Liebert DCW CATALOGUE

Similar documents
Liebert DCW Family Chilled Water-Based High Density Cooling For The Data Center. Precision Cooling For Business-Critical Continuity

Liebert XD. Cooling Solutions For High Heat Density Applications. Precision Cooling For Business-Critical Continuity

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power

DATA CENTER PRECISION COOLING: The Need For A Higher Level Of Service Expertise

Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer

Liebert XD Flexible, Energy-Saving Cooling Solutions For High Heat Density Applications. Precision Cooling For Business-Critical Continuity

Liebert. HPC-S Free Cooling Chiller Designed for the Efficient Cooling of Small Data Centers

Liebert. CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

Data Center Precision Cooling: The Need For A Higher Level Of Service Expertise. A White Paper from the Experts in Business-Critical Continuity

Data Center Assessment Helps Keep Critical Equipment Operational. A White Paper from the Experts in Business-Critical Continuity TM

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

SMARTMOD Intelligent, Integrated Infrastructure for the Data Center

A) Differences between Precision and Comfort Cooling Here are the major differences exist between precision air conditioning and comfort systems.

2016 COOLING THE EDGE SURVEY. Conducted by Vertiv Publication Date: August 30, 2016

PEX+ High Efficiency, Low Operating Cost Precision Solution for Data Centers

Liebert. DCL up to 35 kw. Modular Rack Cooling

Next Generation Cooling

SMARTAISLE Intelligent, Integrated Infrastructure for the Data Center

Liebert XDA Air Flow Enhancer. User Manual

Liebert Economizer Cooling Solutions Reduce Cooling Costs by up to 50% Without Compromising Reliability

Liebert. DSE Thermal Management System Free Cooling Economization Without Using Water

Liebert. DCL up to 35 kw. Modular Rack Cooling

IT Air Conditioning Units

Powering Change in the Data Center. A White Paper from the Experts in Business-Critical Continuity TM

MSYS 4480 AC Systems Winter 2015

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire

INNOVATE DESIGN APPLY.

INNOVATE DESIGN APPLY.

SmartRow Solution Intelligent, Integrated Infrastructure for the Data Center

Five Strategies for Cutting Data Center Energy Costs Through Enhanced Cooling Efficiency

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

Liebert. icom Thermal System Controls Greater Data Center Protection, Efficiency & Insight

SmartRow Intelligent, Integrated Infrastructure in a Self-Contained Line-Up. Solutions For Business-Critical Continuity

Cooling on Demand - scalable and smart cooling solutions. Marcus Edwards B.Sc.

Liebert : The Right Cooling For IT Environments

Power and Cooling for Ultra-High Density Racks and Blade Servers

Efficiency of Data Center cooling

SmartMod Intelligent, Integrated Infrastructure for the Data Center

PEX (R410A) High Efficiency, Green Solution Precision Cooling for Data Centers

Close Coupled Cooling for Datacentres

Switch to Perfection

Liebert. PDX and PCW Compact Perimeter Cooling Solutions

Liebert. PDX from 15 to 165 kw. Direct Expansion Solution for Small and Medium Data Centers

FREECOOLING, EVAPORATIVE AND ADIABATIC COOLING TECHNOLOGIES IN DATA CENTER. Applications in Diverse Climates within Europe, Middle East and Africa

Google s Green Data Centers: Network POP Case Study

TWO FINANCIAL IMPACT STUDIES. Seal IT Equipment Cabinets for Significant Annual Cost Savings and Simple Payback in a Few Short Months

Datacenter Efficiency Trends. Cary Roberts Tellme, a Microsoft Subsidiary

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

Precision Cooling. Precision Cooling Advantages

Rack & Enclosure Systems

Ten Cooling Solutions to Support High-density Server Deployment. Schneider Electric Data Center Science Center White Paper #42

ENCLOSURE HEAT DISSIPATION

SUPERSAVER. Energy Efficiency Optimization Software for Freecooling Systems

Avoidable Mistakes that Compromise Cooling Performance in Data Centers and Network Rooms

Aisle Containment Systems. Physical Containment Systems Selection Guide

Moving Containment Inside the Enclosure. Jeff Markle Great Lakes Case & Cabinet

SmartAisle Intelligent, Integrated Infrastructure Using Row-based Building Blocks. Solutions For Business-Critical Continuity

Liebert DSE Precision Cooling System Industry-best efficiency. Increased capacity. Ensured availability. EFFICIENCY. CAPACITY. AVAILABILITY.

Two-Stage Power Distribution: An Essential Strategy to Future Proof the Data Center

Liebert PDX from 15 to 120 kw

SmartCabinet Intelligent, Integrated Containment for IT Infrastructure

Total Modular Data Centre Solutions

HIGH DENSITY RACK COOLING CHOICES

Liebert PDX. The Cooling Solution for Small and Medium Data Centers. Digital Scroll. Part Load. Competent Partner Efficiency

How Liquid Cooling Helped Two University Data Centers Achieve Cooling Efficiency Goals. Michael Gagnon Coolcentric October

Thermal management. Thermal management

Energy Logic: Emerson Network Power. A Roadmap for Reducing Energy Consumption in the Data Center. Ross Hammond Managing Director

Reducing Data Center Cooling Costs through Airflow Containment

Current Data Center Design. James Monahan Sept 19 th 2006 IEEE San Francisco ComSoc

HIGH DENSITY DATACOM INTEGRATED COOLING SYSTEM.

84 kw, Tier 3, Direct Expansion, 937 ft 2

Green IT and Green DC

Smart Data Centres. Robert M Pe, Data Centre Consultant HP Services SEA

Application of TileFlow to Improve Cooling in a Data Center

A Green Approach. Thermal

Liebert PDX from 15 to 120 kw

SMART SOLUTIONS TM INTELLIGENT, INTEGRATED INFRASTRUCTURE FOR THE DATA CENTER

New Techniques for Energy-Efficient Data Center Cooling

Rethinking Datacenter Cooling

Variable Density, Closed-Loop, Water-Cooled Data Center Solution

Evaporative free air cooling technology Providing evaporative free air cooling solutions.

Liebert. AFC from 500 to 1700 kw. The Adiabatic Freecooling Solution with Top-Tier Availability

PROCESS & DATA CENTER COOLING. How and Why To Prepare For What s To Come JOHN MORRIS REGIONAL DIRECTOR OF SALES

Schneider Electric Cooling Portfolio. Jim Tubbesing Heath Wilson APC/Schneider North Texas Rep Tubbesing Solutions

CRITICAL INFRASTRUCTURE ASSESSMENTS

HP Modular Cooling System: water cooling technology for high-density server installations

A Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System

Where s the Heat Coming From. Leland Sparks Global Account Technical Consultant Belden

Server Room & Data Centre Energy Efficiency. Technology Paper 003

COOLING SOLUTIONS. SmartRack Close-Coupled Cooling for IT Environments

Ten Cooling Solutions to Support High- Density Server Deployment

2000 kw, Tier 3, Chilled Water, Prefabricated, sq. ft.

3300 kw, Tier 3, Chilled Water, 70,000 ft 2

AisleLok Modular Containment vs. Legacy Containment: A Comparative CFD Study of IT Inlet Temperatures and Fan Energy Savings

Impact of Air Containment Systems

APMTM UPS 30kW - 300kW The Compact Row-Based UPS With Flexpower Technology

Liebert. PCW from 25 to 220 kw. Chilled Water Units Optimizing Data Center Efficiency

Effectiveness and Implementation of Modular Containment in Existing Data Centers

Virtualization and consolidation

Transcription:

Liebert DCW CATALOGUE Chilled Water-Based High Density Cooling For The Data Center

LIEBERT DCW Flexible Approaches For Energy Efficient Cooling Save up to 70% in cooling energy usage Data center managers are constantly faced with the challenge of reducing energy consumption and increasing processing capacity, without compromising business activities. The Liebert DCW chilled water-based high density cooling family provides energy savings of up to 70% over traditional cooling. The modular approach allows additional cooling to be added as compute capacity grows, without disruption of the data center. Adding targeted cooling is more cost-efficient than trying to lower the temperature of the entire data center by increasing the overall room air conditioning capacity. Liebert DCW mission-critical cooling systems are specifically designed to address the higher heat loads generated by tightly packed electronic rack enclosures. Liebert DCW Water-Based Systems Liebert DCW is a family of water-cooled systems that offers a cost-efficient cooling alternative. They are designed to work in any size space from a small computer room to a large data center with loads from 5 to 35 kw per rack. Business continuity professionals are demanding an integrated high heat density cooling solution one that considers both room-level and rack-level needs. Effective Solutions need to be flexible Added as heat loads increase, Liebert DCW cooling capacity allows your facility to adapt as heat loads rise allowing cooling solutions to be added to react to the changes in your environment. Benefits of the Liebert DCW approach include: Lowest Total Cost of Ownership ytotal energy savings potential of up to 70% ymore cost-effective than increasing the overall room air conditioning capacity using floor-mounted cooling units only yminimal floor space requirements 100% 80% Normalized Annual Energy Usage Flexibility ycan cool more than 35 kw per rack ydesigned to work with or without the hot aisle/cold aisle yworks with or without raised floor 60% 40% 70% in Energy Higher Availability yensures continuous operation of critical IT systems under extreme heat conditions 20% ylocal service and support experts, and 24 hour support call center 0% Traditional Chilled Water Floormount Liebert DCP + Liebert DCD System 2

Liebert DCW Solutions Cut Capital Costs Investing in a facility that utilizes a higher rack density design along with a cooling system designed especially for this type of installation offers a significant cost savings advantage in terms of building size and energy usage. The flexible configuration of the Liebert DCW system modules also allows scalability for future growth and significantly improves floor space utilization compared to an installation using only floor-mounted cooling units. Installing more Liebert DCW capacity uses little or no additional floor area. Total Data Center Cost (less land) ($000) $30,000 $25,000 $20,000 $15,000 $10,000 $5,000 $0 Data Center Cost (New Construction) 50 W/sq.ft 2 (500 W/m ) Fixed Load of 4,000 kw Cooling System Building Cost Less Cooling 150 W/sq.ft 400 W/sq.ft (1500 W/m 2 ) (4000 W/m 2 ) 80,000 sq.ft. 27,000 sq.ft. 10,000 sq.ft. 8,000 m 2 2,700 m 2 1,000 m 2 Building Size The capital costs of a data center are significantly reduced as higher densities of IT equipment are housed in smaller sized areas. Study Data Center Cost (New Construction) 400 racks with an average heat load of 10 kw each. Cost for building, power, cooling, lighting, fire protection, security, etc. included. Cost of land not included. Building 1: 80,000 sq.ft. (8000m2), 18 (450mm) Raised Floor, Designed for 50 W/sq.ft (500W/m2), Raised-floor Precision Air Conditioning units for cooling. Building 2: 27,000 sq.ft. (2700m2), 36 (900mm) Raised Floor. Designed for 150 W/sq.ft (1500W/m2), Raised-floor Precision Air Conditioning units for cooling. Building 3: 10,000 sq.ft. (1000m2), 18 (450mm) Raised Floor. Designed for 400 W/sq.ft (4000W/m2), Raised-floor Precision Air Conditioning units (for basic cooling and humidity control) and Liebert XD. Liebert XD - Supplemental Cooling Requires less Chiller Capacity Chiller Capacity One of the major areas of savings identified with the use of Liebert DCW equipment is the ability to reduce chiller plant size. This is because the chiller typically is sized for the total gross capacity of the raised-floor cooling units. The 65% lower fan load of the Liebert DCW System modules and the fact they are 100% sensible results in a capital chiller size savings of 15% or more. kw power to cool 1 kw of sensible heat kw Chiller Capacity per kw Of Sensible Heat Load 1.40 1.20 1.00 0.80 0.60 0.40 0.20 0.00 CW CRAC 15% Lower Liebert XD Latent Load Fan Load Sensible Load Liebert XD - Supplemental Cooling with Lower Operating Costs Power Usage 0.60 0.50 0.40 0.30 0.20 0.10 0.00 CW CRAC at 100% Capacity CW CRAC at 50% Capacity 27% Lower Liebert XD at 100% Capacity Fan Pump (XD) Pump (CW) Chiller 32% Lower Liebert XD at 50% Capacity The smaller chiller plant and lower fan load result in significant energy savings as well. A 27% energy savings is very conservative. 3

LIEBERT DCW The Liebert DCW cooling solution can provide 200 kw of sensible cooling, with modules capable of providing localized cooling up to 35 kw per rack. High Heat Density. High Temperatures. With constant introduction of new technology, the computing capacity that once filled an entire room can now be contained within a single rack. Blade servers, communication switches and other electronics are packed into racks creating increased heat densities that cannot be effectively cooled by traditional cooling solutions. This compacted capacity means higher heat densities. What was once a 1 kw rack or 10 kw rack may now exceed 30 kw. This requires a shift in focus from a traditional room-based view of cooling to a rack-based view. IT decision makers must consider both watt per square foot and kw per rack when evaluating cooling solutions. No Relief in Sight: Heat Loads Rising Heat load per equipment footprint (watt/equipment sq.ft.) 10,000 100,000 8,000 6,000 60,000 4,000 2,000 20,000 1,000 10,000 800 600 6,000 400 4,000 200 2,000 100 60 Communication - Extreme Density Computer Servers Storage Servers Workstations (standalone) Tape Storage 800 1992 1994 1996 1998 2000 2002 2004 2006 2008 2010 2012 2014 Year of Product Announcement ASHRAE, Datacom Equipment Power Trends and Cooling Applications, 2005. American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., www.ashrae.org And, They Attack Your Facility in Two Ways Hotter Facilities As processor capabilities increase, so do computer room power densities from 50 Watt per square foot (540W/ m2) to over 300 Watt per square foot (320W/m2). Your whole data center just keeps getting hotter. Communication - Extreme Density Computer Servers - 1U, Blade and Custom Communication - High Density Computer Servers - 2U and Greater Storage Servers Workstations (standalone) Tape Storage Hot Spots Compounding the problem, this higher heat load is not evenly distributed throughout the room. Sometimes, power densities can grow into hundreds of Watt per square foot, creating localized hot spots of extreme heat. Heat load per equipment footprint (watts/equipment sq.m.) 50W TO 300W 600+W 4

Room-Neutral Cooling A common way to improve performance of existing raised floor cooling applications has been the hot aisle/cold aisle approach. In this configuration, rows of equipment racks are arranged in alternating hot and cold aisles. Only the cold aisles have perforated floor tiles that allow cool air to come up from under the raised floor. The Liebert DCW solution is compatible with existing hot aisle/cold aisle application. Some room and equipment designs preclude the hot aisle/cold aisle configuration. These are often well-suited to cooling with the Liebert DCW system. ythe Liebert DCD door neutralizes the server s exhaust air before it leaves the rack. ythe Liebert XDK-W enclosed rack contains and cools the hot air within the cabinet. Unfortunately, even when using a hot aisle/cold aisle configuration, the limits of standard underfloor cooling are soon reached as rack heat loads increase. F / C 100 / 38 90 / 32 80 / 27 70 / 21 60 / 16 Heat Load = 3 kw Per Rack With Hot Aisle /Cold Aisle Layout F / C 87 / 31 80 / 27 73 / 23 66 / 19 60 / 16 Heat Load = 3 kw Per Rack With Hot Aisle /Cold Aisle Layout F / C 98 / 37 88 / 31 79 / 26 69 / 21 60 / 16 Heat Load = 6 kw Per Rack With Hot Aisle /Cold Aisle Layout F / C 115 / 46 101 / 38 87 / 31 73 / 23 60 / 16 Heat Load = 10 kw Per Rack With Hot Aisle /Cold Aisle Layout Side views of Computational Fluid Dynamics (CFD) by Fluent showing limitations of hot aisle/cold aisle approach as heat load increases. 5

LIEBERT DCW Liebert DCW Cooling Solutions 200 kw of Sensible Cooling The Liebert DCP Coolant Pumping Unit is the key to the performance, efficiency and space saving design of the Liebert DCD passive chilled water door and Liebert XDK-W water- cooled rack enclosure. The unit houses the isolating heat exchanger between the Liebert DCD/XDK-W circuit fluid and building chilled water, the control valve, the dual redundant pumps and the system controls. It controls the fluid temperature above the actual room dewpoint. The Liebert DCP can also be used with other brands of rack cooling equipment. Building Chilled Water Building Chilled Water Liebert DCP Pumping Unit Chilled Water Liebert DCD or Liebert XDKW Liebert DCD or Liebert XDKW Liebert DCP Pumping Unit Chilled Water Liebert DCD or Liebert XDKW Liebert DCD or Liebert XDKW The Liebert DCP isolates the building s chilled water circuit from the chilled water circuit within the data center. Separating the data center from the building chiller also minimizes the impact of a leak within the data center. Should a leak occur, the volume of water is limited to the amount within the secondary piping system instead of the entire building chiller system. The separation from the building chiller system also ensures proper water quality to the cooling modules in the data center by creating a closed loop system. The Liebert DCP circulates the chilled water to cooling modules (Liebert DCD or Liebert XDK-W) while preventing condensation by maintaining the water temperature above the room dew point. Intelligent System Control The Liebert icom control system on the Liebert DCP features maintenance history, spare parts list, Liebert IntelliSlot for up to two cards (web compatibility and BMS), and comprehensive monitoring. The enhanced Liebert icom with its IT-focused user interface allows real-time monitoring and data capture. Status may be reported back to the BMS via Liebert IntelliSlot communications cards. 6

Room-neutral Cooling Over 35 kw Per Rack High density cooling that won t add heat to your room. Liebert DCW Cooling Modules Open Architecture Liebert DCD Rack Door Cooling Module Replaces the back door of a server enclosure, providing cooling without increasing the rack footprint. The module uses the server fans within the protected rack to provide airflow, providing the most energy efficient design. ycan cool over 35 kw per Rack yno electrical components yno noise ystationary connections yfull access to rear of rack yadapts to Vertiv DCM racks or racks by other manufacturers Closed Architecture Liebert XDK-W High Density Cooling Enclosure Utilizes closed air circulation, the racks are completely sealed from room air. The server heat load is dissipated into the process chilled water system through an air-to-water heat exchanger in the bottom of the rack. Redundant high-performance fans drive closed loop air circulation in the rack s interior, while servers are supplied with cold air at the front of the rack. ycan cool over 35 kw per Rack ycompletely sealed rack yn+1 redundant variable speed fans yquiet operations yautomatic emergency door opening Open and Closed Architecture Systems as defined by ASHRAE yopen architecture systems utilizes cooling coils near the heat load either inside or outside the open server rack and use the room air volume as a thermal storage to ride through short power outages. yclosed architecture fully encloses the rack with the cooling coils inside. Other provisions are required for power loss ride through. For refrigerant-based systems, the Liebert XD system is designed to maximize cooling efficiency while avoiding the electrical hazards that may be present in a water-based system. The Liebert XD system can cool rack loads from 8 to 40 kw per rack in rooms 1200 sq ft or larger. (See Liebert XD Brochure SL-11265 for more details.) 7

VertivCo.com Vertiv Headquarters, 1050 Dearborn Drive, Columbus, OH, 43085, USA 2016 Vertiv Co. All rights reserved. Vertiv, the Vertiv logo and Vertiv Liebert DSE are trademarks or registered trademarks of Vertiv Co. All other names and logos referred to are trade names, trademarks or registered trademarks of their respective owners. While every precaution has been taken to ensure accuracy and completeness herein, Vertiv Co. assumes no responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions. Specifications are subject to change without notice. SL-17355 (R01/12)