Agilent MassHunter Qualitative Data Analysis

Similar documents
Agilent MassHunter Workstation Software 7200 Accurate-Mass Quadrupole Time of Flight GC/MS

Agilent MassHunter LC/SQ ChemStation Integration Software

Agilent 6400 Series Triple Quadrupole LC/MS System

Agilent Triple Quadrupole LC/MS Peptide Quantitation with Skyline

Agilent MassHunter Metabolite ID Software. Installation and Getting Started Guide

Agilent G2727AA LC/MS Data Browser Quick Start

MassHunter File Reader

Protein Deconvolution Quick Start Guide

Retention Time Locking with the MSD Productivity ChemStation. Technical Overview. Introduction. When Should I Lock My Methods?

Thermo Xcalibur Getting Started (Quantitative Analysis)

MassHunter Personal Compound Database and Library Manager for Forensic Toxicology

Agilent G6854 MassHunter Personal Pesticide Database

TraceFinder Analysis Quick Reference Guide

Agilent MassHunter Workstation Software Report Designer Add-in

Agilent G6854AA MassHunter Personal Compound Database

Panorama Sharing Skyline Documents

TraceFinder Analysis Quick Reference Guide

Agilent 6300 Ion Trap LC/MS Systems Quick Start Guide

Agilent 5977 Series MSD System

Skyline Targeted MS/MS

Agilent EZChrom Elite. PDA Analysis

Data Handling and Reports

Xcalibur Library Browser

Tutorial 7: Automated Peak Picking in Skyline

Agilent G6825AA METLIN Personal Metabolite Database for MassHunter Workstation

Agilent ChemStation Plus

Agilent 5977 MSD Overview

AutoCAD 2009 User InterfaceChapter1:

Using OPUS to Process Evolved Gas Data (8/12/15 edits highlighted)

Galaxie Photodiode Array Software

MRMPROBS tutorial. Hiroshi Tsugawa RIKEN Center for Sustainable Resource Science MRMPROBS screenshot

Getting Started. Environmental Analysis Software

MRMPROBS tutorial. Hiroshi Tsugawa RIKEN Center for Sustainable Resource Science

EZ IQ. Chromatography Software PN P1A

Agilent OpenLAB CDS. Version 2.2. Release Notes. OpenLAB CDS Release Notes 1

Agilent MassHunter Easy Access Software

Tutorial 2: Analysis of DIA/SWATH data in Skyline

Title: Release of MassHunter Quantitative Analysis B SP1 Build 388.1

Agilent RapidFire 300 High-throughput Mass Spectrometry System

PDA EXTENSION. Clarity Extension. Code/Rev.: M054/80A Date: 6/8/2018. Fax: Petrzilkova 2583/ Prague 5

REVIEW. MassFinder 3. Navigation of the Chromatogram

Agilent EZChrom Elite. User s Guide

StarFinder. Operation Manual. Star Chromatography Workstation Version 6

Skyline irt Retention Time Prediction

Tutorials. Saturn GC/MS Workstation Version 5.4. Varian Analytical Instruments 2700 Mitchell Drive Walnut Creek, CA /usa

OpenLynx User's Guide

Q Exactive HF-X Software Manual

2 The Stata user interface

DataPro Quick Start Guide

Import and preprocessing of raw spectrum data

Data Acquisition with CP-2002/2003 Micro-GC Control

Thermo Scientific. GRAMS Envision. Version 2.1. User Guide

Discovering Computers & Microsoft Office Office 2010 and Windows 7: Essential Concepts and Skills

Skyline MS1 Full Scan Filtering

Agilent MassHunter Drug Analysis Mode Using Quantitative Analysis Workflow Guide

Getting Started with DADiSP

Xcalibur. QuickQuan. User Guide. XCALI Revision C July For Research Use Only Not for use in Diagnostic Procedures

Procedures for Group Quantitation

Process Eye Professional. Recall

Getting Started. Custom Reports Software

UPDATING PESTICIDE RETENTION TIME LIBRARIES FOR THE AGILENT INTUVO 9000 GC

Skyline Targeted Method Refinement

Skyline Targeted Method Refinement

The walkthrough is available at /

Chromeleon / MSQ Plus Operator s Guide Document No Revision 03 October 2009

Quick Guide to the Star Bar

Progenesis LC-MS Tutorial Including Data File Import, Alignment, Filtering, Progenesis Stats and Protein ID

Table of Contents. Chapter 2. Looking at the Work Area

ChromQuest 5.0 Quick Reference Guide

Building Agilent GC/MSD Deconvolution Reporting Libraries for Any Application Technical Overview

MassHunter Pesticides PCD or PCDL Quick Start Guide

Store and Report Waters Empower Data with OpenLAB ECM and OpenLAB ECM Intelligent Reporter

To get started download the dataset, unzip files, start Maven, and follow steps below.

Skyline High Resolution Metabolomics (Draft)

Agilent 6100 Series Quad LC/MS System

TraceFinder Shortcut Menus Quick Reference Guide

Agilent ChemStation Plus

Agilent G6855AA MassHunter Personal

Concordance Basics. Part I

Agilent G2721AA Spectrum Mill MS Proteomics Workbench Quick Start Guide

Agilent G1701DA GC/MSD ChemStation

QuiC 1.0 (Owens) User Manual

Agilent MassHunter Workstation Software for Triple Quad LC/MS

Agilent G1701DA GC/MSD ChemStation

Chromatography Software Training Materials. Contents

Thermo Scientific. GRAMS Envision. Version 2.0. User Guide. Revision A

Microsoft How to Series

DATASTREAM CHART STUDIO GETTING STARTED

Manual. User Reference Guide. Analysis Application (EMG) Electromyography Analysis

67 Series Spectrophotometer PC Software

Welcome to noiselab Express 1.0

Reference Manual MarkerView Software Reference Manual Revision: February, 2010

cief Data Analysis Chapter Overview Chapter 12:

How to do a Property Search

Using Open Workbench Version 1.1

Introduction to Excel

Quick Start Guide. Introduction. Importing Raw Data. Method 1: Use Open Data Panel

Performing a resequencing assembly

SystemVue 2011 Fundamentals (version ) LAB EXERCISE 1. SystemVue Basics

Managing Content with AutoCAD DesignCenter

Transcription:

Agilent MassHunter Qualitative Data Analysis Qualitative Navigator B.08.00 Presenters: Kevin Costalunga Stephen Harnos With Matt Leyden & Kevin Costalunga 1 MassHunter Webinar Series

MassHunter Qualitative Navigator Topics Navigator and Workflows Navigator View Adaptive User interface Methods Definition Unified Method Concepts Working with Chromatograms Anchoring Integration peak List Working with Spectra MS Display Options Background Subtraction Annotations of Chromatograms and Spectra Library Searching and Annotations 2 MassHunter Webinar Series

MassHunter Qualitative Analysis Software B.08.00 SP1 Navigator and Workflows Navigator User centric Interactive Browsing Walk the Chromatogram Spectrum Preview Spectrum ID Library/Database Search Molecular Formula Generator No concept of compounds No Feature Finding Find by What does the chromatography look like? System Suitability What is the mass spectrum for each peak? Can the spectrum be identified by searching a library? Workflows Compound centric Automated Routine Workflows Sample Purity Compound Discovery Compound Identification Feature Finding Find by No Spectrum Preview No User Spectra All spectra are compound based. What compounds can be found and identified? 3 MassHunter Webinar Series

MassHunter Qualitative Analysis Software B.08.00 SP1 Navigator and Workflows Navigator Workflows File opens in Workflows. The same chromatogram(s) extracted. Spectra not extracted. Method is NOT passed to other context. File opens in Navigator. The sample chromatogram(s) are extracted. No compound results. Method is NOT passed to other context. 4 MassHunter Webinar Series

MassHunter Qual - Configurable Software One program for many instruments and types of data. Single Quad (LC & GC) Scan, SIM data Triple Quad (LC & GC) Scan, SIM, MRM (MS/MS)data TOF (LC) High resolution, scan Q-TOF (LC & GC) High resolution MS/MS data Qualitative Analysis B.08.00 features the Adaptive User Interface based on the type of data file opened, MassHunter will attempt to configure the interface with the appropriate options. The interface can still be manually configured if necessary. Even when properly configured some features and parameters for MS/MS and accurate mass are still visible, ignore and avoid them. 5 MassHunter Webinar Series

User Interface Configuration Separation types (Check GC or LC) Unit Mass (SQ, TQ) Accurate Mass (TOF, QTOF) Check Show Advanced Settings from the Configuration menu to access the User Interface Configuration MS Levels: MS or MS/MS 6 MassHunter Webinar Series

Navigator View Data Navigator Chromatogram Results Method Editor Spectrum Results 7 MassHunter Webinar Series

Data Navigator The Data Navigator pane shows the data files which are loaded into Qualitative Navigator. The user can selectively display the chromatograms or spectra associated with a data file by selecting/deselecting a checkbox. In the top drop-down, the user can choose to sort by Data File or Type. 8 MassHunter Webinar Series

Expose or Hide Windows as Needed From the Menu or from the Toolbar 9 MassHunter Webinar Series

Docking & Undocking Windows 10 MassHunter Webinar Series

Restore Default Layout Complicated windows layouts can be restored to default layout. Preferred layouts can be saved and loaded. Layouts can be locked. 11 MassHunter Webinar Series

Restore Qual Setting or Located in the Tools for Qualitative Analysis B.08.00 folder. Accessed from Start Menu or the Agilent MassHunter Workstation desktop folder. This can be a useful tool to restore the Qualitative Analysis settings if a configuration problem is suspected. 12 MassHunter Webinar Series

Open Data Files Select multiple files at once for batch analysis, then click Open. If Load result data is checked, the qualitative data manipulations previously saved will be loaded. New in B.08.00 SP1 - If Run method workflow is checked, automated processing is performed. If neither Load result data or Run method workflow is checked, then a TIC is automatically extracted from the data files. 13 MassHunter Webinar Series

Qualitative Analysis Methods Open Method Open Method Load the method relevant to the data set. Method contains recommended/default parameters. Method Editor values can be modified. Saves time developing specific values. Good starting point. Default-GCMS-SQ.M GCMS and GC QQQ Default-GCMS.M GC QTOF Default-LCMS.M LCMS 14 MassHunter Webinar Series

Refresh Data File File > Refresh Data File Feature is useful when it is desired to view data as the data file is being acquired. Initially use Open Data File as normal to view data file being acquired. Then use Refresh Data File to update the view and add the most recently acquired data. Refresh Data File is only active if the file is being acquired. Similar application use for the GC/MSD ChemStation, where it is called SnapShot. 15 MassHunter Webinar Series

Qualitative Analysis Methods Qualitative Analysis Methods are stored in a.m folder. Many application & instrument specific methods, generally use the method specific to the dataset.. Default.M is read-only, after editing Save As to a customized method. 16 MassHunter Webinar Series

What is a Method? Unified Method Concept Qualitative Analysis Navigator and Workflows Methods are stored in a.m folder. Quantitative Analysis Methods are stored in a.m folder. Quantitative Analysis Reporting Methods are stored in a.m folder. Unified method can now be automated to run from the sequence/worklist. 17 MassHunter Webinar Series

Method Editor Adaptive User Interface simplifies Method Editor 18 MassHunter Webinar Series

Method Editor View > Method Editor Expand nodes on the left side and select a section to edit. Tabs within a section further organize method parameters. The Run icon executes the function associated with the selected part of the method. In some cases the Run icon can have different actions, a drop down list will them display them for selection. 19 MassHunter Webinar Series

Relationship Between Action and Method Editor Main Menu Right Click Menu Run Button Set parameters for action in Method Editor. Then, perform action. Note : The action will be performed on ALL selected (highlighted) items! 20 MassHunter Webinar Series

Change and Error Icons When you make a change to the current method the change is marked. In addition, all other functions that are affected by this change will be marked. Save the method to remove the icon. An invalid value has been entered into a field. The field will reset to the last valid value it contained. Additional information is required. The error must be fixed before the algorithm will execute. 21 MassHunter Webinar Series

Let s take a moment for questions on Configuration and Methods. Up Next: Working with Chromatograms 22 MassHunter Webinar Series

Working with Chromatograms The power of Qualitative analysis is that you can have more than 1 data file open at a time. Extract Chromatograms from Data Files. Displaying Chromatograms Selecting for display Zooming Scaling Overlay / List mode Anchoring 23 MassHunter Webinar Series

Chromatograms Can Display: TOF Data QTOF Data QQQ Data SQ Data UV data FID Data Data Loaded & Displayed 24 MassHunter Webinar Series

Extract Chromatogram Available Chromatogram types are determined by data in file. 25 MassHunter Webinar Series

Selecting Chromatograms for Display Items in the Data Navigator, like Chromatograms, will be displayed if checked and not displayed if unchecked. 26 MassHunter Webinar Series

Specify Number of Chromatograms Displayed Maximum number of chromatograms to display in window, may be fewer. 5 Chromatograms Selected 5 Chromatograms Selected Scroll bar appears when there are more selected chromatograms than can be displayed 27 MassHunter Webinar Series

Overlay vs. List Mode Chromatograms List (Separated) Overlaid 28 MassHunter Webinar Series

Anchoring Anchored Scroll through other chromatograms Setting an anchor keeps the anchored chromatogram displayed at all times. Only one Chromatogram can be anchored at a time. The anchor can be set and cleared from the context menu. 29 MassHunter Webinar Series

Zooming Right-click and drag over the desired area or right-click in the axis and drag to zoom. Autoscale Normalization Unzoom (multiple levels) Linked Y-axis Scale to largest in Each over Selected Range Scale to largest in Each Scale to largest in All Scale Off 30 MassHunter Webinar Series

Chromatogram Display Options Main Menu Show Advanced Settings is checked. Within Toolbar Customize Appearance of Chromatograms 31 MassHunter Webinar Series

Extraction Data Format - Profile and Centroid Data files may contain Centriod, Profile (Raw) or both data types. Settings determine which type is used to create chromatograms / spectra. Centroid data is the most commonly used, ~10 times smaller than Profile Profile is useful for mass peak area comparisons such as when optimizing acquisition parameters, i.e. finding the mass defect or center of mass centroid How is Profile Data activated? 32 MassHunter Webinar Series

Extract Additional Chromatograms Software extracts a list of chromatograms which are stored in the Additional Chromatograms section of the method. List of Chromatogram types is fixed list of all instrument types. 33 MassHunter Webinar Series

Extract Additional Chromatograms Select MS Level based on acquisition scan type. Types of Chromatograms TIC Total Ion Chromatogram BPC Base Peak Chromatogram EIC Extracted Ion Chromatogram SIM Selected Ion Monitor Other Chromatograms GC, DAD, ADC Instrument Curve (LC) - %Comp., Temps, etc. Triple Quad systems only MRM Multiple Reaction Monitor pnlc - Precursor Neutral Loss Chromatogram 34 MassHunter Webinar Series

Extracting GC, UV and other Non-MS Signals Before SP1, files with only non-ms signals needed to have the signals extracted manually. With SP1, files with no MS signal automatically extract chromatograms when opened. 35 MassHunter Webinar Series

Integrate Chromatogram Independent Integrator for each signal. 36 MassHunter Webinar Series

Integrators Agile2 3 rd generation parameter-less integrator Default Integrator Better baselines, higher sensitivity to smaller peaks Agile 2 nd generation parameter-less integrator Universal 1 st generation ChemStation integrator Familiar to GC LC ChemStation users General (RTE) Familiar to MSD ChemStation users Areas in Universal are 10 time smaller than seen in ChemStation MS/MS and MS/MS (GC) 1 st generation parameter-less integrator intended for MS/MS systems, not recommended for SQ. Originally required 64 data points. ChemStation 2 nd generation ChemStation Intended for UV 37 MassHunter Webinar Series

Integration Peak List Right-click on the Peak List header to Add/Remove Columns. Columns can be moved by clicking and dragging on column header. 38 MassHunter Webinar Series

Manual Integration Use mouse cursor to manually integrate peak. 39 MassHunter Webinar Series

Calculate Signal-to-Noise Specific Noise Regions User defined specific noise regions. May be performed automatically when Chromatogram is integrated. 40 MassHunter Webinar Series

Let s take a few moments for questions on Working with Chromatograms. Up Next: Working with Mass Spectra 41 MassHunter Webinar Series

Mass Spectral Display Options 42 MassHunter Webinar Series

Spectra Display MS Spectrum Results Spectrum Results Selected Extracted spectra are displayed and sent to the Data Navigator. Spectra can be saved with the data file. 43 MassHunter Webinar Series

Extract Single Spectrum Extract Spectra Double-click on chromatogram or Right-click on chromatogram then, Extract Spectrum. 44 MassHunter Webinar Series

Extract Averaged Spectra Use Select Range tool then drag across region for spectral averaging. Double-click to view averaged spectrum. 45 MassHunter Webinar Series

Background Subtraction for Manual Spectra Use the Ctrl Key to average multiple range selections then Extract Spectrum. Change manual spectrum background to Current background spectrum. 46 MassHunter Webinar Series

Background Subtraction for Manual Spectra Extract Spectrum Description indicates subtraction occurred. 47 MassHunter Webinar Series

Extract Peak Spectrum Extracts an averaged spectrum from a chromatographic peak automatically. Must integrate to define chromatographic peaks. Integrate the chromatogram to locate chromatographic peaks. Four step process. 48 MassHunter Webinar Series

Extract Peak Spectrum Enable Peak Select tool. Double-click on peak. Set up Peak Spectra Extraction 49 MassHunter Webinar Series

Extract Peak Spectra Automatically Spectra Results from each Integrated Peak Select Integrate and Extract Peak Spectra from the menu. 50 MassHunter Webinar Series

Considerations for Accurate Mass Data Using Extract Peak Parameters Saturation Change to 5% Change to 20% Never return an empty spectrum finds the spectrum with the least saturation. 51 MassHunter Webinar Series

Using Extract Peak Parameters Isotope Model Chose Isotope model that Corresponds to workflow. Common organic molecules Peptides Unbiased Glycans For Small Molecule Applications: Set to 2 For High Molecular Weight Apps: Uncheck or Max 10 52 MassHunter Webinar Series

Extract Spectra Peak Filters 53 MassHunter Webinar Series

Walk Chromatogram Walk Chromatogram Use left and right arrows on keyboard to step through single spectrum. Walk Chromatogram Can be useful for coeluting peaks. 54 MassHunter Webinar Series

Add Preview Spectrum to Results Right-click Select Copy to Spectra 55 MassHunter Webinar Series

MS Spectrum Peak List One Right-click spectrum > MS Spectrum Peak List One. Tool is also available. 56 MassHunter Webinar Series

MS Spectrum Peak List Two New CTRL click on 2 nd spectrum > MS Spectrum Peak List Two Tool is also available. 57 MassHunter Webinar Series

Saving the Results Results are saved from File > Save Results or from icon. Only one results file can be saved per data file. The current method and results are saved in the current data folder > Results > Qual > Version 3 folder Results can be loaded in the Open Data File dialog under Options. 58 MassHunter Webinar Series

Let s take a moment for a demo and questions on Working with Mass Spectra Up Next: Searching and Annotations 59 MassHunter Webinar Series

Library/DB Searching and Formula Generation Qualitative Navigator offers the ability to perform spectral library or database searching and formula generation. Intended to be used for quick, manual scouting of data files. For automated compound searching, compound discovery, and compound reports, use Qualitative Analysis Workflows. Note: No Compounds are generated and no Compound Reports are possible in Navigator. 60 MassHunter Webinar Series

EI Library Search GCMS Default-GCMS-SQ.M method has good starting points for EI library searches. Parameters can be adjusted in Identify Spectra section of Method Editor. Select the spectra you want to identify and click Identify Selected Spectra. or Right click in spectrum window and select Identify Spectra. Note : Details on these settings will be covered in the Qualitative Analysis Workflows Webinar. 61 MassHunter Webinar Series

EI Library Search GCMS Spectrum Identification Results are shown and the spectrum is labeled with the structure if a library hit is found. 62 MassHunter Webinar Series

Difference Results GCMS Navigator also offers Spectral Difference Results. By default the window is tabbed with the MS Spectrum Results window. Useful for comparing mass spectrum with library or database spectrum. 63 MassHunter Webinar Series

Formula Generation When working with high resolution data, formulas can be generated from spectrum peaks, or they can be searched against a library or database. For simply formula generation, use the range select tool to highlight the ion of interest, along with its isotopes. Right click and choose Generate Formulas from Spectrum Peaks. 64 MassHunter Webinar Series

Library/DB Searching Or, for a library or database search, again use the range select tool to highlight the ion of interest, along with its isotopes. Right click and choose Search Library/DB for Spectra Default-LCMS.M method has good starting points for high resolution data formula generation or Library/DB searching. 65 MassHunter Webinar Series

Annotation of Chromatograms and Spectra 66 MassHunter Webinar Series

Place Graphic into Annotation Mode Click Annotation Mouse Tool Annotation Toolbar and Annotation cursor appear Annotation Toolbar Annotation Mouse Tool Annotation Cursor 67 MassHunter Webinar Series

Add a Text Annotation Step 3 Enter Text and set other properties as desired Step 1 Position cursor where the annotation should be placed Step 2 Right click to bring up the annotation menu then select Add Text Annotation Step 4 Click OK 68 MassHunter Webinar Series

Text and Pointer Can Be Repositioned Drag and drop to move text or pointer 69 MassHunter Webinar Series

Image Annotation Same steps as adding Text JPEG and MOL (molecular structure) files are supported Image may be scaled and pivoted 70 MassHunter Webinar Series

Anchored vs. Floating Annotation Fixed without Pointer Fixed with Pointer Floating Y Scale Zoomed 71 MassHunter Webinar Series

Delta Mass Caliper Used to calculate and display mass differences between two ions. Drag and drop 72 MassHunter Webinar Series

Delta Mass Caliper - Mass Caliper Mode Click Delta Mass Caliper Mouse icon Caliber Toolbar and Caliper cursor appear Add or Edit Calipers Calipers can only be placed where there is a signal and snap to closest ion Caliper Toolbar Delta Mass Caliper Drag and drop to span masses Caliper Cursors 73 MassHunter Webinar Series

Delta Mass Caliper Profile Options Only used on profile data Profile Peak to Peak will snap Caliper to profile peak apex Profile Point to Point will allow the user to position the Caliper to any point 74 MassHunter Webinar Series

Let s take another moment for questions on Searching and Annotations Up Next: Training Resources 75 MassHunter Webinar Series

Training Resources Available Training Resources Convenient Training In our classrooms, at your site or online. From a team of industry experts that deliver a high quality learning experience. Classroom Training Introductory level to in-depth, hands-on for laboratory instrumentation and software. Customized On-Site Training Effective learning environment designed to achieve operational excellence and employ development without the need to travel. Online Offerings from foundation level to expert delivered at your own pace. 76 MassHunter Webinar Series

Agilent University Access From Home Page Upgraded customer experience Search and find courses that meet your interests and needs in the format they require. Introduce new elearning capabilities Recorded and video-based learning Virtual online classes Expanded portfolio Foundational subjects Intermediate subjects Advanced subjects Workflow and applications Helping customers Educate your employees on Agilent instruments and software. From new hires to the most seasoned scientists. 77 MassHunter Webinar Series

Agilent Community Agilent Community community.agilent.com Get answers. Share insights. Build connections. Collaborate - Ask and answer questions. Connect - Interact with other Agilent users. Discover - Find relevant discussions, documents, and videos. Share - Contribute your insights. 78 MassHunter Webinar Series