Version 1.1. User's Manual

Similar documents
Contents Overview... 3 Features... 4 Applications... 4 Specifications... 5 Packing... 6 Appearance... 7 Front Panel... 7 Rear Panel...

Atrie WireSpan 620. User's Manual

AREA CODE CHANGE. Please note that the area code for Paradyne Corporation in Largo, Florida has changed from 813 to 727.

USER MANUAL. G.shdsl+ modem with G.703 interface TAHOE 671 FREEDOM OF COMMUNICATION

xdsl Bridge WireSpan 5100B Installation Guide ATRIE TECHNOLOGY INC. (Version 1.00)

Modular E1 or Fractional E1 Access Unit. Dial-out for alarm report The E1 main link can be supplied with the following options:

F8008. Fiber Modem for up to 4E1 /8E1 +RS232+Ethernet. + optional V.35/QFXS/QFXO

USER MANUAL EOe-1. 10/100Base Ethernet over G.703 Unframed E1

FCD-E1, FCD-T1 E1/T1 or Fractional E1/T1 Access Units

Revision: 2.0. User's Manual

FCD-E1LC, FCD-T1LC Managed E1/T1 or Fractional E1/T1 Access Units

LOOP-IP 6100 Series High Speed Ethernet Interface Unit Users Manual for: Loop-IP 6100-DS3 Loop-IP 6100-DS3R Loop-IP 6100-E3 Loop-IP 6100-E3R

G.SHDSL NTU with Fixed Serial Interfaces

ASMi-52. 2/4-Wire SHDSL Modem FEATURES

F8016. Fiber Modem for up to 4E1 /8E1/12E1/16E1 + RS232+Ethernet+ optional V.35/QFXS/QFXO

FE1&10/100BASE-T Bridge

ISO 9001:2000 Certified Company

This document will show you how to set up the Hotwire 6205 ADSL Modem, and how to customize its configuration to get the most out of this product.

T3 Interface Converters

E1/10&100Base-T Bridge (VLAN)

Protocol/interface converter series

Loop-O 9300 Fiber Optical Mux

LA-140. Advanced ATM IAD FEATURES

Serial Communication Converters & Adapters Instruction Manual

FCD-E1E Managed E1 and Fractional E1 Access Device

Installing the Cisco 2524 and Cisco 2525 Routers

Serial Communications Accessories SITRANS RD200/300. Operating Instructions 05/2013 SITRANS

VDTU2-B110 VDSL2 LAN Extender

Product Documentation on the World Wide Web

DATA CONNECT ENTERPRISE

Overview of the Cisco 2524 and Cisco 2525 Routers

WIRESPEED ADSL MODEM (MODEL 2000) User Guide

MODEL DSU Kbps Rack Mount CSU/DSU OPERATOR S MANUAL. 280 I-80 West Exit 1 PO Box 1330 Verdi NV 89439

Wiring Section 3-3. NQ-Series communication ports support various types of (serial) communication.

VPN Routers. OnSite 2800 Series. Quick Start Guide

ERM-Mux/Plus. 4U, 10 I/O Slot Data, Ethernet, Voice E1 Managed Multiplexer. E1 Access Multiplexer. ERM-Mux/Plus.

FE1/10&100Base-T Bridge

Conitel ASYNC Adapter

4xT1/E1 i nline probe ASE With LinkSafe capabilities

E1/T1 Rate Converters

ASMi-52 2/4-wire SHDSL Modem/Multiplexer

USER MANUAL E1U-ET100. Ethernet over Unframed E1 Bridge Line Card For ERM01

GYM Bilgi Teknolojileri

Multiplexer FMUX/SAT. 4 x E1 ports V.35/RS-530/RS-449 link interface in codirectional mode. Installation and Operations Manual

RC702-FX Ethernet over SDH User Manual

Product Documentation on the World Wide Web

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

RS-232 Industrial Media Converter

isap5100 STM1/E1, Data, Ethernet, Voice Managed Multiplexer (4U)

Optical Multiplexer. Quick Start Guide

RC905-EE1. Ethernet to E1 Interface Converter (REV.B) User Manual

2/4-wire SHDSL Modem/Multiplexer

ALIANT OMMUNICATIONS. VCL-MegaConnect-Jr. 16 Port E1/T1 Mixed Configuration DACS and Interface Converter

Product Documentation on the World Wide Web

Leased-Line Extenders over IP

Installing the Cisco AS5400XM Universal Gateway

IPM-1SE Quick Start Guide

G.SHDSL NTU DECEMBER 2006 LB510A

Multiplexer FMUX / 16E1. 16 E1 Channels. Installation and Operation Manual. Document Version: 2.2E / Cronyx

Installing the Cisco ATA

F /100Mbps Ethernet to 8E1 Converter. Standalone/Module/Chassis User Manual

Installation of the POTS splitter card requires the following steps: Determining the cables you need. Installing the POTS splitter chassis

ASMi-54L SHDSL.bis Modem

F5-45x3/85x3 10/100Mbps Ethernet to 4E1/8E1 Converter User Manual

ET100/NRZ. Ethernet WAN Bridge. 10/100Base-TX Ethernet over NRZ

INSTALLATION and OPERATION MANUAL

RS-232 Fiber Link Card System

RTS ISDN 2002 System. Operator Manual Software Description

Serial Data DIN Fiber Link System

IPmux-1E. TDMoIP Gateway FEATURES

Frame Relay Cabling This section describes the cabling and connector pinouts for the Frame Relay cards.

16 x E1 G x Ethernet optical multiplexer

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

ASYNC Sharing Unit TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...5 SECTION 3 - INSTALLATION...7

TC1900 "QUICK TALK" RS-232 or Fiber Telephone Extender User's Manual

V C ALIANT OMMUNICATIONS. VCL-4 E1 + Ethernet PDH Optical Multiplexer. Data Sheet U.K. INDIA U.S.A. Valiant Communications (UK) Ltd

MARKET SEGMENTS AND APPLICATION

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD

ASYNC Sharing Unit TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...5 SECTION 3 - INSTALLATION...7

ASMi-54 SHDSL.bis Modem

VCL-CB RION. Intelligent E1 Channel Bank ORION TELECOM NETWORKS INC. Product Brochure & Data Sheet TELECOM NETWORKS. Headquarters: Phoenix, Arizona

UT3620 Triple NT1 Installation Guide

Preparing to Install the Cisco AS5350XM Universal Gateway

Installing the DS1-28/DS3-EC1-3 and DS1-84/DS3-EC1-3 Cards in the Cisco ONS MA

Datasheet. RC3000E Multi Service Access Node. Chassis. Uplink Cards. Specification. Downlink Cards. Raisecom Technology Co., Ltd.

16E1 + 1Ethernet Fiber Optical Multiplexer

Moxa TCC-100 Series Hardware Installation Guide

AMX-1344 Access DCS-MUX

F1000 User's Manual. (Version: V1.01)

Product Documentation on the World Wide Web

USER MANUAL. MODEL 1052 idsl Modem with RS-232 Interface. An ISO-9001 Certified Company SALES OFFICE (301) TECHNICAL SUPPORT (301)

The modems are made in industrial 108mm wide aluminium housing for DIN rail mounting. UCM RS232 interface

Flexible multiplexer E1XL

DS-1H05 Ethernet-over-Coax Extender. User Manual

MicroConverter G.704

ASMi-54L. Data Sheet. SHDSL.bis Modem

Cisco ONS CL Shelf Assembly Hardware

PCI Express 4-Port Industrial Serial I/O Cards

Loop-O9330 Fiber Optical Mux

FOMi-40 Fiber Optic Modem with Remote Management

Transcription:

Version 1.1 User's Manual

Contents Overview...3 Features...4 Applications...4 Specifications...5 Packing...6 Appearance...7 Front Panel...7 Rear Panel...8 Important Safety Instructions...9 Installation... 11 Hardware Setup...12 Point-to-point Operation...14 Console Operation...15 Console Operation / Configuration...16 Cables...20 Version History V1.0 released May 7, 2001 V1.1 released September 24, 2001 firmware 1.14, supports connection to datacom unit 1 Version 1.1

2 Version 1.1

Overview The SDSL with G.703 Fractional E1 interface is a data access Channel Service Unit modem with the latest multi-rate HDSL (High-speed Digital Subscriber Line) technology offering both long range and high speed data transmission with Nx64 rates from 128Kbps up to 2048Kbps. The transmitting data rate may be adapted for the best "rate vs. range" performance for efficient and stable data transmission. The uses the 2B1Q line code with echo cancellation to transmit its high data rate over a single twisted pair of telephone wires without being affected by bridge taps or mixed cable links. It also provides high immunity to background noise and enables transmission over multiple pair cables. 3 Version 1.1

Features High speed SDSL transport over single twisted Copper pair telephone lines 2B1Q line code Symmetrical Multi-rate Nx64 data transmission from 128Kbps to 2048Kbps G.703 E1 operates from recovery (E1 at CO), or loop recovery (E1 at RT) timing modes Simple operation Low power consumption Transparent data over SDSL Point-to-point data transmission service Configure and Loop Test via RS-232 Craft port Local and remote loopback features Integral BERT generator Applications Application : Point-to-Point Connection for Network Extension Application : Point-to-Point Connection with V.35 Data Com Unit (Must be at least version 1.4 firmware.) 4 Version 1.1

Specifications Item Channel Port Interface ITU-T G.703 E1 WAN Port -- SDSL Line I/F Indicators LED Connector BNC(x2) unbalanced, RJ-45 Balanced Impedance 75 or 120 Ohms, selectable Tx Level 75 Ohm: Pulse 2.37V nominal 120 Ohm: Pulse 3.00V nominal Relative Rx Level 0 to 43dB Bit Rate 2.048Mbps Line Code HDB3 Framing Unframed, CAS, CCS, CRC4 On/Off Timing Source Recovery at CO, DSL Loop Recovery Jitter Tolerance Meets ITU-T G.823 Complies with ITU-T G.703, G.704, G.706, G.732 Transmission Rate : 144 Kbps 2320 Kbps Data Rate : 144 Kbps 2320 Kbps Line Code 2B1Q Line Impedance 135 Ω Test Standard ANSI T1E1.413/94-006; ETSI ETR 152 Connection Loops One Pair (2-wire) Connector RJ-11 Power Green LED, indicate power and operation (WAN) LOS Red LED, DSL Loss of Signal LFA Red LED, DSL Loss of Frame Alignment ALARM Red LED, DSL Test & Error status LOOP Red LED, DSL in Loopback mode (E1) SigLoss Red LED, E1 Signal Loss SyncLoss Red LED, E1 Sync Loss ALARM Red LED, E1 Alarm LOOP Red LED, E1 in Loopback mode OAM&P Local ASCII Terminal via EIA RS-232 Port Environment Dimensions (WxDxH) Electrical Temperature Humidity CO/RT Power Input Power Consumption 0 C ~ 50 C 5% ~ 95% 213(w)mm X 152(d)mm X 25(h)mm 12VDC via AC Adapter Less than 8 Watts 5 Version 1.1

Packing This package shall contain the following items: 1. unit 2. AC Adapter (120VAC for North America, and 220-240VAC for Europe) 3. RS-232 Serial Cable, DB-9 to DB-9(optional) 4. This User's Guide 6 Version 1.1

Appearance Front Panel After connecting all cables and powering on the MSDTU01- A/E1, LED s on the front panel shall indicate the following status. LOOP Test/Loopback ALARM E1 Alarm SyncLoss E1 Sync Loss SigLoss E1 Signal Loss LOOP DSL Test/Loopback ALARM DSL Alarm/Error LFA DSL Loss of Frame Alignment LOS DSL Loss of Signal POWER Unit Power Applied The LED indicators provide an excellent indication of the communication status and possible link trouble locations when troubleshooting "link-down" problems. 7 Version 1.1

Rear Panel RJ11, SDSL for connection to local loop RJ-45, Balanced G.703 E1 Port, BNC, Unbalanced G.703 E1 Port 10P DIP switch, for setting speed, CO/CPE, Timing, E1 Framing, Nx64, etc. DB9, console port for connection to ASCII data terminal Power Jack, for connecting to a AC-DC power adapter, 12VDC, 1A 8 Version 1.1

Important Safety Instructions The following safety instructions apply to the : 1. Be sure to read and follow all warning notices and instructions. 2. The maximum recommended ambient temperature for is 40? (104? ) Care must be taken to allow sufficient air circulation or space between units when the is installed inside a closed rack assembly. The operating ambient temperature of the rack environment might be greater than room temperature. 3. Installation in a rack without sufficient air flow can be unsafe. 4. Racks should safely support the combined weight of all equipment. 5. The connections and equipment that supply power to the MSDTU01- A/E1 should be capable of operating safely with the maximum power requirements of the. In the event of a power overload, the supply circuits and supply wiring should not become hazardous. The input rating of the is printed on the nameplate. 6. The AC adapter must plug in to the right supply voltage, i.e. 120VAC adapter for North America and 230VAC adapter for Europe. Be sure the supplied AC voltage is correct and stable. If the input AC voltage is more than 10% lower than the standard may cause malfunction of the unit. 7. Installation in restricted access areas must comply with Articles 110-16, 110-17, and 110-18 of the national Electrical Code, ANSI/NFPA 70. 8. Do not allow anything to rest on the power cord of the AC adapter, and do not locate the product where anyone will walk on the power cord. 9. Do not service the product by yourself. Opening or removing covers can expose you to dangerous high voltage points or other risks. Refer all servicing to qualified service personnel. 10. Generally, when installed in the final configuration, the product must comply with the applicable safety standards and regulatory requirements of the country in which it is installed. If necessary, consult the appropriate regulatory agencies and inspection authorities to ensure compliance. 9 Version 1.1

11. A rare condition can create a voltage potential between the earth grounds of two or more buildings. If products installed in separate building are interconnected, the voltage potential can cause a hazardous condition. Consult a qualified electrical consultant to determine whether or not this phenomenon exists and, if necessary, implement corrective action before interconnecting the products. If the equipment is to be used with telecommunications circuit, take the following precautions: Never install telephone wiring during a lightning storm. Never install telephone jacks in wet location unless the jack is specially designed for wet location. Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface. Use caution when installing or modifying telephone lines (other than a cordless telephone) during an electrical storm. There is a remote risk of electric shock from lightning. Do not use a telephone or other equipment connected to telephone lines to report a gas leak in the vicinity of the leak. 10 Version 1.1

Installation 1. Connect the local loop (twisted copper pair telephone wire) to the WAN port at the RJ-11 jack. Be sure that this local loop has been properly connected to another remote unit. 2. Connect the E1 transmission line to the modem at the BNC connectors marked "TX" and "RX". Alternately, connect the twisted pair E1 cable to the RJ-45 connector. Please refer to the section on "Cables" for detailed pin assignment. 3. Power connection -- Warning : Do not apply the AC power before all the connections above have been connected. Connect the DC jack to the DC-IN of the unit Plug in the AC Adapter to the wall AC socket 4. Terminal Connection -- A data terminal or PC with emulation software can be connected to the TERMINAL port (RS-232) of the unit for configuration & monitoring purpose. Use an RS-232 serial cable to connect to a ASCII data terminal. The TERMINAL should be VT-100 compatible. 11 Version 1.1

Hardware Setup DSL rate and terminal type can be set up by adjusting the 10-pole DIP switch on the rear panel. Sw. 1 is for SDSL termination type, Sw.2 thru Sw. 6 are for adjusting the E1 and DSL rate, Sw. 7 will disable TS0, Sw. 8 and Sw. 9 set E1 frame mode, and Sw. 10 sets the E1 line termination. 1 ON 1. Rate Setting Table E1 Rate TS used DSL TS0 Dis. No.2 No.3 No.4 No.5 No.6 (TS0+data) for data Rate DSL Rate 128K ON OFF OFF OFF OFF 1 144K 114K 192K OFF ON OFF OFF OFF 2 208K 144K 256K ON ON OFF OFF OFF 3 272K 208K 320K OFF OFF ON OFF OFF 4 336K 272K 384K ON OFF ON OFF OFF 5 400K 336K 448K OFF ON ON OFF OFF 6 464K 400K 512K ON ON ON OFF OFF 7 528K 464K 576K OFF OFF OFF ON OFF 8 592K 528K 640K ON OFF OFF ON OFF 9 656K 592K 704K OFF ON OFF ON OFF 10 720K 656K 768K ON ON OFF ON OFF 11 784K 720K 832K OFF OFF ON ON OFF 12 848K 784K 896K ON OFF ON ON OFF 13 912K 848K 960K OFF ON ON ON OFF 14 976K 912K 1024K ON ON ON ON OFF 15 1040K 976K 1088K OFF OFF OFF OFF ON 16 1104K 1040K 1152K ON OFF OFF OFF ON 17 1168K 1104K 1216K OFF ON OFF OFF ON 18 1232K 1168K 1280K ON ON OFF OFF ON 19 1296K 1232K 1344K OFF OFF ON OFF ON 20 1360K 1296K 1408K ON OFF ON OFF ON 21 1424K 1360K 1472K OFF ON ON OFF ON 22 1488K 1424K 1536K ON ON ON OFF ON 23 1552K 1488K 1600K OFF OFF OFF ON ON 24 1616K 1552K 1664K ON OFF OFF ON ON 25 1680K 1616K 1728K OFF ON OFF ON ON 26 1744K 1680K 1792K ON ON OFF ON ON 27 1808K 1744K 1856K OFF OFF ON ON ON 28 1872K 1808K 1920K ON OFF ON ON ON 29 1936K 1872K 1984K OFF ON ON ON ON 30 2000K 1936K 2048K ON ON ON ON ON 31 2064K 2000K Unframed OFF OFF OFF OFF OFF 32 2064K 2064K 12 Version 1.1

The E1 data rate is equal to the number of timeslots used for data times 64 Kbps, plus 64 Kbps for timeslot zero (framing timeslot). The DSL data rate is equal to the E1 data rate plus 16 Kbps overhead. The TS0 Dis. (Timeslot zero disabled) DSL rate is equal to the number of timeslots used for data plus 16 Kbps overhead. Use this rate setting to match a remote datacom unit's HDSL rate ( CCS framing ONLY). 2. CO/RT configuration Terminal type DIP SW No. 1 CO ON RT OFF 3. Framing, CRC4 and termination configuration Sw. 7* Sw. 8 Sw. 9 Sw. 10 TS0 Frame Mode CRC4 E1 Term. ON Disable CAS** CRC4 On 75 Ohms OFF Enable CCS*** no CRC4 120 Ohms * Normal operation with two MSDTU01A/E1 units enable timeslot zero (TS0). (Please refer to the first application on page 4). If the MSDTU01A/E1 unit is connected over DSL to an MSDTU01A (refer to the second application on page 4) datacom unit (V.35, X.21, RS-530 or RS-449), then follow these rules. 1. Unframed E1: Enable TS0 and set E1 rate to "Unframed", set remote datacom unit's HDSL rate to 2064Kbps (data rate + 16Kbps). 2. CCS framing: Disable TS0 and match the "TS0 Dis" rate to the remote datacom unit's "HDSL rate" (data rate + 16Kbps). When timeslot zero is disabled, the unit allows E1 data to transmit transparently to the datacom side. The E1 side will not send TS0 to the far Datacom. Likewise, the E1 unit will regenerate TS0 from the Datacom side to send to the connected E1 equipment. 3. CAS framing: Not support when connected to remote datacom unit. **CAS mode may also be referred to as PCM30. In this mode, both timeslots 0 and 16 are used for frame alignment and signaling. Other timeslots are available to carry data. ***CCS mode may also be referred to as PCM31. In this mode, timeslot 0 is used for frame alignment and all other timeslots are available to carry data. 13 Version 1.1

Point-to-point Operation 1. The should be located on each side of the connection. One side must be set to "CO" and the other side must be set to "RT". Refer to the section on "Hardware Setup" for the CO & RT setup. Place the CO side unit towards the E1 timing source. 2. Insure that both CO & RT s are set to the same DSL rate. For example, 784Kbps. 3. Make sure that both CO & RT s have been connected to the E1 line properly. 4. For normal operation, 75 Ohm termination should be selected (DIP sw no. 10) when connecting the E1 over unbalanced coaxial cable at the BNC connectors, while 120 Ohm termination should be selected when connecting the E1 over balanced twisted pair cabling at the RJ-45 connector. DO NOT connect E1 signals to both the BNC and RJ-45 connectors at the same time. 5. When placing the MSDTU01-A into an E1 network, the source of timing is very important. Place the MSDTU01-A unit, which is closest to the E1 timing source, in CO mode and set E1 timing to "recovery". The E1 timing will be passed to the RT unit. The E1 device connected to the RT unit will be able to recover E1 timing from the RT unit. 6. Check the WAN LED on the -- it will remain lit when the Link is successfully established. The DSL training process may take around one minute and the WAN LED will flash during the training process. 7. After the DSL link is established, check the E1 setup. Both CO & RT side E1 must be set to use the same Frame Type. Both side E1 must also set the same E1/DSL rate parameter. Otherwise, they may fail to communicate with each other even though the DSL link is ready. 8. Follow the DSU/CSU manual to set the Frame type, clock source and other parameters. When the E1 parameters are properly set, you are ready to use the high-speed connection between the two networks. You may test the data transportation speed by using the internal BERT generator and loopback commands. 14 Version 1.1

Console Operation Starting Hyper-Terminal (on Windows 95 or Windows NT) To Start the Hyper-terminal, following the steps below: 1. Start "Hyper-terminal" program -- On Windows 95 or Windows NT : start Tool Bar Program Accessory Hyper Terminal Group Double Click Hypertrm.exe Enter Connection Name Select Icon Click OK 2. Select COM port to communicate with the -- Choose direct to COM1 or COM2 click OK 3. Set up Port Properties -- Port Setting : Bit per second : 9600 Data bits : 8 Stop bits : 1 Parity bit: None Flow Control : None Settings : Function, arrow, and ctrl keys act as : Windows keys Emulation : Auto-detect Back-scroll buffer lines : 500 ASCII Setup: Echo typed characters locally Line delay : 0 milliseconds Character line feeds t incoming line ends : enable 15 Version 1.1

Console Operation / Configuration 1.1 Turn on the power of and press any key, the initial terminal screen will be displayed. From any other menu, pressing ESC and Enter will return to the top menu screen. Pressing "zero" will exit any menu to the next higher level. : [MSDTU-01A] 1. xdsl status 2. BERT 3. Loopback Test 4. Information Select Number : 2.1 Information display Press "4" to display information << Information >> Firmware Version : 1.14 Hardware Version : 1.1 FPGA Version : 1 CTC UNION TECHNOLOGIES CO., LTD. http://www.ctcu.com/ The firmware version, hardware version and FPGA version will be displayed. This information should be readily available to give to technical support in the event there are difficulties in configuring or applying the units. 3.1 xdsl status display -- << Status >> Terminal Type : HTU-C Symbol Rate : 336Kbps In Sig Level : 015dB Far-End Signal Atten. : 002dB Noise Margin :-15.5dB Tx Gain : -0.48dB Descriptions of xdsl status items -- 3.1. Terminal Type : Indicates whether the Terminal Type of this unit is set for Central Office (HTU-C) or Remote Terminal (HTU-R). In pointto-point operation, one unit must be set to CO while the other must be set to RT. 16 Version 1.1

3.2. Symbol Rate : Indicates the DSL rate in kilobits per second. This is normally the data rate plus 16Kbps overhead. 3.3. In Sig Level : Indicates the input signal level of the DSL signal. 3.4. Far-End Signal Atten. : An approximate calculation of overall cable signal attenuation in db. 3.5. Noise Margin : Shows Noise Margin value. The noise margin is defined as the maximum tolerable increase in external noise that still allows for a BER (bit error rate) of less than 10-7. 3.6. Tx Gain : Shows current transmission gain level in decibels. Nominal transmit power is 13.5dBm, while Tx gain may vary from 1.6dB to +1.4dB. 4.1 Select "3" Loopback Test << Loopback >> *1. OFF 4. Isolated 2. PCM-PCM 5. HDSL-PCM 3. Analog 6. Remote Line Select Number : _ 4.1. Item "1" OFF, will turn off any loopback mode. 4.2. Item "2" PCM-PCM, turns on PCM-PCM loopback mode. In this mode, the E1 signal coming in the Rx terminal is looped to the E1 Tx terminal. 4.3. Item "3" Analog, turns on analog loopback mode. In this mode the local DSL Tx is looped back to local Rx. The DSL cable MUST be disconnected. 4.4. Item "4" Isolated, turns on isolated analog loopback. This loopback is the same as item "3", except the DSL cable need not be disconnected. 4.5. Item "5" HDSL-PCM, turns on digital loopback. In this mode the remote received DSL signal is looped back to the remote unit. 17 Version 1.1

4.6. Item "6" Remote Line, turns on remote digital loopback. This mode is used to test the DSL link.the local unit sends a command to the remote unit which then initiates its own HDSL-PCM loopback. This mode requires that an active DSL link already be established. PCM-PCM Analog E1 DSL E1 X DSL Isolated HDSL-PCM E1 DSL E1 DSL Remote Line E1 DSL E1 Figure examples of Loop back modes 18 Version 1.1

5.1 Select "2" BERT << BERT >> 1. Function 2. Pattern 3. Scale 4. BERT Status Select Number : 5.1. BERT Function : Selects the mode of Loop Back testing. << BERT Function >> *1. OFF 2. Normal 3. PCM Framed 4. PCM Serial Select Number : Normal mode selects the selected HDSL payload on a per-timeslot-basis. PCM Framed BERT tests only the selected PCM timeslots, while PCM Serial tests the entire PCM channel. 5.2. BERT Pattern : There are four patterns available for BER Testing; 2e4-1, 2e15-1, QRSS, and 2e23-1 << BERT Pattern >> *1. 2e4-1 2. 2e15-1 3. QRSS 4. 2e23-1 Select Number : 5.3. BERT Scale : Test duration in bits transmitted. << BERT Scale >> *1. 2^21 2. 2^25 3. 2^28 4. 2^31 Select Number : 19 Version 1.1

5.4. BERT Status : << BERT Status >> Pattern SYNC : SYNC Measurement : Complete Bit Errors : 000 Press '1' to review. This display is used to review the results of testing. If there is no pattern sync the display will read "No SYNC". During the testing process the display will read "In Progress". The accummulated or final number of errors will be displayed. The register for counting errors is only 8 bits (256) and will increment back to zero when full. Cables / Connectors 1. RS-232 Cable for connection to VT-100 type ASCII terminal TERMINAL (CRAFT) Port DB-9 DCE connector pin assignment, signal direction, and alarm relay contacts: Pin 2 ------ RXD DTE MSDTU01-A Pin 3 ------ TXD Pin 5 ------ SGND Pin 6 ------ Alarm relay common Pin 4 ------ Alarm relay NC (open on alarm) Pin 9 ------ Alarm relay NO (closed on alarm) Parameter : Data Speed : 9600 bps Parity : None Stop Bit : 1 bit Character Length : 8 Bits 1 2 3 5 4 Modem cable 1 2 3 5 4 1 2 3 5 4 Terminal cable 1 2 3 5 4 6 7 6 7 6 7 6 7 8 8 8 8 male male male female 20 Version 1.1

E1 BNC Connectors BNC Pin Designation Direction Function TX Center TTIP From MSDTU01-A Transmit data Sleeve TRING «Signal return RX Center RTIP To MSDTU01-A Receive data Sleeve RRING «Signal return E1 RJ-45 Connector RJ-45 Pin Designation Direction Function GND 8 GND «Frame Ground 7 GND «Frame Ground TX 4 TTIP From MSDTU01-A Transmit data + 5 TRING From MSDTU01-A Transmit data - RX 1 RTIP To MSDTU01-A Receive data + 2 RRING To MSDTU01-A Receive data - WAN DSL Connector Conn. Pin Designation Direction Function 3 TIP «Transmit data TX/RX 4 RING «Signal return DC - IN Connector TIP ---- DC12V+ RING Return (-) _ + 21 Version 1.1

22 Version 1.1

CTC Union Technologies Co., Ltd. Far Eastern Edison Science and Technologies Center (Nei-Hu HI-TEC Park) 6F-3, Lane 360, Nei-Hu Road, Section 1 Nei-Hu, Taipei, Taiwan Phone:(886) 2.2659.1021 (Rep) Fax:(886) 2.2799.1355 E-mail: info@ctcu.com http://www.ctcu.com