series USER S MANUAL MICREX-F Personal Computer Loader Adapter <Type:FLT-ASFKA >

Similar documents
OPC-VG1-PG / PGo. PG Interface Card for FRENIC-VG. Instruction Manual

series FUJI PROGRAMMABLE CONTROLLER USER S MANUAL BUILT-IN HIGH-SPEED COUNTER FEH404

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

DC I/O Conversion Module FA-TB32XY

DC I/O Conversion Module

Appearance Size (mm) Power supply voltage Model (W H D) 100 to 240 VAC K3SC to 240 VAC

TOP - 1. Instruction Manual. Version 1.0 Produced in Jan. 2004

FEATURES FEATURES. Macro Function Usage Supports strong Visual Basic script language which includes more than 500 built-in functions.

JANOME DESKTOP ROBOT JR2000N Series. Operation Manual. <Setup> For Qualified Installer ONLY

High-precision Load Cell Unit <Type: NA0FA-LC1>

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

PLC-24V10AL(-PT/-TH) Quick Start Manual (Rev.1.10)

series USER S MANUAL Analog Unit FEH527d

RS232C/RS485 Data can be easily monitored by LAN

USB to RS232 Converter USB-013 (Rev3) User s Manual Ver. 1.2 HuMANDATA LTD.

FEATURES DESCRIPTION GENERAL SPECIFICATIONS

Programmable Controller Analog Terminal Block Conversion Module FA1-TBS40ADGN, FA1-TBS40ADDG, FA1-TBS40DAG User's Manual

Conductive Level Controller

Package Contents. GP Options (Made by Digital)

PROGRAMMABLE CONTROLLER. FP0 A/D Converter Unit. Technical Manual ARCT1F321E

RS-232C/485 Isolation Unit Installation Guide. Essential Safety Precautions WARNINGS

Handheld Reader Writer

GENERAL PRECAUTIONS GENERAL DESCRIPTION... 6

MODEL: R2K-1 SEN TRONIC AG. R2K Series

Safety Relay Unit (I/O Unit Type)

Solid-state Timer. Ordering Information. Miniature Timer with Multiple Time Ranges and Multiple Operating Modes H3YN- - Accessories (Order Separately)

Druck DPI 620 advanced modular calibrator

1. Safety Precautions (Read these precautions before use.)

Maximum Value for OEMs SM. NX70 Serial Communications Unit (SCU) User Manual

PFXGP4601TAD. Pro-face Xycom GP4000 PFXGP4601TAD

PFXGP4503TAD. Pro-face Xycom GP4000 PFXGP4503TAD

Appendix 3 Using NS-AL002 Converters

Solid-state Timer H3YN

USB Data Transfer Cable CA3-USBCB-01 Installation Guide

S8VE (60/90/120/180/240-W Models)

FX-USB-AW/FX3U-USB-BD. USER'S MANUAL USB Driver Installation Edition

POWER SUPPLY UNIT PSU-3

About the Manual. ST-3400 Series Installation Guide. Package Contents

EQUIPMENT OPERATION MANUAL

The following symbols are used to show dangerous operation or handling. Make sure you understand them before reading the guide.

Solid-state Timer. Ordering Information. Ultra-slim Timer for G2R Relay Socket. H3RN-jj. Accessories (Order Separately) Connecting Socket

Switch Mode Power Supply

CONPROSYS. 24VDC AC-DC Converter CPS-PWD-90AW User s Guide CONTEC CO., LTD.

Installation Sensing distance Connection Output configuration Operation mode NO Operation mode NC

8 Channel USB to RS485/422 Converter USB-402 User s Manual Ver. 1.0 HuMANDATA LTD.

TOS-SN-1 Extended Panel Operation Manual

Optional add-on cassette Attachment Instruction manual

Installation Manual INTELLIGENT SERVER. Model name: BMS-LSV6UL

Users Manual STP-103II. Thermal Printer Rev

About the Manual. ST-3300 Series Installation Guide. Package Contents

E2Q4 Square Proximity Sensor

FUJITSU SEMICONDUCTOR CONTROLLER MANUAL CM E FR20/30 SERIES DSU-FR20/30 EMULATOR MB HARDWARE MANUAL

PLP-300W14A Instruction Manual (Rev.2.20)

Data setting software MEXE02

EQUIPMENT OPERATION MANUAL

ELV12 Series. Instruction Manual

Programmable Relay ZEN V2 Units

FR-A8AR INSTRUCTION MANUAL

7032 Digital-Analog Multimeter

User s Manual. PCI Bus Expansion Adapter for PCI Bus PC-Slot EAD(PCI)BE PCI Bus Expansion Adapter for Low Profile PCI PC-Slot EAD(LPCI)BE

V-3000 Series Miniature Basic Switches

USER'S GUIDE FX-485ADP COMMUNICATION ADAPTER FX0N-485ADP COMMUNICATION ADAPTER

Timers. GT3W Series Dual Time Range Timers. 250V AC/150V DC Time Range. 1: 0.1sec to 6 hours, 3: 0.1sec to 300 hours

The following symbols are used to show dangerous operation or handling. Make sure you understand them before reading the guide.

NIR Moisture Analyzer KB-30

DISCLAIMER: All products, logos, brand names, or companies are trademarks or registered trademarks of their respective owners!

Analog Input/Output Modules

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

PIEZO FEEDER CONTROLLER

Automationdirect.com

SRT2-ROC08, SRT2-ROC16

Three-phase Phase-sequence Phase-loss Relay

MICREX-SX Series Renewal Tool Announcement of Release of MICREX-F Size I/O Module

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1

Setting method Indication Control Output Model method mode Thermocouple (with sensor burnout detection circuit)

Operation Manual WARNING. Be sure to read this Operation Manual before use. Universal Space Amusement Equipment Ltd.

Solid-state Timer. Ordering Information. Specifications. Miniature Timer Compatible with the MY Relay. Accessories. Time Ranges

Series IZH10. Handheld Electrostatic Meter. How to Order. Accessories and Option / Part Number for Individual Parts.

Thread length (overall length) material

User s Manual Model PBL100 Logic Probe IM E. 4th Edition

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

CM E FUJITSU SEMICONDUCTOR CONTROLLER MANUAL F 2 MC-16L/16LX EMULATION POD MB HARDWARE MANUAL

SIRIUS CAPACITOR MODULE User Manual. Model number: A-1.7C-M-SD-G Version 1.0; Release Date: April 2018

Line Interactive 1000VA/1400VA/2000VA Uninterruptible Power System

Ordering Information. Interface Converter K3SC. List of Models

B&W RearView Camera Installation & Operation

CONPROSYS. 24VDC AC-DC Converter CPS-PWD-30AW User s Guide CONTEC CO., LTD.

TOUCH SCREEN CONTROLLER for Air Conditioning Control System

OPERATING INSTRUCTION

Single-phase Voltage Relay

Preface. Copyright 1997, Digital Electronics Corporation MS-DOS and Windows 95 are registered trademarks of the Microsoft Corporation.

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

EC Series. Safety Guide

EX-RC1 Remote I/O Adapter

Analog Monitor Installation Manual

S82S (3/7.5-W Models)

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD

Hardware Operation Manual for CLE1000 H2K CLE1000 H2V

Phone: Fax: Web:

OPLC Installation Guide

Transcription:

series USER S MANUAL MICREX-F Personal Computer Loader Adapter <Type:FLT-ASFKA >

Safety Precautions Be sure to read the Safety Precautions thoroughly before using the product. Here, the safety precautions items are classified into Warning and Caution. Warning Caution : Incorrect handling of the device may result in death or serious injury. : Incorrect handling of the device may result in minor injury or physical damage. Even some items indicated by Caution may result in a serious accident. Both safety instruction categories provide important information. Be sure to strictly observe these instructions. Warning Never touch any part of charged circuits as terminals and exposed metal portion while the power is turned ON. It may result in an electric shock to the operator. Turn OFF the power before mounting, dismounting, wiring, maintaining or checking, otherwise, electric shock, erratic operation or troubles might occur. Place the emergency stop circuit, interlock circuit or the like for safety outside the PLC. A failure of PLC might break or cause problems to the machine. Do not connect in reverse polarity, charge (except rechargeable ones), disassemble, heat, deform, throw in a fire or short-circuit the batteries, otherwise, they might burst or take fire. If batteries have any deformation, spilled fluids, or other abnormality, do not use them. The use of such batteries might cause explosion or firing.

Safety Precautions Caution Do not use one found damaged or deformed when unpacked, otherwise, fire, failure or erratic operation might be caused. Do not shock the product by dropping or tipping it over, otherwise, it might be damaged or troubled. Follow the directions of the operating instructions when mounting the product. If mounting is improper, the product might drop or develop problems or erratic operations. Use the rated voltage and current mentioned in the operating instructions and manual. Use beyond the rated values might cause fire, erratic operation or failure. Operate (keep) in the environment specified in the operating instructions and manual. High temperature, high humidity, condensation, dust, corrosive gases, oil, organic solvents, excessive vibration or shock, might cause electric shock, fire, erratic operation or failure. Select a wire size to suit the applied voltage and carrying current. Tighten the wire terminals to the specified torque. Inappropriate wiring or tightening might cause fire, malfunction, failure or might cause the product to drop from its mounting. Contaminants, wiring chips, iron powder or other foreign matter must not enter the device when installing it, otherwise, fire, accident, erratic operation or failure might occur. Remove the dust-cover seals of modules after wiring, otherwise, fire, accident, erratic operation or failure might occur. Connect the ground terminal to the ground, otherwise, electric shock or erratic operation might occur. Periodically make sure the terminal screws and mounting screws are securely tightened. Operation at a loosened status might cause fire or erratic operation. Put the furnished connector covers on unused connectors, otherwise, erratic operation or failure might occur. Put the furnished terminal covers on the terminal blocks, otherwise, electric shock or fire might occur. Sufficiently make sure of safety before program change, forced output, starting, stopping or anything else during a run. Wrong operation might break or cause problems to the machine Engage the loader connector in a correct orientation, otherwise, an erratic operation might occur. Before touching the PLC, discharge any static electricity that may have been collected on your body. To discharge it, touch a grounded metallic object. Static electricity might cause erratic operation or failure. Be sure to install the electrical wiring correctly and securely, observing the directions of the operating instructions and manual. Wrong or loose wiring might cause fire, accident or failure. When disengaging the plug from the outlet, do not pull the cord, otherwise, break of cable might cause fire or failure. Do not attempt to change system configurations (such as installing or removing I/O modules) while the power is ON, otherwise, erratic operation or failure might occur. Do not attempt to repair the module by yourself, but contact your Fuji Electric agent. When replacing the batteries, correctly and securely connect the battery connectors, otherwise, fire, accident or failure might occur. Do not remodel or disassemble the product, otherwise, failure might occur. Follow the regulations of industrial wastes when the device is to be discarded. The modules covered in these operating instructions have not been designed or manufactured for use in equipment or systems which, in the event of failure, can lead to loss of human life. If you intend to use the modules covered in these operating instructions for special applications, such as for nuclear energy control, aerospace, medical or transportation, please consult your Fuji Electric agent. Be sure to provide protective measures when using the module covered in these operating instructions in equipment which, in the event of failure, can lead to loss of human life or other grade results. External power supply (such as 24 V DC power supply) which is connected to DC I/O should be strongly isolated from AC power supply, otherwise, accident or failure might occur. (Use of EN60950 conforming power supply is recommended.)

Preface Thank you for purchasing FUJI programmable controller MICREX-F series. This user s manual explains the hardware specifications of personal computer loader adapter (Type:FLT-ASFKA) to connect personal computer loader and MICREX F series. Read this manual carefully to ensure correct operation. When using modules or peripheral devices, be sure to read the corresponding user s manuals listed below: Title Manual No. Contents MICREX-F series for personal computer software package windows version FEH147 Explains operations of MICREX-F PLC Programmer MICREX-F series <Instructions> FEH160 Explains the specification of All MICREX-F series memory, instructions, system definitions. MICREX-F series <Communications> FEH161 Explains the specification of MICREX-F series T-link/ P-link/ PE-link MICREX-F F55 series <Hardware> FEH150 Explains the hard specification of F55 series. MICREX-F F70/70S series <Hardware> LEH946 Explains the hard specification of F70/70S series. MICREX-F F120S/140S/150S series <Hardware> LEH913 Explains the hard specification of F120S/140S/150S series. *In addition to the above manuals, the following Fuji Electric Systems Co., Ltd. site offers various manuals and technical documents associated with MICREX-F. URL http://www.fesys.co.jp/eng/ Notes 1. This manual may not be reproduced in whole or part in any form without prior written approval by the manufacturer. 2. The contents of this manual (including specifications) are subject to change without prior notice. 3. If you find any ambiguous or incorrect descriptions in this manual, please write them down (along with the manual No. shown on the cover) and contact FUJI. * Microsoft and Windows are registered trademarks or trademarks of Microsoft Corporation of the U.S.A. * Pentium is a registered trademark or trademark of Intel Corporation of the U.S.A.

Revisions *Manual No. is shown on the cover. Printed on *Manual No. Revision contents Dec. 2008 FEH147-1 First edition

Contents Preface Revisions Contents Section 1 General 1-1 Connection Configuration of Personal Computer Loader... 1-1 Section 2 Specifications 2-1 General Specifications... 2-1 2-2 Communication Specifications... 2-2 2-3 Names and Functions... 2-3 2-3-1 Names... 2-3 2-3-2 Functions... 2-3 2-4 Dimensions... 2-5 Section 3 Online Operations 3-1 Setting Communication Port of Peronal Computer Loader... 3-1 3-2 Setting Loader Adapter... 3-2 3-3 Connecting Personal Computer Loader and PLC Setting... 3-3 3-3-1 In Case of Using USB Port of Personal Computer... 3-3 3-3-2 In Case of Using RS-232C Port of Personal Computer... 3-3 3-4 Installation of USB Driver... 3-4 3-4-1 Installing USB Driver... 3-4 3-4-2 How to Confirm COM Port Number... 3-8 3-4-3 How to Change COM Port Number...3-10

Personal Computer Loader Adaptor FLT-ASFKA Personal Computer Loader Adaptor FLT-ASFKA Section 1 General Loader adapter (type:flt-asfka) equips RS-232C and USB port. You don't need to connect an external converter for USB <-> RS-232C even though your personal computer doesn't have RS-232C port. 1-1 Connection Configuration of Personal Computer Loader (1) How to use USB port of personal computer <Preparation> Personal computer loader (personal computer + MICREX-F PLC Programmer) Loader adapter (loader cable is attached with the product) USB cable (A-B Type) available at market USB driver (download from our homepage) MICREX-F USB cable (A-B Type) RS232C LOADER USB PWR MODE SET MICREX-F Personal computer loader MICREX-F PLC Programmer Loader adapter Type:FLT-ASFKA Loader cable Type:FLC012A(1m) *Attached with FLT-ASFKA It is needed to install USB driver in every USB port of using personal computer. Download USB driver for loader adapter from our technical information page. Access to the following website. USB driver is set in [Software libraries] of [Programmable controllers]. http://www.fesys.co.jp/eng/ Note) it is required to register as a member of our technical information to download. (2) How to use RS-232C of personal computer <Preparation> Personal computer loader (personal computer + MICREX-F PLC Programmer) Loader adapter (loader cable is attached with the product) RS-232C cross cable D-sub9Pin Type: female - female (available at market) RS-232C Cable (D-sub9-Pin cross) MICREX-F RS232C LOADER USB PWR MODE SET MICREX-F Personal Computer Loader MICREX-F PLC Programmer Loader adapter Type: FLT-ASFKA Loader cable Type:FLC012A(1m) *Attached with FLT-ASFKA 1-1

Section 2 Specifications 2-1 General Specifications Title Specifications Operation ambient temperature Storage temperature 0to50-25 to70 Physical environment conditions Relative humidity Pollution degree 2 Corrosion immunity 20 to 95%RH, no condensation. Transport condition:5 to 95%RH, no condensation Free from corrosive gases. No stained with organic solvent. Corrosive gas Operating altitude Isolation resistance Dielectric strength Insulation resistance Internal Current consumption Free from corrosive gases. 2000m or less above sea level Transport condition: 70kPa (equivalent to3000m above sea level) or more Photocoupler 445V AC/ minute (between T-link and RS-232C or USB connector) 10M or more with 500V DC megger (between T-link and RS-232C or USB connector) 5VDC, 270mA or less (supplied from PLC via loader cable) Installation conditions Mass Structure Cooling methods Tabletop type Natural air cooled Approx.140g Outside dimensions W120XH72XD33mm (described in Chapter 2-4) 2-1

Section 2 Specifications 2-2 Communication specifications Title Between Personal computer loader and the adapter Between the adapter and PLC RS-232C connection USB connection Connection distance 15m 2m 1m (Attached loader cable type: FLC 012A using) *It is possible to extend maximum 5m by using optional loader cable. Type: FLC 011A using 5m Type: FLC 010A using 3m Transmission method RS-232C USB2.0 Full Speed T-link Data bit 7/8 bits - - Parity Even/ odd/ none - - Baud rate (bps) 300/600/1200/2400/4800- /9600/19200/38400 - - 2-2

Section 2 Specifications 2-3 Names and Functions 2-3-1 Names 4)RS-232C connector 3)PLC connector Left side 5)Connector selection switch <FRONT> Right side RS232C Personal Computer Loader Adaptor FLT-ASFKA LOADER USB PWR MODE SET 6)USB connector(type-b 2)Operating setting switch 1)Status indication LED 2-3-2 Functions (1) Status indication LED It turns on the light when the adapter is supplied power from PLC. (Green) (2) Operation setting switch It is the switch for setting connection with personal computer loader. ON Baud rate Parity biteven/odd) ON:even OFF:odd Parity bit ON:provided (provided/ not provided) OFF:not provided Data bit lengthon: 7bits OFF:8 bits Setting mode Operation mode Personal computer loader mode Remote loader mode Not Used Not Used Baud rate 300 600 1200 2400 4800 9600 19200 38400 *It is set to personal computer loader mode, baud rate: 19200, data length: 8bits, and no parity at factory shipment. *It doesn't reflect setting the contents even if it is changed during online. It reflects them upon energization to the adapter. We recommend setting the switch during power off. If the setting is changed during power on, you need to reset this adapter by un-plug and plug in loader cable. 2-3

Section 2 Specifications (3) PLC connector Join the loader cable to connect between the adapter and PLC (MICREX-F series). The loader cable is attached to the product. Type: FLC 012A (1m) Inch screw (5) Connector selection Switch (6)USB connector(type-b (4)RS-232C connector (Male) (4) RS-232C connector Join the RS-232C cable to connect the adapter and personal computer loader. The adapter is D-sub9 pins male type. *Use cross cable of commercial D-sub 9-pin for RS-232C cable. 9 6 PIN No. Function Direction of Signal Adapter Personal computer Description 5 1 1 CD Carrier detection 2 RD Receive data 3 SD(TD) Send data 4 ER(DTR) Data terminal ready 5 SG - Signal ground 6 DR(DSR) Data set ready 7 RS(RTS) Request to send 8 CS(CTS) Clear to send 9 RI(CI) Call indication (5) Connector selection switch Select a connector which connects the adapter and personal computer loader. It connects to RS-232C when you switch it to RS-232C side, and connects by USB cable when you switch it to USB side. *It is set to RS-232C at factory shipment. (Note) If the switch is changed during online, communication is cut off and causes error. (6) USB connector (TYPE-B) Join USB cable to connect the adapter and personal computer loader. Use commercial A-B type USB cable. 2-4

Section 2 Specifications 2-4 Dimensions (Unit:mm) 7 114 33 RS232C Personal Computer Loader Adaptor FLT-ASFKA LOADER 72 USB PWR MODE SET 2-5

Section 3 Online Operations 3-1 Setting Communication Port of Personal Computer Loader (1)Start up MIREX-F PLC Programmer.Select [Option] - [Communications] from menu bar, and the [Communication setup] dialogue is displayed. (2)Select a COM port number of communication port which you connect loader adapter. (3) Click the [PLC comm Port Properties] button, then the following dialogue is displayed. (Note) When you click the the [PLC Comm Port Properties] button, if communication port setting is not available, the following picture is displayed. It is possible to check what COM port is assigned to using port by [Device Manager]. Set Baud rate, Data bits, Parity to fit in operation setting switch. Stop bits: 1 and Flow control: None should not be changed. 3-1

Section 3 Online Operations 3-2 Setting Loader Adapter Set the switch to fit in communication port of personal computer loader. This setting is also needed when USB port is used. <Setting expample In case of Baud rate:19200 bit/ second, Data bits: 8, Parity: None> * Read chapter3-1 to know how to set the communication port of personal computer loader. <Connector selection switch> Set connector selection switch to using communication port. RS-232C connector USB connector In case of using USB, switch it to USB connector side. In case of using RS-232C, switch it to RS-232C connector side. Operation setting switch RS232C Personal Computer Loader Adaptor FLT-ASFKA LOADER ON USB PWR MODE SET Baud rate Mode setting Parity biteven/odd) ON:even OFF:odd Parity bit ON:provided (provided/ not provided) OFF:not provided Baud rate 300 600 1200 Operation mode Personal computer loader mode Data bit lengthon:7bits OFF:8bits 2400 4800 Remote loader mode 9600 Not Used 19200 Not Used 38400 3-2

Personal Computer Loader Adaptor FLT-ASFKA Personal Computer Loader Adaptor FLT-ASFKA Section 3 Online Operations 3-3 Connect Personal Computer Loader and PLC 3-3-1 In case of using USB port of personal computer MICREX-F USB cable (A-B Type) RS232C LOADER USB PWR MODE SET MICREX-F Personal computer loader MICREX-F PLC Programmer Loader adapter Type:FLT-ASFKA Loader cable Type:FLC012A(1m) *Attached with FLT-ASFKA 3-3-2 In case of using RS-232C port of personal computer RS-232C Cable (D-sub9-Pin cross) MICREX-F RS232C LOADER USB PWR MODE SET MICREX-F Personal Computer Loader MICREX-F PLC Programmer Loader adapter Type: FLT-ASFKA Loader cable Type:FLC012A(1m) *Attached with FLT-ASFKA 3-3

Section 3 Online Operations 3-4 Installation of USB Driver In case of using USB port of personal computer, it is needed to install USB driver for loader adapter. There are two kinds of drivers for loader adapter: "USB Serial Converter" and "USB serial Port." It is needed to install both of them. 3-4-1 Installng USB driver (1) Connect loader adapter to energized PLC loader connector. Status indication LED lamp on the loader adapter will turn on. Connect a cable to USB connector of personal computer. The following dialogue is displayed when personal computer recognizes a loader adapter as USB device. (2) Select "Install from a list or specific location," and click the [Next] button. Then the following dialogue is displayed. Check off on the "Include this location in the search" box. 3-4

Section 3 Online Operations (3) Click the [Browse] button, select the folder in which stores a driver file, and click the [OK] button. The picture on left side is an example that driver soft is stored in USB serial converter driver folder. (4) When you click the [Next] button, it starts to install "USB serial Converter." Then, the following warning dialogue is displayed. Click the [Continue anyway] button to continue to install. (5) Continue to install. Then when install finishes, the following is displayed. 3-5

Section 3 Online Operations (6) When you click the [Finish] button, it starts to install "USB serial port" driver, and the following dialouge is displayed. Then click the [Next] button. (7) Select "Install from a list or specific location," and click the [Next] button. Then the following dialogue is displayed. Check off on the "Include this location in the search" box. 3-6

Section 3 Online Operations (8) When you click the [Next] button, it starts to install "USB serial Converter." Then, the following warning dialogue is displayed. Click the [Continue anyway] button to continue to install. (9) Continue to install. Then when install finishes, the following picture is displayed. 3-7

Section 3 Online Operations 3-4-2 how to confirm the COM port number This is the way to confirm what COM port is assigned to the installed communication port. Here, it explains how to do by WINDOWS-XP (1) Right-click on [My computer] on the desk top screen, and select [Properties] from the menu. Then, the [System properties] dialogue is displayed. Click the [Hardware] tab, so the following screen is displayed. *If the [My computer] icon is not on desktop, go to WINDOWS [Start ] menu. Then, right click on [My computer], and select [Properties] from the menu, then [System properties] is displayed. 3-8

Section 3 Online Operations (2)Click the [Device Manager] button, then it is able to confirm the assign status such as the following picture. COM port number is displayed here The installed driver The installed driver 3-9

Section 3 Online Operations 3-4-3 How to change the COM port number COM port number of personal computer loader is from COM 1 to COM 9. If it is assign to COM 10 or more even though you followed the above operations, change the COM port number by following step. (1) Double-click [USB serial port], then [Properties] dialogue is displayed. Double-click here (2) [USB serial Port properties] is displayed. Select the [Port Setting] tab, and click the [Advanced] button. (3) The [Advanced] dialogue is displayed. Select the available COM port number among COM 01 to COM 09, and click the [OK] button. 3-10

Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome, Shinagawa-ku, Tokyo, 141-0032,Japan Phone: +81-3-5435-7280 Fax: +81-3-5435-7425 URL http://www.fesys.co.jp/eng/