Digital Storage Oscilloscope

Similar documents
CAN/ LIN Bus Decoder App

Differential Probe. GDP-040D for GDS-200 & GDS-300 Series QUICK START GUIDE GW INSTEK PART NO. 82DP-040D0MA1 ISO-9001 CERTIFIED MANUFACTURER

Digital Storage Oscilloscope

Digital Storage Oscilloscope

Digital Multimeter. GDM-8200A Series QUICK USER GUIDE GW INSTEK PART NO. 82DM-8255AMA1 ISO-9001 CERTIFIED MANUFACTURER

SpectrumShot. Software for the GSP-9330 Spectrum Analyzer QUICK START GUIDE REVISION MAY 2016 ISO-9001 CERTIFIED MANUFACTURER

Digital Storage Oscilloscope

The Next Generation of Portable Oscilloscope

Digital Storage Oscilloscope

Compact Digital Storage Oscilloscope & Digital Multimeter GDS-200 & GDS-300 Series

E300 USB Firmware Upgrade

Firmware Update Function

N2753A Windows XP to Windows 7 Upgrade Instructions

AC Power Meter GPM-8212 USER MANUAL

INSTRUCTIONS TO UPDATE FIRMWARE FOR / / Dranetz New Durham Road, Edison, New Jersey Telephone or

Oscilloscope System Recovery

Multi-Range DC Power Supply

The Angel of the Test and Measurement Industry Sexy and Beyond

Series 2260B DC Power Supply Version 1.82 firmware release notes

GCT-9040 AC Ground Bond Tester New Product Announcement

Spectrum Analyzer GSP-730 QUICK START GUIDE GW INSTEK PART NO. 82SP-73000M01 ISO-9001 CERTIFIED MANUFACTURER

IMPORTANT NOTE for. Choose the zip file v and unzip it in USB. Do not rename the UPG folder. Follow

Model Number(s): DSO5xxxA/DSO/MSO6xxxA. **Declassification of the 5000A/6000A Series Oscilloscope**

Table of Contents. 1.Introduction... P.2. 2.Product Tour... P Operating Instructions... P Important Notes... P.10

Lionstracs Groove X-R

(Disklavier E3 / Disklavier Control Unit DKC-850) Update Manual. Table of Contents. Updating the Disklavier...2

Dynamic Fast. Two conditions using same mode Support CC or CR mode. Each condition must use same mode Support CC or CR mode

GW Instek PEL-3032E DC Load New Product Announcement

PS751 - Firmware(FW) Upgrade Instruction

Lab Install Windows 8

Integrating RDX QuikStor into Windows Backup with Full System Recovery for Windows Desktop OS

INSTRUCTIONS TO UPDATE FIRMWARE FOR

Quantum HD Unity Software Update Procedure

Taurus Series Multimedia Players XI'AN NOVASTAR TECH CO.,LTD. Common Problems & Remedies Document Version: V1.4.0 Document Number: NS

Updating X30/ Bridge Software

TBS2000 Oscilloscope Demo Guide 28 JULY 2016

Data rate - The data rate is the number of bytes per second that the drive can deliver to the CPU.

GDS-2000E Series DSO New Product Announcement

Updating Systems Components in UniOP Series 400 Products

This bulletin was created to inform you of a firmware update that provides upgrades to the P-4000.

STYLE 6046 AKRO VIEW DIAGNOSTIC SOFTWARE INSTALLATION AND OPERATIONS MANUAL

HOW TO: Upgrade Windows XP to Windows 7 with Windows Easy Transfer

Firmware Update Procedure for the 3 rd Generation Rack-Mount RDMS Telemetry Receiver

PPH-1503 Programmable High Precision DC Power Supply New Product Announcement

Programmable DC Electronic Load PEL-2000A Series

User's Guide. User Notice. Copyright

Installation Instruction for USB Interface

E2460GS Oscilloscope Upgrade Kit

Powerful Stretch with Multi-range Technology

Integrating RDX QuikStor into Windows Backup with Full System Recovery for Windows Server OS

Updating Firmware of Agilent 8453 UV-vis systems

Meade LS6 & LS8 LightSwitch Primer

AG-UX180/UX170 Firmware update procedure

User's Manual. System Recovery

firmware scope. MHz options. 1 / 6

AU-EVA1 Firmware update procedure

Getting Start. FreeWave -- GDS-2000 PC Software. Features:

README.TXT

Genesys Logic, Inc. GL862. USB 2.0 PC Camera Controller. Product Overview

BIODEX. DOWNLOAD INSTRUCTIONS FIRMWARE UPGRADE v1.3x. FOR ATOMLAB 500, ATOMLAB 500Plus DOSE CALIBRATORS & ATOMLAB WIPE TEST COUNTER

Description DK Number Version Main Application DK EBOOT Loader DK Operating System DK

Manually Windows Update Xp To 7 Without Cd

This document contains the firmware release notes for two models. The SDS1202X-E is a dual channel 200 MHz scope.

Step 1. Overview. Goal. System Requirements - 1 x WaveAce passive probe. Setup

GOM-804/805 D.C. Milli-Ohm Meter New Product Announcement

B3223P23 Release Notes. Zhejiang Uniview Technologies Co., Ltd.

Here are brief instructions on how to save files to external USB memory devices.

A+ Guide to Managing and Maintaining your PC, 6e. Chapter 8 Hard Drives

The following file is used for updating the boot loader: xboot.bin: XSTREAM development platform boot loader image

A+ Guide to Hardware, 4e. Chapter 7 Hard Drives

DiskOnChip GANG Programmer Rev. B2-1.23

Quick Start Guide GV-VMS

Install Notes cbot v Recipe Installer For cbot

*P *

JARLTECH. ISO 9002 Certified. Lead with technology JP-8005U USB. Win customers with service. Cash Drawer Opener

This is the official software release containing the list of software components listed in the section 3 of the release note.

Setup Instructions for Upgrading the Windows XP Panasonic CF-19 Toughbook to Windows 7

xcm.lcd Software Installation & Update Instructions

1. Version Information

HP Video Over Ethernet. User Guide

This manual is to explain the procedure for updating the AU-XPD1 firmware on Windows.

CTC firmware upgrade manual Software installation and description for upgrading firmware on the CTC series circuit board. James Campion

CDL-160ETH. Ethernet and USB to HDMI Converter. Operation Manual CDL-160ETH

A. C.V/C.C PRIORITY MODE

DSO NANO v3 MANUAL.

Cisco Aironet Driver and Firmware FAQ

AG-HPX170 series Software (Firmware) update procedure

USER MANUAL TROUBLESHOOTING V

CDL-160ETH. Ethernet and USB to HDMI Converter. Operation Manual CDL-160ETH

Setup Network File Sharing between Windows PC and A-ScanPlus

Alaris S2000w Series Scanner Software Release Notes

K9 Series Firmware Update Guide

DSS Pro FAQ. Ver:

Mango3 Motrex User Manual

Installing macos High Sierra

How to boot Mac OS X 10.5 from RocketRAID esata for Mac

Manual Boot Camp Install Windows 8 From Iso

How To Install Windows Update Vista Without Cd Dell Inspiron 1720

Integrating RDX QuikStor TM into NetJapan ActiveImage TM Protector

Larson Systems Inc. FLASH 11 & FLASH 24 User Manual - Software / Firmware Updating

Transcription:

Digital Storage Oscilloscope GDS-1000B / GDS-2000E/ GDS-2000A/ GDS-3000 Series FIRMWARE AND KERNEL UPGRADE GUIDE GW INSTEK PART NO. N/A ISO-9001 CERTIFIED MANUFACTURER

This guide contains proprietary information, which is protected by copyright. All rights are reserved. No part of this guide may be photocopied, reproduced or translated to another language without prior written consent of Good Will company. The information in this guide was correct at the time of printing. However, Good Will continues to improve products and reserves the right to change specification, equipment, and maintenance procedures at any time without notice. Good Will Instrument Co., Ltd. No. 7-1, Jhongsing Rd., Tucheng District, New Taipei City 236, Taiwan.

UPGRADE PROCEDURE UPGRADE PROCEDURE This firmware upgrade guide describes how to upgrade both the DSO firmware and the operating system kernel. Upgrade firmware 1. Insert a USB flash disk containing the firmware file, xxx.upg into the front panel USB slot. 2. Remove all probes and cables from the BNC terminals. 3. Press the Utility key and select File Utilities from the bottom menu. Utility 4. Rotate the Variable knob to select the USB directory and then press the Select key. Up VARIABLE Down Select 3

GDS-1000B/2000E/2000A/3000 Series Upgrade Guide 5. Rotate the Variable knob to select the xxx.upg file and then press the Select key. Press the Select key again to begin the upgrade procedure. Up VARIABLE Down Select 6. When the procedure has completed restart the scope. Note For the GDS-3000 models: Steps 7 & 8 only apply to 5GSa/s models (GDS- 3154, GDS-3254, GDS-3352/4). 2.5GSa/s models (GDS-3152 & GDS-3252) will bypass these two steps. Upgrade Kernel 7. When the screen goes blank during the booting process, press the lit CH1 key three times. (For GDS-3154, GDS-3254, GDS- 3352/4, 5GSa/s models only) CH1 à X3 CH1 4

UPGRADE PROCEDURE 8. The scope will return to the main screen after the CH1 key has been pressed. (For GDS-3154, GDS-3254, GDS-3352/4, 5GSa/s models only) 9. Repeat steps 3~6 to upgrade the kernel. The same file is used again to upgrade the kernel. 10. When the calibration message appears for the second time after the oscilloscope has restarted, press TEST in order to perform the phase calibration officially. (For GDS-3154, GDS-3254, GDS-3352/4, 5GSa/s models only) Please note that the entire phase calibration may take about 10 minutes. 11. The upgrade procedure is complete after the second upgrade. 5

GDS-1000B/2000E/2000A/3000 Series Upgrade Guide Note The following note is for the GDS-3000 only. If the existing firmware version is earlier than v1.07, please repeat this firmware upgrade procedure twice. For firmware versions earlier than v1.07 (v1.00~v1.06), please upgrade both the DSO firmware and the OS kernel (follow the operation steps 1 to 10). This means that you need to do the same upgrade procedure twice. If upgrading the firmware from V1.07 to v1.08 or later, only update the firmware. The kernel upgrade is not required (follow operation steps 1 to 6). If the upgrade procedure crashes and freezes during the upgrade, please use the safe mode upgrade method instead. Please see the next chapter on details on how to use the safe mode upgrade method. 6

SAFE MODE UPGRADE PROCEDURE SAFE MODE UPGRADE PROCEDURE Note If the upgrade procedure crashes and freezes during the upgrade, you use the safe mode upgrade method instead. M Hz The upgrade file name for this method are either xxx.opg(for GDS-3000 150-350 M Hz ) or xxx.upg (for GDS-1000B, 2000A, 2000E, GDS-3000 500 M Hz) Upgrade firmware by safe mode 1. Remove all the files on the USB flash disk. 2. Copy the firmware file xxx.opg or xxx.upg into the USB flash disk (root directory only). Insert the USB flash disk into the front panel USB slot. 7

GDS-1000B/2000E/2000A/3000 Series Upgrade Guide 3. Power up the oscilloscope and at the same time, keep rotating the VARIABLE knob a number of times until the oscilloscope boots into the firmware upgrade safe mode, as shown in the snapshot below. 4. When the xxx.opg or xxx.upg file on USB flash disk has been recognized by oscilloscope, the message usb device ready will appear on the lower left corner. 5. Press the F1 key. The oscilloscope will automatically start upgrading the firmware. When the status indicator at the center of the display has completed, the upgrade grade procedure (using the safe mode) is complete. ongoing complete 8

SAFE MODE UPGRADE PROCEDURE 6. The oscilloscope will restart automatically. After the scope has restarted, check the firmware version by pressing Utility à System à System Info. The system information screen should now show the new firmware version that was updated. For more information, contact your local dealer or GWInstek at www.gwinstek.com / marketing@goodwill.com.tw. 9