USER MANUAL. Batteries to Power Your World!

Similar documents
Toughbook. CF-C1 MK1 refurbished. Table of Contents:

BW 2050 Manual. Weltech Interna onal Limited INTRODUCTION

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN

IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

DO NOT LOSE THIS SHEET - YOUR FACTORY MASTER CODE IS UNIQUE TO YOUR KEYPAD

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA. GE Critical Power

USER MANUAL SES-FA4UB

Back-UPS RS 550 Installation & Operation

HuddlePod Air DUO Dual Wireless Audio Pods Installation and Operation Manual

OPERATING INSTRUCTIONS POWERSMART 10 10,000 MAH PORTABLE POWER PLEASE READ BEFORE OPERATING THIS EQUIPMENT

Installation and Operation Back-UPS Pro 900

Q. How do I start using Mānoa Guardian? A. Go to the App Store or Google Play on your mobile device and download the app. Search for Rave Guardian.

Powerware 3105 UPS User s manual

ADDITIONAL INSTALLATION TIPS CAN BE FOUND AT:

Owner's Manual. For latest instructions please go to

User Manual Back-UPS BE650MC

P OCKET POWER 9000 T. Powerful Universal Portable Charger PLEASE READ BEFORE OPERATING THIS EQUIPMENT

Installation and Operation Back-UPS Pro BR700G-TW

6 RUGGED WINDOWS TABLET CONKER NS6

Tx Link. Quick Setup Guide. English. Connection module

P OCKET POWER 6000 T. Powerful Universal Portable Charger PLEASE READ BEFORE OPERATING THIS EQUIPMENT

Powerware 3105 UPS User s manual

ZipCharge. User Guide. Ultra fast-charging portable power stick. Revision 1.04

Installation and Operation Back-UPS Pro 900

POWERGORILLA POWERGORILLA TACTICAL 5V TO 24V RUGGED HIGH TECH CHARGER USER GUIDE

STYLISH LED DESK LAMP WITH DIFFERENT LIGHT MODES

Kinetic Switch APP User Manual

Line Interactive 1000VA/1400VA/2000VA Uninterruptible Power System

Ultra PLUS. Guide For A Great User Experience:

8 RUGGED ANDROID TABLET CONKER ST80

COMPACT LED DESK LAMP WITH LCD DISPLAY

MINI-G RUGGED HIGH TECH 5V TO 19V CHARGER USER GUIDE

USER MANUAL CAMPLEX FIBERGIG 2-Channel 3G-HD/SDI Video & GigaBit Ethernet Fiber Optic Transport

W IRELESS8000 T. Powerful Universal Portable Charger PLEASE READ BEFORE OPERATING THIS EQUIPMENT

EDTracker Pro Wired. User Guide

PLEASE READ BEFORE OPERATING THIS EQUIPMENT.

Table of Contents. 1.Introduction... P.2. 2.Product Tour... P Operating Instructions... P Important Notes... P.10

300Mpbs Wireless Range Extender

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

Car Video Recorder. RoadRunner 535W. User Manual

PORTABLE WIRELESS PA SYSTEM WITH LITHIUM -ION RECHARGEABLE BATTERY AWP6042 OWNER S MANUAL. Handheld Microphone Headset Transmitter

5 RUGGED ANDROID BARCODE SCANNER CONKER SX5

Installation and Operation Manual Back-UPS BR900G-RS

Teslights Hybrid Lighting Controls B-PLC Solution

MOBILE CONNECTOR - GEN 2 OWNER'S MANUAL

OWNER'S MANUAL. Model:PSV Amp SWITCHING DC POWER SUPPLY.

UNIVERSAL. Energy Saver Windows PC Stick with IPTV add-on USER GUIDE

Harbortronics Time-Lapse Package Troubleshooting Guide This document is intended to help diagnose any problems with your Time-Lapse Package.

Digital Proximity System Opera on and Maintenance Manual

8 RUGGED WINDOWS TABLET CONKER NS8

Operating Instructions

12 RUGGED WINDOWS TABLET CONKER NS12

OFFICE UPS MULTI-DEVICE PROTECTION UPS 500S/600S/750S

REGION: NORTH AMERICA

SOLAR. User manual of high security level electronic lock. Gebaude Sicherheitstechnik Vertriebs GmbH, Kassel

HuddlePod Air Big Audio

E8431 First Edition Model: T00CP

Remote Ticket Entry. System/User Requirements

SHINE 3000 WITH FASHION CABLE

POCKET BLUETOOTH SPEAKER WITH POWER CHARGER

6 Outlet Energy Saving Power Board

Operating Instructions

DS-1H05 Ethernet-over-Coax Extender. User Manual

Riso Comcolor Series

Set Up Your Print. Overview. The main interface has five components: 1. 3D Viewer

CONTENT COMPONENTS OF PROJECTOR... 2 SPECIFICATION... 3 INSTRUCTION MANUAL... 3 CHARGING THE PROJECTOR... 3 SET UP... 4

BlueSet Wireless Headset Interface User Guide

EATON 5S 850/1200/1600

Wireless Noise-Cancelling Over-ear Headphones. Instruction Manual GTCBTNC16

Skyrider Blue Kids Headphones

Chapter 5 Review. Power Supplies

High contrast 3.25 backlit mono LCD screen Screen resolu on 128x64 pixels Screen LCD brightness of 250 lumens for easy viewing in direct sunlight

RENU-IT DELUXE DIRECTIONS FOR USE

PowerPal Selectable Voltage 3-Amp Breadboard Power Supply (#32133)

Lenovo S60-a. Quick Start Guide. Read this guide carefully before using your smartphone.

Innovative K5 Palm Size LED Projector.

THE BULLET. Bluetooth Speaker with NFC Technology. Instruction Manual

Multi-touch Touch-Screen. Installation Guide

EO-BG930. User Manual. English (EU). 07/2016. Rev.1.0.

Do not attempt to service the unit yourself. Seek assistance from a qualified professional.

user s manual Battery case model #: IPB3500S Battery Case Charger for iphone 6

Bluetooth Hands-Free Speaker Phone Custom Accessories 23685

LQBHPS Bluetooth Headphones User Manual Please read this manual before operating your device, and keep it for future reference.

s e May 2016 Version

WORKSWELL WIRIS PRO QUICK START GUIDE. FW Version: Release date: 22 nd March, Revision : 1.2 EN

Always there to help you. Register your product and get support at BT5580 BT5880. Question? Contact Philips.

Pure sine wave inverter. Product Manual

Monitor / 1501 User Manual

Series F75 Fail-Safe Module Installation, Operation and Maintenance Instructions

PowerPlant Tuner tuner pedal with power distribution. user manual

AC 3000 Digital Camera AC/DC Power Adapter

Nova-Pro 100 TABLE OF CONTENTS: Safeguards and Precautions

Dolphin TM 6110 Mobile Computer. Quick Start Guide

Power. Document Part Number: This guide explains how the computer uses power. March 2006

Always there to help you. Register your product and get support at DS3480. Question? Contact Philips.

Tele-ECG. Accurate, Connected, Easy. USER MANUAL. Sanjee. Proudly Made In India. ElectroMedicals

CRASHER BLUETOOTH WIRELESS STEREO SPEAKER INSTRUCTION MANUAL

Model HM-535 Power Supply Installation and Service Instructions

Smart Grid Tie Microinverter User Manual

PhoneSaver USER MANUAL. Never lose a call! Never miss a message!

Transcription:

USER MANUAL Batteries to Power Your World!

Table of Contents Please read this manual carefully before using the Freedom CPAP Ba ery for the first me and observe all safety warnings. Package Contents... 1 Connec on Components Sold Separately... 1 Product Specifica ons... 2 Safety Features... 2 Safety Warnings... 3 Warranty & Usage Disclaimer... 3 Intended Use... 4 Compa bility... 4 Average Run Times... 5 Ge ng Started The Control Board... 5 Ini al Ba ery Usage... 6 Turning the Ba ery On/Off... 6 Charging the Ba ery... 6 Charging Interna onally... 6 General Charging Notes... 7 Charging Instruc ons... 7 Other Charging Op ons... 8 Powering Your PAP Device Respironics DreamSta on Series... 9-10 Respironics System One & M Series... 11-12 i

Table of Contents Powering Your PAP Device ResMed Air 10 & S9 Series... 13-15 ResMed S8 Series... 16 DeVilbiss IntelliPAP & IntelliPAP 2 Series... 16 Other PAP Devices & Travel CPAP Models... 17-19 Air Travel Usage... 20 Power Backup Usage... 20 Respironics DreamSta on Series... 21-22 Respironics System One & M Series and DeVilbiss IntelliPAP Series... ResMed Air 10 & S9 Series... 25-26 Other PAP Devices... 27-28 Powering Other Devices... 29 Understanding Lithium-Ion Ba eries... Ba ery Storage & Disposal... 30 23-24 FAQ & General Troubleshoo ng... 31-32 30 If you have any ques ons or concerns regarding the use of the Freedom CPAP Ba ery or any Ba ery Power Solu ons product please contact us at 1-877-445-5228 or info@ba erypowersolu ons.net. ii

Package Contents The Freedom CPAP Ba ery Kit includes the following components: Freedom CPAP Ba ery AC Power Supply DC Power Pigtail Cord Connector Tips (3) Le ers: N, W, J DC Input Cord NOTE: The included connector ps are compa ble with Respironics System One series, Respironics M series and DeVilbiss IntelliPAP 1 series devices. All other makes and models will require an addi onal connec on component (see below). Connec on Components Sold Separately The following components are required to connect certain models of PAP devices to the Freedom ba ery. These items are typically packaged separately and are not included in the Freedom CPAP Ba ery Kit box. ResMed DreamSta on 150W Sine Wave 24V Power Converter 12V Power Adapter Power Inverter Item #: BPS C-24V-RES Item #: BPS C-12V-DS Item #: BPS INVERTER Required for ResMed Air 10 and S9 series devices. Required for Respironics DreamSta on series devices. 1 Required for most all other PAP device models.

Product Specifica ons Cell Type: Industrial grade rechargeable lithium-ion cells (LG brand) Capacity: 97.68 Wh Output Voltage Range: 9V-12.6V DC USB Output Voltage: 5V DC 2A Output Current: 8A maximum DC Input Voltage Range: 12.6V-17V AC Power Supply Input Range: 100-240VAC 50-60Hz 1.5A AC Power Supply Output Current: 13.5V 6.75A Charging Condi ons: 32 F to 104 F Discharging Condi ons: 23 F to 104 F (ba ery capacity can be reduced by as much as 30% when discharging between 23 F to 32 F) Storage Condi ons: -4 F to 104 F (op mal range: 60 F to 80 F) Power Gauge: Digital display charge level indicator Charge Time: 4 hours (per ba ery) Life Span: 400-500 charge/discharge cycles (see page 30 for more informa on) Size: 7.5 x 4.8 x 0.8 (L x W x H) Weight: 1.7 lbs. Safety Features Ba ery Management Unit (BMU) provides internal protec on against thermal runaway (overhea ng), over voltage, over charging, over discharging, over current, and short circui ng. Aluminum alloy shell for maximum cell protec on and durability. Meets FAA requirements (< 100 Wh) for lithium-ion ba eries taken in carry-on baggage during air travel. The Freedom CPAP Ba ery has been UN 38.3 tested and meets all current safety regula ons and shipping requirements. 2

Safety Warnings The following safety warnings are to be followed at all mes! Do not drop, hit, crush, or otherwise cause any impact damage to the ba ery as this may result in exposure of the cell contents. Do not expose the ba ery to open flames, heaters, incinera on or other extreme heat, including long term exposure to direct sunlight, as exposure to extreme heat may result in a hazardous reac on. Do not expose the ba ery to moisture of any type. Do not disassemble or a empt to repair the ba ery, AC power supply or any other charging or connec on components supplied by Ba ery Power Solu ons as there are no user-serviceable parts inside. Do not use any AC power supply or other charging cable not supplied by Ba ery Power Solu ons for use with the Freedom ba ery as doing so may result in a hazardous reac on. Do not charge the ba ery on any flammable surface. Regularly inspect connec on cords and ps, the AC power supply, and any charging cables for damage or signs of wear and discon nue use if damaged. Warranty & Usage Disclaimer All Battery Power Solutions products are under warranty for manufacturing and quality defects for 1 (one) year. This warranty does not cover damage resul ng from modifica on of or improper use or opera on of the product that is not consistent with the instruc ons in this manual. By purchasing, using or possessing any Ba ery Power Solu o n s product, you are agreeing to hold harmless Ba ery Power Solu ons, its subsidiaries, affiliates, owners, officers and employees from any and all claims or liability for any damage to any property or injury, illness or death of any person when such damage, injury, illness or death shall be caused in whole or in part from use of the product(s). 3

Intended Use The Freedom CPAP Ba ery provides external power to PAP (posi ve airway pressure) devices when AC power is unavailable during travel or power outages. The Freedom ba ery may also be used to charge many common portable electronic devices such as cell phones and tablets. Use of the ba ery with a device that has higher amperage requirements than the output of the ba ery (over 8A) may cause the internal circuitry of the ba ery to shut off to protect from thermal runaway (overhea ng). Compa bility All makes and models of PAP devices have different voltage and electrical current requirements which determine the type of external ba ery that can be used. The universal design of the Freedom ba ery allows it to power the most common PAP devices; however, some models require a connec on component that is sold separately from the standard ba ery kit (see page 1 for addi onal informa on). Some older model PAP devices and targeted ven la on PAP devices may not be compa ble with the ba ery or may require more power than the ba ery can provide. The use of the heated humidifica on and/or heated tubing features of your PAP device will significantly reduce expected run mes by up to two thirds in most cases and in some cases could actually prevent the ba ery from being able to power the device. For op mal performance turn off heated humidifica on and heated tubing. Do not a empt to connect your PAP device to the Freedom ba ery before reading the connec on instruc ons for your specific device. If your device is not listed in this manual or if you have any ques ons, please contact us at 1-877-445-5228 or info@ba erypowersolu ons.net. 4

Average Run Times Mul ple factors will affect how long the Freedom ba ery will power a PAP device, including, but not limited to the PAP device type, pressure se ng, heated humidifica on or heated tubing usage, and the required connec on component type (see page 31 for addi onal informa on). Run mes are based on standard CPAP devices without the use of heated humidifica on or heated tubing on a pressure se ng of 10 cm/h2o. To increase run mes two Freedom ba eries can be pigtailed together. Single Ba ery: 1-3 nights* Dual Ba eries: 3-5 nights* *A night is generally considered 7.5 hours. For a list of specific PAP device model average run mes please visit our website at www.ba erypowersolu ons.net. Ge ng Started THE CONTROL BOARD The control board of the Freedom ba ery includes the following: A B C D E (A) DC IN JACK (D) USB OUT PORT (B) CHARGE LEVEL INDICATOR BUTTON* (E) DC OUT JACK (C) DIGITAL DISPLAY SCREEN *Press the charge level indicator bu on to illuminate the digital display screen. The screen will stay illuminated for a few seconds at a me. This bu on can also be used to reset the internal circuitry of the ba ery (see page 31 for addi onal informa on). 5

Ge ng Started INITIAL BATTERY USAGE Before using the Freedom ba ery for the first me be sure to fully charge it using AC power. It may only take a short me for the charge level to reach 100% as it is already par ally charged before it leaves the factory. Only use the AC power supply manufactured by Ba ery Power Solu ons for use with the Freedom CPAP Ba ery. TURNING THE BATTERY ON/OFF The Freedom ba ery turns on and off automa cally when a device is connected or disconnected from the DC OUT jack. When connec ng a device via the USB OUT port, the charge level indicator bu on must be pressed once the device is connected in order to ac vate power output from the USB OUT port. The ba ery will automa cally shut off when the device is disconnected from the USB OUT port. When not in use disconnect devices from the DC OUT jack or USB OUT port of the ba ery to allow the ba ery to completely shut down. Charging The Ba ery The Freedom ba ery can be charged via AC power (a wall outlet) in approximately 4 hours (per ba ery) when the ba ery is fully discharged. The ba ery does not need to be fully discharged before charging. Only use the AC power supply manufactured by Ba e r y Powe r Solu ons for use with the Freedom CPAP Ba ery. Using any other power supply may result in a hazardous reac on. Do not charge the ba ery on any flammable surface. CHARGING INTERNATIONALLY The AC power supply of the ba ery will operate on any AC current from 100-240VAC and 50/60 Hz without any adjustment. The AC power supply u lizes a type A plug. An interna onal electrical adapter plug is the only addi onal component that would be required for charging in any country. 6

Charging the Ba ery GENERAL CHARGING NOTES It is normal for the AC power supply and the ba ery to be slightly warm to the touch during the charging process. The digital display screen will show the charge level of the ba ery. Press the charge level indicator bu on to illuminate the screen. When the ba ery is fully discharged (0%) it may take some me before the display screen begins to display a charge level. During this me the display screen may flash un l it shows the charge level. If the display screen begins to flash and doesn't show a charge level, disconnect the AC power supply, press the charge level indicator bu on to illuminate the display screen, then reconnect the AC power supply to resume the charging process. When charging is complete disconnect the AC power supply from the wall outlet and the ba ery. SINGLE BATTERY CHARGING Connect the AC power cord to the AC power supply. Plug the AC power supply into the DC IN jack of the ba ery. DUAL BATTERY CHARGING Connect the AC power cord to the AC power supply. Plug the AC power supply into the DC power pigtail cord. Plug the DC power pigtail cord into the DC IN jacks of the ba eries. AC Power Cord AC Power Supply AC Power Cord AC Power Supply DC IN DC IN 7 DC Power Pigtail Cord

Other Charging Op ons When AC power is not available you can s ll keep your Freedom ba ery charged up and ready to go. Op onal accessories are available for charging the ba ery in a vehicle or by using the power of the sun. Detailed informa on on these charging accessories is available on our website at www.ba erypowersolu ons.net. AUTO CHARGE DC CABLE The Auto Charge DC Cable connects the ba ery directly to the cigare e lighter/power socket of a vehicle. The vehicle must be running during charging in order to obtain the proper voltage to successfully charge the ba ery to 100%. Do not use any charging cable not supplied by Ba ery Power Solu ons for use with the Freedom ba ery as doing so may result in a hazardous reac on. 150W SINE WAVE POWER INVERTER The 150W Sine Wave Power inverter allows you to charge the ba ery via the cigare e lighter/power socket of a vehicle by plugging the ba ery AC power supply into the inverter and then plugging the inverter into the vehicle. The vehicle does not necessarily need to be running during charging to obtain the proper voltage to successfully charge the ba ery to 100%. FREEDOM 40W SOLAR PANEL The Freedom 40W Solar Panel lets you use the power of the sun to charge the ba ery. The solar panel also comes with a DC input cord so you can charge other small electronic devices that operate from 19.2V or less such as cell phones by using the DC power cord of the device. Auto Charge DC Cable Item #: BPS DC.CABLE 150W Sine Wave Power Inverter Item #: BPS INVERTER 8 Freedom 40W Solar Panel Item #: SP40

Respironics DreamSta on Series The DC input port on Respironics DreamSta on series devices require a proprietary signal in order to recognize a valid power source; therefore, the use of a 12V power adapter is required with the Freedom ba ery. Our 12V power adapter was designed specifically for use with Respironics DreamSta on series devices and the Freedom ba ery. *Using heated humidifica on and/or heated tubing will significa nt l y reduce run mes! For op mal run mes turn these features off. REQUIRED COMPONENTS Freedom CPAP Ba ery Kit DreamSta on 12V Power Adapter SINGLE BATTERY CONNECTION Plug the 12V power adapter into the DC OUT jack of the ba ery. Plug the 12V power adapter into the DC input port of the PAP device. Turn the PAP device on and it should begin func oning. The digital display screen will show the charge level of the ba ery. Press the charge level indicator bu on to illuminate the screen. 12V Power Adapter DC OUT Device DC Input Port 9

Respironics DreamSta on Series DUAL BATTERY CONNECTION *Dual ba ery connec on will require an addi onal Freedom ba ery. Plug the 12V power adapter into the DC power pigtail cord. Plug the DC power pigtail cord into the DC OUT jacks of the ba eries. Plug the 12V power adapter into the DC input port of the PAP device. Turn the PAP device on and it should begin func oning. The digital display screen will show the charge level of the ba ery. Press the charge level indicator bu on to illuminate the screen. 12V Power Adapter DC OUT DC Power Pigtail Cord Device DC Input Port 10

Respironics System One & M Series Respironics System One and M series devices can be connected directly to the Freedom using the DC power pigtail cord and the appropriate connector p included in the ba ery kit. *Using heated humidifica on and/or heated tubing will significa nt l y reduce run mes! For op mal run mes turn these features off. REQUIRED COMPONENTS Freedom CPAP Ba ery Kit SINGLE BATTERY CONNECTION Plug the DC power pigtail cord into the DC OUT jack of the ba ery. Insert the appropriate connector p into the DC power pigtail cord. System One 60 Series: Tip with black top labeled W System One 50 & M Series: Tip with yellow top labeled N Plug the DC power pigtail cord with appropriate connector p a ached into the DC input port of the PAP device. Turn the PAP device on and it should begin func oning. The digital display screen will show the charge level of the ba ery. Press the charge level indicator bu on to illuminate the screen. DC Power Pigtail Cord with Connector Tip A ached Device DC Input Cord DC OUT DC Power Pigtail Cord 11

Respironics System One & M Series DUAL BATTERY CONNECTION *Dual ba ery connec on will require an addi onal Freedom ba ery. Plug the DC power pigtail cord into the DC OUT jacks of the ba eries. Insert the appropriate connector p into the DC power pigtail cord. System One 60 Series: Tip with black top labeled W System One 50 & M Series: Tip with yellow top labeled N Plug the DC power pigtail cord with appropriate connector p a ached into the DC input port of the PAP device. Turn the PAP device on and it should begin func oning. The digital display screen will show the charge level of the ba ery. Press the charge level indicator bu on to illuminate the screen. DC Power Pigtail Cord with Connector Tip A ached Device DC Input Cord DC OUT DC Power Pigtail Cord 12

ResMed Air 10 & S9 Series ResMed Air 10 and S9 series devices operate from 24V direct current and the Freedom ba ery provides 12V direct current; therefore, the use of a 24V power converter is required in conjunc on with the ba ery. Our 24V power converter was designed specifically for use with ResMed Air 10 and S9 series devices and the Freedom ba ery. The 24V power converter includes the converter box and two output cords. Each output cord has a tag a ached to it no ng which device it fits (either ResMed Air 10 or ResMed S9 series devices). 24V Power Converter Box S9 Output Cord Air 10 Output Cord Set the converter box and the appropriate output cord for your device aside. Do not connect the output cord to the converter box yet as the converter box must be connected to the Freedom ba ery first. The connec on instruc ons on the following pages must be followed in exact sequence in order to ini ate the voltage conversion process and thus allow the Freedom ba ery to power the device. If a er connec on you are not receiving power to the PAP device, please unplug all components and follow the instruc ons again to ensure they have been completed in exact sequence. 13

ResMed Air 10 & S9 Series REQUIRED COMPONENTS Freedom CPAP Ba ery Kit ResMed 24V Power Converter *Using heated humidifica on and/or heated tubing will significa nt l y reduce run mes! For op mal run mes turn these features off. SINGLE BATTERY CONNECTION Remember to follow all connec on steps in exact sequence. Plug the 24V power converter box into the DC OUT jack of the ba ery. Insert the appropriate output cord for your device (Air 10 or S9) into the power converter box. Plug the 24V power converter with appropriate output cord a ached into the DC input port of the PAP device. Turn the PAP device on and it should begin func oning. The digital display screen will show the charge level of the ba ery. Press the charge level indicator bu on to illuminate the screen. *Image shows connec on to a ResMed AirSense 10 PAP device. Device DC Input Port DC OUT 24V Power Converter 14

ResMed Air 10 & S9 Series DUAL BATTERY CONNECTION *Dual ba ery connec on will require an addi onal Freedom ba ery. Remember to follow all connec on instruc ons in exact sequence. Plug the DC power pigtail cord into the DC OUT jacks of the ba eries. Plug the 24V power converter box into the DC power pigtail cord. Insert the appropriate output cord for your device (Air 10 or S9) into the power converter box. Plug the 24V power converter with output cord a ached into the DC input port of the PAP device. Turn the PAP device on and it should begin func oning. The digital display screen will show the charge level of the ba ery. Press the charge level indicator bu on to illuminate the screen. *Image shows connec on to a ResMed AirSense 10 PAP device. Device DC Input Port DC Power Pigtail Cord DC OUT 24V Power Converter 15

ResMed S8 Series ResMed S8 series devices operate from 12V direct current but the DC input port runs opposite polarity from the Freedom ba ery; therefore, the use of the 150W sine wave power inverter is required. DO NOT connect a ResMed S8 device to the ba ery without using the sine wave power inverter as doing so will cause irreversible damage to the PAP device. The connec on instruc ons will be the same as those in the Other PAP Devices & Travel CPAP Models sec on on pages 17-19. Instruc on sheets with images are available at www.ba erypowersolu ons.net under the "specifica ons tab" for the Freedom ba ery. DeVilbiss IntelliPAP & IntelliPAP 2 Series DeVilbiss IntelliPAP series devices can be connected directly to the Freedom ba ery using the DC power pigtail cord and the connector p with the blue top labeled J included in the ba ery kit. The connec on instruc ons will be the same as those in the Respironics System One & M Series sec on on pages 11-12 except you will plug the J connector p in the DC power pigtail cord. The ends of the "J" p are the same size and it does not ma er which end is plugged into the ba ery versus the IntelliPAP device. DeVilbiss IntelliPAP 2 series devices require the use of the 150W sine wave power inverter in conjunc on with the Freedom ba e r y. The connec on instruc ons will be the same as those in the Other PAP Devices & Travel CPAP Models sec on on pages 17-19. Instruc on sheets with images for both the IntelliPAP and IntelliPAP 2 series devices are available at www.ba erypowersolu ons.net under the "specifica ons tab" for the Freedom ba ery. 16

Other PAP Devices & Travel CPAP Models The Freedom ba ery can power most all other common PAP devices and travel CPAP models including, but not limited to the following: Fisher & Paykel ICON DeVilbiss IntelliPAP 2 3B Medical RESmart & Luna Apex Medical XT ResMed AirMini Respironics DreamSta on Go Somne cs Transcend HDM Z1 To power these other common PAP devices and travel CPAP models the 150W sine wave power inverter must be used in conjunc on with the Freedom ba ery as noted in the instruc on example on the following pages. Instruc on sheets with images for the models listed above are available at www.ba erypowersolu ons.net under the "specifica ons tab" for the Freedom ba ery. Due to the ini al power draw required to start some of these PAP device models the connec on instruc ons should be followed in exact sequence in order to prevent tripping the circuitry of the ba ery. If the ba ery shuts down immediately or very soon a er connec ng it to the device, reset the internal circuitry of the ba ery (see page 32 for instruc ons) and follow the instruc ons again to ensure they have been done in sequence. If the ba ery con nues to shut down the device you are a emp ng to power may not be compa ble (see page 32 for more informa on). 17

Other PAP Devices & Travel CPAP Models *Using heated humidifica on and/or heated tubing will significa nt l y reduce run mes! For op mal run mes turn these features off. REQUIRED COMPONENTS Freedom CPAP Ba ery Kit 150W Sine Wave Power Inverter (power inverter) SINGLE BATTERY CONNECTION Plug the DC input cord into the DC OUT jack of the ba ery. Plug the power inverter into the DC input cord. Plug the AC power cord of the PAP device into the power inverter. Plug the AC power cord into the PAP device. Turn the PAP device on and it should begin func oning. The digital display screen will show the charge level of the ba ery. Press the charge level indicator bu on to illuminate the screen. *Image shows connec on to a Fisher & Paykel ICON device. Device AC Power Cord Power Inverter DC OUT 18 DC Input Cord

Other PAP Devices & Travel CPAP Models DUAL BATTERY CONNECTION *Dual ba ery connec on will require an addi onal Freedom ba ery. Plug the DC power pigtail cord into the DC OUT jacks of the ba eries. Plug the DC input cord into the DC power pigtail cord. Plug the power inverter into the DC input cord. Plug the AC power cord of the PAP device into the power inverter. Plug the AC power cord into the PAP device. Turn the PAP device on and it should begin func oning. The digital display screen will show the charge level of the ba ery. Press the charge level indicator bu on to illuminate the screen. *Image shows connec on to a Fisher & Paykel ICON device. Device AC Power Cord Power Inverter DC Input Cord DC Power Pigtail Cord DC OUT 19

Air Travel Usage The Freedom CPAP Ba ery meets current FAA requirements for spare lithium-ion ba eries (not installed in a device) taken in carry-on baggage as each ba ery is less than 100Wh (97.68Wh) and is protected from damage and short circuit. Spare lithium-ion ba eries are not allowed in checked baggage and must only be taken in carry-on baggage. TSA security, individual airline, and interna onal rules may, at mes, be more restric ve. If you are planning to use the Freedom ba ery during flight it is recommended that you contact your airline as they may have specific requirements regarding the use of PAP devices and/or lithium-ion ba eries during flight. For more informa on view the FAQ sec on on our website at www.ba erypowersolu ons.net. Power Backup Usage The Freedom CPAP Ba ery can be used as a true ba ery backup system for your PAP device during power outages. When you sleep you may leave your PAP device connected to the ba ery and then plug the ba ery into a wall outlet. In the event AC power (power from a wall outlet) is lost the ba ery will automa cally begin powering your PAP device uninterrupted. When AC power is available it will bypass the lithium-ion cells within the Freedom ba ery and power your device normally without degrading the overall lifespan of the ba ery as the cells of the ba ery will not con nuously be charging and then discharging. You may use the Freedom ba ery in this power backup scenario using a single ba ery or in the dual ba ery configura on; however, in the dual ba ery configura on you will need to purchase an addi onal DC power pigtail cord in order to connect both ba eries to the AC power supply of the ba ery and then both ba eries to your PAP device. When not in use we recommend disconnec ng the AC power supply and the PAP device from the Freedom ba ery to allow the ba ery to completely shut down. 20

Power Backup: Respironics DreamSta on Series REQUIRED COMPONENTS Freedom CPAP Ba ery Kit DreamSta on 12V Power Adapter SINGLE BATTERY CONNECTION Plug the ba ery AC power supply into the DC IN jack of the ba ery. Plug the AC power supply into a wall outlet. Plug the 12V power adapter into the DC OUT jack of the ba ery. Plug the 12V power adapter into the DC input port of the PAP device. The digital display screen will show the charge level of the ba ery. Press the charge level indicator bu on to illuminate the screen. Ba ery AC Power Supply Device DC Input Port 12V Power Adapter DC OUT DC IN 21

Power Backup: Respironics DreamSta on Series DUAL BATTERY CONNECTION *Dual ba ery connec on will require an addi onal Freedom ba ery and an addi onal DC power pigtail cord (item # BPS PIGTAIL.FD). Plug the ba ery AC power supply into the first DC power pigtail cord. Plug the first DC power pigtail cord into the DC IN jacks of the ba eries. Plug the AC power supply into a wall outlet. Plug the second DC power pigtail cord into the DC OUT jacks of the ba eries. Plug the 12V power adapter into the second DC power pigtail cord. Plug the 12V power adapter into the DC input port of the PAP device. The digital display screen will show the charge level of the ba ery. Press the charge level indicator bu on to illuminate the screen. Ba ery AC Power Supply Device DC Input Port 12V Power Adapter DC OUT DC IN First DC Power Pigtail Cord Second DC Power Pigtail Cord 22

Power Backup: Respironics System One & M Series and DeVilbiss IntelliPAP Series REQUIRED COMPONENTS Freedom CPAP Ba ery Kit SINGLE BATTERY CONNECTION Plug the ba ery AC power supply into the DC IN jack of the ba ery. Plug the AC power supply into a wall outlet. Plug the DC power pigtail cord into the DC OUT jack of the ba ery. Insert the appropriate connector p into the DC power pigtail cord. System One 60 Series: Tip with black top labeled W System One 50 & M Series: Tip with yellow top labeled N IntelliPAP Series: Tip with blue top labeled J Plug the DC power pigtail cord with appropriate connector p a ached into the DC input port of the PAP device. The digital display screen will show the charge level of the ba ery. Press the charge level indicator bu on to illuminate the screen. *Note: DeVilbiss IntelliPAP 2 series devices will connect to the Freedom ba ery via the 150W sine wave power inverter (see pages 27-28 for connec on instruc ons). Connector Tip Inserted Into Device DC Input Port Ba ery AC Power Supply DC IN DC OUT DC Power Pigtail Cord 23

Power Backup: Respironics System One & M Series and DeVilbiss IntelliPAP Series DUAL BATTERY CONNECTION *Dual ba ery connec on will require an addi onal Freedom ba ery and an addi onal DC power pigtail cord (item # BPS PIGTAIL.FD). Plug the ba ery AC power supply into the first DC power pigtail cord. Plug the first DC power pigtail cord into the DC IN jacks of the ba eries. Plug the AC power supply into a wall outlet. Plug the second DC power pigtail cord into the DC OUT jacks of the ba eries. Insert the correct connector p into the second DC power pigtail cord. System One 60 Series: Tip with black top labeled W System One 50 & M Series: Tip with yellow top labeled N IntelliPAP Series: Tip with blue top labeled J' Plug the second DC power pigtail cord with correct connector p a ached into the DC input port of the PAP device. The digital display screen will show the charge level of the ba ery. Press the charge level indicator bu on to illuminate the screen. *Note: DeVilbiss IntelliPAP 2 series devices will connect to the Freedom ba ery via the 150W sine wave power inverter (see pages 27-28 for connec on instruc ons). Ba ery AC Power Supply Connector Tip Inserted Into Device DC Input Port DC IN DC OUT Second DC Power Pigtail Cord First DC Power Pigtail Cord 24

Power Backup: ResMed Air 10 & S9 Series REQUIRED COMPONENTS Freedom CPAP Ba ery Kit ResMed 24V Power Converter SINGLE BATTERY CONNECTION The connec on instruc ons below must be followed in exact sequence. See pages 13-15 for addi onal informa on. Plug the ba ery AC power supply into the DC IN jack of the ba ery. Plug the AC power supply into a wall outlet. Plug the 24V power converter box into the DC OUT jack of the ba ery. Insert the appropriate output cord for your device (Air 10 or S9) into the power converter box. Plug the 24V power converter with appropriate output cord a ached into the DC input port of the PAP device. Turn the PAP device on and it should begin func oning. The digital display screen will show the charge level of the ba ery. Press the charge level indicator bu on to illuminate the screen. Ba ery AC Power Supply Device DC Input Port DC IN DC OUT 24V Power Converter 25

Power Backup: ResMed Air 10 & S9 Series DUAL BATTERY CONNECTION *Dual ba ery connec on will require an addi onal Freedom ba ery and an addi onal DC power pigtail cord (item # BPS PIGTAIL.FD). The connec on instruc ons below must be followed in exact sequence. See pages 13-15 for addi onal informa on. Plug the ba ery AC power supply into the first DC power pigtail cord. Plug the first DC power pigtail cord into the DC IN jacks of the ba eries. Plug the AC power supply into a wall outlet. Plug the second DC power pigtail cord into the DC OUT jacks of the ba eries. Plug the 24V power converter box into the second DC power pigtail cord. Insert the appropriate output cord for your device (Air 10 or S9) into the power converter box. Plug the 24V power converter with output cord a ached into the DC input port of the PAP device. Turn the PAP device on and it should begin func oning. The digital display screen will show the charge level of the ba ery. Press the charge level indicator bu on to illuminate the screen. Ba ery AC Power Supply Device DC Input Port 24V Power Converter First DC Power Pigtail Cord DC IN DC OUT 26 Second DC Power Pigtail Cord

Power Backup: Other PAP Devices REQUIRED COMPONENTS Freedom CPAP Ba ery Kit 150W Sine Wave Power Inverter (power inverter) SINGLE BATTERY CONNECTION Plug the ba ery AC power supply into the DC IN jack of the ba ery. Plug the AC power supply into a wall outlet. Plug the DC input cord into the DC OUT jack of the ba ery. Plug the power inverter into the DC input cord. Plug the AC power cord of the PAP device into the power inverter. Plug the AC power cord into the PAP device. The digital display screen will show the charge level of the ba ery. Press the charge level indicator bu on to illuminate the screen. *Image example shows a 3B Medical Luna device. Device AC Power Supply Power Inverter Ba ery AC Power Supply DC OUT DC IN DC Input Cord 27

Power Backup: Other PAP Devices DUAL BATTERY CONNECTION *Dual ba ery connec on will require an addi onal Freedom ba ery and an addi onal DC power pigtail cord (item # BPS PIGTAIL.FD). Plug the ba ery AC power supply into the first DC power pigtail cord. Plug the first DC power pigtail cord into the DC IN jacks of the ba eries. Plug the AC power supply into a wall outlet. Plug the DC input cord into the second DC power pigtail cord. Plug the second DC power pigtail cord into the DC OUT jacks of the ba eries. Plug the power inverter into the DC input cord. Plug the AC power cord of the PAP device into the power inverter. Plug the AC power cord into the PAP device. The digital display screen will show the charge level of the ba ery. Press the charge level indicator bu on to illuminate the screen. *Image example shows a 3B Medical Luna device. Ba ery AC Power Supply Device AC Power Supply Power Inverter DC IN First DC Power Pigtail Cord 28 DC OUT DC Input Cord Second DC Power Pigtail Cord

Powering Other Devices The Freedom ba ery can be used to power many portable electronic devices such as cell phones and tablets via the 5V USB port, DC input cord or the 150W sine wave power inverter. USB PORT CONNECTION Plug the device USB cord into the USB OUT port of the ba ery. Press the charge level indicator bu on once to ini ate power output from the USB OUT port. *NOTE: It is possible to have a portable electronic device and a PAP device connected to the Freedom ba ery simultaneously; however, this could impact PAP device run mes. DC INPUT CORD CONNECTION Plug the DC input cord into the DC OUT jack of the ba ery. Plug the device DC power cord into the DC input cord. USB OUT DC OUT Charge Level Indicator Bu on Device USB Cord Device DC Power Cord DC Input Cord USB PORT CONNECTION DC INPUT CORD CONNECTION 150W SINE WAVE POWER INVERTER CONNECTION You can also connect portable electronic devices that do not have a USB cord or DC power cord by using the 150W sine wave power inverter in conjunc on with the Freedom ba ery. See pages 18-19 for instruc ons and simply replace the PAP device with the portable electronic device. 29

Understanding Lithium-Ion Ba eries Understanding common phenomenon with rechargeable lithium-ion ba eries can help you be er care for your Freedom CPAP Ba ery and answer many common ques ons regarding usage. Lithium-ion ba eries do not suffer the memory effects that are associated with other types of ba ery chemistries. This means the ba ery does not need to be completely discharged before charging. Upon ini al use or a er prolonged storage lithium-ion ba eries may require 3-4 charge and discharge cycles before achieving their maximum capacity. Lithium-ion ba eries will self-discharge when unused; therefore, the ba ery will need to be charged a er a storage period. On average the ba ery will self-discharge by 20% every 30 days. The amount of charge lithium-ion ba eries will hold will gradually decrease due to usage and aging. Over me the actual ba ery capacity decreases as less and less ac ve material within each lithium-ion cell is available to electrochemically store a charge. This loss in capacity is true for all rechargeable lithium-ion ba eries. Under normal condi ons the average life span of the Freedom ba ery is generally around 400-500 charge and discharge cycles. Ba ery Storage & Disposal Fully charge the ba ery before storage. Store the ba ery in a dry, cool, and well ven lated place away from extreme heat and direct sunlight. Storage temperature range is -4 F to 104 F; however, the op mal range is 60 F to 80 F. For op mal performance charge and discharge the Freedom ba ery once every 90 days. Lithium-ion ba eries should be recycled and many U.S. states have laws regarding ba ery disposal. For informa on on disposal facili es near you call 1-877-723-1297 or visit www.call2recycle.org. 30

FAQ & General Troubleshoo ng LOWER THAN EXPECTED RUN TIMES Below are the most common factors that impact how long the Freedom ba ery will power a PAP device: Heated Humidifica on & Heated Tubing: Using these features will significantly reduce run mes by two thirds in most cases and in some cases could prevent the ba ery from being able to power the device. For op mal ba ery performance these features should be turned off. If heated humidifica on is required, lowering the heat se ngs may help increase run mes; otherwise, two ba eries can be pigtailed together to increase run mes. High Pressure Se ng: Higher pressure se ngs (above 18 cm/h2o) can impact run mes especially when other factors are present. All run me tes ng is done on a pressure se ng of 10 cm/h2o. Mask Fit: A leaking mask can impact run mes as the PAP device will be working harder to maintain the prescribed pressure se ng and thus be drawing more power from the ba ery. PAP Device Type: BiLevel devices will have lower run mes as the pressure se ng is not constant and changes throughout the night requiring more power to operate the device. Some older, obsolete device models and newer targeted ven la on devices require a much higher power draw than today s standard CPAP devices and therefore can result in lower run mes or could prevent the ba ery from being able to power the device. Connec on Method: Some of the connec on components required to connect specific PAP device models do draw power from the ba ery but this has been factored into the listed average run mes. DUAL BATTERY CONFIGURATION While both ba eries are providing output power simultaneously, the ba ery with the highest charge level will generally be the one to display DC 12V under the ba ery symbol on the digital display screen. Also note that due to the circuit board differences a Freedom CPAP Ba ery cannot be pigtailed with an older model C-100 CPAP Ba ery. 31

FAQ & General Troubleshoo ng BATTERY STARTS THEN STOPS WORKING If the ba ery stops func oning you can reset its internal circuitry by using the instruc ons below. If the ba ery con nues to shut down, the device you are a emp ng to power may not be compa ble. The device may have higher amperage requirements (over 8A) than the ba ery can provide. The device may require a constant voltage output to operate properly. The Freedom ba ery has a voltage range of 9V-12.6V DC and does not maintain a constant voltage level. The internal circuitry of the device may be set to automa cally adjust to accommodate for mul -voltage capabili es which could make it compa ble with the ba ery at mes and incompa ble at other mes. RESETTING THE INTERNAL CIRCUITRY OF THE BATTERY If the ba ery stops func oning you can reset its internal circuitry by holding down the charge level indicator bu on for a full 10 seconds. The digital display screen will flash and two dash marks will appear. Release the bu on and wait un l the screen goes blank for the circuit board of the ba ery to reset. PAP DEVICE CONNECTION VIA A 12V DC POWER CORD While it is possible to connect a PAP device to the Freedom ba e r y using the 12V DC power cord supplied by the device manufacturer and the DC input cord included with the ba ery kit, the device may only run for a short period of me. This can occur because many DC power cords require a constant 12V power flow in order to work properly and the Freedom ba ery func ons on a voltage range of 9V-12.6V DC. TECHNICAL SUPPORT If you have any ques ons regarding the use of the Freedom ba ery please contact us at 1-877-445-5228 or info@ba erypowersolu ons.net. Do not a empt to service the Freedom CPAP ba ery or any connec on or charging components yourself. 32

1-877-445-5228 www.ba erypowersolu ons.net FREEDOM CPAP BATTERY USER MANUAL February 2019