Solid-state Timer H3YN

Similar documents
Solid-state Timer. Ordering Information. Miniature Timer with Multiple Time Ranges and Multiple Operating Modes H3YN- - Accessories (Order Separately)

Solid-state Timer. Ordering Information. Specifications. Miniature Timer Compatible with the MY Relay. Accessories. Time Ranges

Solid-state Timer. Ordering Information. Ultra-slim Timer for G2R Relay Socket. H3RN-jj. Accessories (Order Separately) Connecting Socket

Time-limit contact Time ranges Supply voltage Mounting s to 3 h 24, 100 to 120, 200 to 230 VAC (50/60 Hz); 12, 24, 48, 125, 100 to 110 VDC

Ex. H3Y-2-C 110 VAC 30 s Rated time Supply voltage 2. Sockets and Hold-down Clips are not included with the H3Y. They must be ordered separately.

Long-time range model (0.1 min to 10 h) 24 VAC; SPDT H3RN-1 H3RN-11 12, 24 VDC DPST-NO H3RN-2 H3RN-21

Solid-state Timer. Mounting system contact t contact. t Surface mounting/ track mounting

Conforms to VDE0435/2021 C/250, VDE0110, VDE0106/P100 Conforms to EN , pren

H3CR-H. Solid-state Power OFF-delay Timer. Ordering Information. DIN 48 x 48-mm Solid-state Power OFF-delay Timer

Model Number Structure

Solid-state timer Compact, Multi-function Timers for G2R Relay Socket. Model Number Structure. Ordering Information. Model Number Legend

Voltage Current Front-mounting bracket

Model Number Structure

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

Switching Power Supply

Appearance Size (mm) Power supply voltage Model (W H D) 100 to 240 VAC K3SC to 240 VAC

Model Number Structure

Functional configuration Rated input voltage Power ratings Output voltage Output current Part number Non-PFC

Switching Power Supply S82J. Ordering Information. Open-Frame, Covered-Frame, or Enclosed-Frame Type with Capacity Up to 600 W

Solid-state Timers H3DK

Model Number Structure

Solid-state Timers H3DK

DIN Track Mounted, Standard 22.5-mm Width Timer Range

Setting method Indication Control Output Model method mode Thermocouple (with sensor burnout detection circuit)

Solid-state Timer H3FA. Model Number Structure. DIP Model Timer for PC Board Use Provides Contact and Solid-state Output

Model Number Structure

Safety Relay Unit (I/O Unit Type)

ON-delay operation 8-pin round socket DPDT --- H3CA-8 H3CA-8 SPDT SPDT H3CA-8H H3CA-8H

Solid-state Counter. Power supply Output No voltage input (short/open circuit) Voltage input (high/low voltage) 30 cps 1 kcps 30 cps 1 kcps AC

S8VE (60/90/120/180/240-W Models)

4 mm. 8 mm. Proximity Sensor. Sensing head Sensing distance Output configuration Part Number M18 Shielded 4 mm DC 3-wire PNP-NO E2EZ-X4B1 M30

Conductive Level Controller

Model Number Structure

H3CR-F H3CR-F8 H3CR-F-300 H3CR-F8-300

Time-limit operation/ self-resetting DPDT --- H3M H3M with Y92F-40 adapter SPDT SPDT H3M-H H3M-H with Y92F-40 adapter

SPST-NO SPDT DPST-NO DPDT

Switching Power Supply

Model Number Structure

Model Number Structure

Model Number Structure

Main contacts Auxiliary contact Number of input channels Rated voltage Model Category 24 VAC/VDC 3PST-NO SPST-NC 1 channel or 2 channels possible

Switch Mode Power Supply

Three-phase Phase-sequence Phase-loss Relay

Model Number Structure

Short-time range model (0.1 s to 10 min) DPDT H3YN-2 H3YN-21 4PDT H3YN-4 *1 H3YN-41 *1. DIN track mounting. Solder terminal. DIN track mounting

Common to all H3CR. Basic Setting. Setting of Selectors. Selection of Operating Mode. Selection of Time Unit and Time Range. Common to all H3CR 1

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations

Thread length (overall length) material

Single-phase Voltage Relay

Solid-State Counter/Timer

H3CA-8H-AC/100/110/120

I/O delay. (0.32 in ±0.06 in)

ON-delay operation 8-pin round socket DPDT --- H3CA-8 H3CA-8 SPDT SPDT H3CA-8H H3CA-8H

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1

Inductive Proximity Sensor

SRT2-ROC08, SRT2-ROC16

Switching Power Supply S8E1. Ordering Information. Compact and Economical Switching Power Supply

Model Number Structure

Model Number Structure

Note: Each relay to be mounted must incorporate a coil that has proper specifications within the maximum rated voltage range.

Model Number Structure

D2D. Door Interlock Switch. Ordering Information. Power Switch with Minimum Contact Gap of 3 mm. Model Number Legend.

Three-phase Asymmetry and Phase-sequence Phase-loss Relay K8AB-PA

DPST-NO None 2 channels Auto-reset Inverse (+/-) 24 VAC/VDC 4 G9SB-2002-A 1 channel or 2

Solid State Relays with Failure Detection Function

Monitoring Relays can be used to monitor 3-phase power supplies with 3 or 4 wires simply by changing DIP switch settings.

Inductive Proximity Sensor

G9SA. Ordering Information. Safety Relay Unit. The G9SA Series Offers a Complete Line of Compact Units. H Several types of 45-mm wide Units are

Model Number Structure

Cylindrical Proximity Sensor

Common to all H3DS. Installation of Screw-Less Clamp Models. Tools. Applicable Wires. Applicable Screwdriver. Applicable Wire Sizes

Classification Enclosure rating Input voltage Type of

A16. Separate Construction with Cylindrical 16-dia. Body. Pushbutton Switch (Detachable) (Lighted/Non-Lighted) (Cylindrical 16-dia.

(Applicable output load) to 264 (see note 2) (see note 1) (2Aat75to264VAC) G3R-202SLN-US PCB Yes 2 A at 100 to 120 VDC. (2 A at 75 to 132 VDC)

Mini Photoelectric Sensor

Switch Mode Power Supply S8VT 120/240/480/960 W Models

Model Number Structure. Ordering Information. Switch Mode Power Supply S82K (3/7.5/15/30/50/90/100-W Models) Model Number Legend.

S82S (3/7.5-W Models)

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

16 g SS-01GL-FD SS-01GL-F SS-01GL-FT 50 g SS-01GLD SS-01GLD1 SS-01GLD2 SS-01GL SS-01GLT Simulated roller lever

Model Number Structure

E4PA. Ultrasonic Displacement Sensor. Ordering Information

3. Input KJ: Thermocouple P: Platinum resistance thermometer T: Thermocouple/platinum resistance thermometer (universal-input)

G3F/G3FD. Model Number Structure. Solid State Relays Model Number Legend

7. Approved Standards US: UL, CSA UL: FILE No.E CSA: FILE No.LR31928) 8. Special Function None : Standard U : For ultrasonically cleanable

Special-purpose Basic Switch

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

D2VW. Sealed Miniature Basic Switch. Ordering Information Model Number Legend D2VW- -

G3NE. Model Number Structure. Solid State Relays. Model Number Legend. Compact, Low-cost, SSR Switching 5 to 20 A

Ordering Information. Three-phase Input Switch Mode Power Supply S8VT S8VT. Model Number Legend

Self-powered Totalizer New H7E

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

Self-Powered Counters H7EC

NPN output PNP output Cord connection Cord length: 2 m Through-beam 7 m Light-ON. 2 m. (selectable by wiring) Diffuse reflective 0.

Transistor drive 2c/4c 5A slim power relays

Three-phase Phase-sequence Phase-loss Relay

D2D. Door Interlock Switch. Ordering Information. Power Switch with Minimum Contact Gap of 3 mm. Model Number Legend.

E4PA-N. Application Examples. Features. Ultrasonic Displacement Sensor. Now, more advanced with a new mutual interference prevention function.

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

Transcription:

Solid-state Timer H3YN Miniature Timer with Multiple Time Ranges and Multiple Operating Modes Minimizes stock. Pin configuration compatible with MY Power Relay. Standard multiple operating modes and multiple time ranges. Conforms to EN61812-1 and IEC60664-1 for Low Voltage, and EMC Directives. Model Number Structure Model Number Legend H3YN-@@-@ 1 2 3 1. Output 2: DPDT 4: 4PDT 2. Time Range None:Short-time range (0.1 s to 10 min) 1: Long-time range (0.1 min to 10 hrs) 3. Contact Type None:Single contact Z: Twin contacts Ordering Information List of Models Supply voltage Time-limit contact Short-time range model (0.1 s to 10 min) Long-time range model (0.1 min to 10 h) 24, 100 to 120, 200 to 230 VAC; DPDT H3YN-2 H3YN-21 12, 24, 48, 100 to 110, 125 VDC 4PDT H3YN-4 H3YN-41 24 VDC 4PDT (Twin contacts) H3YN-4-Z H3YN-41-Z Note: Specify both the model number and supply voltage when ordering. Example: H3YN-2 24 VAC Accessories (Order Separately) Connecting Socket Supply voltage H3YN-2/-21 Timer H3YN-4/-41 H3YN-4-Z/-41-Z Track mounting/front Connecting Socket PYF08A, PYF08A-N, PYF08A-E PYF14A, PYF14A-N, PYF14A-E Back Connecting Socket Solder terminal Wire-wrap terminal PC terminal PY08 PY08QN(2) PY08-02 PY14 PY14QN(2) PY14-02 Solid-state Timer H3YN 1

Hold-down Clips Y92H-3 Y92H-4 Model Applicable Socket PYF08A, PYF08A-N, PYF08A-E PYF14A, PYF14A-N, PYF14A-E PY08, PY08QN(2), PY08-02 PY14, PY14QN(2), PY14-02 Specifications Ratings Time ranges Rated supply voltage Pin type Operating mode Operating voltage range Item H3YN-2/-4/-4-Z H3YN-21/-41/-41-Z 0.1 s to 10 min (1 s, 10 s, 1 min, or 10 min max. selectable) 24, 100 to 120, 200 to 230 VAC (50/60 Hz) 12, 24, 48, 100 to 110, 125 VDC (see note 1) Plug-in 0.1 min to 10 h (1 min, 10 min, 1 h, or 10 h max. selectable) ON-delay, interval, flicker OFF start, or flicker ON start (selectable with DIP switch) 85% to 110% of rated supply voltage (12 VDC: 90% to 110% of rated supply voltage) (see note 2) Reset voltage 10% min. of rated supply voltage (see note 3) Power consumption 100 to 120 VAC: Relay ON: approx. 1.8 VA (1.6 W) at 120 VAC, 60 Hz Relay OFF: approx. 1 VA (0.6 W) at 120 VAC, 60 Hz 200 to 230 VAC: Relay ON: approx. 2.2 VA (1.8 W) at 230 VAC, 60 Hz Relay OFF: approx. 1.5 VA (1.1 W) at 230 VAC, 60 Hz 24 VAC: Relay ON: approx. 1.8 VA (1.4 W) at 24 VAC, 60 Hz Relay OFF: approx. 0.3 VA (0.2 W) at 24 VAC, 60 Hz 12 VDC: Relay ON: approx. 1.1 W at 12 VDC Relay OFF: approx. 0.1 W at 12 VDC 24 VDC: Relay ON: approx. 1.1 W at 24 VDC Relay OFF: approx. 0.1 W at 24 VDC 48 VDC: Relay ON: approx. 1.2 W at 48 VDC Relay OFF: approx. 0.3 W at 48 VDC 100 to 110 VDC: Relay ON: approx. 1.6 W at 110 VDC Relay OFF: approx. 0.4 W at 110 VDC 125 VDC: Relay ON: approx. 1.6 W at 125 VDC Relay OFF: approx. 0.4 W at 125 VDC Control outputs DPDT: 5 A at 250 VAC, resistive load (cosφ = 1) 4PDT: 3 A at 250 VAC, resistive load (cosφ = 1) Note: 1. Single-phase, full-wave-rectified power supplies can be used. 2. When using the H3YN continuously in any place where the ambient temperature is in a range of 45 C to 50 C, supply 90% to 110% of the rated supply voltages (supply 95% to 110% with 12 VDC type). 3. Set the reset voltage as follows to ensure proper resetting. 100 to 120 VAC: 10 VAC max. 200 to 230 VAC: 20 VAC max. 100 to 110 VDC: 10 VDC max. 2 Solid-state Timer H3YN

Characteristics Item Accuracy of operating time Setting error Reset time Influence of voltage Influence of temperature Insulation resistance Dielectric strength Note: 1. Terminal screw sections are excluded. 2. Refer to the Life-test Curve. H3YN-2/-21/-4/-41 ±1% FS max. (1 s range: ±1%±10 ms max.) ±10%±50 ms FS max. Min. power-opening time: 0.1 s max. (including halfway reset) ±2% FS max. ±2% FS max. 100 MΩ min. (at 500 VDC) 2,000 VAC, 50/60 Hz for 1 min (between current-carrying terminals and exposed non-current-carrying metal parts) (see note 1) 2,000 VAC, 50/60 Hz for 1 min (between operating power circuit and control output) 2,000 VAC, 50/60 Hz for 1 min (between different pole contacts; 2-pole model) 1,500 VAC, 50/60 Hz for 1 min (between different pole contacts; 4-pole model) 1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts) Vibration resistance Destruction: 10 to 55 Hz, 0.75-mm single amplitude for 1 h each in 3 directions Malfunction: 10 to 55 Hz, 0.5-mm single amplitude for 10 min each in 3 directions Shock resistance Destruction: 1,000 m/s 2 Malfunction: 100 m/s 2 Ambient temperature Operating: 10 C to 50 C (with no icing) Storage: 25 C to 65 C (with no icing) Ambient humidity Operating: 35% to 85% Life expectancy Impulse withstand voltage Noise immunity Static immunity Mechanical: 10,000,000 operations min. (under no load at 1,800 operations/h) Electrical: DPDT: 500,000 operations min. (5 A at 250 VAC, resistive load at 1,800 operations/h) 4PDT: 200,000 operations min. (H3YN-4-Z/-41-Z: 100,000 operations min.) (3 A at 250 VAC, resistive load at 1,800 operations/h) (see note 2) Between power terminals: 3 kv for 100 to 120 VAC, 200 to 230 VAC, 100 to 110 VDC, 125 VDC 1 kv for 12 VDC, 24 VDC, 48 VDC, 24 VAC Between exposed non-current-carrying metal parts: 4.5 kv for 100 to 120 VAC, 200 to 230 VAC, 100 to 110 VDC, 125 VDC 1.5 kv for 12 VDC, 24 VDC, 48 VDC, 24 VAC ±1.5 kv, square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) Destruction: 8 kv Malfunction: 4 kv Degree of protection IP40 Weight Approx. 50 g EMC (EMI) EN61812-1 Emission Enclosure: EN55011 Group 1 class A Emission AC Mains: EN55011 Group 1 class A (EMS) EN61812-1 Immunity ESD: EN61000-4-2: 8 kv air discharge (level 3) Immunity RF-interference from AM Radio Waves: EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3) Immunity Burst: EN61000-4-4: 2 kv power-line (level 3) 2 kv I/O signal-line (level 4) Immunity Surge: EN61000-4-5: 2 kv line to ground (level 3) 1 kv line to line (level 3) Approved standards UL508, CSA C22.2 No. 14, Lloyds Conforms to EN61812-1 and IEC60664-1. (2.5 kv/2 for H3YN-2/-21, 2.5 kv/1 for H3YN-4/-41, H3YN- 4-Z/-41-Z) Output category according to EN60947-5-1. Solid-state Timer H3YN 3

Life-test Curve (Reference Value) H3YN-2/-21 Switching operations (x 10 3 ) 5,000 1,000 500 200 250 VAC, cosφ = 1 24 VDC, cosφ = 1 Switching operations (x 10 3 ) 5,000 1,000 500 200 250 VAC, cosφ = 0.4 24 VDC, L/R = 7 ms Load current (A) Load current (A) Reference: A maximum current of 0.6 A can be switched at 125 VDC (cosφ = 1). Maximum current of 0.2 A can be switched if L/R is 7 ms. In both cases, a life of 100,000 operations can be expected. The minimum applicable load is 1 ma at 5 VDC (P reference value). H3YN-4/-41 Switching operations (x 10 3 ) 5,000 1,000 500 200 250 VAC, cosφ = 1 24 VDC, cosφ = 1 Switching operations (x 10 3 ) 5,000 1,000 500 200 250 VAC, cosφ = 0.4 24 VDC, L/R = 7 ms Load current (A) Load current (A) H3YN-4-Z/-41-Z Reference: A maximum current of 0.5 A can be switched at 125 VDC (cosφ = 1). Maximum current of 0.2 A can be switched if L/R is 7 ms. In both cases, a life of 100,000 operations can be expected. The minimum applicable load is 1 ma at 1 VDC (P reference value). Switching operations (x 10 3 ) 5,000 1,000 500 100 60 24 VDC, resistive load 250 VAC, resistive load Load current (A) Reference: A maximum current of 0.5 A can be switched at 125 VDC (cosφ = 1). Maximum current of 0.2 A can be switched if L/R is 7 ms. In both cases, a life of 100,000 operations can be expected. The minimum applicable load is 0.1 ma at 1 VDC (P reference value). 4 Solid-state Timer H3YN

Connections Connection H3YN-2/-21 DIN Indication H3YN-4/-41 H3YN-4-Z/-41-Z DIN Indication Timer circuit Timer circuit UP PW UP PW Pulse Operation A pulse output for a certain period can be obtained with a random external input signal. Use the H3YN in interval mode as shown in the following timing charts. H3YN-2/-21 Power (9-14) H3YN-4/-41 H3YN-4-Z/-41-Z Timer circuit External input External short circuit (5-13) External input (9-13) NO (12-8) NC (12-4) 50 ms min. Note: t: Set time Rt: Reset time Timer circuit External input!caution Be careful when connecting wires. Power (9-14) External short circuit (5-13) External input (9-13) NO (10-6, 11-7, 12-8) NC (10-2, 11-3, 12-4) 50 ms min. Note: t: Set time Rt: Reset time Mode Pulse operation Power supply between 9 and 14 Short-circuit between 5 and 13 Input signal between 9 and 13 Operating mode; interval and all other modes Power supply between 13 and 14 Terminals Solid-state Timer H3YN 5

Operation Timing Chart Operating mode H3YN-2/-21 Timing chart H3YN-4/-41 ON-delay Power Output Interval Power Output Flicker OFF-start Power Output Flicker ON-start Power Output Note: t: Set time Rt: Reset time NC (9-1, 12-4) NO (9-5, 12-8) NC (9-1, 12-4) NO (9-5, 12-8) NC (9-1, 12-4) NO (9-5, 12-8) NC (9-1, 12-4) NO (9-5, 12-8) NC (9-1, 10-2, 11-3, 12-4) NO (9-5, 10-6, 11-7, 12-8) NC (9-1, 10-2, 11-3, 12-4) NO (9-5, 10-6, 11-7, 12-8) NC (9-1, 10-2, 11-3, 12-4) NO (9-5, 10-6, 11-7, 12-8) NC (9-1, 10-2, 11-3, 12-4) NO (9-5, 10-6, 11-7, 12-8) 6 Solid-state Timer H3YN

DIP Switch Settings The 1-s range and ON-delay mode for H3YN-2/-4/-4-Z, the 1-min range and ON-delay mode for H3YN-21/-41/-41-Z are factory-set before shipping. Time Ranges Model Time range Time setting Setting Factory-set range H3YN-2, 1 s 0.1 to 1 s Yes H3YN-4 H3YN-4-Z 10 s 1 to 10 s No 1 min 0.1 to 1 min No 10 min 1 to 10 min No H3YN-21, H3YN-41 H3YN-41-Z 1 min 0.1 to 1 min Yes 10 min 1 to 10 min No 1 s 10 s 1 min 10 min 1 h 0.1 to 1 h No 10 h 1 to 10 h No Note: The top two DIP switch pins are used to select the time ranges. Operating Modes ON-delay Interval Flicker OFF-start Flicker ON-start Operating mode Setting Factory-set Yes No No No Note: The bottom two DIP switch pins are used to select the operating mode. Nomenclature Output Indicator (Orange) (Lit: Output ON) Run/Power Indicator (Green) (Lit: Power ON) Main Dial Set the desired time according to time range selectable by DIP switch. Solid-state Timer H3YN 7

Dimensions Note: All units are in millimeters unless otherwise indicated. Timers H3YN-2/-21 Front Mounting Eight, 3 1.2 elliptic holes 28 max. (63.0) 6.4 21.5 max. H3YN-4/-41 Front Mounting H3YN-4-Z/-41-Z Fourteen, 3 1.2 elliptic holes 28 max. 21.5 max. Mounting Height PYF08A/PYF08A-N/PYF08A-E (PYF14A/PYF14A-N/PYF14A-E (see note)) PY08 (PY14 (see note)) PY08QN (PY14QN (see note)) H3YN Series H3YN Series H3YN Series PYF08A (PYF14A) PY08 (PY14) PY08QN (PY14QN) Note: Models in parentheses are Connecting Sockets to the H3YN-4/-41 or H3YN-4-Z/-41-Z. 8 Solid-state Timer H3YN

Accessories (Order Separately) Connecting Sockets Use the PYF@A, PY@, PY@-02, or PY@QN(2) to mount the H3YN. When ordering any one of these Sockets, replace @ with 08 or 14. Track Mounting/Front Connecting Sockets PYF08A Two, 4.2 5 mounting holes 6 3.4 Terminal Arrangement Mounting Holes Eight, M3 (Top View) 8 sems Two, 4.5 dia. M4 or M3 72 max. 35.4 59±0.3 H3YN Series 90.5 86.6 23 max. 16.5 6 4 15±0.2 PYF@A PYF-14A 30 max. Two, 4.2 5 mounting holes 6 Fourteen, M3 8 sems 3.4 Terminal Arrangement (Top View) Mounting Holes Two, 4.5 dia. M4 or M3 72 max. 35.4 59±0.3 4 29.5 max. 16.5 6 22±0.2 30 max. PYF-08A-N Terminal Arrangement Mounting Holes (for Surface Mounting) 4 42 8 44 1 12 5 14 42 12 4 1 44 14 8 5 66.5 max. 19.8 3.2 dia. 3.6 dia. PYF-14A-N PYF-08A-N 41 11 12 9 A2 A2 A1 14 14 13 22 max. 4 3 2 1 42 32 22 12 8 7 6 5 44 34 24 14 30 max. 12 9 41 11 14 14 13 A2 A2 A1 Terminal Arrangement 42 32 22 12 4 3 2 1 44 34 24 14 8 7 6 5 Mounting Holes (for Surface Mounting) Two, 3.5 dia. 66.5 max. PYF-14A-N 41 31 21 11 12 11 10 9 A2 A2 A1 14 14 13 29.5 max. 30 max. 12 11 10 9 41 31 21 11 14 14 13 A2 A2 A1 20.8 Solid-state Timer H3YN 9

PYF08A-E Two, 4.2 5 mounting holes Eight, M3 8 sems (Top View) Two, 4.5 dia. M4 or M3 72 max. 23 max. 31 max. PYF14A-E Two, 4.2 5 mounting holes Fourteen, M3 8 sems (Top View) Two, 4.5 dia. M4 or M3 72 max. 29.5 max. Back Connecting Sockets PY08, PY14 31 max. Eight, 3 1.2 dia. holes only for PY08 (Fourteen, 3 1.2 dia. holes) 24 max. Terminal Arrangement (Bottom View) Panel Cutout 21.4 +0.2 0 0.3 25.5 29.5 max. max. 25.8 +0.2 0 59.3 H3YN Series 2.7 7.7 2.6 2.7 20 max. PY08QN, PY14QN PY08QN(2), PY14QN(2) 25 max. * (See note) 24 max. 22 max. PY08 PY14 Terminal Arrangement (Bottom View) PY@, PY@-02, PY@QN(2) ** 41.5 max. (see note) 1 x 1 29.5 max. Note: With PY@QN(2)(-3), dimension * should read 20 max. and dimension ** 36.5 max. PY08QN PY08QN(2) PY14QN PY14QN(2) PY08-02, PY14-02 22 max. Terminal Arrangement (Bottom View) 0.3 25.5 29.5 max. max. 2.7 4.3 2 16.5 max. PY08@-02 PY14@-02 10 Solid-state Timer H3YN

Flush Mounting Adapter Y92F-78 R0.5 max. Panel Cutout 25.2 +0.2 0 5 31.6 +0.2 0 27.1 3 48.5 25.1 3 33.5 31.5 Panel thickness 1 to 3 mm Socket Mounting Plates Note: 1. Push the H3Y in until the Adaptor (Y92F- 78) hooks engage with its rear panel. 2. Do not round the corners of the cutout on the rear panel surface, otherwise the Adaptor (Y92F-78) tabs may not engage properly. The PYP-1 is a Socket Mounting Plate for a single Socket and the PYP-18 is a Socket Mounting Plate for 18 Sockets. The PYP-18 can be cut appropriately according to the number of Sockets to be used. PYP-1 Two, 3.4-dia. holes 49 PYP-18 492 17 x 27.4 = 465.8±0.6 27.4±0.15 21.6 4.5 3.4 13.1 28 t = 1.6 Square hole 42±0.1 49 72, elliptic holes t = 1.6 Hold-down Clips The Hold-down Clip makes it possible to mount the H3YN securely and prevent the H3YN from falling out due to vibration or shock. Y92H-3 Y92H-4 Y92H-3 for PYF@A Socket (Set of Two Clips) 5 max. Y92H-4 for PY@ Socket 9R 53 30.5 24.5 2.5 20 (84 ) 4.5 1.2 4.5 33.7 Solid-state Timer H3YN 11

Precautions Correct Use The operating voltage will increase when using the H3YN continuously in any place where the ambient temperature is in a range of 45 C to 50 C. Supply 90% to 110% of the rated voltages (at 12 VDC: 95% to 110%). Do not leave the H3YN in time-up condition for a long period of time (for example, more than one month in any place where the ambient temperature is high), otherwise the internal parts (aluminum electrolytic capacitor) may become damaged. Therefore, the use of the H3YN with a relay as shown in the following circuit diagram is recommended to extend the service life of the H3YN. T X2/b T/a X1/a X1/a The H3YN must be disconnected from the Socket when setting the DIP switch, otherwise the user may touch a terminal imposed with a high voltage and get an electric shock. Do not connect the H3YN as shown in the following circuit diagram on the right hand side, otherwise the H3YN s internal contacts different from each other in polarity may become short-circuited. Correct X1 Use the following safety circuit when building a self-holding or selfresetting circuit with the H3YN and an auxiliary relay, such as an MY Relay, in combination. In the case of the above circuit, the H3YN will be in pulse operation. Therefore, if the circuit shown on page 5 is used, no auxiliary relay will be required. Do not set to the minimum setting in the flicker modes, otherwise the contact may become damaged. X2 X : Auxiliary relay such as MY Relay Incorrect : Auxiliary relay such as MY Relay Be careful not to apply any voltage to the terminal screws on the back of the Timer. Mount the product so that the screws will not come in contact with the panel or metal parts. Do not use the H3YN in places where there is excessive dust, corrosive gas, or direct sunlight. Do not mount more than one H3YN closely together, otherwise the internal parts may become damaged. Make sure that there is a space of 5 mm or more between any H3YN models next to each other to allow heat radiation. The internal parts may become damaged if a supply voltage other than the rated ones is imposed on the H3YN. In order to conform to UL and CSA requirements when using the H3YN-4/-41 or H3YN-4-Z/-41-Z, connect the Unit so that output contacts (contacts of different poles) have the same electric potential. In cases such as PLC input where the load is extremely small for the control output of a timer containing a power relay (using other than gold-plated contacts), reliability can be increased by using contacts of the same poles (e.g., the H3Y-2) in parallel. Precautions for EN61812-1 Conformance The H3YN as a built-in timer conforms to EN61812-1 provided that the following conditions are satisfied. Handling Do not touch the DIP switch while power is supplied to the H3YN. Before dismounting the H3YN from the Socket, make sure that no voltage is imposed on any terminal of the H3YN. The applicable Socket is the PYF@A. Only basic insulation is ensured between the Y92H-3 Hold-down Clips and H3YN internal circuits. Do not allow the Y92H-3 Hold-down Clips to contact other parts. The insulation test voltage between different pole contacts for the 4- pole model is the impulse voltage of 2.95 kv. Wiring The power supply for the H3YN must be protected with equipment such as a breaker approved by VDE. Basic insulation is ensured between the H3YN s operating circuit and control output. Basic insulation: Overvoltage category II, pollution degree 1 (H3YN-4/-41, H3YN-4-Z/- 41-Z), pollution degree 2 (H3YN-2/-21) (with a clearance of 1.5 mm and a creepage distance of 2.5 mm at 240 VAC) ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. L089-E1-03 OMRON Corporation Industrial Automation Company In the interest of product improvement, specifications are subject to change without notice. Industrial Control Components Division Shiokoji Horikawa, Shimogyo-ku, Kyoto, 600-8530 Japan Tel: (81)75-344-7119/Fax: (81)75-344-7149 Printed in Japan 0802-0.6M (0296) 12