OnCell G3100 Series Quick Installation Guide

Similar documents
NPort 5100 Series Quick Installation Guide

NPort 5400 Series Quick Installation Guide

NPort 6150/6250 Series Quick Installation Guide

NPort W2150A/W2250A Series Quick Installation Guide

NPort 5200 Series Quick Installation Guide

NPort 6600 Series Quick Installation Guide

NPort S8000 Series Quick Installation Guide

MGate 5118 Quick Installation Guide

MGate 5111 Quick Installation Guide

MGate 5105-MB-EIP Quick Installation Guide

MGate MB3170/MB3270 Quick Installation Guide

OnCell G3150A-LTE Series

NPort Z2150 User s Manual

DT Desktop Series

UPort 1200/1400/1600 Quick Installation Guide

MGate TM EIP3000 DF1 to EtherNet/IP Gateway User s Manual

Moxa TCC-100 Series Hardware Installation Guide

TCF-142 Quick Installation Guide

MGate MB3000 Modbus Gateway User Manual

5600 Series. 8 and 16-port Serial Device Servers. Features. Internet Readiness for up to 16 Serial Devices

NPort Z2150/Z3150 Series

MGate MB3000 Modbus Gateway User s Manual

Modbus TCP/RTU Gateway

Serial/Ethernet Converter

CP-114EL/CP-114EL-I Quick Installation Guide

UPort 1200/1400/1600 Quick Installation Guide

NPort 5400 Series. 4-port RS-232/422/485 serial device servers. Network-Readiness for up to Four Serial Devices

UC-8410A Quick Installation Guide

TCF-142-RM Series Hardware Installation Guide

DA-820 Series Quick Installation Guide

Moxa TCC-100 Series User s Guide

NPort 5400 Series. 4-port RS-232/422/485 serial device servers. Network-Readiness for up to Four Serial Devices

IA240/241 Hardware User s Manual

V2400 Series Expansion Modules

Feature and Benefits. Certifications

SunSpec Reference Architecture SunSpec CEA 2045 Inverter Adaptor

Features and Benefits. Certifications

Arm-based wireless-enabled DIN-rail industrial computers with 2 serial ports and 2 LAN ports. Features and Benefits.

EX KVIS RS232/422/485 3-in-1 Serial to USB Adapter (w/ 4KV Isolation, 15KV ESD Surge Protection)

ICF-1150 Series Quick Installation Guide

UC-2100 Series Hardware User s Manual

V2403 Quick Installation Guide

USB Connectivity. USB Connectivity

Features and Benefits. Certifications

MGate MB3000 Modbus Gateway User s Manual

UC-7112-LX Plus/UC-7112/UC-7110 Hardware User s Manual

Features. Preliminary. Industrial IEEE b/g/n with 2x10/100Base-T(X) 1x RS-232/422/485 IoT LTE LPWAN Gateway. Introduction

MGate TM EIP3000 DF1 to EtherNet/IP Gateway User s Manual

iologik 2500 Series Quick Installation Guide

ICF-1150 Series Quick Installation Guide

Bluetooth to RS-232&RS422/485. EX-9132B/BI Bluetooth Adapter Operation Manual

IDS-141A/181A. Industrial 4-port/8-port slim type serial to Ethernet device server. Features. Introduction. DS-Tool

MGate 4101-MB-PBS Series

EDR-G902/G903 Quick Installation Guide

Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA. Features and Benefits. Certifications

UC-7101 Hardware User s Manual

Arm-based palm-sized industrial computers with 2 serial ports and 2 LAN ports. Features and Benefits. Certifications

NPort IA5000A Series. 1, 2, and 4-port serial device servers for industrial automation. Overview

iologik 2500 HSPA/GPRS/WLAN Series

Features and Benefits. SNMP MIB-II for network management. Certifications

MGate 5105-MB-EIP Series

V2400 Series Expansion Modules

EDR-810 Series Quick Installation Guide

USB to RS-232/RS422/485. US-101-I USB To Serial Operation Manual

UC-7400 Plus Hardware User s Manual

Lantech LSC-1102B SERIAL TO TCPIP CONVERTER. User Manual

Features and Benefits. Certifications

UPort TM 1100 Series Quick Installation Guide

Features and Benefits. User-friendly LCD panel for easy installation Adjustable termination and pull high/low resistors.

MPC-2150 Series Quick Installation Guide

USB to RS-232/RS422/485. URK-228-I USB To Serial Operation Manual

UPort 1100 Series User s Manual

NPort 5100A Series. 1-port RS-232/422/485 serial device servers. Overview. A Greener Serial-to-Ethernet Solution

3G/4G LTE Cellular to Ethernet and Serial Secure Industrial Gateway. SE5901B Series FEATURE HIGHLIGHTS PRODUCT DESCRIPTION

1 to 16-port RS-232, RS-422/485, and RS-232/422/485 USB-to-serial converters. Features and Benefits. Certifications

W406 Hardware User s Manual

Tel: Fax:

iologik 2500 HSPA/GPRS/WLAN Series

iopac 8500 Series Rugged modular RTU controllers Overview Programmable Controllers High Sampling Rate Analog Input Prerecord Feature

SERIAL TO WiFi CONVERTER EX-9486C-W User Manual

NE-4100-P Series User s Manual

Features and Benefits. Fast 3-step web-based configuration. Certifications

Features and Benefits. Certifications

UPort TM 200/400 Series Quick Installation Guide

NPort DT/DTL Series User s Manual

Features and Benefits. Certifications

3G/4G LTE Cellular to Ethernet and Serial Secure Industrial Gateway. SE5901B Series FEATURE HIGHLIGHTS PRODUCT DESCRIPTION

Features and Benefits. Certifications

UPort 2000 Series User s Manual

Operation Manual of EX9132CST-Series

General Operating, Maintenance and Installation Manual

TN-5308 Quick Installation Guide

3G/4G LTE Cellular to Ethernet and Serial Secure Modbus Gateway/Router. MB5901B Series FEATURE HIGHLIGHTS PRODUCT DESCRIPTION

MEC-COM-M134. User s Manual

ThinkCore IA241/240 Hardware User s Manual

Industrial Serial Device Server

IMC-21 Quick Installation Guide

W315/325/345 Hardware User s Manual

KAUGJUHTIMISSÜSTEEMID TELECONTROL SYSTEMS MODEM TELEM-GSM/GPRS 3G. User manual

Installation and Configuration Quick Guide. R3000 Lite. Industrial Dual SIM Cellular VPN Router (1 Eth + 1 RS RS USB Host)

Transcription:

OnCell G3100 Series Quick Installation Guide Edition 4.1, August 2016 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778 Moxa Europe: Tel: +49-89-3 70 03 99-0 Fax: +49-89-3 70 03 99-99 Moxa India: Tel: +91-80-4172-9088 Fax: +91-80-4132-1045 Moxa China (Shanghai office): Toll-free: 800-820-5036 Tel: +86-21-5258-9955 Fax: +86-21-5258-5505 Moxa Asia-Pacific: Tel: +886-2-8919-1230 Fax: +886-2-8919-1231 2016 Moxa Inc. All rights reserved. P/N: 1802031000016 *1802031000016*

Overview There are currently six models in the OnCell G3100 series of IP-gateways: the OnCell G3110, OnCell G3150, OnCell G3110-HSPA, and OnCell G3150-HSPA. The main difference between the models is the serial interface type and cellular connection speed. The OnCell G3100 industrial RS-232, RS-232/422/485 GSM/GPRS/EDGE, or UMTS or HSPA IP gateways are some of the most affordable, secure, and versatile products available in the cellular networking market today. These gateways also provide remote access and TCP/IP support, and can be configured over a network. Package Checklist Moxa s OnCell G3110 Series is shipped with the following items. If any of these items is missing or damaged, please contact your customer service representative for assistance. Standard Accessories Omni 1 dbi rubber SMA antenna (OnCell G3100 model name: ANT-CQB-ASM-01; OnCell G3100-HSPA model name: ANT-WCDMA-ASM-1.5) Din-rail kit 5-pin terminal block (screw type) 10-pin terminal block (screw type) Quick installation guide (printed) Warranty card Optional Accessories Power Adaptor: 1.2 A (or above) @ 12V DC power supply Power jack to terminal block cable Quad-band GSM/GPRS/EDGE antennas for OnCell G3110/G3150 series (impedance = 50 ohms): ANT-CQB-AHSM-00-3m: Omni 0dBi/10cm, magnetic SMA antenna, 3 m ANT-CQB-AHSM-03-3m: Omni 3dBi/25cm, magnetic SMA antenna, 3 m ANT-CQB-AHSM-05-3m: Omni 5dBi/37cm, magnetic SMA antenna, 3 m Note: Please notify your sales representative if any of the above items are missing or damaged. - 2 -

Hardware Introduction OnCell G3110/G3150 Front Views OnCell G3110-HSPA/ OnCell G3150-HSPA Rear View Top View Bottom Views OnCell G3110/G3110-HSPA OnCell G3150/G3150-HSPA Side Views - 3 -

Reset Button Press the Rest button continuously for 5 second to load factory defaults: Use a pointed object, such as a straightened paper clip or toothpick, to press the reset button. This will cause the Ready LED to blink on and off. The factory defaults will be loaded once the Ready LED stops blinking (after about 5 seconds). At this point, you should release the reset button (the default IP is 192.168.127.254). LED Indicators The LED indicators on the front panel of the OnCell G3100 are described in the following table. LED Name Power Data GSM GRPS UMTS HSPA Ready Fault Signal (3 LEDs) LED Color LED Function Green DC Power is active Off Power is off, or power error condition exists. Green Serial Tx Amber Serial Rx Off Ethernet cable is disconnected. Amber GSM is connected. Off GSM is disconnected. Amber GPRS is connected. Off GPRS is disconnected. Amber UMTS is connected. (OnCell G3100-HSPA only) Off UMTS is disconnected. (OnCell G3100-HSPA only) Amber HSPA is connected (OnCell G3100-HSPA only) Off HSPA is disconnected (OnCell G3100 HSPA only) Steady on: Software Ready. Green Blinking slowly (1 second): The OnCell has been located by the OnCell Search Utility. Off Power is off, or is booting up. Steady on: Booting up, or IP fault. Red Blinking slowly (1 second): Cannot get an IP address from the DHCP server Off Power is off, or there is no error condition. Number of lit LEDs indicates signal level Green (at least 2 LEDs must illuminated for data transmission) Digital Input and Output Six terminals on the terminal block are reserved for the I/O ports, with 2 terminals used for each input, and 2 terminals used for each output. Digital Input Digital ON and OFF determine which power input is used: On: +13 to +30 V for state 1 Off: +3 to -30 V for state 0 ) Digital Output The default for the relay output (DOUT) is open, indicating a normal condition. If the relay output (DOUT) is shorted, it indicates an exception. - 4 -

Adjustable pull high/low resistor for RS-485 Port DIP switches on the bottom of the OnCell G3100 are used to set the pull high/low resistor value for each serial port. SW 1 2 3 Pull High Pull Low Terminator ON 1 KΩ 1 KΩ 120 Ω OFF 150 KΩ 150 KΩ Hardware Installation Procedure STEP 1: Open the SIM cover, and insert the SIM card in the SIM card slot. STEP 2: Connect the 12-48 VDC power adaptor to the OnCell G3100 and then plug the power adaptor into a DC outlet. STEP 3: To configure the OnCell, use an Ethernet cable to connect the OnCell directly to your computer s Ethernet interface. STEP 4: Connect the OnCell G3100 s serial Ethernet port to a serial or Ethernet device. Software Installation Information The User s Manual, OnCell Search Utility, and OnCell Driver Manager can be downloaded from the Moxa website at www.moxa.com. Please refer to the User s Manual for additional details on using OnCell Search and Driver Manager. - 5 -

Pin Assignments and Cable Wiring DB9 Male Port Pinouts Note that the OnCell G3110 only supports RS-232. The RS-422/485 pin assignments only apply to the OnCell G3150. DB9 Male Pin RS-232 1 DCD 2 RxD 3 TxD 4 DTR 5 GND 6 DSR 7 RTS 8 CTS 9 4W/2W RS-485/RS-422 (Terminal Block) Pinouts Pin Power Input and Relay Output Pinouts Pin Name Function 1 V1+ DC Power input 1 2 V1-3 V2+ DC Power input 2 4 V2-5 Relay Output 6 7 I1 Digital Input 8 COM_1 Digital Input GND 9 I2 Digital Input 10 COM_2 Digital Input GND RS-422/485 4-wire RS-485 2-wire 1 TxD+(B) 2 TxD-(A) 3 RxD+(B) Data+(B) 4 RxD-(A) Data-(A) 5 GND GND Specifications LAN Interface Ethernet 10/100 Mbps, RJ45 connector Protection Built-in 1.5 KV magnetic isolation Cellular Interface (for OnCell G3110 & G3150) Standard Compliance GSM/GPRS/EDGE Band Selection Quad-band 850/900 MHz, and 1800/1900 MHz Tx Power 1 watt GSM 1800/1900, 2 watt EGSM 850/900 GPRS Multi-slot class Class 12 GPRS Terminal Device Class B GPRS Coding Schemes CS1 to CS4 SIM Control 3V - 6 -

Cellular Interface (for OnCell G3110-HSPA & G3150-HSPA) Data Rate UMTS (DL: 384 Kbps, UL: 384 Kbps) HSPA (DL: 14.4 Mbps, UL: 5.67 Mbps) Standard Compliance GSM/GPRS/EDGE/UMTS/HSPA Band Selection Five band 800/850/AWS/1900/2100 MHz Quad-band 850/900/1800/1900 MHz Tx Power 1 watt GSM1800, 2 watt GSM900, 0.25 watt UMTS/HSPA 0.5 watt EDGE900, 0.4 watt EDGE1800 GPRS Multi-slot class Class 12 GPRS Terminal Device Class B GPRS Coding Schemes CS1 to CS4 SIM Control 3V Serial Interface No. of Ports 1 Serial Standards OnCell G3100: OnCell G3150: RS-232 (DB9 male connector) RS-232 (DB9 male connector), RS-422/485 (5-pin terminal block connector) Serial Communication Parameters Parity None, Even, Odd, Space, Mark Data Bits 5, 6, 7, 8 Stop Bit(s) 1, 1.5, 2 (when parity = None) Flow Control RTS/CTS, XON/XOFF Speed 50 bps to 921.6 Kbps I/O Interface Alarm Contact 1 relay output with current carrying capacity of 1 A @ 24 VDC Digital Input 2 inputs electrically isolated from the electronics On: +13 to +30 V for state "1" Off: +3 to -30V for state "0" Power Requirements Input Voltage 12 to 48 VDC Data Link 400 ma (idle) to 900 ma (peak) @ 12 V Environmental Limits Operating temperature Standard: Wide Temperature: Storage temperature Regulatory Approvals EMC Warranty Warranty Period -30 to 55 C (-22 to 131 F), 5 to 95% RH -30 to 70 C (-22 to 158 F), 5 to 95% RH -40 to 75 C (-40 to 167 F) CE Class A, FCC Class A, UL 5 years - 7 -