ELECTRONIC DISPLAYS INC. 135 S. CHURCH STREET ADDISON, ILL

Similar documents
ELECTRONIC DISPLAYS INC. 135 S. CHURCH STREET ADDISON, ILL

Vorne Industries. 2000S Series Serial Input Alphanumeric Display User's Manual

Vorne Industries. Model 77/232 Serial Input Numeric 3" Display User's Manual

Microframe Corporation

VADDIO /CANON BU-SERIES PTZ CAMERAS

Mounting Dimensions / Viewing 2 Mounting Options 3. Wiring Configuration 4. Quick Set up Procedure 5. Changing Intensity 6.

MCCB-500 MOLDED-CASE CIRCUIT BREAKER TESTER

SERIES 208 INSTALLATION & OPERATING MANUAL

LNX Series Motor and Drives

CMSA-100 Manual. Cinema Media Server Automation

Installing Sentor. Hardware Installation

Mini Digital Multimeter

Vorne Industries. 87/415 Rate Monitor Display User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

User s Manual Hub444. Motion Control Network Hub

SCB-C08 USB to RS232/422/485 Converter

User s Manual. Revision 1.0. Copyright 2016 Maretron, LLP All Rights Reserved

Energy Management System. Operation and Installation Manual

OPERATING PROCEDURES for the UPS-S2 Universal Power Supply Series 2

I/O SIGNAL CONDITIONER

Installation & Operation

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

6222 Two Door Module Technical Operations Manual

Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

GOLANDER PUMP BQ80S Microflow Variable-Speed Peristaltic Pump Operation Manual

EVERSAN. Instruction Manual MODEL 9007/9008 TENNIS SCOREBOARD. Address: 34 Main Street, Whitesboro, NY 13492

E-ACLM-V E-ACLM-P12/8/18 AC LINE MONITORS Installation and Operation Manual

1:N REDUNDANT SWITCHING UNIT REMOTE CONTROL TERMINAL

OPERATING INSTRUCTIONS AND SERVICE MANUAL BASKETBALL SHOTCLOCK MODEL MP-5299

ELECTRO-MECH SCOREBOARD CO.

Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

Power Over Fiber USER GUIDE. SYSTEM INSTALLATION INFORMATION Description. The leader in rugged fiber optic technology. RLH Industries, Inc.

SNAP-IT-PM Installation Guide

Basketball Shot Clock Set LX2180 Manual

User's Guide. Digital Multimeter. Model MN42

EVERSAN. MODEL 9658 EVERSAN PERIOD INDOOR/OUTDOOR MULTI-FUNCTION SCOREBOARD. Instruction Manual

ST-PTZ High-Speed Intelligent Dome PTZ Color Camera

DUAL SWITCH CONTROLLER

AUD-340 Installation Guide

Table of Contents. Automatic Transfer Switch. User Manual ATS-16A/20A/30A/32A

Mounting the Model 2601

Instruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

MCCB-250 MOLDED-CASE CIRCUIT BREAKER TESTER

Model HM-535 Power Supply Installation and Service Instructions

Service Instructions. Conductor 420

1.6. Counters, Panel Meters, Tachometers and Timers. Contents Description Fusion Integrated Machine Control Standards and Certifications...

TOWN OF MANCHESTER GENERAL SERVICES DEPARTMENT 494 MAIN STREET P.O. BOX 191 MANCHESTER, CONNECTICUT

Quick Start Installation Guide

MODEL 9360-SO SOCCER SCOREBOARD

LN3X Series Motor and Drives

LPG STM 94442A User s Manual

Model DMX24DIM Installation and Operations Manual

MODEL 715AN QUADRATURE DEGREES COUNTER

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!

EtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X

Line Impedance Stabilization Network (LISN)

Mini Digital Multimeter

Mini Digital Multimeter

User s Guide. Pressure Controller for liquid delivery systems

Models DMX12DIM ELV Installation and Operations Manual

Model SAP612 Source Assign Panel User Manual

AEXX SERIES MULTI-FUNCTION CLOCK/TIMERS

2645 Series Counter Timers with 4 Tall Digits AF , AF , AF , AF

UT3620 Triple NT1 Installation Guide

The AF Counter Timer with PP D or PP A Firmware

PHASETRONICS. SCR Power Control Specialists. EP1 Series Power Control Single Phase SCR Amps OPERATION & SERVICE MANUAL

Manual for PSDC_OPT_EIGHT_01: Optics Power Supply

OPERATING MANUAL FOR LOGIC BASIC SERIES ELECTRONIC INDICATORS

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

CLEVELAND CONTROLS MODEL 6650 DIGITAL MANOMETER INSTRUCTION MANUAL DM

Operation Manual. Concorde 600 Power Supply. *This instrument is intended for laboratory use only.

Installing the DX LCD Display

Compact, Low Profile High Rendering, 100% Diffusion

AE21 SERIES DISPLAY CONTROL TERMINAL

AUD-220 Installation Guide

High Voltage DC Meter

DIN Rail Mounted Dial-up Modem Users Manual

RXTP ROOM TEMPERATURE

Product Manual 8330GMX

* * Agilent Power Distribution Unit (PDU) Installation Guide

MODEL 9386 MULTI-SPORT TIMER

Pow-R-Command 1000 universal I/O module

PD1100 STAND-ALONE PROGRAMMING & USER S GUIDE. use the freedom

PK2200 Series. Features. C-Programmable Controller. Specifications Board Size Enclosure Size Operating Temp.

VirtualSCADA VSU-485G USB to RS422/485 Isolated Converter User Manual

Vorne Industries. 87/708 Master Clock Display User's Manual

iq DIGITAL PICTURE FRAME iq Digital Picture Frame DPF701SB USER GUIDE

EP/2 Installation Instructions

Installation OVERVIEW

LED FOLDING WORKLIGHT TM

BCM2 Series Branch Circuit Monitors Quick Setup Guide

CAUTION CAUTION CAUTION HIGH VOLTAGE PRESENT

P/N Operation & Installation Manual Serial Control Transfer Switch Model TM-STS

SPX-7400_SPX-7410_MAN_161028

HuddleCamHD RS-232 Joystick Controller Model Number: HC-JOY

Mate Serial Communications Guide This guide is only relevant to Mate Code Revs. of 3.30 and greater

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE

Copyright Western Scale Co. Limited. All rights reserved.

THE CTB08D LIGHT CONTOLLER

AION LED WT SERIES. Custom Lengths. Made in the USA IP66* High Efficacy Exterior Rated Linear Fixture System

Transcription:

ELECTRONIC DISPLAYS INC. 135 S. CHURCH STREET ADDISON, ILL. 60101 www.electronicdisplays.com PRODUCT PART NUMBER : ED225MPC 2L N1-VERT-1001- KYN1 DESCRIPTION: Indoor 4 digit, 2.25 inch high, red LED, 2 line vertical display Top line is set up to be a fixed numeric value that will receive serial information via an EDI Supplied Keypad. (See the protocol sheet in this manual. Data input will be RS422 (2 wire transmission) @ 1200BPS ; NO PARITY ; 8 DATA BITS ; 1 STOP BIT. The 2 nd line is an up-counter by 1 w/ a reset to 0. ( 2 contact operation). Terminal block on the bottom right endplate is provided to wire a wet or dry contact closure and the keypad. (See wiring diagram inside this manual.) Power: 120 VAC @ 60Hz. ( 6 ft. line cord provided) NEMA 1 aluminum enclosure w/ white vinyl lettering. OPERATION: The top line of this scoreboard is designed to receive a serial input via an EDI supplied keypad. This line is set up to be fixed numeric value. See Appendix E in this document for setting the display with a keypad. The 2 nd line will count by 1 with a contact closure (switch, photo-eye etc.) and reset to 0 with a separate contact closure. Count for the middle line is labeled IN1 ; reset for the middle line labeled IN2. A terminal block is included to wire the contact closures to. Positions labeled VEXT GND IN1 & IN2 are used for these contact closures. By placing a momentary switch between VEXT and IN1 and IN2, the display will count by 1 and reset to 0. See the wiring diagram at the end of this manual. If there are any questions or comments regarding this order, please call our Toll-free number : 1-800 - 367-6056 page 1

Unpacking Instructions: A copy of these instructions is packed with each unit. Open carefully to avoid scratching the unit s paint and plastic lens or cutting the line cord. Mechanical Mounting Instructions: This unit is equipped with mounting tabs attached to the rear of the unit. The unit is designed to hang from a support or attached to a wall or support. Power Requirements: This unit is equipped with a standard, eighteen-gauge, three-wire line cord that is designed to be plugged into a standard, 120 VAC, 60 Hertz, grounded outlet. The maximum current draw for this unit (at 120 VAC) is _1.5 Amperes. Signal Requirements: If your unit has serial input (either RS-232, RS-422, RS-485, etc.), the standard communication format for this unit is 1200 bits per second (baud rate) with one start bit, eight data bits, no parity, and one stop bit per character. The expected sequence of characters is specified in a later section of this manual entitled Protocol. Product Components: See appendix A. Wiring Diagram: See appendix B. page 2

Label Definitions: The following page shows some commonly used labels and their definitions. Not all of these labels will be found in your unit. LABEL IN1, IN2, IN3, IN4 RX+ RX- TX+ TX- VEXT COMMON AC DEFINITION Optically coupled input, active high, requires 12 milli-amperes of current to activate. Positive side of balanced data line for RS-422 or RS-485 serial input signals Negative side of balanced data line for RS-422 or RS-485 serial input signals Positive side of balanced data line for RS-422 or RS-485 serial output signals Negative side of balanced data line for RS-422 or RS-485 serial output signals Positive voltage output terminal of the customer power supply. Negative voltage terminal of the customer power supply and common return for optically coupled inputs. Typically 10 to 12 VAC from EDI supplied transformer +V DC voltage supplied to displays GND AUX Ground for DC voltage above Ground supplied by way of 500 milli-ampere, NPN transistor AUX V+ +12 VDC to external load WARNING SHOCK HAZARD Always completely disconnect power from the display before opening the unit. Do not reapply power to the display until the unit has been securely closed. page 3

Customer Power Supply: If this unit is equipped with optically coupled inputs, these inputs prevent any electrical or electronic signal from passing directly from the outside world into the logic circuits on the printed circuit boards that we have supplied. For your convenience, we have also supplied this board with an isolated customer power supply that can be used to drive the customer side of these optically coupled inputs. This isolated supply does not have a direct current connection to the power supply that is used to power the display and logic chips. It will provide 12 VDC to 14 VDC at up to 500 milli-amperes of current. This voltage is unregulated. Dry Contact Configuration: To use dry contacts, the user need only supply a contact closure between the desired optically coupled input and the positive terminal of the isolated customer power supply. The negative terminal of the isolated supply is already connected to the negative side of each optically coupled input. See Figure A. (NOT USED) Vext OPTO GND INPUT1 INPUT2 DISPLAY Figure A Wet Contact Configuration: To use wet contacts, the user must supply his own power to activate the desired optically coupled input. The user may also wish to provide a contact closure in this circuit. The user s power supply must be capable of providing approximately twenty milli-amperes of current at 5 to 24 volts of direct current. If necessary, these inputs can also be ordered for use with higher voltages and / or with alternating current inputs. See Figure B. CUSTOMER'S POWER SUPPLY VOLTAGE - + (NOT USED) Vext OPTO GND INPUT1 INPUT2 DISPLAY (5-24VDC) Figure B page 4

Power-up Response: When power is first applied to this unit, the display will show zeros until data is received or the count input is activated. A value should be entered first on the top line. The bottom line will display the - of this value. Addressing: No addressing required. Baud rate of 1200BPS. Protocol: Appendix E - Protocol for Keypad Figure 1 below shows the layout of the older style keypads. Figure 2 below shows the layout of the newer style keypads. Note that the lettering differs between the keypads but the characters generated are the same on a position by position basis. Table 1 below and on the next page details what characters are generated. Figure 1 Figure 2 Common ASCII Characters: Here are some definitions of characters commonly used by EDI programs: CHAR VALUE DEFINITION / USE (decimal) <STX> 2 This is the standard ASCII character for start-of-text, also known as a Control B. It must be the first character in every message. If you are using an older style EDI keypad, the key labeled will send this character. If you are using a newer style EDI keypad, the key labeled A will send this character. This key will blank the LCD display. page 5

<ETX> 3 This is the standard ASCII character for end-oftext, also known as a Control C. It must be the last character in every most messages. If you are using an older style EDI keypad, the key labeled ENT will send this character. If you are using a newer style EDI keypad, the key labeled D will send this character. Until this key is pressed, the keys entered will flash on the LCD display. Once this key is pressed, the LCD display will show the keys entered solid. page 6

CHAR VALUE DEFINITION / USE (decimal) <LF> 10 This is the standard ASCII character for linefeed, also known as a Control J. It must be the last character in a few messages for some programs. If you are using an older style EDI keypad, the key labeled PRT will send this character. If you are using a newer style EDI keypad, the key labeled B will send this character. Note: This key is not used in this application. If it is pressed, the display will do nothing. <CR> 13 This is the standard ASCII character for carriage-return, also known as a Control M. It must be the last character in a few messages for some programs. If you are using an older style EDI keypad, the key labeled will send this character. If you are using a newer style EDI keypad, the key labeled C will send this character. Note: This key is not used in this application. If it is pressed, the display will do nothing. 0 9 48-57 These are the standard ASCII decimal digit characters used as data, and when needed, as addresses in messages. If you are using either style EDI keypad, the keys labeled 0 through 9 will send these characters. When any of these keys are pressed, the LCD display show them. * 42 This is the standard ASCII character for an asterisk. For the older EDI keypad, the key that represents an asterisk is labeled REV. For the new EDI keypad, the key is labeled *. Note: This key is not used in this application. If it is pressed, the display will do nothing. - 45 This is the standard ASCII character for a dash or minus sign. On the older EDI keypad, the key that represents a dash is labeled DEP. On the new EDI keypad, the key is labeled #. Note: This key is not used in this application. If it is page 7

pressed, the display will do nothing. Table 1 Example Messages: 1 If you wish to preset the "PLANNED" display set to address 01 to 1300, press the following sequence of keys: A 0 1 1 3 0 0 D (newer style) 2 If you wish to preset the "ACTUAL" display set to address 03 to 500, press the following sequence of keys: A 0 3 5 0 0 D Service: There are no parts in your unit classified as user serviceable parts. The plastic or glass cover can be cleaned using a soft cloth and a gentle glass cleaning solution. Warranty: The standard warranty for all products is one year on all parts and labor at our facilities. All products are designed and manufactured by Electronic Displays Inc. If you need assistance, please call or FAX us and we will be happy to provide technical assistance. If you feel that your unit needs repair, please call us first and then ship the unit to: Electronic Displays Inc. 135 South Church Street Unit A Addison, Ill. 60101 Attn: Repair department Our telephone number is: (630) 628-0658 Our FAX number is: (630) 628-0936 PROUDLY MADE IN THE U.S.A. page 8