Lighting Controls and Connectivity DALI interface. DALI Interface RS232 PS/S PC interface module for DALI systems

Similar documents
connecdim Gateway G1 Ethernet TCP/IP to DALI

DALI SCI RS232. DALI SCI RS232, Datasheet. DALI RS232 Interface. Communication interface between a PC (or PLC) and modules in a DALI lighting system

DALI SCI RS232, Datasheet

Lighting Controls and Connectivity scenecom. scenecom L, XL, XL EM and XL EM Bac scenecom Controller

basicdim Wireless Wireless module for basicdim

Lighting Controls and Connectivity basicdim. basicdim Wireless Passive Module Wireless module for basicdim

LED Driver Compact fixed output

LED Driver Compact fixed output

LED Driver Compact fixed output

LED Driver Compact fixed output

LED Driver Compact fixed output

LED Driver Compact fixed output

LED Driver Compact fixed output

DALI 4Net. Manual. Central Control Device. Central Control Device for 4 DALI-lines. Version 0.3

LED Driver Compact fixed output

LED Driver Compact fixed output

LED Driver Compact fixed output

LED Driver Linear / area dimming

LED Driver Compact fixed output

LED Driver Compact fixed output

net4more IP connected lighting system net4more Driver net4more driver DC 30W mA un:c LED Driver for net4more systems

LED Driver Constant voltage. Driver LC 35W 24V SC SNC essence series

LED Driver Compact fixed output

LED Driver Constant voltage. Driver LC 200W 24V SC SNC essence series

Lighting Controls and Connectivity DALI sensors. MSensor G3 SFI 30 PIR 10DPI WH Multi-sensor

LED Driver Compact fixed output

PHASED OUT. LED control gear Linear / area dimming. Uconverter LCAI 70 W 300 ma I010 one4all V ECO series

LED Driver Linear / area fixed output

LED Driver Linear / area fixed output

LED Driver DC-String

LED Driver DC-String

LED Driver Compact fixed output

LED Driver Linear / area fixed output

LED Driver Linear / area fixed output

LED light engines ready2apply

2 Channel DALI Power Supply and Interface Installation Instructions. This page was intentionally left blank

LED Driver Linear / area fixed output

LED Driver Linear / area fixed output

Lighting Controls and Connectivity DALI sensors. MSensor G3 SFI 30 PIR 5DPI WH/BK Multi-sensor

LED Driver Compact fixed output

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

LED Driver Linear / area fixed output

LED Driver Linear / area dimming

LED Driver Compact dimming

LED Driver Compact fixed output

LED Driver Linear / area fixed output

LED Driver Compact dimming

General Operating, Maintenance and Installation Manual

LED Driver Compact fixed output

LED Driver DC-String

LED Driver Linear / area dimming. Driver LC 50W mA 54V 0-10V lp EXC UNV EXCITE series SELV

LED Driver DC-String

K -B U S R. R S232/ K N X C ontroller. U ser m anual-v er.1 BTCC-02/ KNX/EIB Intelligent Installation Systems

Tunable White LED linear / area. Module QLE G2 PREMIUM QLE PREMIUM

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual

LED converter Linear / area dimming. Uconverter LCAI 70 W 300 ma I010 one4all V ECO

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

LED Driver Constant voltage. Udriver LCU 180W 12/24V IP67 EXC EXCITE outdoor IP67 series

W&T. Universal Fiber Optic Interface Converter W&T. Manual. Universal FO Interface Converter. Model Release 1.0. Subject to error and alteration

LED Driver Linear / area dimming

net4more IP connected lighting system net4more sensors net4more Sensor 5DPI 14 un:c Multi-sensor for net4more system

LED Driver Compact dimming

TRP-C08. USB to RS232/422/485 Isolated Converter. User s Manual. Printed Sep.2014 Rev 1.4

LED Driver Linear / area fixed output

LED Driver Linear / area dimming

LED Driver Linear / area fixed output

LED Driver Linear / area dimming

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

Hardware Manual RM CANview

PXR11 PXR12. System controllers DESIGO PX

LED Driver Constant voltage. Udriver LCU 100/96W 12/24V IP67 EXC EXCITE outdoor IP67 series

PHASED OUT. LED light engines ready2apply. Engine SLA ready2apply phase-cut SNC Engine SLA ESSENCE

ISE 021 S-DIAS Interface Module RS232 / RS485

RS485 MODBUS Module 6RO

CMU 100 RS485 to Ethernet Converter User Manual CMU 100 / CMU 100 / 1.M.9 CMU 100 / 1.L.9 CMU 100 / CMU 100 / 7.M.9 CMU 100 / 7.L.

CONTROL MICROSYSTEMS SDI-12 Interface Module. Hardware Manual

ECS ecompass Series. ECS ecompass Series. Strap down Electronic Compass. General Description. Features. Making Sense out of Motion

LED light engines ready2apply. Module SLA DC G2 50mm SNC Modules SLA ESSENCE

LED Driver Linear / area dimming

USB to RS232 Converter USB-013 (Rev3) User s Manual Ver. 1.2 HuMANDATA LTD.

is then retained absolutely without interruption.

Installation and User Guide

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

IPC194. ipconv Protocol Converter

RTS ISDN 2002 System. Operator Manual Software Description

Control unit for lux control, MDRC Type: SL/S 50.1, GH Q R0001

epowerswitch-8 Power Management Master Slave User's Guide

LED Driver Compact dimming

IMPORTANT SAFETY INSTRUCTIONS

PK2200 Series. Features. C-Programmable Controller. Specifications Board Size Enclosure Size Operating Temp.


USER MANUAL. Longo programmable controller LPC-2.MC8 Main module. Version 10

RTU560 Connections and Settings DIN Rail RTU 560CIG10

IntesisBox Modbus Server Panasonic

LED Driver Linear / area dimming

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

Emergency lighting units PC COMBO

Operating instructions. Switching amplifier DN0210 DN / / 2015

AB Axis Industries. Use

General Specifications. P2-SCM Serial Communications

Transcription:

Interface RS232 PS/S PC interface module for systems Product description Combines interface module and power supply Integrated power supply with 240 ma for devices or control modules without power supply Interface module for connection of systems with computer or programmable control systems For installation in switching cabinets 5-year guarantee Technical data Rated supply voltage 110 240 V Permitted input voltage 110 260 V Mains frequency 50 / 60 Hz Power 1 6 W Standby power 1 W Max. output current, 240 ma Output voltage 16 V ±5 % Operating temperature 0... +50 C Storage temperature -20... +60 C Max. casing temperature tc 80 C Permitted relative humidity 10 90 %, not condensed Mounting DIN rail mounting, 35 mm Casing material PC, flame retardant, halogen-free Type of protection IP20 91 35 35 59 È Standards, page 3 Wiring diagrams and installation examples, page 3 Ordering data Type Article number Packaging, carton Weight per pc. Interface RS232 PS/S 28001847 100 pc(s). 0.09 kg Specific technical data Type Input RS232 output Interface RS232 PS/S 1 1 www.tridonic.com 1

ACCES- SORIES Interface RS232 cable Product description Connection cable 1 m for connection of computer with Interface RS232 PS/S RJ45 to D-sub unshielded Ordering data Type Article number Length Packaging Weight per pcs. Interface RS232 cable 28000087 1 m 1 pc(s). 0.06 kg www.tridonic.com 2

1. Standards EN 55022 EN 60950-1 EN 61000-3-2 EN 61000-3-3 EN 61000-6-2 EN 61547 1.1 standard Interface RS232 PS/S is designed to control control gear with standard IEC 60929 ( V0) and IEC 62386 ( V1). 1.2 Glow-wire test 2.3 Wiring type and cross section The wiring can be solid wire, stranded wire or stranded wire with end sleeve with a cross-section of 0.75 mm² to 2.5 mm². wire preparation: 0.75 2.5 mm² 6 7.5 mm 2.4 tc control point tc: max. 80 C 44 according to EN 60598-1 with increased temperature of 850 C passed. 25 2. Installation tc signals are not SELV. Therefore the same procedures should be applied as working with mains voltage Individual circuits must not exceed 240 ma The maximum cable length of the signal wires must not exceed 300 m or drop more than 2 V on the signal line voltage The function of the RS232 Interface is tested with all Tridonic products and the functional guarantee applies only with these products 2.1 Connection diagram L, N 2.2 Wiring L N Interface RS232 PS/S PCA EXCEL one4all PCA EXCEL one4all GC GC SC www.tridonic.com 3

3. Functions 3.1 Power-LED green fault-free operation off device or power failure 3.2 Status-LED green, intermittently flickering green, flashing on/off every 0.5 s orange, flashing on/off every 0.5 s off red, intermittently flickering fault-free operation test mode: manually repeated test mode: automatically repeated device or power failure deficiency at /DSI output 3.6 Configuration of the RS232 (RJ45) interface The RS232 (RJ45) interface of the Interface RS232 PS/S allows two types of data transfer: Data transfer mode 1 Data transfer mode 2 (default) Transfer rate: 19,200 baud Transfer rate: 38,400 baud Unidirectional transfer of /DSI commands Bidirectional transfer of /DSI commands Replaced SCI (24033463) Replaced SCI2 (24166096) 3.7 Display configuration of the RS232 (RJ45) interface Release test key during the 3rd orange phase. Current configuration is displayed: 3.3 Test / configuration key The test key can be used to trigger tests as well as certain functions. Triggering a function: Release the test key in the desired orange phase. Function is triggered. 3.4 Orange phase 1 2 3 4 5 2 s 2 s 2 s 2 s 2 s 5 s 10 s 15 s 20 s 25 s Orange phase Function 1 Terminate test mode 2 Test mode: automatically repeated 3 Display configuration of the RS232 (RJ45) interface 4 Switch to data transfer mode 1 ( SCI) 5 Switch to data transfer mode 2 ( SCI2) Data transfer mode Data transfer mode 1 ( SCI) Data transfer mode 2 ( SCI2) 3.8 Switch to data transfer mode 1 ( SCI) Status LED Orange, once 0.5 sec on/off Orange, twice 0.5 sec on/off Release test key during the 4th orange phase. Interface RS232 PS/S switches to data transfer mode 1. 3.9 Switch to data transfer mode 2 ( SCI2) Release test key during the 5th orange phase. Interface RS232 PS/S switches to data transfer mode 2. 3.10 Safety instructions The device may only be used for the application area specified. Relevant health and safety regulations must be observed. 3.5 Test mode Manually repeated: Hold test key down for maximum 2 seconds. The status LED will start to flash green and all luminaires will be switched on. Each further press of the key of less than 2 seconds switches the luminaires on and off in turn. To terminate the test mode, press the test key and release during the 1st orange phase. Test mode is automatically terminated if a command is received. Automatically repeated: Release test key during the 2 nd orange phase. All luminaires are switched on and off every 2.5 seconds. To terminate the test mode, press the test key and release during the 1st orange phase. The voltage supply must be disconnected when the device is being assembled and installed. Only qualified personnel may assemble, install and commission the device. Don t use the Interface RS232 PS/S with other voltage delivering devices (e.g. PS). An other methode to test if a further voltage delivering device is in the signal wire: Interface RS232 PS/S connect without mains supply to the signal wire. If the power LED and the status LED are on despite without mains supply of the Interface RS232 PS/S (typically green) then it is a forbidden supply of the signal wire through an other device. www.tridonic.com 4

3.11 Connection: The RS232 Signals RTS and DTR must be set to the following levels before any communication can take place: RTS = +6... +12 V DTR = -6... -12 V This could be done in software or by hardware wiring. Wiring: RS232 connector (9 pin) RJ45 connector (8 pin) pin 5 pin 3 pin 2 pin 4 pin 7 Ground TxD RxD DTR (for supply purpose only) RTS (for supply purpose only) pin 4 pin 5 pin 6 pin 3 pin 8 Ground TxD RxD DTR (for supply purpose only) RTS (for supply purpose only) 3.12 Maximum length of cable For Data transfer mode 1 (19,200 Baud) 15 m For Data transfer mode 2 (38,400 Baud) 5 m 4. Interface description for data transfer mode 1 ( SCI): 4.1 Serial Interface Configuration: 19200 baud; 8 data bit; no parity; 1 stop bit (19200, 8, n, 1) half duplex 4.2 Transmission Frame: The transmission frame consists of 7 bytes: 8 bit 8 bit 8 bit 8 bit 8 bit 8 bit 8 bit Start/Ctrl ADDR_HI ADDR_MID ADDR_LO DATA_HI DATA_LO Check 4.3 Start/Control: bit 7 bit 6 bit 5 bit 4 bit 3 bit 2 bit 1 bit 0 0 Identify/n Echo DSI/n 0 0 0 0 bit 7: bit 6: bit 5: bit 4: bit 3: bit 2: bit 1: bit 0: High: no data is sent via the bus. Response only on PC (to check connection) when DATA_HI = 00h and DATA_LO = 01h, then enable / when DATA_HI = 00h and DATA_LO = 00h, then disable (default: enable) Low: (DSI) output bus High: immediate reply to PC (not waiting for answer) Low: waiting for answer (10 ms max.) NO after 10 ms High: Data output using DSI format DATA_HI = 0: DATA_LO = 8 bit DSI data DATA_HI > 0: DATA_HI and DATA_LO = 16 bit ext. DSI data Low: Data output using format DATA_HI: HighByte DATA_LO: LowByte 4.4 ADDR_HI... ADDR_LO The adress (ADDR_HI... ADDR_LO) is not used by the RS232 Interface, supported for software compatibility with other products only. Should be set to zero. 4.5 Check XOR-combination of the previous 6 bytes (Start/Control... to... DATA_LO). 4.6 DATA_HI, DATA_LO /DSI data. See Start/Control for a description. www.tridonic.com 5

4.7 RS232 Interface answer to PC: The answer of the RS232 Interface to the PC uses 3 bytes: 8 bit 8 bit 8 bit Start/Ctrl DATA Check 4.8 Start/Control: bit 7 bit 6 bit 5 bit 4 bit 3 bit 2 bit 1 bit 0 Identifier Release Status Identifier SCI ID = 5 Release 0 (firmware releases Feb. 2001) Start/Control in current release Status 00 OK 0x50 01 Data 0x51 10 answer NO 0x52 11 Error check sum: DATA = 1 0x53 bus short circuit: DATA = 2 recive error: DATA = 3 4.9 Data If Identify = 1 or Echo = 1: 0 = disable: 1 = enable else: answer byte 4.10 Check Sum XOR-combination of the previous 2 bytes (Start/Control XOR DATA). 4.11 Attention: The RS232 Interface reply should be checked under all circumstances. This assures the command has been sent (and received) and the RS232 Interface is ready to handle a new command. There is no command buffer in the data transfer mode 1 ( SCI)! www.tridonic.com 6

5. Interface description for data transfer mode 2 ( SCI2): 5.1 Serial Interface Configuration: 38400 baud; 8 data bit; no parity; 1 stop bit (38400, 8, n, 1) half duplex 5.2 Transmission Protocol: To communicate with the RS232 Interface the following simple transmission protocol is used. The forward and backward frame both always consist of 5 bytes. Send this frame to the RS232 Interface: 8 bit 8 bit 8 bit 8 bit 8 bit Control DATA HIGH DATA MID DATA LOW Check Sum 5.3 Control: bit 7 bit 6 bit 5 bit 4 bit 3 bit 2 bit 1 bit 0 ME Identify/ n Echo DSI/n 0 Mode 2 Mode 1 Mode 0 bit 7: bit 6: bit 5: bit 4: bit 3: bit 2..0: Monitor Enable. 1 = enable monitor function. If enabled the RS232 Interface sends all received data back to the PC. High: no data is sent via the bus. Response only on PC (to check connection) when DATA_HI = 00h and DATA_LO = 01h, then enable / when DATA_HI = 00h and DATA_LO = 00h, then disable (default: enable) Low: (DSI) output on the bus High: immediate reply to PC (not waiting for answer) Low: waiting for answer (10 ms max.) NO after 10 ms High: data output in DSI format DATA_MID = 0: DATA_LO = 8 bit DSI data Low: data output in format: DATA_MID: HighByte ( address byte) DATA_LO: LowByte ( command byte) data output in ed format: DATA_HI: ed HighByte DATA_MID: ed MiddleByte DATA_LO: ed LowByte Mode Selection: 0, 1: not used 2: send answer (8 bit data) (DATA_LO) 3: send (16 Bit) (DATA_MID, DATA_LO) 4: send ed (25 bit data) (DATA_HI, DATA_MID, DATA_LO) 5: send DSI (8 bit data if DATA_MID = 0, else 16 bit data (DATA_MID, DATA_LO)) www.tridonic.com 7

5.4 DATA HIGH, DATA LOW If sent to the RS232 Interface: /DSI data. See description of the Control byte If received from the RS232 Interface: see below. The RS232 Interface answer uses 5 bytes to the PC: 8 bit 8 bit 8 bit 8 bit 8 bit Status DATA HIGH DATA MID DATA LOW Check Sum 5.5 Status: bit 7 bit 6 bit 5 bit 4 bit 3 bit 2 bit 1 bit 0 Identifier Release Status Identifier SCI2 ID = 6 Release 0 (firmware release March 2002) Status byte in current release Status 000 OK 0x60 001 answer NO 0x61 010 8 bit data DATA = 8 bit 0x62 011 16 bit data DATA = 16 bit 0x63 100 24 bit data DATA = 24 bit DATA 0x64 101 DSI Data (8 bit if DATA_MID = 0, else 16 bit ext. DSI) 0x65 110 not used 0x66 111 Error Invalid backward frame: DATA = 0x00 0x67 Check sum: DATA = 0x01 -bus short circuit (coming): DATA = 0x02 recive error: DATA = 0x03 -bus short circuit (going): DATA = 0x0C 5.6 Check sum XOR-combination of the previous 4 bytes (Control/Status... to... DATA_LO). 5.7 Attention: The RS232 Interface s reply should be checked under all circumstances. This assures the command has been sent (and received) and the RS232 Interface is ready to handle a new command. There is no command buffer in the data transfer mode 2 (SCI2)! 6. Miscellaneous 6.1 Additional information Additional technical information at www.tridonic.com Technical Data Guarantee conditions at www.tridonic.com Services Life-time declarations are informative and represent no warranty claim. No warranty if device was opened. www.tridonic.com 8