SPECIFICATION M/N: MPD-F For SWITCHING POWER SUPPLY

Similar documents
SPECIFICATION M/N: MPD-F For SWITCHING POWER SUPPLY. Revision History

SPECIFICATION. For SWITCHING POWER SUPPLY M/N: MPD-F113-V

TEK360M series is a fan-less 300W, U-frame, switching power supply with active PFC function for medical application. Rated Output Power.

Series MPM-815H 150W PFC MEDICAL ATX POWER SUPPLY

MPM-U653-DCF-B M/N: MPM-U653-DCF-B. 650W Medical AC / DC SPECIFICATION FOR SWITCHING POWER SUPPLY. Revision History

PRODUCT SPECIFICATION File: EA-A0601HE-12 Model: SSA-0601HE-12 Date: Apr. 17, 2015

MPO-120S Series. Single Output, 180W Compact, Open Frame AC/DC Power Supplies. Key Features:

Series MPM-X12Y 120W PFC MEDICAL POWER ADAPTER

LFWLP225 SERIES 225 Watt Open Frame Power Supply Measures: 4.00 x 2.00 x 1.00

< 50 A max. (115 VAC) / < 70 A max. (230 VAC)

MPU-120S Series. Single Output, 180W Compact, U-Channel AC/DC Power Supplies. Key Features:

LFWLP350 SERIES 350 Watt Open Frame Power Supply Measures: 5.00 x 3.00 x 1.00

300 WATT, PFC, OPEN FRAME POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, RMW 300W SERIES

Ripple & Noise (max) (See Note 2) 5V output: 100mVp-p; 12V - 27V outputs: 150mVp-p; 48V output: 200mVp-p

ECF40 Series. 40 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

Snaptec Australia Pty. Ltd.

LFMWLP225 SERIES 225 Watt Open Frame Power Supply Measures: 4.00 x 2.00 x 1.00

PRODUCT SPECIFICATION File:SSA Model : SSA Rev:A2 Date: Nov. 29, 2010

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 90% at 90V AC)

500Watts Medical Single Output

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 77% at 80V AC)

efo Series Wide range AC/DC Single Output 1000W Rugged Power Supply Electrical Specification for: Telkoor Part Number:

4 x 2 x 0.75 Inches Form factor. 180 Watts with Forced Air Cooling. Approved to EN/IEC Efficiencies up to 92% Standby Power < 0.

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 95% at 85V AC)

CINT W Triple Output Industrial Series

-48 VDC Input. ETSI Compliant. NEBS Compliant. Convection-cooled. Covered Versions Available

CPCI - 6U - DC - 350W

Watts. xppower.com. General. Input. Environmental. EMC & Safety. Output. IT & Medical Approvals. Energy Efficiency Level V, CEC2008 & EISA 2007

Constant Voltage Mode

275 Watt Medical Ultra low profile

Model No. ( Single Output ) ATC-3.3S ATC-5S ATC-12S ATC-15S ATC-24S Max Output Wattage (W) 10W 10W 10W 10W 10W VAC or VDC

VP ELECTRONIQUE MASSY - Tel

MB2000ERUI. High Isolation, 1 x 2 20W, 4:1 Input Range DC/DC Con vert ers. Key Features:

Electrical Specifications. Input Current 115 VAC: 1 A max. 230 VAC: 0.5 A max.

60 Watt Medical (MWLT)

CPCI - 6U - AC - 600W

MPV1060RI4. Ultra Wide Input, Compact Industrial Grade, PV Power DC/DC Con vert ers. Key Features:

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 77% at 80V AC)

REVISION HISTORY Rev Level Rev Date Change Made Reason for Change Effective Approved By A 13/12/08 Specification Release 13/12/08 S. Sadot A1 13/02/09

Safety Standards. Model Number: Unit Weight:

HEC-100RTN-48QSCA Rev A1.0

These power supplies are ideal for telecom, datacom, industrial equipment and other applications.

MPV1560RI4. Ultra Wide Input, Compact Industrial Grade, PV Power DC/DC Con vert ers. Key Features:

Safety Standards. Model Number:

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

12-15VDC (12V±5%) 24-28VDC (24V±5%)

5 x 8.5 x 1.61 Inch Form Factor. Convection Cooling Rated. Approved to EN Dual Fusing. Current Sharing. Open Frame. Peak Power Capability

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Series AMEL20-AZ 20 Watt AC-DC / DC-DC Converter

Safety Standards. Model Number:

MI1000ERW. Series. Miniature 1 x 1, 2:1 Input, 10W DC/DC Con vert ers. Key Features:

Power Factor Model Number Voltage Voltage

Chrome Class II DIN Rail Power Supply 24V 10W 1 Phase (NEC Class 2 & Household) / DRC-24V10W1HZ

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

AC-DC POWER SUPPLY UNIVERSAL INPUT, DESK TOP, WATTS MEDICAL APPLICATIONS MUI310-A Series

Safety Standards. Model Number:

RoHS APPROVAL SHEET 15V/2.0A SERIES NO. (M04) EA1030CU CUSTOMER CUSTOMER P/N DESCRIPTION EDAC MODEL DATE REVISION 0 APPROVED DESIGN PREPARE

MVAD040 Series 40W 2" x 4" AC-DC Power Supply Converter

Safety Standards. Model Number:

Specification For 90 Watts Adapter Power Supply Model No: ADB002 Customer ID: 000G Revision: 4.0

Safety Standards. Model Number:

Application Package Dimension Output Input Output Output Protection Option Code Code Power Voltage Quantity Voltage Type (W) (VAC) (VDC)

Chrome DIN Rail Power Supply 12V 9.96W 1 Phase (Class II & NEC Class 2) / DRC-12V10W1A

LED Indicator. Class I

3.3V & 5V max 150W, total output max 300W

Safety Standards. Model Number:

GSP750 Series. 750 Watts. AC-DC Power Supplies. Models & Ratings. Input

Chrome DIN Rail Power Supply 24V 10W 1 Phase (Class II & NEC Class 2) / DRC-24V10W1A

12-15VDC (12V±5%) 24-28VDC (24V±5%)

Chrome DIN Rail Power Supply 24V 10W 1 Phase (Class II & NEC Class 2) / DRC-24V10W1AZ

100BPS15 B. MDS Medical AC-DC Open Frame 15Volt, 100Watt / MDS-100BPS15 B ``` Highlights & Features. Safety Standards.

Features. Regulated Converter. RAC35-G/OF 35 Watt 4 x 2 Open Frame RAC35- SG/OF. AC/DC Converter

Revision Issue Date Pages Affected A0 08/14/2006 ALL Modify From CP-8120 Specification Rev:ED by Customer given.

Safety Standards. Model Number:

Safety Standards. Model Number:

040APS12 B MDS. MDS Medical AC-DC Open Frame 12Volt, 40Watt / MDS-040APS12 B ``` Highlights & Features. Safety Standards.

Safety Standards. Model Number:

CPS Industrial Power Supply

PMT. Safety Standards. Model Number:

Max Output Power Voltage. Convection Forced Convection Forced Nom Peak (2) Model Number (1)

Note1: Typ. efficiency is 230VAC and full load 12VDC 24VDC 48VDC ms 8ms 16ms 80ms

Simple but elegant look and ease of installation make it ideal for various industrial applications.

Output Voltage* (nom.)(adjustable)

Chrome DIN Rail Power Supply 5V 7.5W 1 Phase (Class II & NEC Class 2) / DRC-5V10W1AZ

AC-DC POWER SUPPLIES UNIVERSAL INPUT, 65 WATT MEDICAL APPLICATIONS MUI65 SERIES

Environmental. Electrical Specifications at 25 O C E Output Constant Current

Max. Output Power. Typical Efficiency (3) 0 ~ 25.0 A 300 W 91.5% 0.96 EBV-350S012SV 0 ~ 14.6 A 350 W 93.5% 0.96 EBV-350S024SV

KS15. Output Current Model Output Current Model Output Current Model 5V 1.0A KS A KS A KS V 0.45A KS A KS

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

VER05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input. Output

Environmental. Electrical Specifications at 25 O C E Output Constant Current

Electrical Specification for: efo Wide range AC/DC Single 12V Output 400W Power Supply Telkoor Part Number: CUSTOMER SIZE CAGE CO

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

40 & 60 Watt Models. Low Leakage Current. EN61000 Compliant. Single & Multiple Outputs. Cover Kits Available

Safety Standards. Model Number

Sync DIN Rail Power Supply 24V 30W 1 Phase (NEC Class 2) / DRS-24V30W1AZ

GLX40 GLX50 UL EN GLX60 GLX110-B GLX110-C GLX200 GLX140-C GLX140-CF GLX150-C GLX17Q-C GLX17S-C GLX250-CEF GLX250-CF

SPECIFICATIONS. Input Output Agency Approvals 0 ~ 62.5A. toll-free (603)

Universal Power Supplies

Max. Output Power(2) Typical Efficiency (3) 0 ~ 18.4 A 220 W 91.5% 0.96 EBV-250S012SV 0 ~ 10.5 A 250 W 93.0% 0.96 EBV-250S024SV

Transcription:

SPECIFICTION For SWITCHING POWER SUPPLY M/N: MPD-F113-2 Revision History REV. Mar. 10 th 2011 Revised the value of inrush current. REV. Mar. 15 th 2011 Conformed the solution of EMI class B. REV. Mar. 17 th 2011 Revised the dimension. REV. Mar. 28 th 2011 Updated safety approvals status. REV. Nov. 25 th 2011 Revised the initial setting accuracy. REV. Jun. 4 th 2013 dded recommended torque of input connector. REV. Nov. 25 th a) dded vibration test 2015 b) dded "or equivalent" after "Dinkle"

FETURES 110W isolated DC/DC converter with 11.7 CFM forced air-cooling, 70W convection cooled Fully isolated Primary to Secondary; Primary to Earth Ground Wide input range 9-32VDC Compact size 2 x 5 inch Low inrush current to prevent power adapter turn on issue Input polarity reversed protection Built in DC input on/off switch controller High efficiency up to 89% 1. Description The MPD-F113-2 is a 110W single output DC/DC converter. It is a compact size 2 x 5 and wide input range from 9-32VDC. Fully isolated primary to secondary and primary to earth ground avoid disturbed noise to affect secondary side. The built in DC input on/off switch controller can use with a normal on/off switch, instead of high rated current switch, and TTL signal control is available as well (see 8. application note). In addition, design in polarity reverse protection to avoid wrong input polarity. Output Voltage Min. Output Rated Output Max. output Line (Note 1) Regulation Load Regulation Ripple & Noise Initial (Note 2) p-p Setting (Note 3) ccuracy +12V 0 5.8 9.2 ±1% ±1% 120mV 11.76V to 12.24V Total Output Power: 110W at 50 C environment temperature (Note 4). Note: 1) When output current above 5.8, it has to force air cooling 11.7 CFM. 2) Measured by a 20MHz bandwidth limited oscilloscope and the each output is connected with a 10µF Electrolytic capacitor and a 0.1µF Ceramic Capacitor. 3) t factory, all outputs in 60% rated load. The +12V output is set to between 11.88V and 12.12V. 4) The total DC continuous power shall be kept with 70W at input from 18V to 32VDC; 65W at input from 12V-17.9VDC; 60W at input from 9-11.9VDC convection cooled and 110W at input from 12 to 32VDC; 95W at input from 9 to 11.9VDC with force air cooling 11.7 CFM. 2. Input Specification Input Voltage Continuous input range. 9 12/24 32 VDC Input DC Input Voltage 10VDC, rated load. 13 Inrush Cold start at 25 C. 45 3. Output Specification Efficiency t input voltage 12/24, rated load condition. 88 89 % Minimum load See Chart of Description Ripple & Noise Rated load, 20MHz bandwidth See Chart of Description Output Power Continuous output power. See Chart of Description Line Regulation Less than ±1% at rated load with ±10% changing in input voltage +12V and +24V. See Chart of Description Load Regulation Measured from 60% to 100% rated load and from 60% to 20% rated load (60% ±40% rated load) for each output, and others See Chart of Description voltage setting at 60%. REV. Nov. 25 th 2015 Page 1 of 4

4. Interface Signals and Internal Protection Short Circuit or Over Load Protection Input On/Off switch The power supply will go into hiccup mode against short circuit or over load conditions, and will auto-recovery while fault conditions moved. (1) Use a switch to short pin1 and pin2 of SW1 to turn on the power supply. (2) Or, it can use TTL signal to control the power on/off (please see more detail at pplication Note). Over Voltage Protection For some reason the power supply fails to control itself, the build-in over voltage protection circuit will shut down the outputs to prevent damaging external circuits. The trigger point is from 12.8V to 15V. 5. Safety pprovals, EMI and EMS Specification IEC 60950-1: 2005+1: 2009, 2 nd CE (LVD) approved EN 60950-1: 2006+1: 2010 pprovals UL 60950-1, 2 nd Edition, 2007-03-27 CS C22.2 No.60950-1-07, 2 nd Design to meet Edition, 2007-03 Radiation (Note) EN 55022 / CISPR 22 & FCC Part 15 Class Conduction EN 55022 / CISPR 22 & FCC Part 15 EMS IEC 61000-4-2: 2001, 8KV air discharge, 6KV contact discharge IEC 61000-4-3: 2002, 3V/m IEC 61000-4-4: 2004, 0.5KV line & PE Criteria IEC 61000-4-5: 2001, 0.5KV line to PE IEC 61000-4-6: 2006, 3V/m Note: 1) s a build-in type power supply, the power supply needs to be installed in a suitable enclosure to pass the EMI/EMC tests. The final assembly has to comply with the valid EMI/EMC and safety. 2) With Class B radiation and conduction are required an additional filter circuit, please see the figure below. MGIC POWER also provide the electrolytic capacitor and the common mode choke, please feel free to contact us if has any request. INPUT - + C L CN1 1 MPD-F11 3-2 C = electroly tic capacitor = 50V / 47uF L = common mo de choke = 19 6.2uH (core: CME / T14 x 8.4 x 12-C / 10 material) Figure. 6. Environment Specification Operating Temperature Derate linearly above 50 C by 1.5% per C t 100% load: +50-10 to a maximum temperature of 70 C t 70% load: +70 C Storage Temperature -20 +75 C Relative Humidity Non-condensing. 10 90 %RH ltitude Operating 2K meter REV. Nov. 25 th 2015 Page 2 of 4

7. Mechanical Specification Dimension 50.8 (L) x 127 (W) x 32.3 (H) mm, Tolerance +/- 0.5mm. Connector CN1 --- DC input: Dinkle ED500V-02 Terminal blocks or equivalent. CN2 --- DC output: Molex 5273-04 or equivalent. FN --- Output: Molex 5045-02 or equivalent. SW1 --- Remote on/off Molex 5045-02 or equivalent. Pin ssignment CN1 Pin 1. + 2. - (With max. torque=0.4n*m) CN2 Pin 1. +12V 3. GND 2. +12V 4. GND FN Pin 1. +12V 2. GND SWITCH Pin 1. + 2. - Dimension 50.8 (L) x 127 (W) x 32.3 (H) mm, Tolerance +/- 0.5mm. SWITCH SWITH CN1 1 1 FN 1 CN2 8. pplication Note Please refer circuit below when use TTL to control the PSU turning on/off. Connect to SW1 + and - REV. Nov. 25 th 2015 Page 3 of 4

9. Vibration Test mbiance Condition Temperature:20~35 Humidity:50~75 %RH Test Standard IEC 60068-2-6 Test Condition Frequency Type:Sweep Frequency Frequency Range:10~55 Hz Sweep Rate:60 minute / cycle Number of cycle:1 cycle / axis Direction:X, Y and Z axis REV. Nov. 25 th 2015 Page 4 of 4