Programmable controller MCX06D

Similar documents
Programmable controller MCX152V

Programmable controller MCX06C

Programmable controller Type MCX06C

MCX08M2 Programmable controller

MCX06C Programmable controller

Data sheet. MCX15B electronic controller MAKING MODERN LIVING POSSIBLE. REFRIGERATION & air CONDITIONING DIVISION. Danfoss Electronics spa

Non-communicating room controllers

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

FX Input/Output (I/O) Modules XM07 and XM14

EXOcompact. Third generation freely programmable controllers

PEAK TM. PEAK TM controllers. Mid-Market BAS Smart equipment controllers. HVAC/R controllers

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

Millenium II +: general characteristics

General information. Display. Supply voltage. Input current

Extension module for lighting control

Programmable Relay ZEN V2 Units

General information. Supply voltage. Input current. Encoder supply. Power loss. Memory

Energy Management Modular DC Energy analyzer Type VIM-E and VIM-X

General information. Display. Supply voltage. Input current. Encoder supply. Power losses

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA

DT1102 V (PS) Fully Configurable Galvanic Isolator. Operating Instructions

PTU300 Combined Pressure, Humidity and Temperature Transmitter

DRTS 3 PLUS Advanced Protection Relay Test Set and Measurement System

POL635.XX/XXX POL636.XX/XXX POL638.XX/XXX POL638.70/XXX

General information. Display. Supply voltage. Input current

Non-communicating room controllers

General information. Display. Supply voltage. Input current. Encoder supply. Output current

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

FX06 Field Controller

LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E

General information. Display. Supply voltage. Input current

XT-9100 Technical Bulletin

General information. Display. Supply voltage

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

SBB4I2O230 ENG. Fire damper I/O Module. Benefits. Description

Displays Transducers. Displays and transducers

General information. Display. Supply voltage. Input current

RM35LM33MW liquid level control relay RM35-L V AC/DC

Type EKE 1B. English. More info. Applications. 1. Superheat controller: standalone / network. 2. Valve driver. Dimensions in mm EKE 1B

Onboard Inputs and Outputs. Remote User Interface. Integral LCD User Interface

I-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS

General information. Display. Supply voltage. Input current. Encoder supply. Output current

SX90 Process Controller

Energy Management BUS Adapter Type VMU-B

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

General information. Display. Supply voltage. Input current. Encoder supply. Output current

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

Universal Modules. Synco 700. Extension modules for use with controls of the Synco 700 family. Use

General information. Display. Supply voltage

Energy Management Energy Transducer Type ET112

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes

General information. Display. Supply voltage

AIAS. Technical description

Universal Controller

BACnet Controller for General-purpose Building Applications

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

MID PRELIMINARY DATA SHEET. RI-D Series. Single Phase Multifunction Energy Meter (MID Certified) MID

FEC - FAC. Metasys controllers. Complex BAS Programmable controllers. Catalog Page. Field Equipment Controllers

EngyVolt RV12 and RV15

s Climatix AHU ext. module 14 I/O POL955.XX/XXX Climatix

ATV12H075M3 variable speed drive ATV kW - 1hp V - 3ph - with heat sink

ATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink

CDC2000X. Technical Data Sheet

Select a Micro800 Controller

LBVR1718. Description. Features channel paperless recorder

DMT340 Series Dewpoint and Temperature Transmitters for Very Dry Conditions

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

Interface converter for VAV compact controllers

ATV320U04N4C variable speed drive ATV kW V - 3 phase - compact

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA 250 V AC

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

FX-PCX Expansion Input/Output Modules Catalog Page Code No. LIT Issued April 17, 2015

DMT345 and DMT346 Dewpoint Transmitters

MOD-IO9 Modbus Input / Output Modules, Wall Mounted

General information. Display. Supply voltage. Input current

iologik 4000 Series (M) Modules

PCD3.C90. Date Modification Asked by: Version E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Energy Management BUS Adapter Type VMU-B 01

Process displays For current and voltage

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate

Energy Management Modular Energy meters Type EM2-96

iothinx 4500 Series (45MR) Modules

FEATURES DESCRIPTION FEATURES

Millenium 3 logic controllers

The SF-586b Insertion Flow Meter For Compressed Air, Gases And Exhaust Air (up to 400 C) In Pipe Diameters From 25mm to 5000mm

Syr-line TMR48D Digital Timer

RE11RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

AND COMMUNICATION MODULES

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

CALEC energy master The benchmark in energy measurement

Electropneumatic miniature control valves Mounting Connectors Minisolenoid valves Indicators LED seals LED Valve modules Poppet 3/2 single pilot 4/2 s

ATV320U07M2C variable speed drive ATV kW V - 1 phase - compact

Transcription:

MAKIG MODER IVIG POSSIBE Technical brochure Programmable controller Danfoss range of universal MCX programmable controllers offers the functionality and reliability you need to get the best out of your heating, ventilation, air-conditioning and refrigeration (HVAC/R) equipment. With the MCX range, Danfoss is widening the concept of programmability and applying it to as many environments as possible is fitted with ED display, graphic CD display, or without display. It is an electronic controller that holds all the typical functionalities of MCX controllers in the compact size of 4 DI modules: programmability, connection to the CAbus local network, Modbus RS485 opto-insulated serial interface Features y 4 analog and 8 digital inputs y 3 analog and 6 digital outputs y Power supply 20/60 Vdc - 24 Vac y Remote access to data through CAbus connection for additional display (CD available) and keyboard y RTC clock for managing weekly time programs and data logging information y Modbus RS485 opto-insulated serial interface y Available with ED display, graphic CD display and without display for showing the desired information y Dimensions 4 DI modules MYK connection Modbus RS485 485 www.danfoss.com/mcx

General features FEATURES DESCRIPTIO 20/60 Vdc and 24 Vac ±15% 50/60 Hz. Maximum power consumption: 6 W, 9 VA Power supply Insulation between power supply and the extra-low voltage: functional DI rail mounting complying with E 60715 Plastic housing Self extinguishing V0 according to IEC 60695-11-10 and glowing/hot wire test at 960 C according to IEC 60695-2-12 Ball test 125 C according to IEC 60730-1. eakage current: 250 V according to IEC 60112 Operating conditions Storage conditions Integration Index of protection Period of electric stress across insulating parts Resistance to heat and fire Immunity against voltage surges Software class and structure Approvals CE: -20T60 / U: 0T55, 90% RH non-condensing -30T80, 90% RH non-condensing In Class I and/or II appliances IP40 only on the front cover ong Category D Category I Class A CE compliance: This product is designed to comply with the following EU standards: ow voltage guideline: 73/23/EEC Electromagnetic compatibility EMC: 89/336/EEC and with the following norms: E61000-6-1, E61000-6-3 (immunity for residential, commercial and light-industrial environments) E61000-6-2, E61000-6-4 (immunity and emission standard for industrial environments) E60730 (Automatic electrical controls for household and similar use) U approval: U file E31024 2

Inputs/outputs I/O TYPE UM SPECIFICATIOS Analog inputs Digital input Analog outputs Digital output TC, 0/1 V, 0/5 V 2 AI1, AI2 Analog inputs selectable via software between: TC temperature probes, default: 10 kω at 25 C pressure transducers with 0/5 V output Universal 2 AI3, AI4 Universal analog inputs selectable via software between: O/OFF (current: 20 ma) 0/1 V, 0/5 V, 0/10 V 0/20 ma, 4/20 ma TC (10 kω at 25 C) Pt1000 12 V+ power supply 12 Vdc, 50 ma max for 4/20 ma transmitter (total on all outputs) 5 V+ power supply 5 Vdc, 80 ma max for 0/5 V transmitter (total on all outputs) Voltage free contact 0/10 V, PWM, PPM PWM, PPM 8 DI1, DI2, DI3, DI4, DI5, DI6, DI7, DI8 Current consumption: 5 ma 2 AO1, AO2 Analog outputs selectable via software between: pulsing output, synchronous with the line, at modulation of impulse position (PPM) or modulation of impulse width (PWM): pulsing output, at modulation of impulse width (PWM) with range from 100 Hz to 500 Hz: 0/10 Vdc non optoinsulated output, referred to the ground 10 ma maximum loads 1 AO3 Analog output selectable via software between: pulsing output, synchronous with the line, at modulation of impulse position (PPM) or modulation of impulse width (PWM): pulsing output, at modulation of impulse width (PWM) with range from 100 Hz to 500 Hz: Relay 6 Insulation between relays 1 to 5: functional Insulation between relay 6 and the other relays: reinforced Insulation between relays and the extra-low voltage parts: reinforced Total current load limit: 33 A C1-O1, C2-O2, C3-O3, C4-O4, C5-O5 ormally open contact relays characteristics of each relay: 30 Vdc / 250 Vac for resistive loads - 100.000 cycles 0.7 A 250 Vac for inductive load - 100.000 cycles with cos(phi) = 0.5 U: 250 Vac - 3 A resistive - 1.5 FA - 9.0 RA - 144 VA pilot duty 30.000 cycles C6-C6-O6 Changeover contacts relay 8 A characteristics of each relay: 8 A 250 Vac for resistive loads - 100.000 cycles 4 A 250 Vac for inductive loads - 100.000 cycles with cos(phi) = 0.6 U: 240 Vac - 6 A resistive - 4.9 FA - 29.4 RA - 470 VA pilot duty 30.000 cycles 3

Connection diagram: top and bottom board To the AI (80 ma max) To the AI (50 ma max) TC, Pt1000, O/OFF, 0/1 V, 0/5 V, 0/10 V, 0/20 ma 4/20 ma DI 1 DI 2 DI 3 DI 4 DI 5 - TOP DI 6 DI 7 DI 8 AI 1 AI 2 AO 1 AO 2 AO 3 GD 5V+ GD 12V+ AI 3 AI 4 DI 1 DI 2 DI 3 DI 4 DI 5 DI 6 DI 7 DI 8 UIVERSA UIVERSA AAOG IPUT 3-4 DIGITA IPUT 1-8 - BOTTOM O 1 C 1 O 2 optoinsulated RS485 AAOG I/O RS485 CA CA MMI D + C 2 D - O 3 C 3 O 4 C 4 O 5 C 5 DIGITA OUTPUT 1-5 R 120 CA H CA CA GD ID CA H CA CA GD POWER SUPPY SYC ** DIGITA OUTPUT 6 0-10 V PWM-PPM 0-10 V PWM-PPM PWM-PPM * CAbus CAbus 1 1 SYC SYC C 6 C 6 O 6 24 Vac 20 60 Vdc 8 A 8 A AO1 TC 0/5 V TC 0/5 V AO2 RS485 (Modbus) local network Power supply board 24 Vac Phase sync AO3 supervisory network *OTE: connection has to be made on the first and last local network units, make the connection as close as possible to the connector **OTE: when AO is used as synchronised output, the sync input must be in phase with the load on AO 4

Connection COECTORS TYPE DIMESIOS TOP BOARD Analog input 3-4 connector 7 way screw plug-in connector type Digital input 1-8 connector 10 way screw plug-in connector type Analog I/O connector 7 way screw plug-in connector type RS485 connector 3 way screw plug-in connector type CA connector 4 way screw plug-in connector type CA MMI connector 4 way Connection 2515 Series type (2515-2041) crimping contact type: Connection (2500-2001) section cable AWG22-28 (0.32-0.08 mm²) instrument for the crimp type 1190-1298 BOTTOM BOARD Digital output 1-5 connector 10 way screw plug-in connector type pitch 5 mm section cable 0.2-2.5 mm² Power supply connector 2 way screw plug-in connector type Sync connector 2 way screw plug-in connector type Digital output 6 connector 3 way screw plug-in connector type pitch 5 mm section cable 0.2-2.5 mm² Dimensions ED display CD display o display 110 70 63 63 60 5

User interface TYPE FEATURES DESCRIPTIO ED display Display ED display with two groups of digits and 18 icons CD display Digits Allarm/warning icons Other icons Meaning of the icons and digits Dimensions Display Backlight Contrast Format Active visible area Keyboard umber of keys 4 Keys function Green colour Red colour Yellow/amber colour Settled by the application software 45x17 mm ST blue transmissive White ED backlight adjustable via software Adjustable via software 98x64 dots 29.4x19.2 mm Set by the application software Ordering DESCRIPTIO, 24V, ED, S, 24V, ED, RS485, RTC, S CODE R. 080G0108 080G0109, 24V, CD, S, 24V, CD, RS485, RTC, S 080G0111 080G0112, 24V, S, 24V, RS485, RTC, S 080G0114 080G0115 (S): Single Pack ote: Single pack include standard kit connectors Industrial pack codes are avaliable on request (these do not include standard kit connectors) Accessories DESCRIPTIO /EXC06D COECTORS KIT ACCCX, WIRED COECTORS FOR TO MMIGRS, 2m CABE CODE R. 080G0179 080G0083 6