Installation and operating instructions. Control WebCSA. Power Switch WebCSA Add-On. Temperature Sensor WebCSA. Water Level Regulation WebCSA

Similar documents
Bosch Smart Home. Controller Instruction Manual

Operating Instructions VEGAMET 381

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 100. T-Logg 100 E

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

User Manual. Item no.: Otto Graf GmbH Carl-Zeiss-Str. 2-6 Tel.: +49(0) Kunststofferzeugnisse D Teningen Fax: +49(0)

Blu2Light Light Management Installation in Luminaires

SKIVING MACHINE MAINTENANCE & INSTRUCTIONS MANUAL ASSK2. Allswage UK. Roebuck Street, West Bromwich, B70 6RB

Cube LAN Gateway. Operating manual BC-LGW-O-TW

USER MANUAL VIBRATION CONTROL RMA-POWER-BOX 107/230

Z-Wave Ceiling-mount Smoke Detector HZS-200E/HZS-200A

GMH Operating Manual for Digital Quick-Response Thermometer

External level devices for conductive point level switch

Installation manual plugs and connectors with screw connection (16/32 A)

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 120 W -... T-Logg 120 K -...

Z-Wave 4-in-1 Multi Sensor HZS-300E/HZS-300A

MDM 011-Z1 Regen Resistor

HST -M1 Switching element with locking mechanism (Translation of Original Manual)

HST -M2 Switching element with locking mechanism (Translation of Original Manual)

CMC III Universal Sensor

...easy to operate with ProHomeIPC. IP-Kamera OC 800 Quick Start Guide

Operation Manual Locator Wöhler L 200

Installation Guide DEVIlink CC Central Controller

Installation and Maintenance

English. Operating Manual. Conductive point level switch MLR120. Retain for later reference. Companies / brands of GHM

JOVISION. Home Security IP Camera. Quick Start Guide

Digital Quick-Response Thermometer

Controller Smart Box Translation of operating and installation instructions

english S-5EC Potentiometer 5-step Operating Instructions Keep for reference! L-BAL-E265-GB 1608 Index 002

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

Heating Circuit Controller

Product information combined device with binary input / output, single BRE2-EB

FUE 10 FUE-M/S 85A FUE-M/S 86A

Operating instructions for AX5801. TwinSAFE drive option card for the AX5000 servo drive. Version: Date:

HST -TZ1 Guard-locking mechanism (Translation of Original Manual)

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA. GE Critical Power

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content

HST -S1 Switching element (Translation of Original Manual)

CMC III Temperature/Humidity Sensor

Energy Logger. User's Guide. Model EM Washington Street Melrose, MA Phone Toll Free

ZIPATILE. Quick Start Guide v.1.3

VR 80 Remote Control Device

Set-up and programming guide

...easy to operate with ProHomeIPC. IP Camera IC 600 Quick Start Guide

Operating Instruction

Home Automation Gateway HA102

Operating Manual Bedienungsanleitung. Digital Dispense Controller

ZTE MOBILE HOTSPOT QUICK START GUIDE

Megapixel Wireless IP camera with Night Mode & Audio Support V

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions

TETRIS 2500 High Impedance Active Probe. Instruction Manual

Wi-Fi communication module GWD1

Instruction Manual FB-606 FB-606 TF. Infrared Manual Remote Control. LJU Automatisierungstechnik GmbH

DALI Professional Controller-4. Control unit Operating instructions

Instructions for Use. Viega Eco Plus Universal shower WC element. for wall-hung WCs, wall-hung shower WCs, wall-hung WCs with shower WC top

PTB 01 ATEX Example / Beispiel / Exemple. Type Operating Instructions

ITB THROTTLE WITH INTEGRATED STEPPER MOTOR INSTALLATION INSTRUCTION

TVAC25100 TVAC25110 User manual

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

INSPECTION CAMERA MODEL NO: CIC2410 OPERATION & SAFETY INSTRUCTIONS PART NO: GC0116

Operating and Installation Manual. EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions

Sliding shutter control Aluminium shutters

Data logger. Installation and operating instructions. Read carefully before installation, commissioning and operation.

Instruction Manual Standard Multi-Position Stirrers Advanced Multi-Position Stirrers

IPCB42501 / IPCB42551

Operating Instruction for Turbine-wheel Flow Meter. Model: DRS

Ready...Set...Go. Pick a spot and plug it in. Download the Maginon App for Android or ios and install your WiFi Video Camera in a minute.

Operating manual. GTL - Configuration tool. Please keep the manual for future use.

Operating Instructions

Operating Instructions

DuoFern sun sensor Operating and Assembly Manual...15

Wireless Small Actuator MAC-WSA

Operating Instructions

TS 971 door control Integrated radio. TS 971 Automatic control panel for DES / NES limit switches. Approvals and certificates

OPERATING INSTRUCTIONS

Bosch Smart Home Indoor Camera Instruction Manual

Wi-Fi communication module GWD2

Network Video Recorder Quick Start Guide

ES-CAM4A Motorized IP Camera

PMT 201A-RO High Impedance Passive Probe. Instruction Manual

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5A ST (6ES7132-4BD02-0AA0) Preface. Properties 2. Diagnostics 3.

Product Manual for Floodlight Cam

DuoFern Multiple Wall Controller

3G WI-FI HOTSPOT USER MANUAL HHTSPT3GM42.

THE SMART WAY TO ANSWER YOUR DOOR INSTALLATION & OPERATING MANUAL

BLUETOOTH SPEAKER GSB 2000

Assembly and Operating Instructions Door Control

4P M. Wireless LAN Connecting Adapter <BRP069A45> Installation Manual

SMART-e Document Rev1

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5 A ST (6ES7132-4BD01-0AA0) Preface. Properties 1. Diagnostics 2.

Operating manual Solareg II BASIC

GHL Doser. Resource Guide. Step-by-step resource guide for GHL Doser 2.1 and Doser Maxi. Written by V. Altamirano

HST -TS1 Guard-locking mechanism (Translation of Original Manual)

Operating Instructions Differential Pressure Transducer PS27

Push Button Interface UP 220D31

EM4596 Concurrent AC1200 Dual Band Wi-Fi Repeater and Access point

Heating Circuit Controller

Polymer Electric. Operating Instructions. Control Unit SG-RST 153. Version 0.3

MAXIMA+ Series Rotary Level Indicator

Assembly and Operating Instructions. M2 module for BDC-i440 control units

Transcription:

www.inazuma-online.com Installation and operating instructions Some features described in this manual require the software version 5827 of the Control WebCSA. Control WebCSA Power Switch WebCSA Add-On Temperature Sensor WebCSA Water Level Regulation WebCSA

General information Page 1. General information...2 1.1. Introduction...2 1.2. Important safety notes and warnings...2 1.3. Warning label...2 1.4. Manufacturer...2 1.5. WEEE-registration...2 1.6. EC declaration of conformity...3 1.7. Alteration and modification...3 1.8. Spare parts...3 1.9. Transport...3 1.10. Description and function of the product...3 1.11. Warranty...3 2. Control WebCSA...4 2.1. Connections...4 2.2. Before commissioning...4 2.3. Mounting the retaining clips for wall mounting...4 2.4. Functioning of the control...5 2.5. Depiction of the float switches...5 2.6. Configuration of the control without App or WLAN...6 3. WebCSA App & Inazuma WebCSA Cloud...7 3.1 Registration and installation...7 3.2. Main screen...9 3.3. Settings...9 3.3.1. Installation type...9 3.3.2. Rinsing parameters...9 3.3.3. Power Switch...10 3.3.4. Water Level Regulation...10 3.3.5. Service menu...10 3.3.6. Operation mode...10 4. Power Switch WebCSA Add-On (optional)...10 5. Water Level Regulation (optional)...11 5.1. Functioning...11 5.2. Connection to the control...11 5.3. Installation Sensor & Magnetic valve...11 5.4. Winter operation...11 6. Temperature Sensor (optional)...12 6.1. Connection to the control...12 7. Licensing (online activation)...12 8. Updating the Control WebCSA...13 8.1 Automatic Update...13 8.2. Manual Update...13 9. Mounting the two float switches...14 9.1. Mounting float switch 1...14 9.2. Mounting float switch 2 (gravity)...14 9.3. Mounting float switch 2 (pumped)...14 1. General information 1.1. Introduction Congratulations on your new acquisition an Inazuma control WebCSA, the Power Switch WebCSA Add-On, the Temperature Sensor WebCSA and/or the Water Level Regulation WebCSA. To avoid restrictions on function and warranty it is important to read this manual carefully. To make sure your filter works as supposed to, we ask you to follow the manual, the user- guide and additional notes that are provided with this product, closely. In the event of emerging questions not addressed in this manual we ask you to get in contact with your (local) dealer. Always disconnect the power plug before connecting / disconnecting components or opening the control unit 1.2. Important safety notes and warnings Please store this manual at an accessible location to be able to address emerging questions about installation, function and debugging. It is recommended to keep a copy of this manual close to the filter so e.g. technicians are able to get quick access to all informations needed. 1.3. Warning Label The sign next to this text points out important warnings or significant Informations. 1.4. Manufacturer Inazuma Johannes Kurzweil GmbH Eisackstraße 16 DE 86165 Augsburg Tel.: +49 (0)821-72 919 72 Fax.: +49 (0)821-72 919 73 Email: info@inazuma-online.com Web: www.inazuma-online.com 1.5. WEEE-registration The WEEE-registration ensures that the producers are assuming liability for their electrical and electronic equipment, especially the responsibility for recycling and disposing of these according to the ElektroG. The Federal Environment Agency of Germany (Umweltbundesamt) confirms the registration of this product under the following number: WEEE-Reg.-Nr. DE 19429673

www.inazuma-online.com 1.6. EC-Declaration of Conformity Manufacturer: Inazuma Johannes Kurzweil GmbH Eisackstraße 16 DE 86165 Augsburg Tel.: +49 (0)821-72 919 72 Fax.: +49 (0)821-72 919 73 Directives in use: Machinery Directive: 2006/42/EG, Low Voltage Directive: 2006/95/EG, General Product Safety Directive: 2001/95/EG Swiss implementations SR 819.14, SR 930.11 and SR 734.26. Furthermore, the EN ISO 12100:2010 applies. The manufacturer declares hereby the conformity of the product with the safety requirements mentioned above. 1.7. Alteration and modification We point out that every alteration or modification without written approval by Inazuma or one of its authorized suppliers will cause the immediate annulment of the CE conformity assessment. Inazuma will not assume liability for damages on persons or property emerged by unauthorized alterations or modifications. 1.8. Spare parts Only spare parts provided by Inazuma or one of its authorized suppliers are approved for installation. In the event of usage of non-authorized parts the warranty will expire and Inazuma will not assume liability for damages. Only use special tooling. 1.9. Transport The control, temperature sensor and / or water level regulation should always be transported or shipped only in the original packaging. 1.10. Description and function Control WebCSA Microprocessor control with WLAN and App Connection for easy control of your filter system via mobile phone or tablet from anywhere (Internet access required). Power Switch WebCSA The Inazuma Power Switch WebCSA is used to control various consumers, such as pond pumps or lighting elements, and to switch them on and off via a timer. Temperature Sensor WebCSA Sensor for displaying the water temperature in the WebCSA app. Water Level Regulation WebCSA The Inazuma pond level regulation is used to automatically compensate for water losses on koi, swimming, garden and ornamental ponds. 1.11. Warranty The warranty of the WebCSA control, of the Power Switch WebCSA Add-On, the Temperature Sensor WebCSA and / or the water level regulation WebCSA is limited to the respective device. The liability does not cover defects caused by accidents or improper installation or usage, as well as possible consequential damages. The liability only covers the replacement of the defect drum itself. Any modification of the devices or its cases leads to the loss of the warranty. The modification of the connection cables, e.g. the removal or replacement of the connection plugs also leads to the loss of the warranty. This warranty is not transferable. CAUTION The manufacturer will not assume responsibility for any damages emerged by misuse of the product or parts of it or by non-observance of rules, guides and manuals provided in this document and additional documents (including stickers and warning signs) provided with the product. The devices can only be operated, if your house wiring owns a ground fault circuit interrupter (GFCI) / residualcurrent device (RCD) (30 ma for humid environment) and the power supply is connected to said system. It is also recommended to use an overvoltage protection class D or 3 (depending on your local guidelines). 3

2. Control WebCSA 2.1. Connections 1. Mains Plug 2. Gear motor 3. High pressure pump 4. UVC 5. UVC 6. Power-Switch P1 7. Power-Switch P2 (optional function) 8. Power-Switch P3 (optional function) 9. Power-Switch P4 (optional function) 10. Cover switch 11. Magnetic valve for rinsing flush 12. Float switch 2 (2 floaters) 13. Float switch 1 (1 floater) 10 11 12 13 14 16 15 3 4 5 2 1 14. Temperature sensor (optional) 15. Magnetic valve for water level regulator (optional) 16. Water level sensor (optional) 9 8 7 6 Always disconnect the power plug before connecting / disconnecting components or opening the control unit 2.2. Before commissioning Before commissioning the filter, the system must be filled with water and the cover must be closed. Control is splash proof (IP65) Protect from direct solar radiation To wall mount the drum filter control, please use the provided wall mounting panel. Do not drill any holes into the case, otherwise the warranty will be lost. 2.3. Mounting the retaining clips for wall mounting The delivery includes 4 retaining clips. Please mount these on the rear side of the housing as shown below. The control unit must be configured before commissioning. The configuration can be done by app or by float switch. On the following pages the necessary steps are described. Insert retaining clip as shown. Turn the retaining clip to the middle of the housing. This fixes the clip. The drum filter control system should only be opened by qualified personnel There is a danger of electric shock and risk of injury, as the circuit board is live. Always disconnect the power plug before connecting / disconnecting components or opening the control unit Mounted retaining clips. 4

www.inazuma-online.com 2.4. Functioning of the control The rinsing process will start automatically depending on the pollution level of the drum. When the drum is soiled to a certain level, the float switch SS2 activates the rinsing process. 2.5. Depiction of the float switches SS1 = single float switch The drum filter control is equipped with a malfunction detector. When a malfunction is detected, the control reports a malfunction by sending out a beeping sound: Beep sound for 1 second every 5 seconds. ATTENTION You have to pay attention to the water level if you have a pond without an automatic water refill system. If the water sinks below the level of the bottom float switch, the filter will turn off automatically, or else a continuous irrigation would occur. Inazuma offers an automatic pond level regulation (item no. IK5001) SS2 = double float switch SS2t = top floater of the double float switch SS2b = bottom floater of the double float switch 5

ATTENTION: If you configure the control unit with the app, you can proceed directly with step 3.1. 5. Configuration of filter and installation type move the floater SS1 within 30 seconds 2.6. Configuration of the control without App or WLAN For the configuration of the control without app, we recommend the following procedure: 1. Connect both float switches to the control unit 2. Position the floaters as shown 3. Configuration: Make sure the floats are in the position shown above before power is applied. After power is turned on, the software boots up (may take 2 to 3 minutes). When the software has successfully started, you will hear: if there is no configuration assigned: 2 beep sounds if there is a configuration assigned: 4 beep sounds followed by a single long beep sound. After about one minute, the control unit is in configuration mode. While the controller is in this mode waiting for configuration mode to be activated you will hear 2 beep tones every 5 seconds. The software remains in this loop until the configuration mode is activated. 4. Activating the configuration mode SS1-floater = down & at the same time SS2b-floater = down for 5 seconds Control ends the start of the configuration mode with 3 short beep, beep, beep. Then, depending on the filter type and the type of installation, the mode is set with the float switch SS1. 1 x up & down = drum filter - gravity setup (with warning sounds) 2 x up & down = drum filter - gravity setup (without warning sounds) 3 x up & down = drum filter - pumped setup (with warning sounds) 4 x up & down = drum filter - pumped setup (without warning sounds) 5 x up & down = endless belt filter - gravity setup (with warning sounds) 6 x up & down = endless belt filter - gravity setup (without warning sounds) 7 x up & down = endless belt filter - pumped setup (with warning sounds) 8 x up & down = endless belt filter - pumped setup (without warning sounds) Each movement of the float is confirmed with a beep tone. After the 30 seconds the selected configuration is active, the control confirms the configuration with a short beep and a long beep. Disconnect the power supply to the controller and install the float switches in the filter (see chapter 9). Subsequently, the controller can be put into operation. If you are unsure about the configuration, restart it beginning with step 1. Tip: Quick configuration of the control for the setup type drum filter - gravity setup (with warning sounds) Disconnect the power supply to the control. Position the floaters as shown on the right. Connect the control to the power supply. Do not move the floaters for 2 to 3 minutes During the waiting time, you will hear several beeping sounds with different duration. When the configuration is complete, you will hear a short beep every 5 seconds. Disconnect the power supply to the controller and install the float switches in the filter (see chapter 9). Subsequently, the controller can be put into operation. 6

www.inazuma-online.com 3. WebCSA app & Inazuma WebCSA cloud 3.1. Registration and installation In order to be able to use the WebCSA control system with all its functions, we recommend to you to first register online on the Inazuma WebCSA Cloud: http://webcsa.inazuma-online.com We recommend that you first make the initial setup of the control unit before installing the unit on the filter or before installing the float switches in the filter. For the initial setup you need a mobile phone or tablet with Android operating system Your WLAN access data (WLAN name (SSID) and password) the control WebCSA a socket to connect the WebCSA control 1. Download and update The current version of the Android app can be found on our homepage www.inazuma-online.com and in the Google Play Store. Save the app, start it from your phone / tablet and follow the installation instructions. If the direct download does not work, tap on the name of the app a little longer this opens a message box, there you can then download the app using the function download link. Installing the app depending on the security settings in your mobile phone or tablet, a message box Security can be opened during the installation, please allow the installation from unknown sources. 2. Connect float switches 1 + 2 to the control, set float switch in reset mode (see left picture) 3. Connect the control to the mains 4. Open the Inazuma WebCSA app on your mobile or tablet 5. The starting process of the control unit takes about 1 to 2 minutes. The control acknowledges a successful start with a long beep. Continue with step 6 of the installation. 7

6. Start initial setup Click on the button Start initial setup. Further steps will be displayed in the app. 9. Successful WLAN connection When the control is successfully connected to your home WLAN, it will be displayed in the app. The process can take up to 2 minutes. After about 1 to 2 minutes, the phone and the controller should have established a connection to each other (Step 7). No connection after the waiting time? Depending on the settings of the mobile phone and operating system version, it may be that the app does not get the necessary permissions to automatically open a Wi-Fi hotspot. In this case, please do the following: Manually set up a hotspot on your phone: Menu> Settings> More> Tethering & Mobile Hotspot> Mobile WLAN Hotspot Configure the hotspot as follows: Hotspot Name: Inazuma Password: Inazuma2018 Activate the configured hotspot. Now, in the status bar of your mobile phone the hotspot symbol should be displayed. Close the Inazuma WebCSA app on your phone. Disconnect the control from the mains and wait about one minute. Now carry out the configuration starting with step 2. 7. Successful connection If cell phone and control have established a mutual in the network, please select your filter and installation type. 8. Setting up the WLAN connection Click on the magnifying glass / search button to select your home network from the WLAN networks found. Alternatively, you can also enter the WLAN name and password directly. Click on Save network settings. The rest of the process can take up to 5 minutes. Please note the information on WLAN connection quality on the bottom right of this page 10. Completing the setup After successfully setting up the WLAN connection, the app displays the network address of the Inazuma control WebCSA. Write down the IP-address shown You may need to turn on WLAN on your phone / tablet manually. Now click on Login or Register. Shortly afterwards, the main view of the app should open. 11. Login to the cloud In order to be able to see the filter status outside of your home network, it is necessary to connect the app to the Inazuma cloud. Activate the setting Connect to the Inazuma WebCSA Cloud and enter your e-mail address and password you registered with in 3.1. After clicking on the Login or Register button, the app connects to the Inazuma cloud. 12. Assembly of the control and the float switches If you have successfully connected the app to the control, please install the float switches in the filter as described in chapter 9. The wireless connection quality depends on the location of the controller and the distance to yours WLAN router. If your WLAN can not be found, it is usually due to the signal strength of the router. In the specialized trade / electronics market numerous affordable WLAN repeaters are available. 8

www.inazuma-online.com 3.2. Main screen [P1] [P2] [P4] [P4] Displays the status of each Power Switch output. A green background means that an output is active. By short tapping, the outputs can be switched on and off. A long pressing of the buttons opens up the Power Switch settings menu. (?) Help Opens up the help page for the currently opened page (i) Information button Is displayed if e.g. new updates for the control are available. WLAN symbol Displays the WLAN connection quality between control and your router. Please also note the section WLAN connection quality in the operating instructions of the control. Gear icon Opens the settings menu of the filter control. Filter cover Indicates the state of the filter cover (closed / open). When the filter cover is open, rinsing processes won t start, current rinses stop and the UV-C lamp switches off. Water level Indicates whether the water level in the filter is correct. UV-C lamp Displays the status of the UV-C output. A yellow symbol means, that the output active. By tapping, the output can be switched on and off manually. The second line shows the number of operating hours. You can reset the counter in the Settings menu. Mode The currently set mode is displayed. By tapping you can switch between the modes summer autumn winter. Please see the section Operating mode in the operating instructions of the control. Water temperature (optional) The optional temperature sensor (item no. IK5003) displays the water temperature. Water level regulation (optional) Indicates the start of the last refill. By tapping, the refill can be activated manually. Rinses Displays the total number of rinses. Tapping the (X) resets the counter. Drain flushes Displays the total number of drain flushes. Tapping the (X) resets the counter. Status Displays the current operating status of the filter. Hand rinse Starts a rinsing process including drain flushing. 3.3. Settings (gear icon) 3.3.1. Installation type Select your filter and installation type here. Gravity = the filter is at pond level (filter shaft) 3.3.2. Rinsing parameters In this menu, you can set various rinsing parameters, e.g. the filter rinsing time and the number of drain flushes. Pumped = the filter is above the pond level 9

3.3.3. Power Switch [P1] (optional also [P2] [P3] [P4]) Select the desired channel (P1 to P4) at the top of the bar. In case of faults off = the channel is switched off in the event of a fault (= dry-running protection) on = the channel is switched on in the event of a fault Maintain plan = the set switching times are executed independently of the fault Name = Here you can assign a unique name to the channel, e.g. Pond illumination Each switch-on or switch-off function has its own switching point. You can create a maximum of 24 switching points per channel. 3.3.5. Service menu (i) 3.4.6. Operating mode Menu for displaying various sensor states and software versions. Reset UVC Here you can reset the UVC hour counter to 0. Start software update starts a manual software update of the control. The control unit must be connected to the internet. To update the control unit using the app see chapter 8. Here you can choose between three different modes. To be able to switch on the channels manually in the app, it is necessary to create at least one switching point for each Power Switch output. Otherwise the channel (for example PS1) can be switched off, but it will switch back on again after about 10 seconds. 4. Power Switch WebCSA Add-On (optional) The Power Switch WebCSA is an extends the number of individually assignable outputs from 1 to 4. It is the ideal control extension for your pond pumps, waterfall pumps and garden lighting, or similar. All functions of the Power Switch can be programmed and operated via the Inazuma WebCSA App. 3.3.4. Water Level Regulation (optional) Level delay time If the water sensor is in the water again, water is added for the set delay time. After this time, the solenoid valve switches off. Level max. running time Limits the maximum duration of the level regulation, regardless of whether the desired pond level has already been reached. P4 P3 P2 outputs activation by code for the Power Switch WebCSA extension P1 output already activated in the delivery state of the control 10

www.inazuma-online.com 5. Water level regulation WebCSA (optional) The Inazuma water level control is an electric, fully automatic control unit for the compensation of water losses on koi-, swimming-, garden- and ornamental ponds. It consists of Magnetic valve 230 V / 50 Hz with 5 m connection cable Water sensor incl. 10 m connection cable Activation by code (internet access required for activation). 5.1. Functioning Water level OK Water level sensor is in water > magnetic valve closed > no refilling Water level sinks As soon as the water level sensor is outside the water for more than 20 seconds (wave suppression), the solenoid valve opens. Water is refilled. Overfilling time function The level control is equipped with a so-called overfill time function to prevent constant on and off switching of the solenoid valve. This means that the water level regulator keeps refilling after reaching the desired water level for the duration that you can adjust in the overfill time option in the app. Only then does the solenoid valve close. This prevents the regulation from switching on too frequently over the course of the day if the water level drops too low. Therefore, the sensor should be installed about two centimetres below the desired maximum pond water level. Safety function The refill time is limited to a maximum of 60 minutes. 5.2. Connection to the control Always disconnect the power plug before connecting / disconnecting components or opening the control unit Magnetic valve Water level sensor 5.3. Installation sensor & magnetic valve Water level sensor Install the water level sensor in the pond at the desired height so that the two contacts are horizontally approx. 2 cm below the water surface or the maximum pond water level. The sensor can be attached by a screw through the existing hole on the sensor. Magnetic valve The water supply of the solenoid valve can take place for example by the domestic water connection. All Inazuma filters have a hole to attach the magnetic valve. Valve inlet (left picture) The flow direction of the water is marked on the underside of the solenoid valve by an arrow. When using 3/4 double nipples for connection (not included), always use plastic nipples. After this time, the solenoid valve switches off. The app displays overfill protection. At the same time, an internal countdown is triggered which returns the level regulation to the automatic operating mode after 12 hours. Alternatively, the level regulation can be reactivated manually in the app. Mains plug: Only connect the mains plug after making sure that all other steps have been carried out correctly. Your pond level regulation WebCSA is now operational. 5.4. Winter operation At temperatures below 0 C, it must be ensured that the water pipe or the magnetic valve can not freeze or be damaged. 11

6. Temperature sensor WebCSA (optional) The temperature sensor is a digital sensor for connection to the WebCSA control. It consists of A stainless steel sensor with cable length 5 meters; high quality silicone cable with plug 6.1. Connection to the control Always disconnect the power plug before connecting / disconnecting components or opening the control unit 7. Licensing (online activation) The functions of the water level regulation, the power switch and the temperature sensor must be activated by online activation. Make sure that the app has a connection to the Inazuma WebCSA Cloud (setting in the login screen of the app) You need a working internet connection on your mobile phone / tablet Under the respective function you will find a button enter license. After successful installation, the water temperature will be displayed in the WebCSA app Enter the supplied activation code in the text field and confirm your entry with OK. If the entry was successful, the function is activated immediately. 12

www.inazuma-online.com 8. Updating the Control WebCSA 8.1. Automatic Update For optimum operation of the WebCSA control we recommend activating the automatic update function of the control. This requires an internet access / WLAN connection to the control unit. The setting for the automatic update can be activated in the app under the menu item Network. The Update Manager will show you the version available online and the version of the control software stored on the phone. 4. Click on the button Update local version The phone now connects to the server and stores a copy of the control software on the phone. In the next step the software gets transferred to the control. Option 1 The Inazuma WebCSA control is already connected to your WLAN. Make sure that the IP address of the control is entered. Then, click on the Update button. 8.2. Manual Update Control or mobile phone have no internet connection? The software update can also be downloaded manually with a mobile phone and transferred to the control unit. To download the update, the phone requires internet access. The update can then be transferred at a later date with the phone to the control unit, even if your phone or the control unit have no connection to the internet. Procedure 1. Make sure your phone has an internet connection. 2. Open the app. 3. Click on the button Update Manager. Option 2 The control unit is new and has not yet been configured or the control unit has no connection to the Internet / WLAN. Manual setup of a hotspot on your Android phone: Menu> Settings> More> Tethering & Mobile Hotspot> Mobile WLAN Hotspot Configure the hotspot as follows: Hotspot Name: Inazuma Password: Inazuma2018 Then, in the status bar of your mobile phone, the hotspot icon should be displayed Disconnect the control unit from the power supply and wait 30 seconds. Then you can reestablish the power supply. The control software starts. After approx. 1 minute the control appears in the device list on your mobile phone. If you now click on the device list, the IP address of the control will be displayed. Enter this IP address in the corresponding field and click on the Update button. 13

9. Mounting of the two float switches The WebCSA control is supplied with two float switches. The exact position of the float switch must be adjusted individually (slot holes in the mounting). The height depends on the power of the pump. Float switch 1 (1 floater) detects the water level in the prechamber. 9.3. Mounting float switch 2 (pumped) Float switch 2 (2 floats) is responsible for flushing and the dry running protection. 9.1. Mounting float switch 1 (gravity & pumped) Filters with and without biochamber Waste water section in front of the drum Position of the float switch and its mounting In the pump driven setup, the float switch is already installed in the waste water section in front of the drum (left picture). The mounting is completely pre-assembled. Therefore, there is no need to adjust its position. Mounting float switch 1 in the right area of the prechamber under the solenoid valve 9.2. Mounting float switch 2 (gravity) Pump driven setup: Reversal of the function of the float switch Upper float switch: Responsible for the activation of the emergency shutdown and protection of non-stop rinsing. During normal operation of the drum filter it should be always above the water level. If the upper float switch gets pushed upwards by water, the drum filter shuts down and a fault signal occurs. n pump mode, we recommend connecting the pond pump to the Power Switch WebCSA. In this case, your pond pump (connected to the power switch) will then be switched off in the event of a fault and the pond will not be emptied. Biokompakt models: Pure water area outside the drum Filters without biochamber: Mount float switch here. Pure water area outside the drum Bottom float switch: Activates the rinsing-process. At the end of every rinsingcycle the top ring is supposed to float towards the bottom end. Upper float switch: Activates the rinsing-process. At the end of every rinsingcycle the top ring is supposed to float towards the top end. Bottom float switch: Activates the emergency shutdown in the event of nonstop rinsing to prevent a drop of the water level in the pond/pool. The bottom ring is always supposed to be under water. If it falls to the lower stop, the drum filter switches off, because there is too little water in the pond. 14

Edelstahl-Trommelfilter & High-End-Teichzubehör You will be amazed Manufacturer: Inazuma Johannes Kurzweil GmbH Eisackstraße 16 DE 86165 Augsburg Tel. : (+49) 821-72 919 72 Fax : (+49) 821-72 919 73 info@inazuma-online.com www. inazuma- online.com Technical modifications and errors excepted WEEE-Reg.-Nr. DE 46229826 Registration number: DE-BY-1-00078 Manual version 2.08 Some features described in this manual require the software version 5827 of the Control WebCSA.