Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

MIC-2 Multi-instrument DATA SHEET

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

MIC-2 MKII, Multi-instrument DATA SHEET

MIC-2 MKII I/O module user s manual

DEIF A/S. Description of options. Option C2, Generator add-on protection package Automatic Gen-set Controller. Description of option

QUICK START GUIDE Generator Paralleling Controller, GPC-3 Generator Protection Unit, GPU-3/GPU-3 Hydro Paralleling and Protection Unit, PPU-3

DEIF A/S. Description of options. Option P1, Event and alarm printer Automatic Gen-set Controller. Description of option. Functional description

DEIF A/S. Description of options. Option C1 Generator add-on protection package Multi-line 2 version 2. Description of options. Functional description

Option X4 Additional Operator Panel AOP-2 Description of option Functional description

QUICK START GUIDE Generator Protection Unit GPU 300

Compact Genset Controller, CGC 400 What's in the delivery? The first steps Push-buttons and LEDs

MULTI-LINE 2 APPLICATION NOTES

MULTI-LINE 2 APPLICATION NOTES. Converting PPU-2 to PPU-3 Parameter conversion Wiring Options I/O list. Document no.: A SW version:

Option P1 Event and alarm printer Description of option Functional description Parameter list

Option H10, Multi-line 2 unit with USB service port. To be used when the multi-line 2 unit service port is USB type

APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET

DEIF A/S. Description of options. Option H4 Serial comm. CAT CCM communication Multi-line 2 version 2. Description of option Functional description

QUICK START GUIDE Paralleling and Protection Unit PPU 300

Getting started - USW 3.x Software download from internet Software installation Device setup Data backup

Description of options. user s manual. DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: Fax:

DEIF A/S. Description of options. Option A and B, Loss of mains protection package Automatic Gen-set controller. Description of options

QUICK START GUIDE Paralleling and Protection Unit PPU 300

MIC-2 MKII Profibus module user s manual

Inverter Interface Interface examples Wiring examples Communication topology

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S

Automatic Genset Controller, AGC-3 What's in the delivery Getting started The first steps Using the AGC

Automatic Genset Controller, AGC-4 What s in the delivery? Getting started The first steps Using the AGC

DATA SHEET Selectable AC transducer, TAS-331DG

AGC 200 Advanced Gen-set Controller What s in the delivery? Getting started The first steps Using the AGC 200

Genset control and protection with safety system

DEIF A/S. TAS-331DG Selectable AC transducer G (UK) Installation and start up instructions. Watt or var transducer

Automatic Genset Controller, AGC-4 What s in the delivery? Getting started The first steps Using the AGC

Advanced Graphical Interface, AGI 100

DATA SHEET Selectable AC transducer, TAS-321 DG

MULTI-LINE 2 DESCRIPTION OF OPTIONS

OPERATOR'S MANUAL Generator Paralleling Controller, GPC-3 - Generator Protection Unit, GPU-3/GPU-3 Hydro - Paralleling and Protection Unit, PPU-3

Option H8.x and H12.x External I/O modules Description of option Functional description

PowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006

CODESYS v. 2.3, Ethernet driver for AGI 3xx Use the CODESYS Ethernet driver in the AGI Creator Set up the CODESYS for use with the AGI Creator

Installation Manual. Multi Power Controller MPC-1 multi-line D

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

Compact Genset Controller, CGC 200 Mounting Terminals and wiring Commissioning, using the Utility Software and/or the front panel

Data Sheet. Digital Multifunctional Power Meter with LCD Display and Optional Modules WPM D

Option M2 Configurable engine control cards Multi-line 2 version B SW version 2.4X.X

Basic Gen-set Controller G (UK) SW version 2.1X.X. Terminal strip overview

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

with Backlight Graphic LCD Screen

PMC 530 Series Advanced Multifunction Meter

Compact Genset Controller, CGC 400 Generator control and protection Engine monitoring and protection Generator and mains breaker control RS485 Modbus

Engine Control Unit, ECU 100 Engine control Engine monitoring and protection Easy-to-read graphical display Integrated emulation software solution

DATA SHEET Applicable for offshore or nearshore

Operating instructions IO-Link master CabinetLine AL19xx

APPLICATION NOTES H-coupling

Option H3 Serial communication Profibus DP

IPD163C. Single-Phase Multifunction Meter User Manual Version: V1. August 20, 2017

USER MANUAL. WBV412U01 AC voltage transducer

EM133 EM133 TOU SMART ENERGY METER. Main Features. Multifunctional 3-Phase Smart Meter. Billing/TOU Energy Meter

mark150s mark150/485s DDC controllers Summary

!"!#$!%&'()!%*+,-%./0/123&&45&

Revenue Grade with DATA-LOGGING and WAVEFORM CAPTURE

Engine Control Unit, ECU 100 Engine control Engine monitoring and protection Easy-to-read graphical display Integrated emulation software solution

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L

General information. Display. Supply voltage. Input current

DATA SHEET. Advanced Energy Meter, AEM 380 & AEM 305

SDM120 SERIES. SDM120 series User Manual. Single phase two wire DIN rail energy meter (One module)

APPLICATION NOTES Translations

Generator Protection Unit, GPU Hydro Multi-line A SW version 2.4X.X

Voltage Transducer UMT516 / MT516

Operating instructions. Switching amplifier DN0210 DN / / 2015

DATA SHEET. Advanced Power Meter, APM 380 & APM 305

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

S800 I/O ABB Automation

APPLICATION NOTES DELOMATIC 4, DM-4 GAS/HYDRO

6ES7212-1BD30-0XB0. permissible range, lower limit (DC) permissible range, upper limit (DC)

USER MANUAL. WBI412F41 AC current transducer

SPM91 DIN Rail Single Phase Energy Meter Installation & Operation Manual V1.0

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

MARINE & OFFSHORE SHIP ENERGY MONITORING SYSTEM

Engines & Gen-sets N, page 1 of 6

Acuvim II Series Power Meter SNMP Protocol User's Manual

DATA SHEET IOM 200 analogue interface for AGC 200

Revenue Grade General Specifications

IMIO100 IMIO105. DDC controllers. Summary

PM130 PLUS PM130 PLUS POWER METER. Features. Models. Multifunctional 3-phase Power Meter

RGM180 Display Series

DATA SHEET Compact Genset Controller, CGC 200

Acuvim II Series Intelligent Power Meter (Web Accessible)

General information. Display. Supply voltage

USER MANUAL. WBI414F21 AC current transducer

EM QUICK START GUIDE. Quick Start Guide EM BG0504 REV.A2

Automatic Sustainable Controller, ASC Mounting Board slot positions Terminal strip overview I/O lists Wiring

Version 1.0c May 6, 2010 ATK3

WM20. Power analyzer for three-phase systems. Benefits. Description

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.

General information. Display. Supply voltage. Input current

General information. Supply voltage. Input current. Encoder supply. Power loss. Memory

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

Multifunction Transducer MT440

SEM3 - Embedded Micro Metering Module

Transcription:

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide Warnings and legal information Installation and terminals Communication I/O options Alarming Utility software More information Specifications Document no.: 4189320056C DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax: +45 9614 9615 info@deif.com www.deif.com

Warnings and legal information Legal information and responsibility DEIF takes no responsibility for installation or operation of the unit. If there is any doubt about how to install or operate the unit, the company responsible for the installation or the operation of the unit must be contacted. Electrostatic discharge awareness Sufficient care must be taken to protect the terminals against static discharges during the installation. Once the unit is installed and connected, these precautions are no longer necessary. Safety issues Installing the unit implies work with dangerous currents and voltages. Therefore, the installation should only be carried out by authorised personnel who understand the risks involved in working with live electrical equipment. CE-marking The unit is CE-marked according to the EMC directive for industrial environments, which normally covers the most common use of the product. The unit may not be opened by unauthorised personnel. If opened anyway, the warranty will be lost. Be aware of the hazardous live currents and voltages. Do not touch any AC measurement inputs as this could lead to injury or death. According to the instrument model, the current input type is for 1/5 A CTs or Flexible Current Transformer. Check the instrument model and connect the voltage and current inputs according to the following wiring diagrams. 2

Installation and terminals Installation Make sure the unit is installed in a dry and dust free environment. Avoid placing it near to heat, radiation and strong electrical interference sources. The working temperature range of the unit is from -25 C to 70 C. The unit can be installed into an IEC 92 mm DIN (square) or an ANSI C39.1 (4 round) form. Terminals 7 8 9 10 V1 V2 V3 VN Voltage input I11 I12 I21 I22 I31 I32 1 2 3 4 5 6 Current input 11 12 13 L/+ N/- Power supply Comm Port A B S 14 15 16 Communication Ground terminal connection Ground can be connected to ground on a grounded system (star point on the generator is connected to ground). On an IT system, terminal 13 must be left open, otherwise a false insulation error will occur. 3

Communication The default device address and the default baud rate of the DIN rail meter are 1 and 9600 respectively. Those two default values will always be used for the first minute after the meter is powered on. The device address and the baud rate of the meter will change to the user defined values after the first minute. Modbus communication settings The communication terminals are A, B, S (14, 15, 16). A is the differential signal +, B is the differential signal, and S is the shield. Up to 32 devices can be connected on an RS485 Modbus. The overall length of the Modbus cable cannot exceed 1000 m. When multiple units are connected serially on the same RS485 Modbus, each unit must be assigned a unique device address. This address can be any integer between 1 and 247. Ethernet communication settings (optional) AXM-Net default settings are: IP Address (192.168.1.254) Subnet Mask (255.255.255.0) Gateway (192.168.1.1) Primary DNS Server (202.106.0.20). To enter the settings webpage, the default password is: 12345678. Profibus communication settings (optional) AXM-PROFI default settings are: Device address 0 Profibus parameters can be set or viewed through communication using utility software. Please refer to the Profibus module user s manual chapter 3 Application of Profibus DP Protocol for operation details. 4

I/O module (option) Digital input (DI) An external power supply (16~30 V DC max load 2 ma) is required for the digital inputs. DI can be used as a pulse counter to monitor switch status or to monitor event sequences. Digital output (DO) Two modes available: alarm output and energy pulse output. One module can only support one mode at a time. In alarming mode, conditions can be set using the utility software. In energy pulse mode, output parameters can be set from the utility software (voltage 20~160 V AC/DC, max. load 100 ma). Relay output (RO) Two modes available: control (latch or pulse) and alarm output (latch only). One module can only support one mode at a time. In control mode, relays can be switched on and off from the utility software. In alarming mode, conditions can be set using the utility software (max voltage 250 V AC/30 V DC, load 3 A). Analogue input (AI) Each module supports 4-20 ma or 0-20 ma current input. Settings can be made from the utility software can be from the utility software. Analogue output (AO) Each module supports 4-20 ma or 0-20 ma current output. Settings can be made from the utility software. Power supply for DI 24 V isolated power supply is used as an auxiliary power supply for digital inputs. Output current 42 ma load, Max 21 X Digital Input (DI). 5

I/O module (option) Three types of I/O modules with different I/O combinations are available: Digital Input Relay Output VDC DI1 DI2 DI3 DI4 DI5 DI6 DIC RO1 RO2 ROC V+ V- AXM-IO1: 6 DI, 2RO, 1 Power Supply for DI Digital Input Analog Output Digital Output DI1 DI2 DI3 DI4 DIC AO1+ AO1- AO2+ AO2- DO1 DO2 DOC Digital Input Relay Output Analog Input AXM-IO2: 4 DI, 2 AO, 2 DO DI1 DI2 DI3 DI4 DIC RO1 RO2 ROC AI1+ AI1- AI2+ AI2- AXM-IO3: 4 DI, 2 RO, 2 AI Note: A maximum of 1 communication and 2 input/output modules can be used for each unit. I/O parameters can be set or viewed through communication using utility software. Please refer to the I/O modules user s manual chapter 3 for operation details. AXM-IO2 has two analogue outputs. Please notice that functionality is limited compared to traditional transducers. For more information, please read the I/O modules user s manual chapter 3. 6

Alarming Up to 16 alarming channels can be selected from 48 available parameters. Alarming channels and conditions can be set from the utility software. Please refer to MIC-2 MKII DIN user s manual section 4.4 for details. DIN Rail Installation Except the LCD display and the front panel control keys, the meter with DIN rail mount option includes the same functions as the panel mount version. The default device address and the default baud rate of the DIN rail meter are 1 and 9600 respectively. Those two default values will always be used for the first minute after the meter is powered on. The device address and the baud rate of the meter will change to the user-defined values after the first minute. Utility software The free utility software DEIF View is a user-friendly real time monitoring and data logging for energy saving and power quality analysis. This software is intended for users to monitor multiple parameters continuously. It allows for real-time monitoring and maintenance. Download DEIF View: www.deif.com/software/software-download More information The following can be downloaded from www.deif.com: MIC-2 MKII DIN user manual Ethernet TCP/IP - AXM-Net manual AXM-Profibus AXM-PROFI manual I/O modules - AXM manual MIC-2 MKII DIN utility software GSD file for Profibus 7

Specifications Voltage inputs Nominal voltage UN Overload capacity Nominal frequency and range L-N 400 V AC, L-L 690 V AC 1500 V continuous, 3250 V for 1min 50/60 Hz, 45 Hz to 65 Hz Current inputs Nominal current Overload capacity 5 A 10 A continuously, 100 A for 1 s FCT inputs Nominal voltage 100 mv Frequency Nominal frequency Frequency range 50/60 Hz, 45 Hz to 65 Hz Accuracy U, I and F Class 0.2 Harmonic U, I Class 5 DEIF reserves the right to change any of the above.

Specifications Voltage inputs Nominal voltage UN Overload capacity Nominal frequency and range L-N 400 V AC, L-L 690 V AC 1500 V continuous, 3250 V for 1min 50/60 Hz, 45 Hz to 65 Hz DEIF reserves the right to change any of the above.