PPM-2 to PPM-3 Parameter conversion Wiring Options I/O list Modbus. Document no.: A SW version:

Compact Genset Controller, CGC 200 Mounting Terminals and wiring Commissioning, using the Utility Software and/or the front panel

APPLICATION NOTES. Advanced Graphical Interface - AGI Internal PLC (CODESYS V3) SHENDONG

MULTI-LINE 2 DESCRIPTION OF OPTIONS. Option N Modbus TCP/IP SMS/ alarms NTP time synchronisation. Document no.: D SW version:

APPLICATION NOTES. HEADING INDICATOR SYSTEMS using XDi-N indicators. Document no.: A

Automatic Sustainable Controller, ASC Mounting Board slot positions Terminal strip overview I/O lists Wiring

Installation Manual. Multi Power Controller MPC-1 multi-line D

DATA SHEET Rudder/azimuth angle Transmitter CAN, RTC 300/RTC 600

MULTI-LINE 2 DESCRIPTION OF OPTIONS. Option N Modbus TCP/IP SMS/ alarms NTP time synchronisation. Document no.: C SW version:

Insight Installation of FX30 Data Acquisition Unit (DAU) Login to Insight Setup Insight with your equipment in the cloud Related system information

Compact Genset Controller, CGC 400 Generator control and protection Engine monitoring and protection Generator and mains breaker control RS485 Modbus

PumpDrive DPM. Installation and Operating Instructions Dual Pump Module (DPM) /4--10

Connection and configuration of a CDP with KACO NEW ENERGY inverters

INSTALLATION INSTRUCTIONS

DATA SHEET Advanced Graphical Interface, AGI 100 series

Wiring Guide. EP.NMiNi 2. Version 1.04 Last Updated:

Basic Gen-set Controller G (UK) SW version 2.1X.X. Terminal strip overview

MIC-2 MKII Profibus module user s manual

Description of options. user s manual. DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: Fax:

crio PN Installation Instructions V0.2/ COMSOFT

DATA SHEET Selectable AC transducer, TAS-331DG

Connecting a Cisco Reader Module

Keypad CT2000. Art. No.: , (black) Art. No.: , (white) Installation Manual

8000 Series: Installation Supplement R2-1-12

Conect 121 Upgrade. Copyright 2013 Conqueror Design and Engineering Ltd.

Input Power Selector Switch. Product Manual (Revision NEW) Original Instructions for use with Generator Set Control Assembly

DATA SHEET Compact Genset Controller, CGC 200

for Energy and Power meters AEM and APM with Modbus interface

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

HI SEC Integrated Systems

Engine & Genset Controls Z, page 1 of 12

Model: EP.L3800. Wiring Guide EP.L3800. Version 1.03 Last Updated:

SAFETY PRECAUTIONS CAUTION WARNING CAUTION. Thank you for purchasing ig5a Series Profibus Communication Module

Advanced Graphical Interface, AGI 3xxG General information Product information Technical information Connections and ports

MicroTech III Applied Terminal Systems BACnet MS/TP Communication Module

Part No. Z , IA Nov OPERATION MANUAL. High Voltage Digitalmeter A

CRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09

General Information 1. Connection 2. User Interface 3 ATC5300. Menus 4. Automatic Transfer Controller. Remote Control Software Manual A5E

PS/IO Circuit Board Retrofit

Operating instructions IO-Link master CabinetLine AL19xx

DORMA. Installation Manual Extension kit I/O module in the B6L 4P

DATA SHEET Selectable AC transducer, TAS-321 DG

Connecting a Cisco Output Module

EV Evaluation System User Guide. Contents. Kit Contents. Introduction

SK CU4-PBR-C Part number:

Single Door Standalone Access Control User Manual

Wiring Instructions for Replacement of 2301A Load Sharing and Speed Controls with 2301D Load Sharing and Speed Controls

MIC-2 MKII I/O module user s manual

DF PROFI II PCIe. Installation Instructions V Project No.: 5302 Doc-ID.: DF PROFI II PCIe KUNBUS

DF PROFI II CPCI. Installation Instructions V Project No.: 5302 Doc-ID.: DF PROFI II CPCI KUNBUS

DATA SHEET Advanced Graphical Interface, AGI 300 series

Installing Sentor. Hardware Installation

DI 8x24VDC ST digital input module SIMATIC. ET 200SP DI 8x24VDC ST digital input module (6ES7131-6BF00-0BA0) Preface. Documentation guide

Serial Data DIN Fiber Link System

DATA SHEET Advanced Graphical Interface, AGI 100 series

1395 Node Adapter Board Troubleshooting

HI-POT TESTER User Manual

CEM M-RS485 INSTRUCTION MANUAL (M014B A)

High Pressure E/P Regulator. ITVH Series

Connection and configuration of a CDP with Fronius MB inverters

Transcription:

MULTI-LINE 2 DESCRIPTION OF OPTIONS Option X4 Additional Operator Panel AOP-2 Description of option Functional description DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax: +45 9614 9615 info@deif.com www.deif.com Document no.: 4189340484I SW version:

1. Delimitation 1.1. Scope of Option X4... 3 2. General information 2.1. Warnings, legal information and responsibility... 4 2.1.1. Warnings and notes...4 2.1.2. Legal information and disclaimer...4 2.1.3. Safety issues... 4 2.1.4. Electrostatic discharge awareness... 4 2.1.5. Factory settings... 5 3. Description of option 3.1. Option X4 AGC 200...6 3.1.1. About the option - for AGC 200... 6 3.2. Option X4 AGC 100, ECU 100, GCU 100, GC-1F/2... 6 3.2.1. About the option - for AGC 100, ECU 100, GCU 100, GC-1F/2...6 3.3. Rear side view, connectors, wiring...6 3.3.1. Rear side view... 6 3.3.2. Connectors... 7 4. Functional description 4.1. Principle diagram...8 4.1.1. Connection...8 4.2. AOP-2...8 4.2.1. Front side view...8 4.2.2. Wiring - cable type 1...9 4.2.3. Wiring - cable type 2...10 4.2.4. CAN Node ID configuration...11 4.2.5. Selection of CAN ID...11 4.2.6. Status relay...11 4.2.7. Programming... 11 5. Error handling 5.1. Duplicate CAN ID... 12 5.1.1. AOP-2...12 DEIF A/S Page 2 of 12

Delimitation 1. Delimitation 1.1 Scope of Option X4 This description of options covers the following products: AGC 100 series AGC 200 series APU 200 series GC-1F/2 ECU/GCU 100 series SW version 4.0x.x or later SW version 3.5x.x or later SW version 3.53.x or later SW version 1.2x.x and 2.0x.x or later SW version 1.0x.x or later DEIF A/S Page 3 of 12

General information 2. General information 2.1 Warnings, legal information and responsibility 2.1.1 Warnings and notes Throughout this document, a number of warnings and notes with helpful user information will be presented. To ensure that these are noticed, they will be highlighted as follows in order to separate them from the general text. Warnings Notes Warnings indicate a potentially dangerous situation, which could result in death, personal injury or damaged equipment, if certain guidelines are not followed. Notes provide general information, which will be helpful for the reader to bear in mind. 2.1.2 Legal information and disclaimer DEIF takes no responsibility for installation or operation of the generator set. If there is any doubt about how to install or operate the engine/generator controlled by the Multi-line 2 unit, the company responsible for the installation or the operation of the set must be contacted. The Multi-line 2 unit is not to be opened by unauthorised personnel. If opened anyway, the warranty will be lost. Disclaimer DEIF A/S reserves the right to change any of the contents of this document without prior notice. The English version of this document always contains the most recent and up-to-date information about the product. DEIF does not take responsibility for the accuracy of translations, and translations might not be updated at the same time as the English document. If there is a discrepancy, the English version prevails. 2.1.3 Safety issues Installing and operating the Multi-line 2 unit may imply work with dangerous currents and voltages. Therefore, the installation should only be carried out by authorised personnel who understand the risks involved in working with live electrical equipment. Be aware of the hazardous live currents and voltages. Do not touch any AC measurement inputs as this could lead to injury or death. 2.1.4 Electrostatic discharge awareness Sufficient care must be taken to protect the terminal against static discharges during the installation. Once the unit is installed and connected, these precautions are no longer necessary. DEIF A/S Page 4 of 12

General information 2.1.5 Factory settings The Multi-line 2 unit is delivered from factory with certain factory settings. These are based on average values and are not necessarily the correct settings for matching the engine/generator set in question. Precautions must be taken to check the settings before running the engine/generator set. DEIF A/S Page 5 of 12

Description of option 3. Description of option 3.1 Option X4 AGC 200 3.1.1 About the option - for AGC 200 This option includes an additional operator panel (AOP-2) which can be connected to the AGC 200 via a CAN bus communication port. The AOP-2 has 16 configurable LEDs and eight configurable buttons, which are programmed with the PC utility software. It can be used as an interface to the AGC 200 unit for indication of status and alarms together with buttons for, for example, alarm acknowledge and mode selection. A maximum of five AOP-2 units can be connected to each AGC 200 unit. 3.2 Option X4 AGC 100, ECU 100, GCU 100, GC-1F/2 3.2.1 About the option - for AGC 100, ECU 100, GCU 100, GC-1F/2 This option includes an additional operator panel (AOP-2) which can be connected to the GC-1F via the CAN bus 2 communication port and via CAN bus B on AGC 100, ECU 100 and GCU 100. The AOP-2 has 16 configurable LEDs and eight configurable buttons, which are programmed with the PC utility software. It can be used as an interface to the unit for indication of status and alarms together with buttons for, for example, alarm acknowledge and mode selection. A maximum of two AOP-2 units can be connected to each GC-1F unit, and five AOP-2 units to each AGC 100, ECU 100 and GCU 100. 3.3 Rear side view, connectors, wiring 3.3.1 Rear side view Additional operator panel AOP-2 End resistor 2 1 OFF ON CAN 1 CAN 2 DEIF A/S Page 6 of 12

Description of option 3.3.2 Connectors CAN 1: DC supply and CAN bus communication to/from the controller. CAN 2: CAN bus communication to/from the controller or additional AOP-2 units and status relay output. End resistor 1 AOP-2 unit connected: Dip switch no. 1 on the unit should be set to ON. 2 AOP-2 units connected: Dip switch no. 1 on AOP-2 no. 1 should be set to OFF. Dip switch no. 1 on AOP-2 no. 2 should be set to ON. on AOP-2 no. 2 should be set to ON. DEIF A/S Page 7 of 12

Functional description 4. Functional description 4.1 Principle diagram 4.1.1 Connection Below is a principle diagram of the connection of the additional displays and operator panels. AGC 100/AGC 200/GC-1F CANbus comm. DC power supply DC power supply AOP-2 CANbus comm. AOP-2 4.2 AOP-2 4.2.1 Front side view As shown on the drawing, the configurable LEDs are named 1 to 16, and the buttons are named 1 to 8. DEIF A/S Page 8 of 12

Cable shield Twisted pair NC Com NO Red/white Brown/white Red Brown Black/white Black Red/white Brown/white Red Brown Black/white Black Option X4 additional Operator Panel AOP-2 Functional description 4.2.2 Wiring - cable type 1 Be aware that two cables can be chosen, and that there is a difference in the colour codes of the wires. The diagrams below show how to wire up both cable types. OFF ON 2 1 CAN 1 CAN 2 6 5 4 3 2 1 6 5 4 3 2 1 Comm. to other units Status relay Gnd End resistor 120 CAN H CAN L 5V DC 24V DC + - Output Input + - Power supply Terminals for CAN connection CAN L CAN H AGC 200/APU 200 CAN A 9 7 CAN B 12 10 CAN C 15 13 AGC 100/ECU 100/GCU 100 CAN B 59 57 GC-1F/2 CAN 2 59 57 DEIF A/S Page 9 of 12

Cable shield Twisted pair NC Com NO Blue Yellow Green Red Black White Blue Yellow Green Red Black White Option X4 additional Operator Panel AOP-2 Functional description 4.2.3 Wiring - cable type 2 OFF ON 2 1 CAN 1 CAN 2 6 5 4 3 2 1 6 5 4 3 2 1 Comm. to other units Status relay Gnd End resistor 120 CAN H CAN L 5V DC 24V DC + - Output Input + - Power supply Terminals for CAN connections CAN L CAN H AGC 200/APU 200 CAN A 9 7 CAN B 12 10 CAN C 15 13 AGC 100/ECU 100/GCU 100 CAN B 59 57 GC-1F/2 CAN 2 59 57 It is recommended to keep a fair distance to power cables. DEIF A/S Page 10 of 12

Functional description The maximum length of the CAN bus line is 200 m. A DC/DC converter for the DC supply voltage and 2 1 m cable with an RJ12 plug in one end and stripped wires in the other end are included in the AOP-2 delivery. 4.2.4 CAN Node ID configuration The CAN Node ID for the AOP-2 can be set to 1-9, it is done by following this procedure: 1. Press buttons no. 7 and no. 8 at the same time to activate the CAN ID change menu, this will activate the LED for the present CAN ID number, and LED no. 16 will be flashing. 2. Use button no. 7 (increase) and button no. 8 (decrease) to change the CAN ID according to the table below. 3. Press button no. 6 to save the CAN ID and return to normal operation. 4.2.5 Selection of CAN ID CAN ID Indication of CAN ID selection 0 CAN bus OFF: LED 16 flashes 1 LED 1 light steady + LED 16 flashes (default value) 2 LED 2 light steady + LED 16 flashes 3 LED 3 light steady + LED 16 flashes 4 LED 4 light steady + LED 16 flashes 5 LED 5 light steady + LED 16 flashes Node ID 1-9 for AOP-2s and Node ID 10-64 for external I/O modules (option H8). 4.2.6 Status relay The status relay is used for watchdog function. It will activate approximately two seconds after power up if the CAN bus communication is OK and no internal failures are present. 4.2.7 Programming The programming of the AOP-2 is made with the PC utility software, which can be downloaded from www.deif.com. Refer to the Help function in the PC utility software for instructions regarding the programming. DEIF A/S Page 11 of 12

Error handling 5. Error handling 5.1 Duplicate CAN ID 5.1.1 AOP-2 If two units on the CAN bus have the same CAN ID, LED no. 1 to 4 will flash quickly. In this case, press button no. 6 to jump into the CAN ID change menu and select another CAN ID for the unit. DEIF A/S Page 12 of 12