A. Both Node A and Node B will remain on line and all disk shelves will remain online.

Similar documents
EXAM - NS NetApp Certified Implementation Engineer - SAN, Clustered Data ONTAP. Buy Full Product.

NS0-506 Q&As NetApp Certified Implementation Engineer - SAN, Clustered Data ONTAP

Netapp Exam NS0-506 NetApp Certified Implementation Engineer - SAN, Clustered Data ONTAP Version: 6.0 [ Total Questions: 65 ]

NS Number: NS0-507 Passing Score: 800 Time Limit: 120 min File Version: NS0-507

SAN Configuration Guide

Actual4Test. Actual4test - actual test exam dumps-pass for IT exams

SAN Administration Guide

Exam Questions ns0-507

NS0-171.network appliance

SAN Implementation (SANIW)

SAN Administration Guide

ATTACHMENT A SCOPE OF WORK IMPLEMENTATION SERVICES. Cisco Server and NetApp Storage Implementation

Clustered Data ONTAP 8.3

FC Configuration for ESX Express Guide

PASS4TEST. IT Certification Guaranteed, The Easy Way! We offer free update service for one year

iscsi Configuration for ESXi using VSC Express Guide

ns0-157 Passing Score: 700 Time Limit: 120 min File Version: 1.0

Technical Brief: How to Configure NPIV on VMware vsphere 4.0

Windows Host Utilities Installation and Setup Guide

Question: 1 You have a Cisco UCS cluster and you must recover a lost admin password. In which order must you power cycle the fabric interconnects?

Copy-Free Transition Guide

FC Configuration for Windows Express Guide

Clustered Data ONTAP 8.2

Windows Unified Host Utilities 7.0 Installation Guide

Fibre Channel and iscsi Configuration Guide for the Data ONTAP 8.0 Release Family

Exam Questions NS0-157

Windows Unified Host Utilities 7.1 Installation Guide

Data Protection Guide

Netapp Interoperability Matrix

Actual4Test. Actual4test - actual test exam dumps-pass for IT exams

Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere

VMware vsphere on NetApp (VVNA)

Windows Unified Host Utilities 7.0 Using Windows Hosts with ONTAP Storage

iscsi Configuration for ESX Express Guide

NAS for Server Virtualization Dennis Chapman Senior Technical Director NetApp

Active System Manager Release 8.2 Compatibility Matrix

Data Protection Guide

Clustered Data ONTAP 8.2

NetworkAppliance NS NetApp Certified Data Administrator, ONTAP.

UCS Direct Attached Storage and FC Zoning Configuration Example

VersaStack for Data Center Design & Implementation (VDCDI) 1.0

ONTAP 9 Cluster Administration. Course outline. Authorised Vendor e-learning. Guaranteed To Run. DR Digital Learning. Module 1: ONTAP Overview

UCS Engineering Details for the SAN Administrator

ITBraindumps. Latest IT Braindumps study guide

Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere

Copy-Based Transition Guide

Configuring and Managing Virtual Storage

Availability for the Modern Data Center on FlexPod Introduction NetApp, Inc. All rights reserved. NetApp Proprietary Limited Use Only

NetApp. Number: NS0-156 Passing Score: 800 Time Limit: 120 min File Version: 1.0.

Oracle Database Consolidation on FlashStack

Direct Attached Storage

NetApp Clustered Data ONTAP 8.2

DCNX5K: Configuring Cisco Nexus 5000 Switches

Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere

Cisco CCIE Data Center Written (Beta) Download Full Version :

7-Mode Transition Tool 2.2

VMware vsphere with ONTAP

SnapCenter Software 2.0 Installation and Setup Guide

FlexPod Datacenter with VMware vsphere 6.5, NetApp AFF A-Series and Fibre Channel

Windows 2012 NPIV on UCS Configuration Example

MAX Data 1.1 Installation and Setup Guide. November _A0

iscsi Configuration for Windows Express Guide

NS0-158 netapp. Number: NS0-158 Passing Score: 800 Time Limit: 120 min.

Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere

FlexArray Virtualization

Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere

NetApp AFF A700 Performance with Microsoft SQL Server 2014

EMC Unity Family EMC Unity All Flash, EMC Unity Hybrid, EMC UnityVSA

NetApp Deployment Guidelines and Storage Best Practices for Windows Server 2016

Downpour II: Converged Infrastructure with VMware vsphere 5.5 Solution

vsphere 6.0 with HP ProLiant Gen9 Servers, OneView, 3PAR, Cisco Nexus 5600 and Brocade 6510 Deployment Guide

Data ONTAP DSM 4.1 for Windows MPIO Installation and Administration Guide

Exam Questions NS0-180

Express Configuration

FlexPod Datacenter with Oracle Real Application Clusters 12c Release 1 and NetApp All Flash FAS

vsphere 6 on NetApp MetroCluster 8.3

Microsoft Iscsi Software Initiator User's Guide Server 2012

OnCommand Unified Manager 6.1

Service Profiles and Templates

NS0-180 netapp

Installation and Cluster Deployment Guide for VMware

NetApp Block Access Management using Open Interfaces

DataONTAPDSM3.5forWindows MPIO Release Notes

PrepAwayExam. High-efficient Exam Materials are the best high pass-rate Exam Dumps

NS0-191 netapp. Number: NS0-191 Passing Score: 800 Time Limit: 120 min.

Host and storage system rules

OnCommand Unified Manager Installation and Setup Guide for Use with Core Package 5.2 and Host Package 1.3

UCS-ABC. Cisco Unified Computing System Accelerated Boot Camp. Length: 5 Days. Format: Lecture/Lab. Course Version: 5.0. Product Version: 2.

Deployment Guide: Network Convergence with Emulex OneConnect FCoE CNA and Windows Server Platform

Clustered Data ONTAP Administration (DCADM)

Fibre Channel Zoning

SnapMirror Configuration and Best Practices Guide for Clustered Data ONTAP

Nimble Storage SmartStack Getting Started Guide Cisco UCS and VMware ESXi5

DataONTAPDSM4.0.1forWindows MPIO Installation and Administration Guide

UCS SAN Troubleshooting

Configuring Server Boot

Data Protection Guide

How to Configure NPIV in a Microsoft Hyper-V Environment

Exam Questions NS0-156

Virtual Storage Console 6.1 for VMware vsphere

Transcription:

Volume: 75 Questions Question No: 1 On a FAS8040, which port is used for FCoE connections? A. e0m B. e0p C. 0a D. e0h Answer: D Question No: 2 Click the Exhibit button. Referring to the diagram shown in the exhibit, what will happen if PDU-B fails? A. Both Node A and Node B will remain on line and all disk shelves will remain online.

B. Both Node A and Node B will remain on line, but all disk shelves will immediately lose power and become inaccessible. C. Both Node A and Node B will immediately lose power and become inaccessible. D. Node A will immediately lose power and become inaccessible. Node B will remain on line. Question No: 3 Hosts and switches are connected to a FAS8040. Multiple FC-enabled SVMs have been created, and LUNs have been mapped to multiple hosts. During failover testing, one of the hosts lost connectivity to its LUNs. What needs to be examined? A. FAS8040 ALUA configuration B. host multipath settings C. xhost iscsi timeout values D. switch NPIV settings Question No: 4 Click the Exhibit button. Based on the exhibit, you are configuring a 4-node cluster with an iscsi LIF ob each node. You connect using the first LIF from a Windows Server 2012 host. How would you add the other three LIFs?

A. Use the MCS button. B. Use the Devices button. C. Use the Add session button. D. Wait and then press the Refresh button until the other sessions appear. Answer: C Question No: 5 You have a 4-node FAS8040 cluster licensed for FCP and iscsi. Each node has both FC and iscsi LIFs. One of your Windows 2012 Servers has a single 8Gb FC port and a single 10 Gb Ethernet port with

switched connectivity to the FC and Ethernet ports on the cluster. You need to use both ports on the host for multipath access to a LUN on the NetApp cluster. What will accomplish this task? A. NetApp Data ONTAP DSM for Windows MPIO B. FCoE HBA C. iscsi HBA D. native Windows MPIO Question No: 6 A customer has a clustered Data ONTAP solution and needs to connect several Windows 2012 servers using iscsi for LUN access. Before the LUN can be seen, what must be configured on the host? A. the LUN partitioning B. the Host Utilities Kit C. the iscsi software initiator D. the HBA queue depth Answer: B Question No: 7 You have executed the following FC configuration workflow: 1. Verify IMT supported configuration. 2. Install VSC for VMware vsphere on a Windows Server. 3. Add the storage cluster to VSC and set recommended values. 4. Update host HBA firmware and BIOS. 5. Provision the LUN. 6. Manually create an igroup and add the host WWPNs into it. 7. Map the LUN to the igroup. 8. Create datastore and its containing LUNS and volumes. In step 8, you are not able to see the LUNs you provisioned on your storage controller. When you run igroup show you see the ESX host's initiators; however, they are listed "not logged in".

What is the problem? A. You need to configure ALUA. B. The LUN was not put on line. C. The LUN type is not set to type VMware. D. You need to configure zoning. Answer: D Question No: 8 Click the Exhibit button. You have a 2-node data ONTAP 8.3 cluster. Based on the exhibit, which change must be made to make svm1 conform to iscsi best practices? A. The iscsi LIFs must be moved to a VLAN higher than 1024. B. An iscsi LIF must be added to node cl01-02. C. The Target Alias must be modified to match the Target Name. D. The iscsi LIFs must be moved to a physical interface; iscsi LIFs are not supported on top of an ifgrp.

Answer: C Question No: 9 Which three environmental or physical requirements need to be met when designing a SAN solution? (Choose three.) A. rack space B. cooling C. clustered Data ONTAP version D. IOPS E. power, C, D Question No: 10 You have a large, heterogeneous SAN environment. You are asked to gather information for all hosts, HBAs, switches, and storage. You are also told that you must collect this information over network protocols without agents. Which two NetApp tools allow you to perform this task? (Choose two.) A. OnCommand Insight B. OnCommand Report C. OnCommand Unified Manager D. nsanity Answer: B, D Question No: 11 Which information-gathering command should you use to gather logs for troubleshooting switch information for your Brocade switches? A. cfgshow

B. fabricshow C. configshow D. supportsave Answer: B Question No: 12 You are asked to migrate a SAN LIF to a node that was recently added to your cluster. The following CLI command was provided to you to complete the migration: network interface modify-vserver svm1 -lif lif1 -home -node cl01-04 -home port 6a Which step is missing? A. All hosts connecting to the controller through lif1 must be shut down. B. The LIF must first be added to a portset. C. Your zoning must be updated on the upstream switch. D. The LIF must be put in a status-admin down state. Question No: 13 You are verifying multipathing from the host to the storage controller. Which three components should you verify? (Choose three.) A. Verify that all switch ports connected to the hosts and storage devices are online using the vendor's GUI. B. Verify that both FC HBA ports in the host are on line using the HBA vendor's GUI. C. Verify that the FC HBAs WWNN's are in the igroup in the SVM. D. Verify that the SVM's LIFs being used for multipathing are attached to the correct same physical FC port. E. Verify that the storage controller FC target ports status are on line with the switch port showing the FC switch to which they are connected.

, D, E Question No: 14 Click the Exhibit button. Referring to the exhibit, which entry is appropriate to add to a zone on the FC switch? A. 20:05:00:a0:98:29:18:76 B. 20:10:00:a0:98:29:18:76 C. 20:14:00:a0:98:29:18:76 D. 50:10:00:a0:98:29:18:76 Question No: 15 Click the Exhibit button. A customer is provisioning storage for two ESXi hosts using FCoE with CNA adapters. The customer mapped the LUN to the igroup shown in the exhibit. After scanning for new devices, the LUN is only seen

by one of the ESXi hosts. What caused the problem? A. One of the hosts is added in the igroup via iscsi IQN. B. The igroup protocol needs to be configured as FCP. C. The switch zoning configuration does not include the correct initiators. D. The LIFs are not on their home ports. Question No: 16 An administrator wants to provide isolation among physical devices connected to the same FCP fabric. Which Cisco switch feature accomplishes this task? A. VSAN B. FSIP C. LUN masking D. logical domains Question No: 17 You are creating a logical diagram for an FCP SAN solution. You need to show connectivity between which three sets of components? (Choose three.) A. management port and ACP cabling B. inter-cluster network ports and hosts C. hosts and FCP switches D. hosts and FCoE switches E. FCP switches and storage controller

Answer: B, D, E Question No: 18 When designing a new SAN solution, which three components should be verified with the IMT? (Choose three.) A. the connection protocol B. the patch panel make and model C. host OS type and version D. the type of Ethernet switch E. the clustered Data ONTAP version Answer: C, D, E Question No: 19 Which two port personality combinations are valid for the on board UTA2 ports on a FAS8040 controller? A. e0e/0e - fc e0f/0f - fc e0g/0g - cna e0h/0h - cna B. e0e/0e - fc e0f/0f - cna e0g/0g - fc e0h/0h - cna C. e0e/0e - fc e0f/0f - fc e0g/0g - fc e0h/0h - cna D. e0e/0e - cna