User Manual. Open platform E Line. Part Number: Version: 1. Date:

Similar documents
User Manual. Cockpit. Part Number: Version: 3. Date:

User Manual. Quickstart KNX with TSwin.net. Part Number: Version: 2. Date:

User Manual. TSDiag+ Part Number: Version: 5. Date: TSDiag

User manual Quick start TSwin.net

Siemens Drives & PLCs

SIMATIC PC. Panel PC Industrial Lite Without Operating System. Preface, Table of Contents

PS-4700/4800Series User ユーザーマニュアル Hardware Manual Manual

SIMATIC HMI. Configuring Graphics Displays. Product Brief. Edition 12/01. Table of Contents. Introduction. Commissioning Operating Units

SIMATIC. STEP 7 PLUS TIA Portal Teamcenter Gateway. Introduction to TIA Portal Teamcenter Gateway 1. System requirements 2

PowerLogic TM Series EM4800 Multi-Circuit Meters. Configuration Guide

SINEMA Remote Connect - Client SIMATIC NET. Industrial Remote Communication SINEMA Remote Connect - Client. Preface. Requirements for operation

SIMATIC HMI. Software RemoteOperate V2. Preface. Overview 1. Range of functions of the RemoteOperate software. Hardware and software requirements

Software Kit. Automatic Door Controls. SIDOOR Software Kit. Introduction 1. General safety instructions. Installation. Uninstalling the software 4

Conext EasyConfig Tool

SIMATIC. SIMATIC Logon V User management and electronic signatures 1. Hardware and Software Requirements 2. Scope of delivery 3.

SIMATIC NET. Industrial Remote Communication - Remote Networks SINEMA Remote Connect - Client. Preface. Requirements for operation 1

PowerLogic TM Series E4800 Multi-Circuit Meters. Configuration Guide

DPoE Element Manager. Release Notes

Installing and starting up the AXC 1050 PN STARTERKIT. Quick start guide

Upgrading Software and Firmware

SIMOCODE pro. Read me SIMOCODE ES. Introduction 1. Installation notes 2. Installation/License key/ Uninstallation 3.

User Manual Connection to BRC-Symbolic

Preface 1. Storage System 2. Contact Information 3 SIPLUS CMS. SIPLUS CMS X-Tools - User Manual Storage System. English.

For safe and correct use, be sure to read the Safety Information in "Copy Reference" before using the machine. Network Guide

SIMATIC. S7/HMI SIMATIC Automation Tool V3.1 SP1 product information. SIMATIC Automation Tool features 1. Known problems. Product Information

Schneider Electric Floating License Manager

Quick Setup & Getting Started

IntelliTrack DMS (Data Management System) v8.1 Quick Start Guide Preliminary Copy (July 2011) Copyright 2011 IntelliTrack, Inc.

Setup Guide. Before Setting Up. Installation. Start-up/Shutdown

SIMATIC NET. Industrial Remote Communication - Remote Networks SINEMA Remote Connect. Preface. Connecting the SINEMA RC Server to the WAN 1

DriveWizard Plus Instruction Manual

SCADAPack E ISaGRAF Quick Start Guide

Addendum to Active Breathing Coordinator R3.0 Installation and Service. Installation Instructions for Windows 10

Agilent CytoGenomics 2.5

SIMATIC HMI. StoragePlus V1.3 SP1 / PCS 7 V7.1 MDM - Storage Plus Information System. StoragePlus Installation Instructions 1. StoragePlus Readme 2

SIMATIC Automation License Manager Manual 02/2008 A5E

Change Report Colors and Logo

suitedxt Instructions for Use NeoSoft, LLC NS Rev. 2 Copyright 2014 NeoSoft, LLC All rights reserved

Silex SD-320AN-03 Serial Server

Preface 1. Device Management System 2. Contact Information 3. User Manual Device Management System. English. Release

User Manual. Programming with TSwin. Part Number: Version: 4

Analog & Digital Output Module Quick Start Guide

Programming Manual KX-TVA50 KX-TVA200. Voice Processing System. Model

Agilent OpenLAB Chromatography Data System (CDS)

User Manual. Connection to Allen Bradley DF1. Part Number: Version: 2. Date: Valid for: TSwin.net 4.1x

for ColdFire Architectures V7.2 Quick Start

Network Guide NPD EN

Preface 1. Device Management System 2. Contact Information 3. User Manual Device Management System. English. Release

HT1000 Satellite Modem User Guide

USER MANUAL WINATEQ300 SOFTWARE Full version 1.01

SIMATIC PC. Panel PC 577 Installation Using the Docu & Drivers CD 10/2005. Preface, Table of Contents. Introduction 1.

FCWnx 7.7 Upgrade Manual

SIMATIC. SIMATIC Logon V1.6. Security information 1. Conditions for secure operation of SIMATIC Logon 2. User management and electronic signatures 3

Leica IP C and IP S. Printer Driver Software For the Windows 8.1 (32/64 bit) and Windows 10 (64 bit) operating systems

SIMATIC RTLS. Localization systems SIMATIC RTLS Locating Manager. Installation manual 10/2018 C79000-G8976-C536-01

Agilent OpenLAB Data Analysis Upload Download Tool. User s Guide

Lab - Data Migration in Windows

INSTALLING THE PS3 XBOX READY SOFTWARE:

SIMATIC PC. Panel PC 677 and PC 877 Installation Using the Docu & Drivers CD 04/2005. Preface, Table of Contents. Introduction 1.

How to Restore a Windows System to Bare Metal

Preface 1. Main Management System 2. Contact Information 3 SIPLUS CMS. SIPLUS CMS4000 X-Tools - User Manual Main Management System.

SICAT SUITE VERSION 1.0. Instructions for use SIDEXIS XG English

RFID Label Design and Encoding Management Pro (Utility Only) Installation Guide. October 2015 Version 1.21 A698HKV99-E-I-0121

Ethernet Modbus X80 Gateway Device Type Manager

User s Guide. CD Library II Software for Windows XP and Vista. CD Library II 4.0 Software CD Library software for CD Library products

DX200 OPTIONS INSTRUCTIONS

SIMATIC NET. Industrial Remote Communication TeleService TS Gateway. Preface. Application and properties. Installation, commissioning and operation 2

WinMarkpro v6 for the FH Marking Head Quick Start Guide

Siemens Distributor SIMATIC. WinAC MP for MP370 V3.1. Preface, Contents. Product Overview. Transferring WinAC MP to the Multi Panel

Getting Started - Startdrive. Startdrive SINAMICS. Introduction 1. Connecting the drive unit to the PC. Creating a project 3

Z8 Encore! XP/Z8 Encore! Development Kits

SIMATIC. Process Control System PCS 7 SIMATIC Management Console (V9.0) Security information 1. Preface 2. Basics 3

A698HKBH9-E-I RFID Data Management Pro for Fixed Readers Installation Guide. June 2017 Version 2.40

GP-N100 Utility Software Manual

Device Programming using TRWinProg

SIMATIC Industrial PC. Panel Drivers and Tools V1.3 PDT IFP Monitor Standard. Preface. Panel Drivers and Tools software. IPC Configuration Center

User Guide File Transfer Scheduler. LINAX Series LINAX A310 CAMILLE BAUER

SIMATIC. Process Control System PCS 7 SIMATIC Management Console (V9.0 Update 1) Security information 1. Preface 2. Basics 3

DDR. User s Guide ND040012E. We reserve all rights in this document and in the information contained therein. Copyright 2014 Newcon Data AB

FAS Asset Accounting FAS CIP Accounting FAS Asset Inventory Installation & Administration Guide Version

NEC Versa 4200 Windows 98 Upgrade Information

Agilent OpenLAB Chromatography Data System (CDS)

Ethernet Smart Cable

CodeWarrior Development Studio for Freescale 68HC12/HCS12/HCS12X/XGATE Microcontrollers Quick Start SYSTEM REQUIREMENTS Hardware Operating System 200

mce100+ getting started guide Install mce100+ The disc will run and display the below screen: Choose Install mce to continue

Agilent 89600B VSA. Software Installation Guide

MULTIFUNCTIONAL DIGITAL COLOR SYSTEMS. Software Installation Guide ES9466 MFP/ES9476 MFP

MULTIFUNCTIONAL DIGITAL SYSTEMS. Software Installation Guide

DigidownHost. Software User s Guide. Lisle Design Ltd 2014 Subject to change without notice

Network planning tool for Phoenix Contact wireless products. User manual

SFC Visualization (V8.0 SP1) SIMATIC. Process Control System PCS 7 SFC Visualization (V8.0 SP1) What's new in SFV? 1. SFC Visualization (SFV)

LCON Parameterizable Converter

Setup Guide. Operating Instructions. 1 Before Setting Up 2 Installation 3 Start-up/Shutdown

Magnetek Material Handling IMPULSE LINK 4.1 Basic Instruction Manual

Conext CL-60 EasyConfig Tool

SIMATIC. Process Control System PCS 7 VT Readme V8.2 (online) Security information 1. Overview 2. Notes on Installation 3. Notes on usage 4.

SIMATIC. Process Control System PCS 7 CFC Readme V9.0 (online) Security information 1. Overview 2. Notes on Installation 3. Notes on usage 4.

Datacard XPS Card Printer Driver Guide

Installing TAM Air Assistant Software TM

Centra Workbench (V3.12 onwards)

Transcription:

User Manual E Line Part Number: 80860.850 Version: 1 Date: 2014-01-27 Valid for: SB7ECS-OPENPLATL-0007

Version Date Modifications 1 2014-01-27 First edition This manual, including all illustrations contained herein, is copyright protected. Use of this manual by any third party in departure from the copyright provision is forbidden. No part of this manual may be reproduced, translated or electronically or photographically archived or altered without the express written consent from Sütron electronic GmbH. Violations shall be cause for damage liability. Sütron electronic reserves the right to make any changes that contribute to technical improvement.

Overall Table of Contents 1 Important Notes... 4 1.1 Symbols... 4 1.2 Safety Notes... 4 1.3 Intended Use... 4 1.4 Target Group... 5 2 Introduction... 6 2.1 Hardware and Software Requirements... 6 3 PC Configuration... 7 4 Operating Device Configuration... 8 4.1 IP Address... 8 4.2 Connection to Visual Studio... 10 5 Visual Studio... 11 5.1 Create Project... 11 5.2 Device Settings... 12 5.3 Library for Device Functions... 14 5.4 Debugging / Deploying Project... 15 6 Extended Configuration... 16 6.1 Starting Project Automatically... 16 6.2 Device Backup / Restore... 17 A Index... 18 3

Important Notes 1 Important Notes 1.1 Symbols The symbols in this manual are used to draw your attention on notes and dangers. This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. DANGER This indicates a hazardous situation which, if not avoided, will result in death or serious injury. WARNING This indicates a hazardous situation which, if not avoided, could result in death or serious injury. CAUTION This indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. NOTICE This symbol together with the signal word NOTE and the accompanying text alert the reader to a situation which may cause damage or malfunction to the device, hardware/software, or surrounding property. This symbol and the accompanying text provide the reader with additional information or refer to detailed sources of information. 1.2 Safety Notes Read this manual carefully before using the software. Keep this manual in a place where it is always accessible to all users. The user manual, in particular the safety notes, must be observed by all personnel working with the software and the programmed device. Observe the accident prevention rules and regulations that apply to the operating site. Installation and operation must only be carried out by qualified and trained personnel. 1.3 Intended Use The software has to be used for programming operating devices exclusively. Every other use is not permitted. 4

Important Notes 1.4 Target Group All configuration and programming work in connection with the automation system must be performed by trained personnel only (e.g. qualified electricians, electrical engineers). The configuration and programming personnel must be familiar with the safety concepts of automation technology. 5

Introduction 2 Introduction This manual describes the configuration of Sütron operating devices with an open platform in use with the development environment of Microsoft Visual Studio. 2.1 Hardware and Software Requirements The descriptions in this manual presuppose basis knowledge in handling Windows as well as programming knowledge which cannot imparted in this manual. If you should have any questions regarding this, we refer to the manuals for Windows or its online help.your computer should at least have the following hardware and software requirements: Computer with 1.6 GHz or better, 512 MByte main memory (RAM) or better, 100 MByte free hard disk memory, CD-/DVD drive, mouse, Windows XP / Windows Vista / Windows 7 Microsoft Visual Studio 2005 / 2008 Professional or Visual Studio Team System 2005 / 2008 6

PC Configuration 3 PC Configuration A requirement for creating a project in Visual Studio is the Sütron SDK for the E Line. The SDK must be installed to support the E Line as target platform. Install SDK 1. Start the installation file DK7ECS-ELINEARMV4I-xxxx.msi on your PC. 2. Perform a complete installation of the SDK. 7

Operating Device Configuration 4 Operating Device Configuration 4.1 IP Address To enable access to the operating device the following conditions must be filled: The operating device is connected with a network cable An ip address is configured or was allocated by the DHCP server Some settings are password-protected. The default password is "+-+-". Use the cockpit to display or adapt the ip configuration of the operating device. Start cockpit at system startup To start the cockpit, do the following: 1. Wait during the startup phase until the following dialog is displayed: Figure 4-1 Cockpit startup phase 2. Press the button to start the cockpit before the progress bar is down. You can customize the language of the cockpit interface at the language menu item. 3. Press the button Language Selection. 4. Select the desired language. 5. Confirm your selection with the green check. Using desktop icon to start cockpit You can start the cockpit via the desktop icon at already started operating devices with active desktop: 1. Briefly press twice on the desktop icon. 2. Press the button to start the cockpit before the progress bar is down. You can customize the language of the cockpit interface at the language menu item. 3. Press the button Language Selection. 8

Operating Device Configuration 4. Select the desired language. 5. Confirm your selection with the green check. Calling network settings Assign IP manually 1. Press the Network button. Following information is displayed: IP address,, Subnet mask, Gateway, Physical address (MAC) If no DHCP server is present or the IP address should be assigned manually, proceed as follows: 1. Select the option use static IP. 2. Assign an ip address, subnet mask and gateway for the operating device. 3. Confirm your selection with the green check. Assign IP automatically With an existing DHCP server the IP address can be assigned automatically. 1. Select the option Use dynamic IP (DHCP). 2. Confirm your selection with the green check. 3. Press the Network button and read the assigned IP address. Please see further documentation to the configuration and administration from the device-specific user manual. 9

Operating Device Configuration 4.2 Connection to Visual Studio The operating device is configured per default for a connection with Visual Studio 2008. To make this connection, a batch file (project.bat) is available in the flash memory of the device. Execute project.bat To make the connection to Visual Studio possible, execute the file project.bat: 1. Briefly press twice on the desktop icon. 2. Press the button to start the cockpit before the progress bar is down. 3. Press the button Administration. Some settings are password-protected. The default password is "+-+-". 4. Press Administration to activate the area. 5. Press the Start Batch File button. The batch file is executed. 6. Close the Cockpit. The debug connection is closed automatically after long inactivity. In this case execute the file project.bat again to re-establish the connection. 10

Visual Studio 5 Visual Studio 5.1 Create Project Open Visual Studio and create a new project as follows: 1. Click in the menu File -> New on the entry Project... Figure 5-1 Project type 2. Choose the branch Visual C# -> Smart Device in the area Project types. The template Smart Device Project should already be selected automatically. 3. Click on the button OK. Figure 5-2 Add new Smart Device Project 4. Select the target platform DK7ECS-ELINEARMV4I, the Compact Framework Version 3.5 and the template Device Application. 5. Click on the button OK. Visual studio creates an empty form for the application. To adapt the application to the proportions of the target device, carry out the following steps: 1. Mark the form Form1. 11

Visual Studio 2. Select the entry Size from the property window and type in the width and height of the resolution of your operating device in pixels. Please read the resolution of the display from the product specific user manual. 5.2 Device Settings To connect Visual studio with the operating device, the following settings must be carried out: 1. Click on the button Device Options. Figure 5-3 Device options 2. Select the branch Devices from the Device Tools tree. 3. Mark the entry DK7ECS-ELINEARMV4I in the Show devices for platform list box. 4. Select DK7ECS-ELINEARMV4I ARMV7 Device as Default device. 5. Click on the button Properties... Figure 5-4 Device settings, properties 12

Visual Studio 6. Click on the button Configure... Figure 5-5 Device settings, configure TCP/IP transport 7. Select the option use specific IP address and enter the IP address of the operating device. 8. Confirm all dialogs with the button OK. To define the output folder for the project, you still have to carry out the following steps: 1. Click on the entry ProjectName Properties... in the Project menu. 2. Select the tab Devices. Figure 5-6 Project properties, devices 3. Remove the hook of the check box Deploy the latest version of the.net Compact Framework (including service packs). 4. Click on the button... on line Output file folder. Figure 5-7 Project properties, output file folder 13

Visual Studio 5. Select the entry Root Folder from the list box Location of output on device. 6. Enter the device memory and the project name to the field subdirectory (for example \FlashDrv\SmartDeviceProjectOP ). With the appropriate paths, different memory areas of the operating device can be accessed. Some paths are dependent on the product line of the operating device: Product line(s) Memory type Path All USB stick \HardDisk\ S Line, E Line, M Line, PLine Internal \FlashDrv\ E Line, M Line, P Line Memory card \StorageCard\ 7. Click on the button OK. 5.3 Library for Device Functions The installed SDK makes a library available for the access to device functions additionally. You have to add an reference to the library to use it in Visual Studio: 1. Click on the Add Reference... button in the project menu. 2. Click on the Browse tab. 3. Navigate to the following directory: C:\Program files\windows CE Tools\SDKs\DK7ECS-ELINEARMV4I\Dll\ARMv4I\ 4. Select the file SuetronDevice.dll. 5. Click on the OK button. 14

Visual Studio 5.4 Debugging / Deploying Project The configuration of the operating device and Visual studio makes it possible to debug or deploy your project now. Debugging To transfer and debug the project to the operating device, you proceed as follows: 1. Click on the button Start Debugging. Figure 5-8 Debug project 2. Click on the button Deploy. The project is transferred to the defined place and started. Deploying You can deploy the project also at the configured place: 1. Select the menu item Deploy Solution in the Build menu. Figure 5-9 Deploy project 2. Click on the button Deploy. The project is transferred to the defined place. 15

Extended Configuration 6 Extended Configuration 6.1 Starting Project Automatically After the booting procedure the file starter.bat is automatically executed. You can use it to start the project automatically. The project files should be copied and executed to the RAM memory for this purpose. This accelerates the access and prevents, that the project files - for example for updates - are blocked if these are executed at the moment. You can modify the file starter.bat as follows: 1. Open your FTP program or the Windows Explorer and enter the ip address of the operating device as address (Example: ftp://149.208.160.232). 2. Download the file starter.bat to your local file system. 3. Extend the batch file with an editor (for example: Notepad): REM Starter.bat REM This batch-file will automatically start the application upon boot. REM 1. Copy data from remanent storage to RAM disc REM (remanent storage is either at: REM \FlashDrv REM 2. Start application executable REM prepare directories for application in RAM disc md \SmartDeviceProjectOP REM copy application files from remanent storage to RAM disc copy \FlashDrv\SmartDeviceProjectOP\*.* \SmartDeviceProjectOP REM start application at RAM disc cd \SmartDeviceProjectOP start SmartDeviceProjectOP.exe 4. Save the batch file. 5. Upload the file to the operating device with the FTP program again and overwrite the old version. At the next start of the operating device the project is copied automatically and then started. 16

Extended Configuration 6.2 Device Backup / Restore A backup / restore of data (for example: Project data, start-up configuration etc.) in the permanent memory (Flash) on a USB stick is created as follows: 1. Start the cockpit. 2. Press the menu option Update. Some settings are password-protected. The default password is "+-+-". 3. Press the Backup area. Backup Backup Device 1. Insert a USB stick into the female connector of the operating device. 2. Press the button Backup Device. The files are copied to the directory "Backup" on the USB stick. If there is already a "Backup directory with data on the USB stick the backup is not performed. The successful backup will be confirmed with a dialog. Restore Backup NOTICE When restoring the backup all data in the flash memory of the operating device will be deleted. The process of backup and restore all settings is possible only with identical device types. 1. Insert a USB stick into the female connector of the operating device. 2. Press the Restore Backup button. NOTICE Do not interrupt the power supply during the process. After canceling an process, the operating device may not be operational anymore. The backup files are copied from the directory "Backup" to the flash memory of the operating device. The successful update will be confirmed with a dialog. 3. Restart the operating device. 17

A Index B Backup...17 E Extended configuration...16 H Hardware requirements...6 I Important notes...4 Intended use...4 IP address...8 O Operating device Configure...8 S Safety notes...4 Software requirements...6 T Target group...5 V Visual Studio...11 Create project...11 Debug project...15 Deploy project...15 Device settings...12 18