Software Version: Supported Models 1. Added support for cmt-g01 model. This model is a gateway device; therefore, it is not possible to generate a cmt-g01 project from another HMI project simply by changing the model type. 2. Added support for cmt Gateway Viewer. cmt Gateway Viewer is a simulation program exclusive for cmt-g01. cmt Gateway Viewer simulates connection with the OPC UA server, allowing the user to browse and monitor nodes on the OPC UA server.
New Features EasyBuilder Pro 1. Added Contact Editor object. Object Name Shortcut Icon Function Object Preview Contact Editor Enables adding / modifying / deleting of e-mail contacts dynamically. Object Preview (cmt) 2. For Enhanced Security Mode: a. Added support for [Read-only] mode. Under this mode, the settings can be viewed but not changed. Passwords may be masked by asterisks (*). b. Added the option: [Use existing user accounts on HMI first (if existed). Otherwise, use settings below.]
3. For e-mail settings: a. Added system registers to record error codes reported should email delivery fails. LW-11444 LW-11445 failed step (e-mail) error code (e-mail) b. Added the option: [Use existing contact settings on HMI first (if existed). Otherwise, use settings below.]. c. Added a group box: [Error message]. When an error occurs in email delivery, the error message can be retrieved from the designated address. d. Added an option in Error Notification group box: [turn OFF LB-12053 or LB-12054 before sending an e-mail]. 4. For Macro Editor: a. Added support for import / export of macro commands. b. Added shortcut buttons to comment / uncomment multiple lines of codes. 5. Added support for import / export of recipe definition in Recipe Database. 6. Added options in Download window to delete existing user accounts, e-mail contacts or SMTP settings.
7. (ip/ie/xe/emt/mtv Series) Added support for the Watchdog function. Watchdog automatically reboots the system after the HMI stops functioning for a specified period of time. The related system registers are as follows: LB-9049 LW-11456 disable/enable watch dog watch dog timeout (5 ~ 300), unit : second 8. Added the following options in Picture View settings: a. [Automatically display the newly generated image.] b. [Send notification when switching to a new picture.] 9. The [Format] settings tab became available for Numeric objects with [Allow input] selected in General tab. Also the alignment setting for label is no longer limited to leading zero. 10. Added [Enable / Disable] group box in the Security tab of Recipe View object settings dialog box, allowing visibility and operation control 11. Added [Streaming over TCP] option in Video In (USB Camera) object settings dialog box. 12. Renamed Backup object to [Backup (Trigger-based)] object, and placed it under File Operation menu. 13. Added support for PLC address tags for the [Find/Replace] function.
14. Added the following new features for cmt Series models. a. Used [Backup (Trigger-based)] and [Backup (Global)] in place of a backup object. Object Name Backup (Trigger-based) Shortcut Icon Function On cmt-svr, backup is triggered by pressing this object on the screen. On cmt3151, backup is triggered either by pressing this object on the screen, or by bit address. Object Name Backup (Global) Shortcut Icon Function Backup runs in the background regardless of screens being viewed. b. Backup (Trigger-based) and Backup (Global) objects supports backup of Operation Logs. c. Added support for window transparency setting. This setting is applicable for popup windows, Direct / Indirect Windows, and keyboard windows. The settings dialog box and the effect are shown in the following screenshots.
d. Added support for [Customized file handling], which allows setting [Auto sync. periodically] and [Preservation limit], in Data Sampling. e. Added support for [Customized file handling], which allows setting [Auto sync. periodically] and [Preservation limit], in Event Log. f. Added [Enable / Disable] group box in the Security tab in Text / Comment settings. g. Added support for [Italic] and [Underline] in Label tab of object settings. h. Added support for [Circular] mode in Bar Graph settings. i. Added support for String Table. j. Added support for attaching window screenshots in the email sent as notification when an alarm occurs. k. Added [Right align] option for Date/Time object with [12-hour clock] selected. 15. Added the following new features for cmt3151. a. Added support for Pie Chart. b. Allowed the use of address types other than PLB or PLW_Bit for Set Bit objects with [Periodic Toggle] attribute. c. Allowed the use of address types other than PLW for Set Word objects with automatic attributes such as [Periodic set up], [Periodic set down], [Automatic JOG++], [Automatic JOG--], and [Periodic JOG++] etc.
Corrections EasyBuilder Pro 1. Fixed an issue where the decimal points are absent in the Event Log using %(WATCH)d.* syntax for Watch function. 2. (cmt Series) Fixed an issue where beep sound keeps playing after acknowledging all events using Function Key. 3. (cmt Series) Fixed an issue where the event text color changes when touched, even with acknowledge function disabled in Alarm Display / Event Display settings. 4. (cmt-svr) Discontinued support for OPC UA Server. Utility Manager 1. Fixed an issue where HMI cannot communicate with PLC when the project is downloaded to HMI using EasyAccess 2.0 [Project Transfer]. Drivers 1. Added CoDeSys V2 (symbolic addressing) (Ethernet) driver. 2. Added YASKAWA High Speed Server (Ethernet) driver. 3. Added GE FANUC VersaMax (Ethernet) driver. 4. Added Haiwell PLC (Ethernet) driver. 5. Added Artrich Inverter AR60i Series driver. 6. Added OMRON CP Series (USB) driver. 7. Added OPC UA Client driver. 8. Increased communication speed of CoDeSys V3 (Ethernet) driver. 9. Fixed an issue where writing with function code 15(Multi Coils Write) to the HMI which uses MODBUS Server driver and operates as MODBUS TCP/IP gateway yields erroneous result.
10. Fixed an issue where Panasonic MEWTOCOL7 driver cannot communicate using a non-zero station number. 11. Added [CPU slot no.] setting for GE Fanuc RX3i (Ethernet) driver. 12. OMRON EtherNet/IP (NJ/NX Series) driver: a. Fixed an issue where HMI cannot reconnect after it is unexpectedly shut down. b. Added support for nested structures. 13. Added support for time synchronization in IEC 60870-5-104 IEC 104 Server driver.