Datasheet RCUXXYY EAE KNX Room Control Unit RCUXXYY DT R1.0. General Description. EAE Technology Page 1/10

Similar documents
EAE KNX Room Control Unit Product Manual RCUXXYY

EAE KNX Switch Actuator

Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

ABB i-bus KNX Switch Actuator, x-fold, 6 A, MDRC SA/S x.6.1.1, 2CDG x R0011

ABB i-bus KNX HCC/S Heating/cooling circuit controller

ABB i-bus KNX Fan Coil Actuators FCA/S Product Manual

ABB i-bus KNX Fan Coil Actuators FCA/S Product Manual

ABB i-bus KNX Fan Coil Actuator, PWM, MDRC FCA/S , 2CDG110195R0011

ABB i-bus KNX Switch Actuator, x-fold, 10 A, MDRC SA/S x , 2CDG11015xR0011

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2TAZ710xx1R2161

Switching Actuators N530, 6AX Switching Actuators N532, 10AX Switching Actuators N534, 16/20AX

ABB i-bus KNX Analogue Actuator, 4-fold, MDRC, 0-10 V, 0-20 ma AA/S 4.1.2, 2CDG110202R0011

Operating voltage Maximum

ABB i-bus KNX BCI/S Boiler/Chiller Interface

ABB i-bus EIB / KNX Blower/Fan Coil-Aktuator LFA/S 1.1, LFA/S 2.1. Product Manual. Intelligent Installation Systems ABB

ABB i-bus KNX Switch Actuator, Current Detection, x-fold, 16/20 A, C-Load, MDRC SA/S x , 2CDG1101xxR0011

Relay actuators & Status indicating modules

ABB i-bus KNX Blower/Fan Coil-Actuator LFA/S 1.1, LFA/S 2.1. Product Manual. Intelligent Installation Systems ABB

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

Product and functional description

ABB i-bus KNX DALI Light Controller, 8-fold, MDRC DLR/S M, 2CDG110101R0011

K-BUS R. Dimming Actuators. User manual-ver. 4 KA/D KA/D KA/D KA/D 04.T1.1 ADTV-04/16.1 KA/D 04.L1.1 ADLD-04/

ABB i-bus KNX Analogue Input, 4-fold, MDRC AE/S , 2CDG110190R0011

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

ABB i-bus KNX Logic Controller ABA/S 1.2.1, 2CDG110192R0011

Product and functional description

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

1 Safety instructions. 2 Device components. 3 Function. Control unit, 1-10 V 3-gang. Order-No. : Operating instructions

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

RM35JA32MR Current control relay 0.15A 15A, 2 C/O

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

ABB i-bus KNX Room Master Basic RM/S 1.1 Product Manual

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

Switch Actuator, 4-fold, 20 A, MDRC AT/S , GH Q R0111

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

Control unit for lux control, MDRC Type: SL/S 50.1, GH Q R0001

High-performance switching actuators

Siemens Spares. RL 513D23 Switching actuator (relay), 3 x 6A. Technical Product Information

1 Safety instructions. 2 Device components. 3 Function. Control unit 1-10 V, 3-gang. Art.-No.: 2193 REG. Operationsmanual

ABB i-bus KNX Room Master Basic RM/S 1.1 Product Manual

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA

PI-EX-ME-2NAM/COC-24VDC

Switch Actuator, 4-fold, 16 A, MDRC AT/S , GH Q R0111

Lighting Control. Air Conditioning. Timing / Scheduling. Curtains/Blinds

Product and functional description

ABB i-bus KNX Binary Inputs BE/S Product Manual

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA 250 V AC

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70.

VEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA

Push Button Interface UP 220D31

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

PI-EX-ME-2NAM/COC-120VAC

RM35TF V AC

RM35LM33MW liquid level control relay RM35-L V AC/DC

Product and functional description

Product and functional description

Product and Applications Description. Application programs. instabus EIB Technical Product Information. February 2012

252F 5WG FB_1 DELTA

The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal.

RM35TF. Main. Product or component type. Product specific application. Relay monitored parameters 250 V AC 5 A AC

ABB i-bus KNX Blower Actuator FCL/S x Product Manual

UNIVERSAL DIMMER DIM02SA/500U

RM22LA32MR Level control relay RM22-L V AC/DC - 2 C/O

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

UNIVERSAL DIMMER DIM02SA/500U

UNIVERSAL DIMMER DIM04SA/500U

ABB i-bus KNX AC/S Application Controller

ABB i-bus. KNX JRA/S Blind/Roller Shutter Actuator with Binary Inputs Product Manual

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/ O

Control elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.

EAE KNX IP Router Product Manual IPR100 (sayfa düzeni ve foto düzenlemesi gerekli)

Extension module for lighting control

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

RE22R2CMR Off-delay Timing Relay s 300h V AC/DC - 2C/O

s Climatix AHU ext. module 14 I/O POL955.XX/XXX Climatix

VEO. V2ZS V AC/DC Art.Nr.: V2ZS20P V AC/DC Art.Nr.: TECHNICAL DATA

RM4JA01F current measurement relay RM4-J - range ma V AC

ABB i-bus KNX Room Master Premium RM/S 2.1 Product Manual

RM35LM33MW liquid level control relay RM35-L V AC/DC

Device technology. Supply Bus voltage V DC. Current consumption via bus. Accuracy in the range 300 1,000 ppm 1,000 2,000 ppm 2,000 5,000 ppm

11 Series - Light Dependent Relay A. Features pole 17.5 mm wide. 1 pole zero hysteresis 4 position selector

QUINT-PS/ 1AC/24DC/ 5

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

RE22R2KMR Off-delay Timing Relay s 10min V AC/DC - 2C/O

RE8YG31BUTQ industrial timing relay s - type Qc - 24 V AC/DC, V AC - 1C/O

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

PHOENIX CONTACT - 12/2007

EY-EM : Remote I/O module, ecolink

Engine Control Unit, ECU 100 Engine control Engine monitoring and protection Easy-to-read graphical display Integrated emulation software solution

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

Operating instructions. Switching amplifier DN0210 DN / / 2015

RM4JA32MW current measurement relay RM4-J - range A V AC DC

RE8TA31BU industrial timing relay s - type A - 24 V AC/DC, V AC - 1 C/O

RM4TA32 three-phase network control relay RM4-T - range V

ABB i-bus EIB. Shutter Actuator, 2-fold, 6 A, 230 VAC, MDRC JA/S 2.6.1, GH Q R0111

1 pole 17.5 mm wide 2,000 2, ,000 1,000 halogen W DC / / / / 30

Transcription:

General Description Room Control Unit RCU Series are designed as an all in one product for different room layouts such as apartments, hotel rooms, hospitals and residences. Available versions of EAE RCU Series: RCU2018 RCU2016 RCU1212 RCU0808 RCU2000 RCU2000 RCU1200 RCU0800 Note: RCUXXYY where XX denotes the number of outputs and YY number of inputs. RCUXXYY has XXx16A relay outputs. These outputs are grouped as 5/4/3/2 independent output channels for XX = 20/16/12/8 respectively. Each channel can be configured to have different modes of operation as follows, Switching output x4 AC Blind x2 DC Blind x1 2 Point valve x2 3 point valve x2 Room Control Unit covers all requirements of the electrical installation of room applications and offers following functions in a one product. Switching lighting Switching loads Controlling AC/DC blinds Controlling fan coils (2 & 3 point valve) Dry contact inputs Suitable for switching resistive, capacitive and inductive loads as well as fluorescent lamp loads according to EN 60 669. As a switch output device provides following function list, Staircase External logic Internal logic Priority Threshold Operating hour Sweep RCUXXYY has YY independent input channels. Input channel operates as universal interface with following functions, Switch / push button input Dimmer control Control of shutter/blinds Value sending Scene control Counter for count pulse Manual control is possible for each channel through the builtin button panel. 220V auxiliary power is NOT required. EAE Technology www.eaetechnology.com Page 1/10

Technical Data RCUXXYY Series Type of protection IP 20 EN 60 529 Safety class II EN 61 140 Power supply : - Voltage 21V 30V DC, SELV - Current consumption 10 ma External supply - - Connections - Screw terminals 0,5 3,31 mm² solid and stranded wire 0,5 3,31 mm² stranded wire with ferrule 0.5 Nm - Max tightening torque - KNX Bus connect terminal Output - Number XX output - Switching voltage 250 V AC; 50/60 Hz - Switching current 250 V AC - Switching current 250 V AC, capacitive loads 16A / AC 1 16A (200µF) - Maximum switching power 4000 VA - Mechanical life > 1 x 10 6 Type of load - Incandescent lamp 4000 W - Halogen lamp 4000 W - Inductive loads, transformer 2000 W - Electronic drivers 1500 W Type of contact - Potential-free, bistable Input - Number YY binary inputs - Scanning voltage 5 V pulsed - Current 1 ma - Cable length < 300 m Installation - 35mm mounting rail EN 60 715 Operating elements - LED (red) and button For physical address Temperature range - Ambient -5 C + 45 C - Storage -25 C + 55 C Humidity - max. air humidity 85 % no moisture condensation Dimensions 66 x W x 90mm Width W in mm Width W in units (18 mm modules) 180 mm 10 modules Weight 0,65 kg Box Plastic, polycarbonate, colour grey CE In accordance with the EMC guideline and low voltage Application program Communications objects Number of addresses(max) Number of assignments(max) 254 255 255 EAE Technology www.eaetechnology.com Page 2/10

Grouping Topology Visual Lighting AC Blind DC Blind Fan Coil Fan Control Valve Control RCU20YY A1A2-B1B2 J1J2 A-B-C-D-E- F-G-H-I-J GH IJ GH IJ GH IJ RCU16YY A1A2-B1B2 H1H2 A-B-C-D-E- F-G-H GH GH GH RCU12YY RCU08YY A1A2-B1B2 F1F2 A1A2-B1B2 D1D2 A-B-C-D-E- F AB CD EF AB CD EF AB CD EF A-B-C-D AB CD AB CD AB CD For lighting and AC Blinds; - channels can be used individually, in example: A1 & A2 can be used as a switch for lighting and B1 & B2 can be used as an AC Blind etc. Red coloured groups in above visual For DC Blind, Fan Coil Fan Control and Valve Control; - subsequent channels are linked together, in example: G1G2 and H1H2 have to be used together for DC Blind etc. Blue coloured groups in above visual EAE Technology www.eaetechnology.com Page 3/10

Connection Examples RCU0808 Connection Diagram 1 Connection Diagram 2 EAE Technology www.eaetechnology.com Page 4/10

RCU1212 Connection Diagram 3 Connection Diagram 4 EAE Technology www.eaetechnology.com Page 5/10

RCU1616 Connection Diagram 5 Connection Diagram 6 EAE Technology www.eaetechnology.com Page 6/10

RCU2018 Connection Diagram 7 Connection Diagram 8 EAE Technology www.eaetechnology.com Page 7/10

Scale Drawings RCUXXYY RCU2018 RCU1616 EAE Technology www.eaetechnology.com Page 8/10

RCU1212 RCU0808 EAE Technology www.eaetechnology.com Page 9/10

Scale Dimensions RCUXXYY EAE Technology www.eaetechnology.com Page 10/10