SmartPro 3U Rack/Tower Extended-Run UPS Line-interactive, sine wave UPS Model #: SMX5000XLRT3U 5000VA 230V Sine Wave Expandable Rack/Tower UPS; all-in-one chassis requires 3 rack spaces total Battery-independent AVR corrects brownouts to 170V and overvoltages to 282V Multiple interfaces: USB, DB9 (serial & contact closure), SNMPWEBCARD Slot 11 outlets (3 C19, 8 C13) Hardwire input 2-year warranty E-mail us your critical extended run application requirements for large kva and extended run UPS Systems and we will research the ideal solution and provide a custom configuration. Contact a Tripp Lite Product Specialist DESCRIPTION 5000VA line-interactive UPS for server, network and telecommmunications equipment / UPS with internal batteries requires 3 rack spaces installed / Accepts 230V nominal input voltage / Corrects brownouts and overvoltages from 170V to 282V / Sine wave output / Uninterruptible Power Supply (UPS) maintains battery-derived AC output during blackouts and severe voltage fluctuations / Expandable runtime with optional external battery packs / 11 output receptacles / Hardwire input connection / Network-grade AC surge and noise suppression / Network management interfaces include USB, DB9 serial/contact closure and SNMPWEBCARD slot / Supports simultaneous detailed monitoring of equipment load levels, self-test data and mains power conditions via all network interfaces simultaneously / Includes PowerAlert monitoring software and complete cabling / Emergency Power Off (EPO) interface / 3-stage metered current monitoring and battery charge LEDs / Mains power and voltage regulation LEDs / Audible alarm / Self-test / 4-post rack mounting accessories / 2-9USTAND and 2POSTRMKITWM accessories available / Field-replaceable, hot-swappable internal batteries and battery packs / Attractive all-black color scheme / 2-year warranty KEY BUYING POINTS 5000VA/3750W max. output power capacity compatible with International 230V 50/60Hz input voltage 3U rack/tower UPS installs in standard 19-in. rack enclosures with an installed depth of only 75cm Protects sensitive networking equipment from blackouts, voltage fluctuations and transient surges Line-Interactive Automatic Voltage Regulation (AVR) corrects 230V nominal input from 170-282VAC back to usable 230V levels without consuming battery power AVR circuits boost undervoltages from 170V to 199V by 12% and reduce overvoltages from 245V to 282V by 12% Network interfaces support simultaneous communications via USB, DB9 serial or contact closure and SNMPWEBCARD slot Included PowerAlert UPS monitoring software supports safe unattended shutdown, monitoring and control via local connected servers, plus any number of additional servers over IP Communications ports support on-battery, low-battery, power-restored, AC-voltage, DC-voltage, output current monitoring, battery charge current, battery capacity, internal UPS temperature, AC line frequency, timed inverter shutoff and activate self-test Built-in Emergency Power Off (EPO) interface with cable Sine wave output in AC and battery modes Expandable runtime with optional BP48V60RT3U external battery packs Half/full load runtime of 27/10 min. with internal batteries Includes 11 output receptacles (3 C19; 8 C13) Hardwire input AC connection 3-stage metered LEDs offer current monitoring and battery charge level Mains power and voltage regulation LEDs offer at-a-glance power status information Front panel switches support self-test and alarm cancel functions
Included adjustable mounting rails support installation in 4-post 19-in. racks Supports 2-post rackmount installation with optional 2POSTRMKITWM accessory Supports upright tower placement with optional 2-9USTAND accessory CE, GOST, SASO listed 2-year manufacturer's product warranty TYPICAL APPLICATIONS Ideal for protection of sensitive electronics in any application calling for upright tower or 19-in. rackmount UPS installation. Common applications include any mix of servers, workstations, hubs, routers, concentrators, IP telephony and traditional PBX switching systems OPTIONS & ACCESSORIES External battery pack: BP48V60RT-3U SNMP accessories: SNMPWEBCARD, ENVIROSENSE USB Hubs-accessories: U202-004-R, U205-004-R, U022-010 Dataline protectors: DNET1, DTEL2, DCATV Rack enclosures: Rack Systems Power distribution: PDU12IEC Tower stands: 2-9USTAND Two post rackmount kit: 2POSTRMKITWM PACKAGE INCLUDES SMX5000XLRT3U UPS System PowerAlert Software and cabling Mounting hardware for 4-post rackmount installation Warranty information Instruction manual COMPLETE SPECIFICATIONS SYSTEM OVERVIEW System overview: Voltage compatibility: Frequency compatibility: OUTPUT Output volt amp capacity (VA): 5000 Output watt capacity (watts): 3750 Output nominal voltage: Output voltage regulation: Output frequency regulation: SmartPro line-interactive 3U expandable rack/tower UPS 230V nominal 50/60Hz (Auto-sensing) 230V Outlet quantity / type: 11 total (3 C19, 8 C13) LINE MODE: Sine wave line voltage 230V (+8% / -17%), BATTERY MODE: Sine wave 230V (+/-5%) LINE MODE: Passes line frequency of 50/60Hz +/-10%, BATTERY MODE: Inverter output regulated to 50/60Hz (+/-0.5Hz) Overload protection: 5 built-in output circuit breakers (3 x 15A; 2 x 10A) INPUT Maximum input amps: Input connection type: 27A Hardwire
BATTERY Full load runtime: Half load runtime: Expandable battery runtime: DC system voltage: Typical battery lifespan: 10 min. (5000VA), 37 min. with 1 BP48V60RT3U battery pack 27 min. (2500VA), 78 min. with 1 BP48V60RT3U battery pack Yes, with optional BP48V60RT3U external battery packs 48VDC 3-6 years, depending on usage Battery recharge rate: 2-4 hours to 90% VOLTAGE REGULATION Voltage regulation description: Automatic Voltage Regulation (AVR) circuits maintains clean, regulated computer-grade 230V nominal output, without consuming battery power, during brownouts to 170V and overvoltages to 282V Overvoltage correction: Input voltages between 245 and 282 are reduced by 12% Direct pass through: Input voltages between 200 and 244 are passed through to connected equipment unchanged Brownout correction: Input voltages between 170 and 199 are boosted by 12% LEDS ALARMS & SWITCHES Front panel LEDs: Alarms: Switches: SURGE / NOISE SUPPRESSION AC surge suppression: AC suppression response time: EMI / RFI AC noise suppression: PHYSICAL 5 front panel LEDs Green POWER LED, Green VOLTAGE CORRECTION LED, 3-color BATTERY CHARGE LED, 3-color OUTPUT LOAD LED, red BATTERY WARNING LED 3-function audible alarm indicates power failure conditions (4 short beeps every 10 seconds), overload (continuous short beeps) and low battery (continuous tone) Yes, includes 2 front panel-mounted push button switches for system enable, self-test and alarm cancel functions 480 joules Instantaneous Yes Shipping weight (lbs): 182 Shipping weight (kg): 82.6 Unit weight (lbs): 143 Unit weight (kg): 64.9 Unit Dimensions (HWD/in): 5.25 x 17.5 x 25 Unit Dimensions (HWD/cm): 13.3 x 44.5 x 63.5 Shipping Dimensions (HWD/in): 11.25 x 31.5 x 23 Shipping Dimensions (HWD/cm): 28.6 x 80 x 58.4 Material of construction: Form factors supported: Cooling method: Battery Access: ENVIRONMENTAL Operating Temperature: Storage Temperature: Relative Humidity: COMMUNICATIONS Steel Rack/Tower (3U) Set of 2 built-in cooling fans Battery access door allows hot swap battery replacement without powering connected equipment off +32 to +104 degrees Fahrenheit +5 to +122 degrees Fahrenheit 0 to 95%, non-condensing
Network monitoring port: Software and cabling included: SNMP compatibility: WatchDog compatibility: LINE / BATTERY TRANSFER Transfer time from line power to battery mode: Low voltage transfer to battery power: High voltage transfer to battery power: CERTIFICATIONS Certifications: WARRANTY Product warranty: SPECIAL FEATURES EPO port: TVSS grounding: Cold Start: Appearance: BATTERY PACK ACCESSORY (optional) Battery Pack Accessory (optional): Includes built-in USB and DB9 serial ports, Each supports on battery, low battery, power restored, AC line voltage, DC battery voltage, load percentage, battery charge current, battery capacity, internal UPS temperature and line frequency status messaging. Interface supports timed inverter shutoff after unattended shutdown, activate self-test and 10 second reboot of connected equipment. Supports reboot of all connected devices at once via software interface. Additional DB9 port supports standard UPS contact closure messaging; compatible with Tripp Lite's PowerAlert Software. Includes PowerAlert UPS monitoring software for all common network and stand-alone operating systems. Ships with USB and DB9 serial cables Built-in accessory slot accommodates internal SNMP/Web card and other network accessories Yes, compatible with Tripp Lite's Watchdog system service to restore operation to locked equipment through soft reboot of applications/os or hard power off/on reboot of connected equipment; ideal for unattended kiosk applications 2-4 milliseconds 170VAC (resets to line power as voltage increases to 179VAC) 282V (resets to line power as voltage decreases to 274VAC) CE, GOST, SASO, RoHS compliant 2-year product warranty Includes RJ-11 EPO (emergency power off) port and interconnection cable Includes back panel grounding point with thubscrew for dataline surge suppressors and other network accessories requiring a safe grounding point Yes, inverter can be cold started to enable temporary AC output during a power failure Attractive all-black color scheme BP48V60RT3U
The policy of Tripp Lite is one of continuous improvement. Specifications are subject to change without notice. Therefore, your product may vary slightly from what is currently listed. 2006 Tripp Lite. All Rights Reserved.