485DRCI. Industrial RS-232 to RS-422/485 Converter B&B ELECTRONICS PRODUCT INFORMATION. Specifications Serial Technology

Similar documents
485DRCI. Industrial RS-232 to RS-422/485 Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter

MED102A. Industrial Serial to Single-mode Fiber Converter

ISOLATED RS-232 TO RS-422/485 CONVERTER

Industrial Isolated Converters

ICD200A Quick Start Guide. Convert RS-232 data signals to RS-422/485 signals in heavy industrial areas.

Black Box Tech Support: FREE! Live. 24/7.

MESR9xx. Vlinx Industrial MODBUS Ethernet to Serial Gateway B&B ELECTRONICS PRODUCT INFORMATION

MESR321. Vlinx Isolated Industrial Modbus Ethernet to Serial Gateway B&B ELECTRONICS PRODUCT INFORMATION

MESR Port Industrial Modbus Gateway. Specifications Power. MESR424_r000_2913ds

STEP X - Name of Step QUICK START GUIDE SP385A-R3, SP390A-R3 USB TO RS CONVERTER 24/7 TECHNICAL SUPPORT AT OR VISIT BLACKBOX.

MGate 5105-MB-EIP Quick Installation Guide

Media Converters. Media Converters. Product Selection Guides

MGate 4101-MB-PBS Series

MGate 5111 Quick Installation Guide

ICF-1150 Series Quick Installation Guide

Features and Benefits. Certifications

ADAM-4510 RS-422/RS-485 Repeater ADAM-4510S Isolated RS-422/485 Repeater ADAM-4520 Isolated RS-422/485 Converter Startup Manual

RS-232/RS-422 Optical Isolator

Miniature Asynchronous 4-Wire High Speed Modems

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features

Serial Communications Accessories SITRANS RD200/300. Operating Instructions 05/2013 SITRANS

Moxa TCC-100 Series Hardware Installation Guide

Quick Start Guide Elinx ESW200 Series. 5 and 8 port Unmanaged Ethernet Switch

Contents INTRODUCTION...1 CARD SETUP...2 INSTALLATION TECHNICAL DESCRIPTION SPECIFICATIONS... 14

Perle IDS-108F(XT) Unmanaged 10/100 Ethernet Switches. Installation Guide. P/N (Rev G)

VL BPC 100. Valueline configurable box PC. Data sheet 3063_en_E. 1 Description. 2 Features

EX KVIS RS232/422/485 3-in-1 Serial to USB Adapter (w/ 4KV Isolation, 15KV ESD Surge Protection)

Stride Industrial Ethernet Switches

Quick Start Guide Elinx ESW100 Series. 5 and 8 port Unmanaged Ethernet Switch

NPort 5400 Series Quick Installation Guide

Contents INTRODUCTION...1 CARD SETUP...2 INSTALLATION...9 TECHNICAL DESCRIPTION SPECIFICATIONS... 13

MEC-COM-M134. User s Manual

USB Connectivity. USB Connectivity

ICF-1150 Series Quick Installation Guide

Industrial Serial RS-232 to Fiber Converter. KSC-200 Series. Installation Guide

Serial Communication Converters & Adapters Instruction Manual

DIN-191 and DIN-192 SERIES CONVERTER BOXES USERS MANUAL

Manual Industry Interfaces

EMS467 Monitoring System. Installation and Operations Manual Section 40

TCNM-ACBB1 Installation Manual

Mini Driver V (Mini Driver MP with 5-Screw Terminal Block) MINI DRIVER MP

General Specifications. P2-SCM Serial Communications

USER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters

USB-TTL-5 PRODUCT IS A COMBINATION OF PRODUCTS USB AND TTL-232-5P BOTH DATASHEETS ARE INCLUDED IN THIS PDF FILE

Moxa TCC-100 Series User s Guide

JetCon 1100 / User s Manual. USB to Serial Converter series. Version 1.0

Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA. Features and Benefits. Certifications

GE Fanuc IC695CMM004. Rx3i PacSystem

The modems are made in industrial 108mm wide aluminium housing for DIN rail mounting. UCM RS232 interface

P3-SCM. General Specifications

EasySYNC Ltd. USB to Serial Converters Manual

FCC Information. RoHS This product is RoHS compliant. SJ/T The following contains information that relates to China.

EasySYNC Ltd. USB to Serial Converters Manual

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

IMC-101 Series Quick Installation Guide

VL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A.

CONTROL MICROSYSTEMS and 5601A Input/Output (I/O) Module. Hardware Manual

EasySync Ltd. ES-R-2x01-M RS232 to RS422 / RS485 Converter. User Guide. Document Reference No.: ES_ Version draft Issue Date:

MGate 5118 Quick Installation Guide

IDS-141A/181A. Industrial 4-port/8-port slim type serial to Ethernet device server. Features. Introduction. DS-Tool

NPort 5100 Series Quick Installation Guide

USB to RS-232/RS422/485. US-101-I USB To Serial Operation Manual

PCI Express 4-Port Industrial Serial I/O Cards

Product Manual. USB to Optical Adapter Industrial Isolated RS- 232/422/485. Coolgear, Inc. Version 2.1 December 2018 Model Number: USB-COMi-Si-M

iologik E1200H Series

CONTROL MICROSYSTEMS SDI-12 Interface Module. Hardware Manual

INTRODUCTION 2 FEATURES. 2 SPECIFICATIONS. 2 PIN ASSIGNMENT 2 DB-9 DB-25 CONVERSION TABLE. 2 DRIVER INSTALLATION QUICK GUIDE.. 2

SeaLINK+8/USB. Sealevel Systems, Inc 155 Technology Place P.O. Box 830 Liberty, SC USA

Features and Benefits. Certifications

Bluetooth to RS-232&RS422/485. EX-9132B/BI Bluetooth Adapter Operation Manual

MGate 5105-MB-EIP Series

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

RS-485 Products. ICP Electronics Australia Pty Ltd Communication Cards for PC/IPC P 2-1

Features and Benefits. Certifications

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)

Enhanced Mini-Chansim Model VCS-232

RTU560 Remote Terminal Unit Connections and Settings

MODBUS RTU I/O Expansion Modules - Models C267, C277, and C287. Installation and Operations Manual Section 50

NPort W2150A/W2250A Series Quick Installation Guide

PTC-101-M12 Hardware Installation Guide

E Serial Controller

Hardened Media Converter

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

USB to RS-232/RS422/485. URK-228-I USB To Serial Operation Manual

SER-4485-SI-M USER S MANUAL

User Guide. Westermo Teleindustri AB TD-29 DC. FSK-modem Multidrop 2-wire.

MODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

IMC-21 Quick Installation Guide

TRP-C08. USB to RS232/422/485 Isolated Converter. User s Manual. Printed Sep.2014 Rev 1.4

COMM+422.PCI USER MANUAL

1 to 16-port RS-232, RS-422/485, and RS-232/422/485 USB-to-serial converters. Features and Benefits. Certifications

MGate MB3170/MB3270 Quick Installation Guide

ULTRA 485 USER MANUAL

IFC-FDC-PRO PROFIBUS to Daisy Chain Fiber Converter. IFC-Serial-PRO PROFIBUS to Fiber Converter. Industrial Serial Fiber Converter

An ISO-9001 Certified Company

Modbus TCP/RTU Gateway

PCIe Card Selection Guide. PCIe-CAN Card. PCIe-COM Card. Taiwan Pulse Motion Co.,Ltd. Bus Interface PCI Express x 1 LPE-C122 PCE-C122D PCE-C122T

PCI Express 16-Port Serial I/O Cards

Transcription:

485DRCI RS-232 RS-485 2-Wrie RS-422/485 4-Wire RS-232 CON. RS-422/485 CON. Data Rate Isolation Surge Protection Industrial Bus Source Input Voltage Power Consumption Connector p/n 7207r3 485DRCI-4108ds page 1/5 Industrial RS-232 to RS-422/485 Converter Data Rates up to 115.2 Kbps 10 48 VDC Input Power Range Wide Operating Temperature 3-Way 2000V Optical Isolation Modbus ASCII/RTU Compatible UL Class 1 Division 2 The Ilinx 485DRCI is our premium Industrial RS-232 to RS-422/485 Converter. Designed for rugged industrial use, it is UL approved and certified for operation in Class 1 Division 2 environments. This DIN rail mountable converter optically isolates and converts unbalanced, full or half-duplex RS-232 signals to balanced RS-422/485 signals at baud rates up to 115.2 Kbps. In addition to optical isolation, the unit has surge suppression on the RS- 422/485 lines. Featuring Automatic Send Data Control circuitry, it does not require special software control of handshake signals in RS-485 mode. The removable terminal blocks for power and RS- 422/485 signals make wiring easy. It is powered by a supply voltage of 10 to 48 VDC which is isolated from all data and signal ground lines. Configuration is made easy with a 12 position DIP switch on the bottom of the converter. Remember, when it comes to reliable communications in harsh industrial environments, B&B Electronics Ilinx brand converters and isolators are your number one choice. Specifications Serial Technology TD, RD, GND Data A(-), Data B (+), GND TDA(-), TDB(+), RDA (-), RDB(+), GND DB9 Female (DCE) Removable Terminal Block, 28 to 14 AWG 1.2 to 115.2 Kbps 2000 V, 3-Way (Input, Output, Power) 600 W Peak Power Dissipation Clamping time < 1 pico-second MODBUS ASCII / RTU Power External 10 to 48 VDC 960 mw Removable Terminal Block, 28 to 14 AWG Mechanical LED Indicators Transmit, Receive, and Power Dimensions 4.5 x 1.3 x 4.9 in (11.4 x 3.3 x 12.4 cm) Enclosure 35mm DIN Mount, Plastic, IP30 Weight 0.45 lbs (204.12 g) Op TEMP Storage TEMP Op Humidity Environmental - 40 to 176 F (-40 to 80 C) - 40 to 185 F (-40 to 85 C) 0 to 95% Non-condensing Regulatory Approvals FCC, CE, cul, Class 1 Division 2 UL File Number E222870 (C1 D2 E245458) MTBF 254617 MTBF Calc. Method Parts Count Reliability Prediction Type Size Temperature Terminal Torque 485DRCI Accessories MDR-20-24 Class 1 DIV 2 Wiring Solid Copper Only 28 to 14 AWG 105 C (221 F) Minimum 0.5 Nm (Newton-meters) Ordering Information Ind. RS-232 to RS-422/485 Converter Ind. 24VDC 1A Slimline Power Supply

p/n 7207r3 485DRCI-4108ds page 2/5 Package Contents DIP Switch (SW1) 485DRCI Industrial RS-232 to RS-422/485 Converter Datasheet Power Terminal Block (installed) RS-422/485 Terminal Block (installed) If any item is missing or damaged, contact B&B Electronics for a replacement Special Precautions for Class 1 Div 2 Environment Special Instructions for Installation and Operation in a Class 1 DIV 2 Environment. 1. Power, input / output (I/O) wiring must be in accordance with Class 1 Division 2 wiring methods [Article 501.10(B) of the National Electrical Code, NFPA70] and in accordance with the local authority having jurisdiction. 2. WARNING EXPLOSION HAZARD: SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS 1, DIVISION 2. 3. WARNING EXPLOSION HAZARD: WHEN IN HAZARDOUS LOCATIONS, TURN OFF POWER BEFORE REPLACING OR WIRING MODULES 4. WARNING EXPLOSION HAZARD: DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NON-HAZARDOUS. 5. WARNING THIS APPARATUS IS SUITABLE FOR USE IN CLASS 1, DIVISION 2, GROUPS A, B, C, AND D, OR UNCLASSIFIED LOCATIONS. Front Panel 1 Power TB 2 Position, Removable 2 RD LED Red, Flashes when RS-422/485 Data Received 3 DB9 F RS-232 (Wired DCE) 4 422/485 TB 5 Position, Removable 5 TD LED Red Flashes when RS-422/485 Data Transmitted 6 Power LED Red, ON When Power Applied 7 Dip Switch 12 Position Pos ON OFF 1 RS-485 RS-422 2 Half Duplex Full Duplex 3 2-Wire 4-Wire 4 2-Wire 4-Wire 5 Termination In Termination Out 6 TX Bias In TX Bias Out 7 RXBias In RX Bias Out 8 2400 baud 9 4800 baud 10 9600 baud 11 19.2 k baud 12 38.4 k baud RS-232 DB9F (DCE) Pin Signal Direction 1 Receive Line Signal Detector (DCD) --- 2 Receive Data (RD) OUTPUT 3 Transmit Data (TD) INPUT 4 DTE Ready (DTR) --- 5 Signal Ground (SG) --- 6 DCE Ready (DSR) --- 7 Request to Send (RTS) --- 8 Clear to Send (CTS) --- 9 Ring Indicator (RI) --- 1. DB9 Female Connector is DCE. 2. Pin 2 (RD) is the Converter s RS-232 Data Output. 3. Pin 3 (TD) is the Converter s RS-232 Data Input. 4. Pins 1, 4, and 6 (DCD, DTR, and DSR) are jumpered together internally. 5. Pins 7 and 8 (RTS and CTS) are jumpered together internally.

p/n 7207r3 485DRCI-4108ds page 3/5 RS-422/485 Terminal Block Terminal RS-485 2-Wire RS-422/485 4-Wire A GND GND B Data B(+) RDB(+) C Data A(-) RDA(-) D --- TDB(+) E --- TDA(-) DIN Rail Mounting 1. Angle the top portion of the DIN mount over the top of DIN Rail. 2. Move the converter so that it is parallel with the DIN Rail. 3. Snap the bottom of the DIN mount in place. RS-422/485 Baud / Timeout Switch Selectable Baud SW1 SW1 SW1 SW1 SW1 Timeout (Kbps) 8 9 10 11 12 (ms) 2.4 ON OFF OFF OFF OFF 4.16 4.8 OFF ON OFF OFF OFF 2.08 9.6 OFF OFF ON OFF OFF 1.04 19.2 OFF OFF OFF ON OFF 0.580 38.4 OFF OFF OFF OFF ON 0.260 Resistor Selectable Baud Timeout (Kbps) SW1-8 through 12 R-11 Value (ms) 1.2 OFF 820 KΩ 8.33 57.6 OFF 16 KΩ 0.176 115.2 OFF 8.2 KΩ 0.087 1. Pre-defined baud rates are set using SW1 positions 8 through 12. 2. Resistor Selectable baud rates are set by inserting a through-hole resistor (R-11) on the circuit board. 3. WARNING EXPLOSION HAZARD: SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS 1, DIVISION 2. RS-485 2-Wire (Half Duplex) A, B, and C terminals. 2. Insert the RS-485 2-Wire signal leads. The terminal board accepts 28 to 14 AWG wire. In 2-Wire mode, Terminal B is tied to Terminal D and Terminal C is tied to Terminal E with DIP Switch SW1-3 and SW1-4.

p/n 7207r3 485DRCI-4108ds page 4/5 RS-485 4-Wire (Full Duplex) A, B, C, D, and E terminals. 2. Insert the RS-485 4-Wire signal leads. The terminal board accepts 28 to 14 AWG wire. RS-422 (Full Duplex) A, B, C, D, and E terminals. 2. Insert the RS-422 signal leads. The terminal board accepts 28 to 14 AWG wire.

p/n 7207r3 485DRCI-4108ds page 5/5 Power Loop Back Test 1. Loosen the screw to open the terminal block lead clamp. 2. Insert the power lead. TB will accept 28 to 14AWG wire. 3. Tighten the screw to close the terminal block lead clamp. Ensure the clamp holds the lead securely. However, do not over tighten. For Class 1 DIV 2 installations, ensure wiring is in accordance with the special precautions and specification table. Mechanical Diagram 1. Configure the converter for RS-485 4-Wire mode and the desired baud rate. 2. Place a jumper wire between the B and D terminals and the C and E terminals. 3. Connect a PC to the RS-232 port. 4. Using Hyper Terminal or similar program, connect to the appropriate COM port. Set the baud rate to match the converter. Ensure Hyper Terminal local echo is OFF. 5. Transmit data. If the same data is returned, the test is good.