MCD 200 MCD 500. Remove the Profibus Module using the following procedure: 1. Remove power from the module.

- 15G0078B110 - PROFIBUS MODULE INSTRUCTIONS FOR ASAC-0/ASAC-1/ASAB

It is the installer's responsibility to follow all instructions in this manual and to follow correct electrical practice.

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Copyright: December 2017 Nidec Issue: E

VersaMax IP Input Module

EL731 PROFIBUS INTERFACE

DF PROFI II PCIe. Installation Instructions V Project No.: 5302 Doc-ID.: DF PROFI II PCIe KUNBUS

DF PROFI II CPCI. Installation Instructions V Project No.: 5302 Doc-ID.: DF PROFI II CPCI KUNBUS

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

SBPC-21-PB FifeNet to Profibus Gateway

PROFIBUS-DP/MODBUS RTU REPEATER

RS485 MODBUS Module 8I8O

RS485 MODBUS Module 8AO

Anybus Communicator STARTUP GUIDE. IIoT. SP en-us ENGLISH

SK TU4-PBR Part number:

ICPDAS FSM-510G Series Ethernet Management Switch Quick Start

SK CU4-PBR-C Part number:

INSTRUCTION MANUAL WCS-Interface Module, DeviceNet

SDM-8AO. Expansion Module 8 analog outputs. Manufactured for

crio PN Installation Instructions V0.2/ COMSOFT

User Manual BLCDP-2M12MT-2RFID-S

TB3P/TB4P I/O PROFIBUS DP FIELDBUS MODULE FOR PNEUMATIC MANIFOLD VALVES. Pg. 1 di 14

MGate 5102-PBM-PN Series

SMART RELAY SRW 01 V4.0X

CVIC II - CVIL II - CVIR II - MULTICVIL II - Memory Mapping - Manual

SCHMIDT Sensor interface PROFIBUS Instructions for use

TURCK Modular Industrial I/O PROFIBUS -DP Products

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

Serial PROFIBUS Interface

Anybus X-gateway. PROFIBUS Master Interface NETWORK GUIDE SCM EN 1.0 ENGLISH

1. Installation DEVICENET INTERFACE. Install the DeviceNet Interface using the following procedure:

MGate 5111 Quick Installation Guide

Pulsar EXtreme 2000/3000 VA

FSM-510G Series Ethernet Management Switch Quick Start Guide

This device can be installed by anyone on the condition that he/she has READ THE USER AND SAFETY MANUAL CAREFULLY.

PAC BI-DP BIM and 8701-CA-BI Carrier

RS485 MODBUS Module 16I-M

DeviceNet Module. User Manual. 1 Important User Information. 2 Installation

- 15G0078B120 - DEVICENET MODULE INSTRUCTIONS FOR ASAC-0/ASAC-1/ASAB

Motors Automation Energy Transmission & Distribution Coatings. Profibus DP SRW 01. User s Manual

Our Company is a specialist in the design, development and manufacturing of uninterruptible power supplies (UPS).

EX-RC1 Remote I/O Adapter

Modbus TCP/RTU Gateway

PROFIBUS DP/CAN Gateway PCA-100. User Manual

RS485 MODBUS Module 8I8RO

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System

Diagnostics (Physical)

Commander compact. Commander compact Lines displays. System SLIO. System 100V. Lines displays Commander compact 603-1CC CC21.

Hardware Manual RM CANview

MODBUS RTU MODULE INSTRUCTIONS. for use with WSIQ2/WSE

MGate 4101-MB-PBS Series

CEM M-RS485 INSTRUCTION MANUAL (M014B A)

8~14-Port Managed Ethernet Switch

G5 Weighing Instrument

Real Time Clock with Temperature Sensor and RS485/Modbus Comunications

Copyright: December 2017 Nidec Issue: E

DVPPF02-SL PROFIBUS DP Slave Communication Module

Installation manual Digital Energy USB / RS232 / Relay Interface Card for use with GE Digital Energy VH Series UPS VA

It is the installer's responsibility to follow all instructions in this manual and to follow correct electrical practice.

Gateway 1400 Reference Manual

NMID. Remote control. SAPIM I/O number. SAPIM I/O number NBRN (RS485) ZM100. Relay, 24 VDC - + UO07 UI11 UI10 UI09 UI08 UI07 UI06 UI05 UI04 UI03 UI02

MC 11 EB-2 Power supply cabinet with external bus, AC version

Data sheet VIPA CPU 115DP (115-6BL22)

Profinet Module. User Manual. Contents

EX-RC1 Remote I/O Adapter

User manual BLCDN-8M12LT-8XSG-PD-8XSGPD

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

XPSMCMx Fieldbus Expansion Modules Instruction Sheet (Original Language)

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

mark150s mark150/485s DDC controllers Summary

FC8x. Profibus Communication

OPERATING INSTRUCTIONS MCD

S SENECA. Installation Manual Z-TWS4. Z-PC Line. Web Multifunction Controller Straton / Linux

THOR Modular. Modular UPS system. Online double-conversion Scalable Decentralized Parallel. Modular. 10, 20, 30, 40kVA modules kVA systems

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

RS 485 Mini Modbus 1AO

MRUC-20 Modul-R CAN Bus Network

Operating and mounting instructions

EX-RC1 Remote I/O Adapter

User Guide Automatic Transfer Switch (ATS)

NA-9171 / 9173 (RS-232) (RS-485) User Manual. MODBUS Adapter CREVIS Co.,Ltd. Version FnIO MODBUS Adapter NA-9171, NA-9173 FnIO S-Series

485DRCI. Industrial RS-232 to RS-422/485 Converter B&B ELECTRONICS PRODUCT INFORMATION. Specifications Serial Technology

Install the DeviceNet Module using the following procedure:

Energy Management Energy Transducer Type ET112

Instruction Manual Power Distribution System SVS16-PN-XX

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter

CANopen IO X2 Fact sheet

RTD-W Installation Instructions

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual

Operation manual. HDOM-Profibus-V0. More options please visit;

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

RS485 MODBUS Module 6RO

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Transcription:

INTRODUCTION Thank you for choosing our product. The accessories described in this manual are of the highest quality, carefully designed and built in order to ensure excellent performance. This manual contains detailed instructions on how to install and use the product. This manual must be stored in a safe place and CONSULTED BEFORE USING THE DEVICE for proper usage instructions as well as maximum performance from the device itself. NOTE: Some images contained in this document are for informational purposes only and may not faithfully demonstrate the parts of the product they represent. SAFETY This part of the manual contains SAFETY precautions that must be followed scrupulously. Ensure that the connectors subjected to high voltages are correctly isolated. The device has been designed for professional use and is therefore not suitable for use in the home. The device has been designed to operate only in closed environments. It should be installed in rooms where there are no inflammable liquids, gas or other harmful substances. Take care that no water or liquids and/or foreign bodies fall into the device. In the event of a fault and/or impaired operation of the device, do not attempt to repair it but contact the authorized service centre. The device must be used exclusively for the purpose for which it was designed. Any other use is to be considered improper and as such dangerous. The manufacturer declines all responsibility for damage caused by improper, wrong and unreasonable use. ENVIRONMENTAL PROTECTION Our company devotes abundant resources to analysing environmental aspects in the development of its products. All our products pursue the objectives defined in the environmental management system developed by the company in compliance with applicable standards. Hazardous materials such as CFCs, HCFCs or asbestos have not been used in this product. When evaluating packaging, the choice of material has been made favouring recyclable materials. Please separate the different material of which the packaging is made and dispose of all material in compliance with applicable standards in the country in which the product is used. DISPOSING OF THE PRODUCT The device contains internal material which (in case of dismantling/disposal) are considered TOXIC, such as electronic circuit boards. Treat these materials according to the laws in force, contacting qualified centres. Proper disposal contributes to respect for the environment and human health. The reproduction of any part of this manual, even in part, is prohibited unless authorised by the manufacturer. The manufacturer reserves the right to change the product described at any time without prior notice for improvement purposes. - 3 -

INDEX PRESENTATION 5 IN THE BOX 5 EXTERNAL VIEW 5 PROFIBUS DP GATEWAY CONNECTORS AND LEDS 6 PROFIBUS CONNECTOR 6 POWER CONNECTOR 6 MULTICOM 302 CONNECTOR 6 STATUS LEDS 6 MULTICOM 302 JUMPER AND DIP SWITCHES SETTINGS 7 INSTALLATION 7 PROFIBUS CONFIGURATION SWITCHES 8 CONNECTION CABLE MULTICOM 302 PROFIBUS DP GATEWAY 8 DIN RAIL MOUNTING 8 PROFIBUS I/O DATA 9-4 -

PRESENTATION MultiCOM 411 is a complete PROFIBUS-DP slave according to IEC 61158. It allows to integrate the management and monitoring of the UPS into a PROFIBUS network. Baud rates from 9.6 kbit/s up to 12 Mbit/s are supported and automatically detected. IN THE BOX MultiCOM 302 board PROFIBUS DP Gateway Connection cable between MultiCOM 302 and PROFIBUS DP Gateway EXTERNAL VIEW PROFIBUS Connector Configuration Switches Status LEDs Reserved MultiCOM 302 Connector Power Connector DIN-rail Connector - 5 -

PROFIBUS DP GATEWAY CONNECTORS AND LEDS PROFIBUS CONNECTOR PIN Signal Description Housing Shield Bus cable shield, connected to PE 1, 2, 7, 9 - - 3 B-Line Positive RxD/TxD (RS485) 4 RTS 1 Request To Send 5 GNDBUS 2 Isolated GND from RS-485 side 6 +5V BUS 2 Isolated +5 V output from RS-485 side (80 ma max) 8 A-Line Negative RxD/TxD (RS485) 1 May be used by some devices to determine the direction of transmission 2 Used for bus termination; may also be used to power optical transceivers (RS485 to fibre optics) 5 1 9 6 (female) POWER CONNECTOR PIN Description 1 2 1 +24 VDC (300 ma required) 2 GND Note: no power supply is provided with the device. MULTICOM 302 CONNECTOR PIN Description 5 1 1, 2, 3, 4, 6, 7-5 Signal Ground 8 RS485+ 9 RS485-9 6 (female) STATUS LEDS # State Status 1 - PROFIBUS Online Off Not online Green Online 2 - PROFIBUS Offline Off Not offline Red Offline 3 - (Not used) - - 4 - PROFIBUS Diagnostic 5 - Subnet Status 6 - Device Status Off Red, flashing 1Hz Red, flashing 2Hz Red, flashing 4Hz Off Green, flashing Green Red Off Alternating Red/Green Green Green, flashing Red Red, flashing No diagnostics present Error in configuration Error in user parameter data Error in initialization Power off Running correctly, but errors occurred Running Subnet error Power off Invalid or missing configuration Initializing Running Bootloader mode Contact support department - 6 -

MULTICOM 302 JUMPER AND DIP SWITCHES SETTINGS INSTALLATION 1. Remove the cover of the UPS expansion slot by removing the two retaining screws. 2. Insert MultiCOM 302 in the slot. 3. Fix the cover provided using the screws previously removed. 4. Connect the PROFIBUS DP Gateway to the MultiCOM 302 using the cable provided with the device. NOTE: if necessary, you can also use another cable realized in accordance with the specifications (see Connection cable MultiCOM 302 PROFIBUS DP Gateway). 5. Set the PROFIBUS node ID (see Configuration Switches). 6. Connect the PROFIBUS DP Gateway to the PROFIBUS DP Network. 7. Connect the power cable and apply power. - 7 -

PROFIBUS CONFIGURATION SWITCHES The configuration switches are used to set the PROFIBUS node address. Remove the plastic hatch to configure the switches (see image below). Note that the node address cannot be changed during runtime, i.e. the gateway requires a reset for changes to have effect. The configuration is done using two rotary switches as follows: Node Address = (Switch B x 10) + (Switch A x 1) Note: When removing the hatch and configuring the switches, avoid touching the circuit boards and components. Example: If the node address should be 42: set switch A to 2 and switch B to 4. CONNECTION CABLE MULTICOM 302 PROFIBUS DP GATEWAY DB9 male PIN connect to RJ-45 PIN 5 2 9 3 8 4 NOTE: Use a twisted pair to connect PIN #9 and #8 of DB9 to PIN #3 and #4 of RJ-45 DIN RAIL MOUNTING To snap the gateway on, first press it downwards (1) to compress the spring in the DIN-rail mechanism, then push it against the DIN-rail as to make it snap on (2). To snap the gateway off, push it downwards (1) and pull it out from the DIN-rail (2), as to make it snap off from the DIN-rail. - 8 -

PROFIBUS I/O DATA The UPS s values are presented to the Master PLC/Controller as easily processed I/O data. INPUT DATA REGISTER # BYTE # High Low DESCRIPTION UNIT 1 1 2 States / alarms 1 2 3 4 States / alarms 2 3 5 6 Charge% % 4 7 8 Autonomy Minutes 5 9 10 RESERVED 6 11 12 Load phase L1 % 7 13 14 Load phase L2 % 8 15 16 Load phase L3 % 9 17 18 Input voltage (Ph-N) V1 V 10 19 20 Input voltage (Ph-N) V2 V 11 21 22 Input voltage (Ph-N) V3 V 12 23 24 Input frequency Hz/10 13 25 26 Output voltage (Ph-N) V1 V 14 27 28 Output voltage (Ph-N) V2 V 15 29 30 Output voltage (Ph-N) V3 V 16 31 32 Output frequency Hz/10 17 33 34 Output current phase L1 A/10 18 35 36 Output current phase L2 A/10 19 37 38 Output current phase L3 A/10 20 39 40 Output peak current phase L1 A/10 21 41 42 Output peak current phase L1 A/10 22 43 44 Output peak current phase L1 A/10 23 45 46 Battery current of positive bench A/10 24 47 48 Battery current of negative bench A/10 25 49 50 Battery voltage of positive bench V/10 26 51 52 Battery voltage of negative bench V/10 27 53 54 Output active power phase L1 kw/10 28 55 56 Output active power phase L2 kw/10 29 57 58 Output active power phase L3 kw/10 30 59 60 Output apparent power phase L1 kva/10 31 61 62 Output apparent power phase L2 kva/10 32 63 64 Output apparent power phase L3 kva/10 33 65 66 Bypass voltage (Ph-N) V1 V 34 67 68 Bypass voltage (Ph-N) V2 V 35 69 70 Bypass voltage (Ph-N) V3 V 36 71 72 Bypass frequency Hz/10 37 73 74 System temperature C - 9 -

INPUT DATA REGISTER # BYTE # High Low DESCRIPTION UNIT 38 75 76 RESERVED 39 77 78 Battery temperature C 40 79 80 Power 1 temperature C 41 81 82 Power 2 temperature C 42 83 84 Power 3 temperature C 43 85 86 Input current phase L1 A/10 44 87 88 Input current phase L2 A/10 45 89 90 Input current phase L3 A/10 46 91 92 RESERVED 47 93 94 RESERVED 48 95 96 RESERVED 49 97 98 Output nominal voltage V 50 99 100 Output nominal frequency Hz/10 51 101 102 Output nominal power kw/10 52 103 104 Output nominal power kva/10 53 105 106 Battery nominal voltage V 54 107 108 Battery nominal capacity Ah 55 109 110 RESERVED 56 111 112 Time from last valid UPS data processed Seconds 57 113 114 Echo of command code Integer 58 115 116 Echo of shutdown delay time Seconds 59 117 118 Echo of restore delay time Minutes Command result: 0x0F00 Ready to receive command 60 119 120 0x0100+Command Code Command code is wrong 0x0200+Command Code Command is not handled 0x0300+Command Code Parameter out of range (Reg. 116) 0x0E00+Command Code Command sent to the UPS 61 121 122 RESERVED 62 123 124 RESERVED 63 125 126 RESERVED 64 127 128 RESERVED 65 108 129 130 RESERVED Integer Some measures may not be available for all the UPS. In this case, the relative register remains at 0xFFFF value. STATES / ALARMS 1 BIT # DESCRIPTION 15 (MSB) Output powered [0=NO / 1=YES] 14 UPS locked [0=NO / 1=YES] 13 Battery working [0=NO / 1=YES] 12 Battery low [0=NO / 1=YES] 11 On bypass [0=NO / 1=YES] 10 9 Normal operation [0=NO / 1=YES] 8 7 Bypass bad [0=NO / 1=YES] 6 Battery charging [0=NO / 1=YES] 5 Battery charged [0=NO / 1=YES] 4 3 Shutdown active [0=NO / 1=YES] 2 1 Test in progress [0=NO / 1=YES] 0 (LSB) - 10 -

STATES / ALARMS 2 BIT # DESCRIPTION 15 (MSB) UPS failure [0=NO / 1=YES] 14 Alarm overload [0=NO / 1=YES] 13 Alarm temperature [0=NO / 1=YES] 12 Input mains present [0=NO / 1=YES] 11 10 9 8 7 6 5 4 3 2 1 0 (LSB) REGISTER # BYTE # High Low 1 1 2 OUTPUT DATA DESCRIPTION Command Code: 0 (0x0000) Get ready to receive a new command 1 (0x0001) System Shutdown (see also register 2) 2 (0x0002) System Shutdown & Restore (see also register 2-3) 3 (0x0003) Delete Commands 1 & 2 12 (0x000C) UPS on Bypass 20 (0x0014) Test Battery UNIT Integer 2 3 4 Shutdown delay time Seconds 3 5 6 Restore delay time Minutes NOTE 1: write always 0x0000 in Command Code after executing a command in order to get ready the device to accept the next command. NOTE 2: before executing a new command, you can check if the device is ready to accept it by verifying that Command Result = 0x0F00 (INPUT DATA register 60) NOTE 3: write in register 2 and 3 ( Shutdown delay time and Restore delay time ) before writing in register 1 for executing a system shutdown or a system shutdown & restore otherwise, writing in register 2 and 3 will have no effect. Example of Power OFF the UPS in 3 minutes and Power ON after 8 hours (System Shutdown & Restore): Check that "Command Result" (INPUT DATA register 60) is equal to 0x0F00. Write 0x00B4 in Shutdown delay time (output data / register 2) Verify that "Echo of shutdown delay time" (INPUT DATA register 58) is equal to the value sent. Write 0x01E0 in Restore delay time (output data / register 3) Verify that "Echo of restore delay time" (INPUT DATA register 59) is equal to the value sent. Write 0x0002 in Command Code (output data / register 1) Verify that command result is 0x0E02 (input data / register 60) Write 0x0000 in Command Code (output data / register 1) - 11 -

Example of master configuration to have accesso to UPS state and commands Example of master configuration to have accesso to all UPS measurements and commands Example of master configuration to have access to the UPS input data register from n 1 to n 16-12 -