Modbus Server - M-Bus (EN ) Gateway for the integration of M-BUS meters with Modbus RTU and TCP based control systems.

Similar documents
IntesisBox Modbus Server - Honeywell XLS 80

Modbus Server SIEMENS Algorex (printer port)

IntesisBox BACnet IP Server - M-Bus

IntesisBox Modbus Server - BACnet/IP Client

IntesisBox Modbus Server - LON

Gateway for integration of Modbus RTU slave devices into BACnet IP based systems.

Modbus Server - Mitsubishi Electric G50

IntesisBox ASCII Server - KNX

Modbus Server - Mitsubishi Electric G50

ASCII Server - BACnet/IP Client. Gateway for integration of BACnet IP devices into ASCII enabled control systems.

IntesisBox Modbus Server Panasonic

IntesisBox KNX - AIRZONE

Modbus Server - Mitsubishi Electric G50

IntesisBox Modbus Server M-Bus

IntesisBox Modbus Server Fidelio IP

IntesisBox KNX - BACnet/IP Client

IntesisBox BACnet/IP Server M-Bus meters

IntesisBox Modbus Server Siemens Synova FC330A

IntesisBox BACnet/IP Server DALI

IntesisBox KNX - BACnet/IP Client

IntesisBox. KNX - Mitsubishi Electric G50. Gateway for integration of Mitsubishi Electric City Multi air conditioners into KNX control systems.

IntesisBox KNX SAMSUNG NASA Air Conditioners

IntesisBox Modbus Server KILSEN KSA-7xx. User s Manual 08/2013 r1.2 eng

IntesisBox KNX - Mitsubishi Electric G50

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

IntesisBox LON - KNX

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

IntesisBox Modbus Server LG Air Conditioning. User s Manual Issue Date: 06/2016 r1 eng

IBOX Modbus Server ESSER 8xxx/IQ8/FlexES fire panels

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

IntesisBox Modbus Server KNX

IntesisBox Modbus Server BACnet/IP Client


See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

IntesisBox KNX. Modbus RTU master. User's Manual v10 r11 eng

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

---- IntesisBox KNX Modbus RTU Master and Modbus TCP Client

IntesisBox BACnet/IP Server Modbus RTU Master

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT


IntesisBox ASCII Server KNX

Industrial 1-port RS422/485 Modbus Gateway IMG-110T

IntesisBox BACnet/IP Server Modbus TCP Master

IntesisBox. v.0.1. User Manual Issue Date: 12/2017 r1.3 EN

Industrial 2-port RS422/485 Modbus Gateway IMG-120T

Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision

IntesisBox PA-AC-MBS-1

USER MANUAL FOR GS100/GS1003G

IntesisBox PA-AW-MBS-1 v.2.0

IntesisBox Modbus Server BACnet MSTP and BACnet/IP client

TRAINING GUIDE LEVEL 3 MODBUS WRITE IMPORT COMMAND

PG AB Omron FINS to Modbus RTU Protocol Converter

3-7 Tiny Serial-to-Ethernet Device Server & Modbus Gateway

Any device, including routers and hosts, is running an implementation of IP address Host

Solenvis SL80 Pulse to M-Bus Converters

IntesisBox. Making Building Automation go further. BACnet Products

3-7 Tiny Serial-to-Ethernet Device Server & Modbus Gateway

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

Industrial 2-port RS422/485 Modbus Gateway

IntesisBox ME-AC-BAC-1

Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter

IntesisBox KNX. BACnet/IP Client. User's Manual v10 r10 eng

256 MB RAM. 256 MB 32 bits RISC Cortex-A8 600MHz SD Card Slot. N/A USB Host. N/A USB Client

Industrial 1-port RS422/485 Modbus Gateway

Products for DeviceNet

IntesisBox. v.2.5. User Manual Issue Date: 12/2017 r1.9 EN. Modbus RTU (EIA-485) Interface for Fujitsu air conditioners.

IntesisBox Modbus Server Mitsubishi Electric Centralized Controller TCP/IP XML. User Manual Issue Date: 01/2018 r1.0 EN

Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA. Features and Benefits. Certifications

NetBiter Serial Server User Manual

PG AB Notifier NFS 3030 to Modbus RTU Protocol Converter

Products for DeviceNet

ECLYPSE Communication Modules

IntesisBox. Making Building Automation go further. LON Products

Industrial Protocol Gateway

MODULAR CIRCUIT MONITORING SYSTEM

MID PRELIMINARY DATA SHEET. RI-D Series. Single Phase Multifunction Energy Meter (MID Certified) MID

IntesisBox KNX Modbus TCP master

MGate 4101-MB-PBS Series

CAS IKS Gateway (Modbus RTU/TCP and HTML) Manual

Operation Manual of EX9132CST-Series

User Manual. cmt-svr Startup Guide

Industrial Protocol Gateway

Version 1.0c May 6, 2010 ATK3

User Manual Protocol Converter PC-E, Serial to Ethernet (RS232/485 Modbus RTU to Modbus TCP/IP)

PG AC Modbus TCP to LonWorks Protocol Converter

ECLYPSE Communication Modules

USER MANUAL Z-KEY MODBUS ETHERNET SERIAL GATEWAY AND SERIAL DEVICE SERVER. Via Austria, PADOVA ITALY

EQ-DCM User Manual Revision 1.02 Sep 10, 2013

RTU560 Connections and Settings DIN Rail RTU 560CIG10

MXM-50. Modbus Interface for Mitsubishi Air-Conditioning. Installation and User Guide.

Mini Energy Web Server

AUTOMATION.CROUZET.COM 7 CROUZET TOUCH HMI AUTOMATION & CONTROL. New HMI. for & automation.crouzet.com

MGate 5111 Quick Installation Guide

INTRINSICALLY SAFE DUPLEXER PROTECTION. ELECTRONICS, INC Vulcan Road Apopka, Florida MOTOR INSTRUCTION MANUAL

PG AA Modbus RTU to SNMP Protocol Converter

BA00216R/09/EN/ MS Word

8-Port IP40 IEEE802.3af PoE Unmanaged Industrial Switch User s Manual

Transcription:

IntesisBox Server - M-Bus (EN 13757-3) Gateway for the integration of M-BUS meters with and based control systems. Integrate M-Bus meters into your master device or system (BMS, SCADA, PLC, HMI, TouchPanels ) Ethernet RS232/RS485 IntesisBox RS232 RS485 RS232 or RS485 to M-Bus level converter... Server LinkBoxMB Configuration Software Only needed for configuration Meters Read datapoints of M-bus meters from your master device or system (BMS, SCADA, PLC ). IntesisBox polls, continuously (configurable) or when ordered from the master, the M-bus meters to obtain the readings of their internal points. With every read, the new values received from the meters are updated in the IntesisBox memory, and become available to be read by the master device. From the master device you can force the poll of a concrete M-Bus meter, or force the poll of all M-Bus meters in any moment by simply writing in specific registers. IntesisBox requires an external M-Bus to RS232 or RS485 level converter to access the M-Bus meters. Apart of making the electrical level conversion, the external level converter also feeds the meters' M-Bus interface, due to this, there are different models of level converters and repeaters, depending on the number of M-Bus meters connected to the bus (i.e. 3, 20, 60, 120 or 250 meters). IntesisBox Server series are configured using LinkBoxMB, a software tool for windows TM which is supplied along with the purchase of IntesisBox with no additional cost. With the standard installation of LinkBoxMB, a Demo project for integration of M-Bus devices is also installed, using this demo project makes the engineering needed for this integration easy and quick, almost plug & play. 1 / 9

IntesisBox capacity Element Tiny version Basic version Extended version Number of M-Bus devices 10 60 500 Number of M-Bus signals 100 600 2000 Notes Number of M-Bus meters (connected to the bus) that can be read from IntesisBox. Number of M-Bus signals (readings in the meters) that can be read from IntesisBox. There are three different versions of IntesisBox Server - M-bus with different capacity every one of them: Basic version with capacity of 100 points and 10 M-Bus meters. Ref.: IBOX-MBS-MBUS-100 Basic version with capacity of 600 points and 60 M-Bus meters. Ref.: IBOX-MBS-MBUS-A Extended version with capacity of 2000 points and 500 M-Bus meters. Ref.: IBOX-MBS-MBUS-B 2 / 9

Sample applications Integration of any M-Bus meter into control systems ( or ). Ethernet RS232/RS485 IntesisBox RS232 RS485 RS232 or RS485 to M-Bus level converter... Server Meters control system Building Management Systems (BMS). SCADA packages. Human Machine Interfaces (HMI). Direct Digital Controllers (DDC). Programmable Logic Controllers (PLC). Typical M-Bus slave devices: Water meters. Heat meters. Energy meters. Electricity meters. General purpose pulse counters. MODBUS System monitoring / controlling Full monitoring and control System under monitoring 3 / 9

Typical applications The following is a diagram of a small/medium size installation (up to 60 meters): RS232 / RS485 to M-Bus level converter for up to 60 M-Bus meters RS232 or RS485 Ethernet... IntesisBox Up to 60 M-Bus meters * The following is a diagram of a large installation (up to 500 meters): Ethernet IntesisBox RS232 or RS485 Repeater for up to 250 M-Bus meters RS232 / RS485 to M-Bus level converter for up to 250 M-Bus meters...... Up to 250 M-Bus meters * Up to 250 M-Bus meters * * The maximum bus distance allowed by the converter or repeater will depend on the baud rate used, the section of the wires used, the number of M-Bus devices connected and the location of the devices inside the bus (all concentrated at the end of the bus, equally distributed along the bus, etc.). See the manual of converter and/or repeater for more details. 4 / 9

interface of IntesisBox Functions supported functions 03 and 04 (read holding registers and read input registers) can be used to read registers corresponding M-Bus meters readings. If poll records are used to read more than one register, it is necessary that the range of addresses requested contains valid addresses, if not, the corresponding error code will be returned. error codes are fully supported, they will be sent whenever a non valid action or address is required. functions 01 and 02 (read coils and read discrete inputs) can be used to read registers corresponding to digital datapoints, i.e. the virtual signals indicating communication error with the M-Bus meters. functions 05 and 15 (Write Single Coil and Write Multiple Coils) can be used to write registers corresponding to digital datapoints, i.e. special datapoints to force the poll of individual M-Bus meters or the poll to all meters. Baud rate can be selected from 1200, 2400, 4800, 9600, 19200, 38400 and 56700. Data Bits, Parity and Stop Bits can be also configured. slave number can be configured. Physical connection (RS232 or RS485) can also be selected. Only the lines RX, TX and GND of the RS232 port are used (TX/RX+ and TX/RX- for RS485). The port to use can be configured (by default 502 is used). The IP address, subnet mask and default router address to use by IntesisBox can be also configured. Address Map The address map is fully configurable. data coding formats supported For virtual signals, Data coding format by default is: 1 bit. Data coding format can be selected, for any analog point in the gateway, to be: 32 bit float (MB). 32 bit float (LSB..MSB). 5 / 9

M-Bus interface of IntesisBox The gateway connects to the M-Bus meters through an external RS232 or RS485 to M-Bus level converter. This external level converter is not included in the scope of delivery, and must be ordered separay or purchased directly by the customer. Apart of making the electrical level conversion, the converter must also feed the M-Bus, due to this, there are different models of level converters and repeaters, depending on the maximum number of M-Bus meters that can be connected to them (normally 3, 20, 60, 120 or 250 meters). These are the main features of the M-Bus interface of IntesisBox: RS232 (DB9 male connector, DTE) or RS485 two wires (plug-in terminal bloc with screws), which one to use is software configurable. Baud rate configurable from 300 to 9600 bps (the allowed baud rates in M-Bus are from 300 to 9600 bps, in general the devices are normally configured at 2400 bps at the factory). Primary and secondary addressing allowed. Useful timeouts and specific parameters to make the interface widely compatible with many meter's peculiarities found usually between different manufacturers. Polling of the meters can be continuously, either configured in the own IntesisBox or you can activate/deactivate continuous polling of the meters from side using a special datapoint. You can force a polling of the meters (refresh of readings) in any moment from side using special datapoints: one datapoint to force a polling of all the meters, and one specific datapoint per meter to force the polling of the individual meter. IntesisBox can also be configured to make a single polling of the meters (refresh of readings) at the start up. For each meter, a datapoint is available in indicating communication error with the meter, also a general communication error datapoint is available (that will be active whenever the communication with one or more meters has failed). Fully flexible configuration of the registers to poll in the meter, to adapt to any type of meter. M-Bus signal types supported IntesisBox can read the following type of signals offered by M-Bus meters: Energy (kwh or J). Volume (m3, feet3, gallon). Mass (kg). Power (kw or J/h). Volume flow (m3/h, m3/min or m3/s, gallon/h, gallon/min, gallon/s). Mass flow (kg/h). Flow Temperature ( C). Return Temperature ( C). Temperature difference (K). External Temperature ( C). Temperature limit ( C). Pressure (Bar). Volts (volts). Amps (amps). H.C.A., without units. (Multipurpose signal used, for example, by some energy meters to offer the readings of auxiliary pulse counter inputs of the device). On Time, normally in hours but depends on the meter. Operating Time, normally in hours but depends on the meter. Averaging Duration, normally in hours but depends on the meter. Actuality Duration, normally in hours but depends on the meter. And others. 6 / 9

Configuration tool LinkBoxMB Visual engineering tool, easy of use, for gateway s configuration and supervision compatible with Microsoft Windows operating systems, supplied with the gateway free of charge. Multi-window tool allowing to supervise simultaneously the communication activity with both protocols (systems), real time values for all the signals allowing to modify any value (very useful for test purposes), console window showing debug and working status messages, and configuration windows to configure all the gateway s parameters and signals. Signals configuration in plain text files (tab separated) for easy and quick configuration using Microsoft Excel (very useful in projects with a lot of points). Allows configuring the gateway s parameters and signals while in off-line (not connected to the gateway). Connection to the gateway for download the configuration and supervision by using serial COM port of the PC (serial cable supplied with the gateway). Allows configuring all the external protocols available for IntesisBox series. Upgrades for this software tool available free of charge whenever a new protocol is added to the IntesisBox series. Multi-project tool allowing having in the engineer s PC the configuration for all the sites with different IntesisBox series gateways. Multi-language tool, all the language-dependent strings are in a plain text file (tab separated) for easy modification or addition of new languages. A list of system commands is available to send to the gateway for debugging and adjust purposes (Reset, Date/time consultation/adjust, Firmware version request ). 7 / 9

Mechanical & Electrical characteristics Enclosure Plastic, type PC (UL 94 V-0). Dimensions: 107mm x 105mm x 58mm. Color Light Grey. RAL 7035. Power 9 to 30Vdc +/-10% 1.4W. 24Vac +/-10% 1.4VA. Power connector is a 2 poles plug-in terminal block. Mounting options Wall DIN rail EN60715 TH35 port 1 x Ethernet 10BT (RJ45). ports 1 x Serial RS232 (DB9 male DTE). 1 x Serial RS485 (Plug-in screw terminal block 2 poles). M-Bus ports 1 x Serial RS232 (DB9 male DTE). 1 x Serial RS485 (Plug-in screw terminal block 2 poles). Requires external RS232 or RS485 to M-Bus level converter to access the M-Bus LED indicators 1 x power. 2 x serial port activity (Tx, Rx). 2 x serial port M-Bus activity (Tx, Rx). 2 x Ethernet port (LNK, ACT). Console port RS232. (DB9 female DCE). Configuration Via console port. 1 Firmware Allows upgrades via console port. Operational 0 C to +70 C temperature range Operational humidity 5% to 95%, non condensing range Protection IP20 (IEC60529). RoHS conformity Compliant with RoHS directive (2002/95/CE). Certifications CE 1 Along with IntesisBox it is also supplied a standard DB9 male - DB9 female 1.8 m. cable for configuring and monitoring the device using a PC via serial COM port. The configuration software, compatible with MS Windows operating systems, is also supplied. 8 / 9

Dimensions Power + Ethernet port M-BUS ports 58 mm ports Console port 107 mm 105 mm Recommended available space for its installation into a cabinet (wall or DIN rail mounting), with space enough for external connections: 100 mm 115 mm 130 mm 9 / 9