SEQUESTR PREfERREd-CUToUT disconnects Mild STEEl SEQUESTR ExTERnal disconnect PaCkagE, TyPE 12 industry STandaRdS application finish SPECifiCaTionS

Similar documents
UL 508A Listed; Type 12; File No. E61997 cul Listed per CSA C22.2 No. 94; Type 12; File No. E CSA File No : Type 12

See also Accessories. Industrial Corrosion Inhibitors Floor Stand Kit PANELITE Enclosure Lights Overview Bulletin: A28X1, A28X2, A28XM.

Free-Stand Universal-Cutout Disconnects Free-Stand Type 4 Disconnects

Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories

Free-Stand Universal-Cutout Disconnects Free-Stand Type 12 Disconnects

Standard Product One-Door Enclosures. Free-Stand Universal-Cutout Disconnects Free-Stand Type 12 Disconnects

Free-Stand Universal-Cutout Disconnects Free-Stand Type 4 Disconnects

Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories

Free-Stand Stainless Steel Preferred-Cutout Disconnects Stainless Steel Two-Door Disconnects US 5,634,357 D 385,7683 BULLETIN: A21S4

Free-Stand Stainless Steel Preferred-Cutout Disconnects Stainless Steel Heavy Duty Disconnects US 5,634,357 D 385,7683 BULLETIN: A28S4

Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories

US 5,634,357 D 385,7683 Bulletin: A28S4

US 5,634,357 D 385,7683 Bulletin: A21S4

Free-Stand Type 12 Disconnect Enclosures. Heavy-Duty Free-Stand Disconnect Enclosure, Type 12

Free-Stand Disconnects and Accessories

Featured Products in this Chapter. Subject to change without notice PH FX hoffmanonline.com 2010 Pentair Technical Products

Arc Flash Safety Systems INDEX. Safety Systems. Arc Flash AF-8

Type 4 Disconnect Enclosures

Type 4X S.S. Disconnect Enclosures

Free-Standing Type 12 Enclosures

EMC Shielding Clear plated components (exterior painted) and a conductive fabric-over-foam gasket provide an HF2 level of shielding.

EMC Shielding Clear plated components (exterior painted) and a conductive fabric-over-foam gasket provide an HF2 level of shielding.

Fiberglass. Spec L. Non-Metallic. Hinge-Cover with 3-Point Latch or Quick-Release Latches, Type 4X

151 SAGINAW CONTROL & ENGINEERING STOCK PRICE LIST

EMC Shielding Clear plated components (exterior painted) and a conductive fabric-over-foam gasket provide an HF2 level of shielding.

INTERSAFE Data Interface Ports are mounted on an enclosure to allow programming access to devices inside without opening the enclosure door.

INTERSAFE DATA INTERFACE PORTS, TYPE 4/4X/12

CONCEPT Stainless Steel Wall-Mount Enclosures

Standard Product Left-Hinged

PROLINE ExtERNal ComPONENts. PROLINE tops and Bases

Standard Product Left-Hinged

TYPE 4/12 PREMIER SERIES

Panel Enclosures. Wall-Mount Enclosures Type 12 Premier Series Double-Door with Quarter-Turn Latches Data Sheet

WRD REMOVABLE HINGE PIN

Polycarbonate and ABS QLINE D

FTTX Fiber Optic Cabinet Packages Priority Electronics USA

Standard Product. Catalog Number. Width. Depth. mm 18 = = = = = = = = 400

Polycarbonate and ABS QLINE E

Polycarbonate and ABS QLINE E

Disconnect Enclosures

Technical Operating Information AC Unit (T150116G100) Replacement Filter No Wall-Mount Cabinets

Technical Operating Information AC Unit (T150116G100) Replacement Filter No

Polycarbonate and ABS QLINE D

Shelves, Keyboard Trays and Gland Plates Folding Shelves

NEMA Enclosure Solutions for Cisco WLAN Deployments

Featured Products - RU Marking Standard on Hoffman brand

PROLINE ExtERNaL COmPONENts 0-mm solid BasE Catalog Number Fits Frame B x C W (mm) W (in.) D (mm) D (in.) PB045 PB046 PB064 PB064HF2 PB065HF2 PB066

3630P Encl 34X28 Enclosure Panel. Features. Material, Color, and Finish. Dimensions and Weight. Descriptions

PROLINE ExtERNal ComPONENts. PROLINE tops and Bases

3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Product Description. Construction. Finish. Industry Standards

CHAPTER 3. Intro Page POLYPRO ULTRX QLINE D

FS66S Global Free-Stand Single and Dual Access, Type 4X

alid portable power cart epcc panel ccts EPCC-60 40" 60A, 120/208V 3PH 24 EPCC " 100A, 120/208V 3PH 24

TABLE I RANGE, POWER, OUTPUT (CONDUCTIVITY MEASUREMENTS)

WIRE AND CABLE MANAGEMENT

ROLLING COUNTER SHUTTERS

Installation, Operation

INDUSTRIAL MODULAR ENCLOSURES EQUIPMENT PROTECTION

Industrial Modular Enclosures

Top Door Opening, Height mm/in

1510 MOTOR CONTROLLERS

TopConsole system TP. Combination options 1-part 2-part 3-part. System accessories Page 537 Monitors, keyboards From page 796 Climate control Page 389

Ex-CELL Stainless Steel and Painted Steel Enclosures

Vertiv VR Rack 1.0 GENERAL

Series 575. Vertical Flow Modular Softwall Cleanroom. Series 575 Vertical Flow Modular Softwall Cleanroom

Brasch Washdown Unit Heaters

Maximum Reliability & Excellent Value. Features. UL Listed Withstand & Close-On Ratings. Series 300 Power Transfer Switches

PowerFlex 750-Series Power Option Cabinets

DOCKING STATION SPECIFICATIONS

NOW AVAILABLE AT IP66 RATING. Fast Fit. 3 phase distribution boards. clipsal.com. Designed for easy installation and fast wiring

SECTION SWITCHBOARDS

Model 7416LED

Remote Site Products

PanelView Plus/VersaView CE Terminals and Display Modules

IP Enclosures Product Overview 2015

Site Preparation CHAPTER

Product Capabilities and Overview Vertical Enclosures

CONTROL PANEL WIRING SPECIFICATIONS

SECTION WIRING DEVICES PART 1 - GENERAL. A. Drawings and Division 1 Specification Sections, apply to this Section.

PowerLogic High Density Metering System 1-Meter Enclosure

Metal-enclosed interrupter 5 kv-15 kv usa.siemens.com/siebreak

1/2 Introduction. SIMBOX LC 1/7 Introduction 1/8 Flush-mounting and surfacemounting. 1/9 Dimensional drawings

User s Manual. ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

Innovative POWER Solutions

Integration Fully integrated Controls, Power Monitoring, Generator Paralleling, and Switching Schemes as a complete turnkey solution.

Rack- and Panel-Mount Power Distribution Units (PDUs)

Power-Over-Ethernet Weatherproof 18" x 16" x 8" Enclosure with Equipment Mounting Plate and Cooling Fans

SECTION PROJECTOR LIFTS AND MOUNTS. A. Refer to Section [ Submittal Procedures] [Insert section number and title].

SECTION SWITCHGEAR

Argenta W A L L M O U N T I N G M E T A L C A B I N E T S

NetShelter SX Cable Management. Organize large volumes of cables from networking switches and patch panels

INSTALLATION INSTRUCTIONS FOR

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

SECTION PANELBOARDS

Series 75. Steel Roller Shutters

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

194E FA 32 E P11 P11 6

920 Remote Control (RC) Switches

Transcription:

Spec-224 Mild Steel SEQUESTR External isconnect Package, Type 12 INUSTRY STANARS UL 58A Listed; Type 12; File No. E61997 cul Listed per CSA C22.2 No. 94; Type 12; File No. E61997 NEMA/EEMAC Type 12 CSA File No. 42186: Type 12 IEC 6529, IP55 APPLICATION The SEQUESTR External isconnect Enclosure Package helps mitigate arc flash occurrences when working on interior components by isolating incoming power from the main enclosure. Shipped as one unit for new installations, the disconnect switch and fuse block/circuit breaker are mounted in the external enclosure, with terminal connections to bring power to the main enclosure. The package includes a main enclosure and a SEQUESTR enclosure. The SEQUESTR enclosure can be ordered separately to retrofit in existing A28 and A34 main enclosure bulletins. SPECIFICATIONS A28 main enclosure,.121-in. steel (11 gauge) A7 SEQUESTR external disconnect enclosure,.6-in. steel Seams continuously welded and ground smooth External formed body flange channels away liquids Heavy duty lifting eyes anchored into reinforced top Removable centerposts for easy back panel installation No disconnect cutout on main control cabinet Interlocks doors of main control enclosure when disconnect switch is powered ON Mechanical interlock on main control enclosure activated by master door prevents slave door from being opened first Provision for pass-through power into the main enclosure Preferred disconnect cutout Quarter-turn, slotted latches on SEQUESTR Enclosure Rugged POWERGLIE Handle with three-point latch on main control enclosure Concealed, easy-to-remove hinges Grounding studs on body Bonding provision on door Conductive back panel included in SEQUESTR External isconnect Enclosure Optional back panel for main control cabinet for maximum ordering flexibility SEQUESTR External isconnect Enclosure is shipped unattached for easy disconnect installation Oil-resistant gasket FINISH SEQUESTR External isconnect Enclosure ANSI 61 gray polyester powder paint inside and out Two finishes are available for A28 main enclosure: ANSI 61 gray polyester powder paint outside and inside, or ANSI 61 gray polyester powder paint outside and white inside SEQUESTR External isconnect Enclosure panel has conductive finish ACCESSORIES Panels for Type 3R, 4, 4X, 12 and 12 Enclosure Operator Adapters for Universal Cutouts PANELITE Enclosure Lights Floor Stand Kit SPECTRACOOL Indoor/Outdoor HF Side-Mount Filter Fans Steel, Stainless Steel and Non-Metallic Window Kits Electric Heaters HOL-SEALERS Hole Seals INTERSAFE ata Interface Ports, Type 4/4X/12 Bulletin: A28X1, A28X2, A28XM, A7 1 isconnect SUBJECT TO CHANGE WITHOUT NOTICE nvent.com/hoffman

Standard Product One-oor Enclosure A72X2818FTCLPG 72.12 x 28.25 x 18.12 1832 x 718 x 46 A72X2818FTCLP 72.12 x 28.25 x 18.12 1832 x 718 x 46 A72X3418FTCLPG 72.12 x 34.25 x 18.12 1832 x 87 x 46 A72X3418FTCLP 72.12 x 34.25 x 18.12 1832 x 87 x 46 A72X418FTCLPG 72.12 x 4.25 x 18.12 1832 x 122 x 46 A72X418FTCLP 72.12 x 4.25 x 18.12 1832 x 122 x 46 A84X418FTCLPG 84.12 x 4.25 x 18.12 2137 x 122 x 46 A84X418FTCLP 84.12 x 4.25 x 18.12 2137 x 122 x 46 A9X418FTCLPG 9.12 x 4.25 x 18.12 2289 x 122 x 46 A9X418FTCLP 9.12 x 4.25 x 18.12 2289 x 122 x 46 A9X42FTCLPG 9.12 x 4.25 x 2.12 2289 x 122 x 511 A9X42FTCLP 9.12 x 4.25 x 2.12 2289 x 122 x 511 A84X424FTCLPG 84.12 x 4.25 x 24.12 2137 x 122 x 613 A84X424FTCLP 84.12 x 4.25 x 24.12 2137 x 122 x 613 A9X424FTCLPG 9.12 x 4.25 x 24.12 2289 x 122 x 613 A9X424FTCLP 9.12 x 4.25 x 24.12 2289 x 122 x 613 Gray 42.25 173 White 42.25 173 Gray 48.25 1226 White 48.25 1226 6. 6. 9. 9. 9. 9. 6. 6. 9. 9. Panel Size Panel A72PM28 6. x 21.75 4 x 552 A72PM28 6. x 21.75 4 x 552 A72PM34 6. x 27.75 4 x 75 A72PM34 6. x 27.75 4 x 75 A72PM4 6. x 33.75 4 x 857 A72PM4 6. x 33.75 4 x 857 A84PM4 72. x 33.75 A84PM4 72. x 33.75 A9PM4 72. x 33.75 A9PM4 78. x 33.75 A9PM4 72. x 33.75 A9PM4 78. x 33.75 A84PM4 72. x 33.75 A84PM4 72. x 33.75 A9PM4 72. x 33.75 A9PM4 78. x 33.75 nvent.com/hoffman PH 763.422.2211 isconnect 2

Standard Product Two-oor Enclosures A72X5418FTCLPG 72.12 x 54.5 x 18.12 1832 x 1384 x 46 A72X5418FTCLP 72.12 x 54.5 x 18.12 1832 x 1384 x 46 A72X6618FTCLPG 72.12 x 66.5 x 18.12 1832 x 1689 x 46 A72X6618FTCLP 72.12 x 66.5 x 18.12 1832 x 1689 x 46 A72X7818FTCLPG 72.12 x 78.5 x 18.12 1832 x 1994 x 46 A72X7818FTCLP 72.12 x 78.5 x 18.12 1832 x 1994 x 46 A84X7818FTCLPG 84.12 x 78.5 x 18.12 2137 x 1994 x 46 A84X7818FTCLP 84.12 x 78.5 x 18.12 2137 x 1994 x 46 A9X7818FTCLPG 9.12 x 78.5 x 18.12 2289 x 1994 x 46 A9X7818FTCLP 9.12 x 78.5 x 18.12 2289 x 1994 x 46 A9X782FTCLPG 9.12 x 78.5 x 2.12 2289 x 1994 x 511 A9X782FTCLP 9.12 x 78.5 x 2.12 2289 x 1994 x 511 A72X7824FTCLPG 72.12 x 78.5 x 24.12 1832 x 1994 x 613 A72X7824FTCLP 72.12 x 78.5 x 24.12 1832 x 1994 x 613 A84X7824FTCLPG 84.12 x 78.5 x 24.12 2137 x 1994 x 613 A84X7824FTCLP 84.12 x 78.5 x 24.12 2137 x 1994 x 613 A9X7824FTCLPG 9.12 x 78.5 x 24.12 2289 x 1994 x 613 A9X7824FTCLP 9.12 x 78.5 x 24.12 2289 x 1994 x 613 Gray 68.5 174 White 68.5 174 Gray 8.5 245 White 8.5 245 Gray 92.5 235 White 92.5 235 Gray 92.5 235 White 92.5 235 Gray 92.5 235 White 92.5 235 Gray 92.5 235 White 92.5 235 Gray 92.5 235 White 92.5 235 Gray 92.5 235 White 92.5 235 Gray 92.5 235 White 92.5 235 6. 6. 9. 9. 9. 9. 6. 6. 9. 9. Stiffener Locations None None None None 21. 533 21. 533 24. 61 24. 61 24. 91 24. 91 24. 61 24. 61 24. 61 24. 61 24. 61 24. 61 24. 61 24. 61 24. 61 24. 61 Panel Size Panel A72PM54 6. x 48. 4 x 1219 A72PM54 6. x 48. 4 x 1219 A72PM66 6. x 6. 4 x 4 A72PM66 6. x 6. 4 x 4 A72PM78 6. x 72. 4 x 1829 A72PM78 6. x 72. 4 x 1829 A84PM78 72. x 72. A84PM78 72. x 72. A9PM78 78. x 72. A9PM78 78. x 72. A9PM78 78. x 72. A9PM78 78. x 72. A72PM78 6. x 72. 4 x 1829 A72PM78 6. x 72. 4 x 1829 A84PM78 72. x 72. A84PM78 72. x 72. A9PM78 78. x 72. A9PM78 78. x 72. 3 isconnect SUBJECT TO CHANGE WITHOUT NOTICE nvent.com/hoffman

Standard Product Three-oor Enclosures A72X3EQ18FTCLPG 72.12 x 1.75 x 18.12 Gray 114.75 1832 x 2559 x 46 2915 A72X3EQ18FTCLP 72.12 x 1.75 x 18.12 White 114.75 1832 x 2559 x 46 2915 A72X3EW18FTCLPG 72.12 x 118.75 x 18.12 Gray 132.75 1832 x 316 x 46 A72X3EW18FTCLP 72.12 x 118.75 x 18.12 White 132.75 1832 x 316 x 46 A84X3EW18FTCLPG 84.12 x 118.75 x 18.12 Gray 132.75 2137 x 316 x 46 A84X3EW18FTCLP 84.12 x 118.75 x 18.12 White 132.75 2137 x 316 x 46 A84X3EW24FTCLPG 84.12 x 118.75 x 24.12 Gray 132.75 2137 x 316 x 613 A84X3EW24FTCLP 84.12 x 118.75 x 24.12 White 132.75 2137 x 316 x 613 A9X3EW24FTCLPG 9.12 x 118.75 x 24.12 Gray 132.75 2289 x 316 x 613 A9X3EW24FTCLP 9.12 x 118.75 x 24.12 White 132.75 2289 x 316 x 613 6. 6. 6. 6. 9. 9. Large Panel A72PM66 1 6. x 6. 4 x 4 A72PM66 1 6. x 6. 4 x 4 A72PM78 1 6. x 72. 4 x 1829 A72PM78 1 6. x 72. 4 x 1829 A84PM78 1 72. x 72. A84PM78 1 72. x 72. A84PM78 1 72. x 72. A84PM78 1 72. x 72. A9PM78 1 78. x 72. A9PM78 1 78. x 72. Small Panel Small Panels Small Panels A72PM34 1 6. x 33.75 4 x 75 A72PM34 1 6. x 27.75 4 x 75 A72PM4 1 6. x 33.75 4 x 857 A72PM4 1 6. x 33.75 4 x 857 A84PM4 1 72. x 33.75 A84PM4 1 72. x 33.75 A84PM4 1 72. x 33.75 A84PM4 1 72. x 33.75 A9PM4 1 78. x 33.75 A9PM4 1 78. x 33.75 nvent.com/hoffman PH 763.422.2211 isconnect 4

Standard Product Four-oor Enclosures A84X4EW18FTCLPG 84.12 x 158. x 18.12 2137 x 413 x 46 A84X4EW18FTCLP 84.12 x 158. x 18.12 2137 x 413 x 46 A9X4EW18FTCLPG 9.12 x 158. x 18.12 2289 x 413 x 46 A9X4EW18FTCLP 9.12 x 158. x 18.12 2289 x 413 x 46 A84X4EW24FTCLPG 84.12 x 158. x 24.12 2137 x 413 x 613 A84X4EW24FTCLP 84.12 x 158. x 24.12 2137 x 413 x 613 A9X4EW24FTCLPG 9.12 x 158. x 24.12 2289 x 413 x 613 A9X4EW24FTCLP 9.12 x 158. x 24.12 2289 x 413 x 613 Gray 172. White 172. Gray 172. White 172. Gray 172. White 172. Gray 172. White 172. 6. 6. 9. 9. 6. 6. 9. 9. Large Panel Panels Panels A84PM78 2 72. x 72. A84PM78 2 72. x 72. A9PM78 2 78. x 72. A9PM78 2 78. x 72. A84PM78 2 72. x 72. A84PM78 2 72. x 72. A9PM78 2 78. x 72. A9PM78 2 78. x 72. 5 isconnect SUBJECT TO CHANGE WITHOUT NOTICE nvent.com/hoffman

Standard Product Five-oor Enclosures A84X5EW18FTCLPG 84.12 x 197.75 x 18.12 Gray 211. 2137 x 523 x 46 A84X5EW18FTCLP 84.12 x 197.75 x 18.12 White 211. 2137 x 523 x 46 A9X5EW18FTCLPG 9.12 x 197.75 x 18.12 Gray 211. 2289 x 523 x 46 A9X5EW18FTCLP 9.12 x 197.75 x 18.12 White 211. 2289 x 523 x 46 A84X5EW24FTCLPG 84.12 x 197.75 x 24.12 Gray 211. 2137 x 523 x 613 A84X5EW24FTCLP 84.12 x 197.75 x 24.12 White 211. 2137 x 523 x 613 A9X5EW24FTCLPG 9.12 x 197.75 x 24.12 Gray 211. 2289 x 523 x 613 A9X5EW24FTCLP 9.12 x 197.75 x 24.12 White 211. 2289 x 523 x 613 6. 6. 9. 9. 6. 6. 9. 9. Large Panel A84PM78 1 72. x 72. A84PM78 1 72. x 72. A9PM78 1 78. x 72. A9PM78 1 78. x 72. A84PM78 1 72. x 72. A84PM78 1 72. x 72. A9PM78 1 78. x 72. A9PM78 1 78. x 72. Small Panel Small Panels Small Panels A84PM4 1 72. x 33.75 A84PM4 1 72. x 33.75 A9PM4 1 78. x 33.75 A9PM4 1 78. x 33.75 A84PM4 1 72. x 33.75 A84PM4 1 72. x 33.75 A9PM4 1 78. x 33.75 A9PM4 1 78. x 33.75 nvent.com/hoffman PH 763.422.2211 isconnect 6

Standard Product Six-oor Enclosure A84X6EW24FTCLPG 84.12 x 236. x 24.12 2137 x 5994 x 613 A84X6EW24FTCLP 84.12 x 236. x 24.12 2137 x 5994 x 613 A9X6EW24FTCLPG 9.12 x 236. x 24.12 2289 x 5994 x 613 A9X6EW24FTCLP 9.12 x 197.75 x 24.12 2289 x 523 x 613 Gray 25. 635 White 25. 635 Gray 25. 635 White 25. 635 6. 6. 9. 9. Large Panel Panels A84PM78 3 72. x 72. A84PM78 3 72. x 72. A9PM78 3 78. x 72. A9PM78 3 78. x 72. Optional Terminal Plates escription ATBP36. 3 and 6 amp switches ATBP1. 1 amp switches ATBP2. 2 amp switches Terminal Plates rated IP2 7 isconnect SUBJECT TO CHANGE WITHOUT NOTICE nvent.com/hoffman

isconnect Mounting Space isconnects are located by dimension E1. Wiring space W1 is available when disconnect is installed in the enclosure. See the Hoffman Specifier s Guide Technical Information chapter for E1 Spacing by Enclosure Height for various disconnect switch manufacturers. Refer to National Electrical Code 28 article 43.1(B) for wiring space required for line side conductors to be connected to disconnect. Verify your application to determine if wiring space is adequate. Consult Space Occupied by isconnect drawing to determine whether the disconnect device you are using will fit the enclosure size you have selected. Consult disconnect manufacturer for F1 and G1 dimensions. Mild Steel SEQUESTR Preferred-Cutout Overview These enclosures will NOT accept Allen-Bradley Bulletin 1494F disconnect devices or Bulletin 1494 circuit breaker operators. Schneider Square Class 9422 disconnect switches with flangemount left-hand variable-depth operating mechanisms and Class 9422 flange-mount left-hand variable-depth operating mechanisms for circuit breakers. These enclosures will NOT accept Square Class 9422 bracketmounted disconnect devices, Class 9422TGI or TG2 devices. APPLICATION The SEQUESTR enclosures have the standard preferred cutout on the left-hand flange. They accept up to 2A disconnect switches from Allen-Bradley and Schneider Square. SEQUESTR cutouts are designed to house the following: Allen-Bradley Bulletin 1494V SX left-hand disconnect switches with flangemount variable-depth operating mechanisms and Bulletin 1494V flange-mount variable depth operating mechanisms for circuit breakers. Bulletin 1494U Allen-Bradley universal disconnect switches with flange-mount handles for either variable-depth or cableoperated mechanisms. ORERING isconnect switch (or circuit breakers), operating handle and operating mechanism are not furnished with enclosure. Consult the Hoffman Specifier s Guide Technical Information chapter for wire bend information. Consult drawings to match the disconnect device you are using with the correct enclosure size. A complete assembly consists of: 1. An enclosure 2. oor interlock brackets 3. oor latching system (2-point on SEQUESTR Enclosure, 3-point on main control cabinet doors) 4. Instructions to locate and install disconnect 5. Grounding hardware kit 6. Conductive panel in SEQUESTR External isconnect Enclosure nvent.com/hoffman PH 763.422.2211 isconnect 8