ISOMETER isoev425 with coupling device AGH420

Similar documents
ISOMETER isoev425/isoev425hc with coupling device AGH420

ISOMETER isopv with coupling device AGH-PV

preliminary ISOMETER isoev425 with coupling device AGH420 Preliminary datasheet

ISOMETER iso685-d-b. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Preliminary data sheet

LINETRAXX RCMS150. Residual current monitor type B with integrated measuring current transformers for earthed AC/DC systems (TN and TT systems)

T M. IRDH375 Series. Digital Ground Fault Monitor / Ground Detector For Ungrounded (Floating) AC/DC Systems. Technical Bulletin NAE / 09.

COMTRAXX COM465IP. Condition Monitor with integrated gateway for the connection of Bender devices to Ethernet TCP/IP networks

COMTRAXX COM465IP. Condition Monitor with integrated gateway for the connection of Bender devices to Ethernet TCP/IP networks

COMTRAXX COM465DP. Condition Monitor with integrated gateway for the connection of Bender devices to PROFIBUS DP and Ethernet TCP/IP networks

COMTRAXX COM460IP. BMS-Ethernet-Gateway

COMTRAXX COM465IP. Condition Monitor with integrated gateway for the connection of Bender devices to Ethernet TCP/IP networks

VMD420-DM Voltage and frequency monitor

BMS-Ethernet-Gateway COM460IP

RCMB20/RCMB Series

CC612 EV charge controller

RCM420-DM. Residual current monitor for AC current monitoring in TN and TT systems with an analogue interface Software version: D240 v1.2x.

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

Datasheet - SRB 402EM-24V

Electronic monitoring relays PMDsrange

02/11/2015

RCMA420-DM Residual current monitor

Electronic timer CT-EAS ON-delayed and OFF-delayed with 1 c/o contact Data sheet

VEO. V2ZS V AC/DC Art.Nr.: V2ZS20P V AC/DC Art.Nr.: TECHNICAL DATA

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

Datasheet - SLB 200-C04-1R

Contact protection relay

Safety Switching Devices SNO 4003K. Basic device for Emergency-Stop and Safety Gate Applications PI E

Switching relay CT-IRS with 1, 2 or 3 c/o contacts Data sheet

Control elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.

Zelio Control-modular measurement and control relays 1

PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B

Datasheet - SRB 301LC/B-24V

E-STOP relays, safety gate monitors

24 V DC typ. 0,65 W. Liquid level with conductive probes (type SK1, SK5) Resistance measurement E1-E0, E2-E0, E3-E0, E4-E0

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

Datasheet SRB301ST 24V (V.2)

Positive-guided relay outputs: 4 safety contacts (N/O), instantaneous

Electronic timer CT-AHS OFF-delayed with 2 c/o contacts Data sheet

VEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA

Power Supply HARTING pcon

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

ISOMETER isolr275 Coupling device AGH-LR

AS-i Safety Relay Output Module with Diagnostic Slave, 1 EDM, 1 x 2 channel Safe Input

Power supply CP-C 24/5.0

RM35TF. Main. Product or component type. Product specific application. Relay monitored parameters 250 V AC 5 A AC

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

E-STOP relays, safety gate monitors

MIC-2 MKII, Multi-instrument DATA SHEET

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B

RM35TF V AC

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

EMD-FL-C-10. Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks

PHOENIX CONTACT Features

PNOZ s1. Safety relays. Operating Manual EN-07

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

Messaging module CP-C MM

Voltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages

Nemo SX - Multifunction control module

PHOENIX CONTACT - 07/2006

E-STOP relays, safety gate monitors

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Process displays For current and voltage

RTU500 series Data Sheet Power Supply CP-E 24/2.5

Zelio Control - modular measurement and control relays 1 Speed control relays RM35 S

PGR-6100 MANUAL GROUND-FAULT & INSULATION MONITOR

Electronic timer CT-ERS.21

Safe timer relay/contact expansion modules

E-STOP relays, safety gate monitors

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70.

IB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description

MIC-2 Multi-instrument DATA SHEET

Positive-guided relay outputs: 4 safety contacts (N/O), instantaneous

Monitoring Technique. VARIMETER PRO Multifunction Measuring Relay MK 9300N, MH 9300

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

Power Supply HARTING pcon

E-STOP relays, safety gate monitors

E-STOP relay, safety gate monitor

Safety relays PNOZsigma

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

Electronic timer CT-AWS Impulse-OFF with 2 c/o contacts Data sheet

PNOZ s2. Safety relays. Operating Manual EN-07

PI-EX-ME-2NAM/COC-24VDC

Thermistor motor protection relays CM-MSS.12 and CM-MSS.13

Voltage Transducer UMT516 / MT516

LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E

Faults on the system Proximity switch connection technology:

ABB i-bus KNX HCC/S Heating/cooling circuit controller

Bulletin 817 Thermistor Protection Relay

E-STOP relays, safety gate monitors

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

QUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

Alarm Unit DG 3200 Control And Monitor Standard Signals

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

PSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

Electronic timer CT-ERD.12

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous

Transcription:

with coupling device AGH420 Insulation monitoring device for unearthed DC circuits (IT systems) for charging electric vehicles Preliminary datasheet isoev425_d00126_02_d_xxde/09.2015

with coupling device AGH420 Insulation monitoring device for unearthed DC circuits (IT systems) for charging electric vehicles Product description The ISOMETER s of the isoev425 series monitor the insulation resistance of unearthed AC/DC main circuits (IT systems) with nominal system voltages of 3(N)AC, AC, AC/DC 0 690 V or DC 0 1000 V. The main application fields are unearthed DC charging stations (mode 4 according to IEC 61851-23) for electric vehicles (IT systems) with nominal system voltages of DC 0 1000 V. Due to a separate supply voltage, de-energised systems can also be monitored. Application DC charging stations for electric vehicles according to IEC 61851-23 ISOMETER isoev425 Device features Monitoring for DC charging stations (mode 4 according to IEC 61851-23) for charging electric vehicles Mains voltage measurement (r.m.s.) with under-/overvoltage detection DC voltage measurement to earth (L+/ and L-/) Automatic adaptation to the system leakage capacitance up to 5 μf Automatic device self-test with connection monitoring Selectable start-up delay, response delay and delay on release Two separately adjustable response value ranges of 1 500kΩ (Alarm 1, Alarm 2) Alarm signalling via LEDs (AL1, AL2), a display and alarm relays (K1, K2) N/C operation or N/O operation selectable Measured value indication via multifunctional LCD Fault memory can be activated RS-485 (galvanically isolated) including the following protocols: BMS interface (Bender measuring device interface) for data exchange with other Bender components Modbus RTU IsoData (for continuous data output) Password protection to prevent unauthorised parameter changes Function The currently measured insulation resistance is indicated on the LC display. The ISOMETER s are factory-set to two response values 100/500 kω. If the reading is below the selected response value, the response delay "t on" begins. Once the response delay "t on" has elapsed, the alarm relays "K1/K2" switch and the alarm LEDs "AL1/AL2" light up. By means of the two isolated response values/alarm relays, messages can be evaluated separately. If the insulation resistance exceeds the release value (response value plus hysteresis), the alarm relays switch back to their initial position. The point of fault L+, L- or the symmetrical insulation resistance is indicated on the display. In the menu, the alarm relays can also be assigned to the point of fault. By activating the fault memory, the alarm relays and alarm LEDs remain in alarm state until the reset button is pressed or the supply voltage is disconnected. The device functions can be checked using the test button. Parameters are assigned to the device via the LCD and the control buttons on the front panel, as well as the BMS or Modbus RTU Interface. Connection monitoring The connections to the electrical system (L1/+ / L2/-) and earth (E/KE) as well as the connecting wires from the Isometer to the coupling device are periodically monitored every 24 hours after pressing the test button and connecting the supply voltage. In case of interruption of a connecting wire, the alarm relay K2 switches, the LEDs ON//AL1//AL2 flash and a message appears on the LC display as follows: "E.0x" for a fault in the connecting wires between both devices or system fault, "E.02" for a fault in the connecting wires to the system, "E.01 for a fault in the connecting wires to. After eliminating the fault, the alarm relays return to their initial position either automatically or by pressing the reset button. Measurement method The ISOMETER isoev425 works with different measurement methods adapted to the application with a maximum response time of 10 s. Standards The ISOMETER isoev425 series meets the device standards: DIN EN 61557-8 (VDE 0413-8), IEC 61557-8 Approvals and certifications 2 isoev425_d00126_02_d_xxde/09.2015

Operating elements 1 2 3 4 1 - LED "ON" (operation LED) flashes in case of interruption of the connecting wires E/KE or L1/+ / L2/- or system fault. 2 - Alarm LED "AL1", lights when the values fall below the set response value Alarm 1 and flashes in case of interruption of the connecting wires E/KE or L1/+ / L2/-, or system faults as well as in the case of overvoltage (can be activated). 3 - Alarm LED "AL2" lights when the values fall below the set response value Alarm 2 and flashes in case of interruption of the connecting wires E/KE or L1/+ / L2/- or system faults as well as in the case of undervoltage (can be activated). 4 - LC display 5 - Test button "T": Call up the self-test Arrow up button: Parameter change, move upwards in the menu 6 - Reset button "R": Delete stored insulation fault alarms Arrow down button: Parameter change, move downwards in the menu 7 - Menu button "MENU": Call up the menu system. Enter button: Confirms parameter changes 5 6 7 Wiring diagram U S E E Up Up KE A1 A2 2 AK2 GND AK1 AK1 GND AK2 E E Up AGH420 AK2 GND AK1 3 3 2 AK1 GND AK2 ON AL1 AL2 isoev425 < k ISOMETER 1 Up KE A1 A2 k Test / Reset L1/+ L2/- L3 1 - Connection to the supply voltage via fuse (line protection). If being supplied from an IT system, both lines have to be protected by a fuse. 2 - Connect each terminal separately to : The same wire cross section as for A1, A2 must be used 3 - Connect the terminals of AGH420 to the corresponding terminals of the isoev425 4 - Connection to the 3(N)AC, AC or DC system to be monitored 5 - Connection for the external combined test and reset button. 6 - Connection to alarm relay K1 7 - Connection to alarm relay K2 8 - Connection RS-485 (BMS bus) with termination switch R (on/off) Example: Connection of a BMS- Ethernet Gateway COM460IP. T R MENU 14 24 11 ON OFF L1/+ L1/+ L2/- 4 5 T/R A B K1 6 7 K2 L2/ T/R 14 24 11 A R 8 B RS-485 COM460IP isoev425_d00126_02_d_xxde/09.2015 3

Technical data ISOMETER isoev425 Insulation coordination acc. to IEC 60664-1/IEC 60664-3 Rated voltage (A1, A2) - (11, 14, 24) 300 V Rated impulse voltage 4 kv Overvoltage category III Pollution degree 3 Protective separation (reinforced insulation) between (A1, A2) - (AK1, GND, AK2, Up, KE, T/R, A, B) - (11, 14, 24) Voltage tests according to IEC 61010-1 2.2 kv Supply voltage Supply voltage U S AC 100 240 V/DC 24 240 V Tolerance of U S -20 +15 % Frequency range U S 47 63 Hz Power consumption 3 W, 9 VA IT system being monitored Nominal system voltage U n with AGH420 3(N)AC, AC 0 690 V/DC 0 1000 V Tolerance of U n AC + 15 %, DC +10 % Nominal system voltage range U n with AGH420 (UL508) AC/DC 0 600 V Frequency range of U n DC, 40 460 Hz Measuring circuit Permissible system leakage capacitance C e Permissible extraneous DC voltage U fg Response values Response value R an1 Response value R an2 Relative uncertainty R an Hysteresis R an Undervoltage detection Overvoltage detection Relative uncertainty U Relative uncertainty depending on the frequency 200 Hz Hysteresis U Time response Response time t an at RF 0.5 x Ran and Ce1 μf acc. to IEC 61557-8 Start-up delay t Response delay t on Delay on release t off 5 μf 1150 V 2 500 kω (500 kω)* 1 490 kω (100 kω)* ± 15 %, at least ±1 kω 25 %, at least 1 kω 30 V 1.14 kv (off)* 31 V 1.15 kv (off)* ± 5 %, at least ± 5 V -0.03 %/Hz 5 %, at least 5 V 10 s 0 10 s (0 s)* 0 99 s (0 s)* 0 99 s (0 s)* Displays, memory Indication LC display, multifunctional, not illuminated Display range measured value insulation resistance (R F) 1 kω 1 MΩ Operating uncertainty at R F 1 MΩ ± 15 %, at least ±1 kω Display range measured value nominal system voltage (U n) 30 V 1.15 kv rms Operating uncertainty ± 5 %, at least ± 5 V Relative uncertainty depending on the frequency 200 Hz -0.03 %/Hz Display range measured value system leakage capacitance at R F > 10 kω 0 10 μf Operating uncertainty ± 15 %, at least ± 2 μf Password off/0 999 (0, off)* Fault memory alarm messages on/(off)* Interface Interface/protocol RS-485/BMS, Modbus RTU, isodata Baud rate BMS (9.6 kbit/s), Modbus RTU (selectable), isodata (115,2 kbits/s) Cable length (9.6 kbits/s) 1200 m Cable: twisted pair, one end of shield connected to recommended: min. J-Y(St)Y 2x0.6 Termination resistor 120 Ω (0.25 W), internal, can be connected Device address, BMS bus, Modbus RTU 3 90 (3)* Switching elements Switching elements 2 x 1 N/O contact, common terminal 11 Operating principle N/C or N/O operation (N/O operation)* Electrical endurance in rated operating conditions 10 000 cycles Contact data acc. to IEC 60947-5-1: Utilisation category AC-12 AC-14 DC-12 DC-12 DC-12 Rated operational voltage 230 V 230 V 24 V 110 V 220 V Rated operational current 5 A 2 A 1 A 0.2 A 0.1 A Minimum contact rating 1 ma at AC/DC 10 V Environment/EMC EMC IEC 61326-2-4 Ambient temperatures: Operation -40 +70 C Transport -40 +80 C Storage -40 +70 C Classification of climatic conditions acc. to IEC 60721 3K7 (except condensation and formation of ice) 2K4 (except condensation and formation of ice) Long-term storage (IEC 60721-3-1) 1K5 (except condensation and formation of ice) Classification of mechanical conditions acc. to IEC 60721 3M4 2M2 Long-term storage (IEC 60721-3-1) 1M3 Connection Connection type push-wire terminal Nominal current 10 A Conductor sizes AWG 24-14 Stripping length 10 mm Connection properties: Rigid/flexible 0.2 2.5 mm² Flexible with ferrule with/without plastic sleeve 0.25 2.5 mm² Multiple conductor flexible with TWIN ferrule with plastic sleeve 0.5 1.5 mm² Opening force 50 N Test opening, diameter 2.1 mm Wiring of the terminals Up, AK1, GND, AK2 refer to technical data AGH420, under the heading "Connection" Other Operating mode continuous operation Mounting cooling slots must be ventilated vertically Degree of protection, internal components (IEC 60529) IP 30 Degree of protection, terminals (IEC 60529) IP 20 Enclosure material polycarbonate DIN rail mounting acc. to IEC 60715 Screw mounting 2 x M4 with mounting clip Documentation number D00126 Weight 150 g ( )* factory setting 4 isoev425_d00126_02_d_xxde/09.2015

Technical data coupling device AGH420 Insulation coordination acc. to IEC 60664-1/IEC 60664-3 Rated insulation voltage 1000 V Rated impulse voltage 8 kv Pollution degree 3 Overvoltage category III Protective separation (reinforced insulation) between (L1/+, L2/-) - (AK1, GND, AK2, Up, E) Voltage test, routine test (IEC 61010-1) 4.3 kv IT system being monitored Nominal system voltage range U n AC/DC 0 1000 V Tolerance of U n AC/DC +10 % Nominal system voltage range U n (UL508) AC/DC 0 600 V Measuring circuit Measuring voltage U m Measuring current I m at R F Internal DC resistance R i ± 45 V 400 μa 120 kω Environment/EMC EMC IEC 61326-2-4 Ambient temperatures: Operation -40 +70 C Transport -40 +80 C Storage -40 +70 C Classification of climatic conditions acc. to IEC 60721: 3K7 (except condensation and formation of ice) 2K4 (except condensation and formation of ice) Long-term storage (IEC 60721-3-1) 1K5 (except condensation and formation of ice) Classification of mechanical conditions acc. to IEC 60721: 3M4 2M2 Long-term storage (IEC 60721-3-1) 1M3 Connection Connection type push-wire terminal Nominal current 10 A Conductor sizes AWG 24-14 Stripping length 10 mm Connection properties: Rigid/flexible 0.2 2.5 mm² Flexible with ferrule with/without plastic sleeve 0.25 2.5 mm² Multiple conductor flexible with TWIN ferrule with plastic sleeve 0.5 1.5 mm² Opening force 50 N Test opening, diameter 2.1 mm Connection type terminals Up, AK1, GND, AK2 Single cables for terminals Up, AK1, GND, AK2:Cable lengths 0.5 m Connection properties 0.75 mm² Other Operating mode continuous operation Mounting cooling slots must be ventilated vertically Distance to adjacent devices from U n > 800 V 30 mm Degree of protection, internal components (IEC 60529) IP 30 Degree of protection, terminals (IEC 60529) IP 20 Enclosure material polycarbonate DIN rail mounting acc. to IEC 60715 Screw mounting 2 x M4 with mounting clip Weight 150 g ( )* factory setting Ordering information Supply voltage 1) US Type Art. no. AC DC 100 240 V, isoev425-d4-4 24 240 V B 7103 6401 47 63 Hz with AGH420 Device version with screw terminals on request. 1) Absolute values Dimension diagram XM420 Dimensions in mm Open the front plate cover in direction of arrow! Screw mounting Note: The above mounting clip is an accessory and must be ordered separately (see accessories). Accessories Description Mounting clip for screw mounting (1 piece per device) Art. no. B 9806 0008 isoev425_d00126_02_d_xxde/09.2015 5

Example of application TN-C-S system Source Distribution Installation Feeder Input DC charger Cable assembly Vehicle Connector Vehicle inlet Electric vehicle L1 L2 N L3 N RCD required by IEC 60364 Mode 4 IT system F Load Switch DC+ F DC + F DC - F V DC contactor RESS Inverter M R B Earthing at the source R A R AE R Earthing in the distribution RCD type A Isolating transformer Bender GmbH & Co. KG P.O. Box 1161 35301 Gruenberg Germany Londorfer Straße 65 35305 Gruenberg Germany Tel.: +49 6401 807-0 Fax: +49 6401 807-259 E mail: info@bender.de www.bender.de IMD F Control Pilot CP Function Note: Only one IMD may be active in each interconnected IT system DC- CP L N CP PP Control Pilot Function www.bender-de.com I n DC 6 ma (Option) PFC AC on-board charger with electrical separation R Tyre IMD (Option) Electrical Chassis / Protective equipotential bonding Air condition other consumers 14 V on-board power system (electrical separated) BENDERGroup isoev425_d00126_02_d_xxde / 09.2015 / pdf / Bender GmbH & Co. KG, Germany Subject to change! The specified standards take into account the version that was valid at the time of printing.