and above (Standard) and above (Option 74) A14 Replacement (Display Module Subassembly w/touch Panel) VM700T

Similar documents
TDSUSBF USB 2.0 Test Fixture Socket Upgrade Kit

VMUPG Option Upgrades VM700T, VM700A VMTB, or VM700A VMTX Video Measurement Set

RSA6000A Series TDS5000B Series DSA8200 Hard Disk Drive Adapter Upgrade Kit XX Instructions

RSA5100B Series Real-Time Signal Analyzers RSA5BUP Option 300 High Performance Real Time Upgrade Instructions

MTS4UP UPG, GBE, CF, EP, QB2, or VS MTS400 Series Upgrade Kits

, , and and above Rackmount Kits Instructions

TLA5Fxxx, TLA62F0x, & TLA7Fxxx PowerFlex Field Upgrade Kit Logic Analyzers Instructions

and above SSD Remote Mounting Kit Instructions

TDS5000B Series SATA Hard Disk Drive Replacement Kit Instructions

5 Series MSO Option SUP5-WIN SSD with Microsoft Windows 10 Upgrade Kit Installation Instructions

Instructions. TLA5Fxxx, TLA6Fxx, & TLA7Fxx PowerFlex Field Upgrade Kits for TLA5000, TLA600, and TLA700 Logic Analyzers

WFM612UP, WFM702UP, and WFM712UP Upgrades WFM6120, WFM7020, and WFM7120 Waveform Monitors Instructions

E2460GS Oscilloscope Upgrade Kit

DPO70000/B and DSA70000/B and Above Power Supply Replacement Kit Instructions

WFM520UP and WVR520UP WFM5200 Waveform Monitor and WVR5200 Waveform Rasterizer Upgrade Kit Instructions

TDS5BUP and TDS5UP Option 1P TDS5000B and TDS5000 Series Integrated Thermal Printer Upgrade and Thermal Printer Replacement Kit

Phase Loss Protection Upgrade. Phase Loss Protection Upgrade. In this bulletin:

Installing the A4504A PMC Bridge Adapter and A4509A Expansion Adapter. HP Part No. A Edition E1197 Printed in U.S.A.

DPO-UP Upgrades for MSO70000/C/DX, DSA70000/B/C/D, DPO70000/B/C/ D/DX/SX, DPO7000/C, MSO5000/B, and DPO5000/B Series Instruments Instructions

AWG701AUP AWG702AUP Options 01, 03, and SSD-0x AWG70000A Series Upgrades Instructions

DSA8200 Digital Serial Analyzer

DSA8300 Digital Serial Analyzer TekScope and Connectivity Software Installation

*E * E E0606

2015 SIMMCONN LABS, LLC. All rights reserved. NewScope-T1 Operation Manual

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E

AWG5000 and AWG7000 Series Windows XP Operating System Restore

WVR720UP, WVR820UP, and WVR830UP Upgrades for the WVR7200, WVR8200, and WVR8300 Waveform Rasterizers Instructions

Series 3700 Screw Terminal Assemblies Installation Instructions

RM3100 Rackmount Kit for the AFG3000 and AFG3000C Series Arbitrary Function Generators

RSA5100A Series Real-Time Signal Analyzers Declassification and Security Instructions

Installation Instructions

Keysight Second Source, Combiner, and Mechanical Switches Upgrade Kit

Replacing the Power Supply

Cutter Option Installation Instructions

Installation Note. Enhanced Memory Upgrade Kit (Option B72) for Agilent ESA-E Series and ESA-L Series Spectrum Analyzers

Installation Note. Removable Hard Disk Drive Upgrade Kit. For All PNA Series RF Network Analyzers. Network Analyzer Model Number

TG700 TV Signal Generator Platform Module Installation

V5420 Host Card Upgrade Kit for R3082D Quick Start Guide

Installing and Removing SDRAM and DRAM

Upgrading and Servicing Guide

Installation Note. Source Attenuators and Bias Tees Upgrade Kit. For E8362B/C PNA Series Microwave Network Analyzers. Network Analyzer Model Number

DSA8300 Digital Serial Analyzer Microsoft Windows 7 Ultimate Operating System Restore Instructions

Installation Note. Configurable Test Set Upgrade Kit. For PNA Series RF Network Analyzers (E8801A, E8802A, and E8803A) Network Analyzer Model Number

Upgrading and Servicing Guide

Pro-Flo System Digital Controller EPROM Upgrade

Service Manual. P GHz Active Probe

Replacing the PanelMate Power Pro 1785 Series, PanelMate epro 7585x-8 and 7685x-8 Series Backlight Assembly

Installing the A4979A PMC Graphics Card. HP Part No. A Edition E1098 Printed in U.S.A.

EMC 10T "CE" Mechanical Upgrade Procedure

Removal and Installation8

AF Upgrade Instructions

Installing and Upgrading Memory and Virtual Private Network Modules

DMM4020, DMM4040, and DMM4050 Connectivity Installation Manual

Intel NUC Kit NUC8i7HNK & NUC8i7HVK User Guide. Intel NUC Kit NUC8i7HNK Intel NUC Kit NUC8i7HVK User Guide

E1135C PDU and Pod Upgrade Procedure

FCA3000, FCA3100, and MCA3000 Series Connectivity Installation Manual

PQA500 Picture Quality Analyzer Declassification and Security Instructions

Instructions to Install Retrofit Kit RVMC 4/5000 Machine (MDB Only)

PowerFlex DC Stand-Alone Regulator (SAR) Field Circuit Board

Intel NUC Kit NUC6CAYS User Guide

Intel NUC Kit NUC7i7BNH Intel NUC Kit NUC7i5BNH Intel NUC Kit NUC7i3BNH

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options

TRC-190 User s Manual

Keysight Second Source, Combiner, and Mechanical Switches Upgrade Kit

AC300/AC400 SERIES DYNAMIC BRAKING and ADDITIONAL FORM C RELAY. INSTALLATION INSTRUCTIONS Document Number:

Installation of the POTS splitter card requires the following steps: Determining the cables you need. Installing the POTS splitter chassis

User Guide for NUC7i3DNHNC. Intel NUC7 Business, a Mini PC with Windows 10 NUC7i3DNHNC. User Guide

INSTRUCTION BULLETIN

Intel NUC Kit NUC7i7BNH, NUC7i5BNH & NUC7i3BNH User Guide. Intel NUC Kit NUC7i7BNH Intel NUC Kit NUC7i5BNH Intel NUC Kit NUC7i3BNH User Guide

Intel NUC Kit DN2820FYKH User Guide. Intel NUC Kit DN2820FYKH User Guide

Instructions. RM2000B Rackmount Kit

Intel NUC Kit D54250WYKH & D34010WYKH User Guide. Intel NUC Kit D54250WYKH Intel NUC Kit D34010WYKH User Guide

Replacing Preamplifier Circuit Boards

User Guide. Intel NUC 8 Business, a Mini PC with Windows 10 NUC8i7HNKQC. Intel NUC 8 Enthusiast, a Mini PC with Windows 10 NUC8i7HVKVA

Intel NUC 7 Home, a Mini PC with Windows 10 NUC7i3BNHXF. Intel NUC 7 Home, a Mini PC with Windows 10 NUC7i5BNHXF

G12/G12x USER S MANUAL

*P * ZZZ

Service Manual. P GHz Differential Probe

GV3000/SE AC Drive ControlNet Network Communication Option Board M/N 2CN3000

Model 2380 Rack-Mount Kit

Upgrading and Servicing Guide

TLA700 Series Tektronix Logic Analyzer Declassification and Security Instructions

Gateway Profile 4 service guide

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

PC9/P9 CPU Card Replacement

Keysight Add Source and Receiver Attenuators Upgrade Kit

Nvidia Quadro FX 5600 graphics card and auxiliary power adapter cable installation

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

4.1 General. 4 Replacement Procedures

An ISO 9001 Company. BOP 1KW-MG FIRMWARE RETROFIT KIT

Installation Note. Agilent PSA Series Spectrum Analyzers Secure Memory Erase, Option 117

Installation Manual PDR GB Disk Drive Upgrade

Peel/Rewind Upgrade Kit

Upgrading and Servicing Guide

ATTENTION: OBSERVE PRECAUTIONS FOR HANDLING ESD-SENSITIVE DEVICES

Upgrading and Servicing Guide

EMC 10/4 "CE" Mechanical Upgrade Procedure

GPIB-232CT-A IBCL EPROM Installation Guide

13 MMC for PC Option Modules

Keysight N9030A Signal Analyzer Option BBA Analog Baseband IQ Inputs Retrofit Kit

Transcription:

Instructions 050-2925-08 and above (Standard) 050-3119-07 and above (Option 74) A14 Replacement (Display Module Subassembly w/touch Panel) VM700T 075-0899-02 Warning The servicing instructions are for use by qualified personnel only. To avoid personal injury, do not perform any servicing unless you are qualified to do so. Refer to all safety summaries prior to performing service. www.tektronix.com 075089902

Copyright Tektronix. All rights reserved. Licensed software products are owned by Tektronix or its subsidiaries or suppliers, and are protected by national copyright laws and international treaty provisions. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supercedes that in all previously published material. Specifications and price change privileges reserved. TEKTRONIX and TEK are registered trademarks of Tektronix, Inc. Contacting Tektronix Tektronix, Inc. 14200 SW Karl Braun Drive P.O. Box 500 Beaverton, OR 97077 USA For product information, sales, service, and technical support: In North America, call 1-800-833-9200. Worldwide, visit www.tektronix.com to find contacts in your area.

General Safety Summary Review the following safety precautions to avoid injury and prevent damage to this product or any products connected to it. To avoid potential hazards, use this product only as specified. Only qualified personnel should perform service procedures. ToAvoidFireor Personal Injury Use Proper Power Cord. Use only the power cord specified for this product and certified for the country of use. Ground the Product. This product is grounded through the grounding conductor of the power cord. To avoid electric shock, the grounding conductor must be connected to earth ground. Before making connections to the input or output terminals of the product, ensure that the product is properly grounded. Observe All Terminal Ratings. To avoid fire or shock hazard, observe all ratings and markings on the product. Consult the product manual for further ratings information before making connections to the product. Avoid Exposed Circuitry. Do not touch exposed connections and components when power is present. VM700T A14 Replacement 1

General Safety Summary 2 VM700T A14 Replacement

Kit Description The Display Module Subassembly/Touch Panel in this kit replaces an earlier Display Module Subassembly/Touch Panel which is no longer available. The replacement assembly requires changing a capacitor on the Front Panel circuit board and several other changes. These changes will ensure instrument specifications can be met for all variations in the characteristics of the replacement Touch Panel. This document supports Tektronix modifications: 76529, TDS-338, 85579, 87971, ECO1087, ECR31202, and ECR31527. Products VM700T B010100 - B052129 Minimum Tool and Equipment List Required tools and equipment Flat-blade screwdriver, Combination wrench or nut driver Socket wrench Pozidriv screwdriver Part number 3/16 or 1/4 inch blade 3/16 inch 1/4 inch socket 1X, 2X Kit Parts List Circuit/figure number Quantity Part number Description A14 1EA 065-0640-xx DISPLAY MODULE; W/TOUCHPANEL, VM700A (STANDARD ONLY) A14 1 EA 065-0682-xx DISPLAY MODULE; W/TOUCHPANEL, VM700A (OPTION 74 ONLY) 1EA 119-7347-xx TOUCHSCREEN CONTROLLER BD REPL KIT A10A1C340 1 EA 283-0645-xx CAP, FXD, MICA DI:790PF, 1%, 300V A5U14 1EA 163-0782-xx IC, MEMORY, COMPATIBLE WITH ELO TOUCH PANEL ASSY VM700T A14 Replacement 3

Kit Description Circuit/figure number Quantity Part number Description 4EA 129-1602-xx SPACER, POST 1EA 174-5413-xx CABLE ASSEMBLY, POWER AND I/O, ELO TOUCH PANEL CONTROLLER 4EA 211-0503-xx SCREW, MACHINE; 6-32 X 0.188, PNH, STL CD PL, POZ 1EA 407-5001-xx BRACKET; CONTROLLER BOARD 1EA 614-1008-xx FRONT PANEL BEZEL ASSY 1EA 063-4091-xx SOFTWARE PKG; CD; FIRMWARE UPGRADE; VM700T 1EA 174-3800-xx CABLE, ASSEMBLY; LAPLINK,PARALLEL PORT TO PC;L 25 FT, DB25,MALE TO DB25, MALE;VM700T 1EA 075-0899 -02 KIT INSTRUCTION; A14 REPLACEMENT, 050-2925-xx AND 050-3119-xx 4 VM700T A14 Replacement

These instructions are for personnel who are familiar with servicing the product. If you need further details for disassembling or reassembling the product, refer to the appropriate product manual. Contact your nearest Tektronix, Inc., Service Center or Tektronix Factory Service for installation assistance. CAUTION. To prevent static discharge damage, service the product only in a static-free environment. Observe standard handling precautions for static-sensitive devices while installing this kit. Always wear a grounded wrist strap, grounded foot strap, and static resistant apparel while installing this kit. NOTE. Instrument upgrades and repairs should only be attempted by qualified service personnel. If you need further assistance, call your local Tektronix representative. CAUTION. Many components in this instrument are susceptible to static-discharge damage. Service the instrument only in a static-free environment while observing standard handling precautions for static-sensitive devices. Always wear grounded wrist and foot straps. Cabinet Removal 1. Remove the top and bottom cabinets from the instrument. Refer to Figure 1. 2. Remove the left and right side cabinets. The side cabinets are removed in the same manner as the top cabinet. 3. Position the instrument as shown in Figure 2. VM700T A14 Replacement 5

Figure 1: Rear view of the VM700A showing top cabinet removal Display Subassembly Removal 1. Remove the four screws that attach the display subassembly to the instrument chassis. Black arrows in Figure 2 show the screw locations. 2. Remove the two screws that fit the EMI bracket on right front side of the frame to have access to the bezel screw. 3. Remove the bezel attaching screw in the location indicated by the larger arrow in Figure 2. (The screw is located behind the front panel.) Do not remove the other three bezel attaching screws at this time. 4. Position the instrument to rest on the bottom. 5. Remove the remaining three bezel attaching screws. The three screws are located near the outer edge of the bezel, midway between each corner. 6 VM700T A14 Replacement

Figure 2: Bottom view showing monitor attaching screws and approximate location of bezel attaching screw 6. Carefully lift off the bezel. As the bezel is separated from the front of the instrument, disconnect the POWER connector from the On/Off circuit board. Note the orientation of the connector. Pin one is indicated with a dot on the connector housing. a. From the circuit side of the STBY/ON switch, remove the two nuts holding the switch assembly to the bezel. See Figure 3. b. Separate the switch and its front plate from the bezel. c. Discard the bezel; you will replace it with the new one provided in the kit. VM700T A14 Replacement 7

Key board bracket Remove two nuts Figure 3: Disconnecting the STBY/ON switch Remove the Card Cage Retainer 7. Remove the Card Cage Retainer from the right side by following these steps: a. Loosen, but do not remove, the two screws on the front of the card cage retainer. See Figure 4. 8 VM700T A14 Replacement

Loosen screws (2). Slide the retainer to the left, and then remove the retainer. Figure 4: Loosening the screws on the right card cage retainer b. Slide the retainer carefully to the left until the screw heads clear the slots, and then remove the retainer to expose the CPU board for removal. c. Disconnect the interconnection cable at J9 on the CPU board. 8. Remove the screws attaching the Key board bracket to the cabinet frame. See Figure 5. 9. Lift out the Front Panel/Key board assembly. VM700T A14 Replacement 9

Figure 5: Removing the retaining screws from the Keypad board 10. Unplug the Touch Panel connector at J933 (on the Front Panel circuit board) and remove the ground wire from beneath the circuit board attaching screw. Refer to Figure 6 for component locations. 10 VM700T A14 Replacement

Ground wire at J933 only installed on instruments with serial numbers from B010100 to B052129. Ground wire Figure 6: Front Panel circuit board assembly (VM700 shown) showing cabling and proper alignment of multi-pin connector (Serial numbers from B010100 to B052129) 11. VM700A - Remove the EMI shield from the front border of the CRT chassis.refertofigure15onpage22forlocation. 12. Remove the display subassembly. As the assembly is removed, unplug the multi-conductor cable from the rear of the module. Modular Subassembly Installation 1. Install the new display subassembly in the chassis and secure it with the four screws but do not tighten them at this time. 2. VM700A - Install the EMI shield removed earlier. VM700T A14 Replacement 11

Front Panel Circuit Board Change 1. Replace C340 with the 790 pf capacitor provided in the kit. C340 Figure 7: Front Panel circuit board showing location of C340 12 VM700T A14 Replacement

Assemble Keypad and Keypad Controller 2. Install the new Power and I/O cable assembly (Tektronix part number 174-7347-xx) onto the back of the Keypad board (Tektronix part number 679-3620-xx) as follows: a. Remove the solder from the hole near fuse F890 that is marked +5V and solder the red wire from the new Power and I/O cable assembly into this hole. See Figure 8. Top Remove solder Bottom Figure 8: Solder Power cable to Keypad board b. Wrap and solder the black wire from the new power cable to TP580 (ground terminal). 3. Install the new Touch Panel Controller board assembly (Tektronix part number 119-6934-xx) to the Keypad board assembly as follows: VM700T A14 Replacement 13

a. Remove four screws from the Keypad board, (see Figure 9) and install the four spacer posts (Tektronix part number 129-1602-xx) into the holes. Torque the spacer posts to 8 in -lbs, using a 1/4 inch socket. Figure 9: Spacer post locations b. Secure the Touch Panel Controller board to the bracket (Tektronix part number 407-5001-xx), using the four screws (Tektronix part number 211-0503-xx). See Figure 10. 14 VM700T A14 Replacement

Figure 10: Installing the Touch Panel Controller board to the bracket CAUTION. Install the cables as instructed. If cables are installed incorrectly, the instrument may be damaged. c. Install the non-keyed end of the new Power and I/O cable assembly (Tektronix part number 174-5413-xx) to the P1 connector on the Touch Panel Controller board. The cable connects to the top row of pins on the connector, with the yellow wire to the outside. See Figure 11. Figure 11: Connecting the RS232 cable to the Touch Panel Controller board VM700T A14 Replacement 15

d. Fasten the cable to the bracket using cable ties as shown in Figure 11. Cut off the end of the cable tie. e. Position the Touch Panel Controller board and bracket assembly on the spacer posts on the Keypad board. See Figure 12. f. Secure the bracket to the spacer posts using the four screws (Tektronix part number 211-0510-xx). Torque to 8 in-lbs. Figure 12: Attaching the Touch Panel Controller assembly to the Keypad board Replace the Boot ROM (A5U14) 4. Install the supplied Boot ROM (A5U14) on the CPU (A5) circuit board as follows: CAUTION. To prevent damage, use an extraction tool to remove the Boot ROM (U14) from the socket. When replacing the supplied Boot ROM (U14), orient the pins using the indexed corner on the Boot BOM to the printed outline on the board. a. Use the board ejector tabs to release the CPU (A5) circuit board. b. Slide the CPU (A5) circuit board out until you can reach the Boot ROM (A5U14). You may need to lift the CPU (A5) circuit board over a board post located below the board. See Figure 13. c. Remove the existing Boot ROM (A5U14) using an extraction tool, and replace it with the supplied Boot ROM (A5U14) on the CPU (A5) 16 VM700T A14 Replacement

circuit board as shown in Figure 13. Note the index on the corner of the Boot ROM (A5U14). Boot ROM (U14) Index CPU (A5) board Lift and slide the CPU board so the post goes over the rubber edge protector Right side Rubber edge protector Figure 13: Replacing the Boot ROM d. Slide the CPU (A5) circuit board into the card cage, and press firmly to seat the interboard connector. Replace the Keypad Board Assembly 5. Replace the Keypad board assembly as follows: a. Attach the touch panel cable to P2 on the Touch panel controller board. The key on the plug should be towards the shield. Make sure to route the cable outside of the standoffs. See Figure 14 on page 18. b. Route the new RS232 cable alongside the flat ribbon cable that connects the Keyboard assembly to J9 on the CPU board. Connect the keyed end of the RS232 cable to J5 on the CPU board. VM700T A14 Replacement 17

Figure 14: Installing the Keypad board assembly (bottom) c. Install the Keypad board assembly on the instrument. Make sure that the Touch Screen cable is free from interference with the chassis. d. Install and tighten the flat-head screws that hold the Keypad board assembly bracket to the instrument front frame. See Figure 5 on page 10. e. Replace the right-side card cage retainer. See Figure 4 on page 9. Replace the CRT Bezel 6. Install the new CRT bezel (included in the kit) as follows: a. Install the STBY/ON switch (that you removed from the old bezel) into the new bezel. b. Position the new CRT bezel near the instrument front panel. c. Connect the 5-connector cable from the instrument to the STBY/ON switch in the new CRT bezel. d. Connect the ground strap ring from the STBY/ON switch to the keyboard bracket. See Figure 3 on page 8. Reinstall and tighten the nut that holds the ground strap ring in place. 18 VM700T A14 Replacement

e. Place the bezel on the front frame. NOTE. Use care in tightening the bezel retaining screws. The threaded bezel inserts can be stripped from the bezel if the screws are over-tightened. f. Reinstall and tighten the four screws that hold the bezel to the front frame. g. Replace the EMI bracket and tighten the two screws. h. Position the monitor so it is flush with the bezel and tighten the four screws. Replace the Card Cage Retainer 7. Replace the card cage retainer by following these steps: a. Connect the interconnection cable at J9 on the CPU board. b. Place the card cage retainer onto the two screws, and slide it to the right. See Figure 4 on page 9. c. Tighten the two screws on the front of the card cage retainer. Replace the Cover Panels 8. Replace the top and bottom panels, and the left and right side panels by guiding them into the chassis grooves, sliding them all the way to the front of the instrument, and installing the screws. Upgrade Firmware NOTE. If your instrument firmware image number is 030930 or later version, you need not upgrade the firmware software. The firmware upgrade is performed using the Firmware Upgrade CD supplied with this kit. The installation program on the floppy disks copies the firmwareupgrade software to your PC. You will upgrade your measurement set using the installed software on your PC hard drive. Complete instructions for performing the firmware upgrade are included in the installation program. VM700T A14 Replacement 19

The minimum PC hardware and operating system requirements for performing the firmware upgrade are listed below: Hardware requirements Operating system requirements 12 MB of free disk space on hard drive MS/DOS (5.0 or later), Windows 98, NT, 2000, or XP 386 microprocessor or better CD or DVD drive LapLink parallel cable (Tektronix part number 174-3800 -xx) Upgrade Your Measurement Set Perform the following procedure to upgrade your measurement set: CAUTION. To avoid loading incorrect firmware into your measurement set, be sure to use the correct firmware-image archive number for the instrument firmware you want to install. The firmware-image Archive number is based on a date using a format of year, month, and day. In most situations, you will want to load the latest version of the firmware into your measurement set. NOTE. Do not perform this upgrade if your firmware Archive number is 030930 or higher. 1. Connect the LapLink cable provided in this kit from the PC parallel port to the VM700T parallel port. 2. Insert the Firmware Upgrade CD provided in this kit into the CD or DVD drive on your PC, and start the PC. The PC will boot to the CD s trimmed version of DOS 5.0. NOTE. You may need to change your PC s boot order to boot from the CD before the HDD (C:). Configuration of the boot sequence will depend on your PC. See your system administrator for assistance. 3. After the PC boots to the DOS prompt, navigate to the drive containing the CD. 4. Change to the VM700T directory on the CD (cd VM700T). 20 VM700T A14 Replacement

5. Run INSTALL.BAT to start the upgrade. The upgrade process will begin almost immediately. Follow the on-screen instructions; the upgrade should need only minimal intervention. The upgrade program will first erase the program memory, and then install the new firmware. This process will take approximately 10 minutes. The PC and the VM700T will both show their progress during the upgrade, and will display a message when the upgrade is complete. 6. If you want to upgrade additional measurement sets, move the LapLink cable to the next VM700T and run INSTALL.BAT. 7. When finished upgrading, remove the CD from the PC and then reboot the PC to return it to normal operation. Verify Operation 1. After installing a new touch panel, perform the following procedures, which are provided in the VM700T Video Measurement Set Service Manual: Adjustment procedure steps pertaining to the touch panel Performance Verification procedure NOTE. Panel calibration values vary greatly depending on the version of touch panel that is installed in your instrument. Sample values shown in the service manual are typical of older touch panels; your results can vary significantly. VM700T A14 Replacement 21

EMI Shield Figure 15: Partial VM700/A exploded view End of document 22 VM700T A14 Replacement