A1400 GSM Temperature Alarm USER MANUAL A1400-REV FW-A1400v2.94. ERBAŞ TEKNOLOJİ Innovative Solutions. 1

Similar documents
A1000 GSM ALARM DEVICE

USER MANUAL Mobeye CM-Guard CM2000

USER MANUAL. Mobeye WaterGuard-FS. Float sensor CM2300FS. SW version 5.n

GSM SECURITY AND CONTROL SYSTEM ESIM021

USER MANUAL Mobeye Smoke Detector CM2400 Mobeye Heat Detector CM2400H. SW version 3.n

TX-5 LBS ANTI-THEFT ALERT SYSTEM (LBS+GSM+SMS/GPRS) Fast Installation Instruction & User Manual

PLEASE READ BEFORE INSTALL. ECGO-GKP Cellular Telephone Entry

User Manual. GSM Fixed Wireless Phone (Model: GSM-938) Introduction

SS91A-M GSM DOOR PHONE (ACCESS CONTROL SYSTEM)

SS91A-M GSM DOOR PHONE (ACCESS CONTROL SYSTEM)

GSM Communicator GJD710 PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE YOU START THE INSTALLATION

TX-5 LBS ANTI-THEFT ALERT SYSTEM (LBS+GSM+SMS/GPRS) Fast Installation Instruction & User Manual

GPS Child Tracking Device User manual

GPS Vehicle and personal location tracker. User manual

The Packs Infotel. GSM Converter V2. Installation Manual V7

GSM module G10T (v.2.3x) Installation manual. TRIKDIS, JSC Draugystės st. 17, LT Kaunas Lithuania

GSM HOME SECURITY SYSTEM

smartentry Wireless Video Doorphone User Manual

Installation manual Mobeye Call-Key GSM Door Opener

Installation manual Mobeye MS100BK GSM Measure, Control and Alarm module

Installation manual Mobeye MS100B GSM Measure, Control and Alarm module

GPS+Glonass Vehicle location Tracker

ZTE MOBILE HOTSPOT QUICK START GUIDE

UP100-GSM. GSM based intercom and access control. Installation and user manual

Foxi Watch. Mobile watch with GPS for kids and adults. User Manual

Verify with your service provider that their Mini SIM card will work with GSM / 3G GSM type modems before purchasing their Mini SIM card.

MANUAL DOOR INTERCOM 3G AUDIO KEYPAD INTERCOM (ACCESS CONTROL SYSTEM) For 200 Apartments. For your protection, read these instructions completely

GPS Vehicle and personal location tracker

GPS Vehicle and personal location tracker

GSM Communicator GJD710 PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE YOU START THE INSTALLATION COMMUNICATOR FIT INSTALLATION INSTRUCTIONS

Please read and retain these instructions for future reference v002: 14/03/17. Cradle, Charger, Instruction manual, Lithium-ion Battery 3.7 V d.c.

GSM AD05 Slave GSM Auto Dialer- Instruction Manual

Fixed Wireless Phone. User Manual

GSM communicator G09 (v.1.61) User Manual and Installation Guide. Draugystes g. 17, LT Kaunas

AV-4000 GSM AV-4000 DVR

GSM Communicator PSTN SIA DC-05 Protocol to SIA DC-09 Protocol & SMS Alert

FIFOTRACK MOTORCYCLE/VEHICLE GPS TRACKER

MetaDolce MD3600 IP65 Multi-Data Capture Tablet Quick Manual. 1. Keys and Connectors

rev mobile device to remotly control your home 2010 Cybrotech Ltd

MANUAL 3G GATE OPENER

Vehicle and personal location tracker

GSM-AUTO GSM Controller User manual

3G VIDEO BOX (WCDMA) USER GUIDE

CCTR-820 Mini Water-proof GPS Tracker Using Guide

INDEX. Network Power Monitor NPM-R10-SNMP. Innovative Electronics for a Changing World. NPM-R10-SNMP Remote Network Power Monitor

GSM communicator G16 USER MANUAL

FIFOTRACK VEHICLE GPS TRACKER. Model: S30 Version: V1.1

QTech SMS Lite Quick Start Guide

CCTR-628 Long Standby Time GPS Tracker Using Guide

Short guide. Trackunit 401 SmartID. Version 1.4, June 2014

WiLARM-ContactID GSM Module Installation Guide Version: 2.0

Operation Manual GSM modem irz TG42-232

STD Simple Telemetry Application. Owner s Manual

MobilGate - 128d. 1. Operation of MobilGate-128d. Gate and barrier control GSM module with 2 inputs and 2 outputs for 128 phone numbers

Please read and retain these instructions for future reference. Cradle, Charger, Instruction manual, 3.7V Lithium-ion battery included.

GPS/GPRS/GSM Super GPS Tracker User Manual UM209

Vehicle Tracker User Manual

MobilTherm 2ad. 1. How the interface works: GSM temperature alarm module with auxiliay inputs and relay outputs

Comsec Protection Systems

GSM module G10 (v.1.3x) User manual. JSC UAB TRIKDIS Draugystės str. 17, LT Kaunas LITHUANIA Webpage:

Aspera R25t User Manual

CCTR-829 GPS Tracker Using Guide

FutureConnect. Quick Installation Guide. communication experience

DESSMANN - FINGERPRINT LOCK. User Guide G800FPC TX - with SMS Function

Z-Wave Ceiling-mount Smoke Detector HZS-200E/HZS-200A

UP200-GSM Intercom and access control unit operating on mobile GSM network

GSM AUTO DIALER WITH IR BEAM DETECTOR

GSM/GPRS/GPS Tracker (LDW-TKV116) User Manual. Version 1.4

MANUAL PIN CODE KEYPAD February 2013

GSM WATER PUMP CONTROLLER AND MONITORING SYSTEM Model: GSM-0308WPC

MEITRACK MVT340 User Guide

GSM module G10. User manual. (v.1.xx) JSC UAB TRIKDIS Draugystės str. 17, LT Kaunas LITHUANIA Webpage:

KAUGJUHTIMISSÜSTEEMID TELECONTROL SYSTEMS MODEM TELEM-GSM/GPRS 3G. User manual

T 103 V h e i h c i l c e l Tr T ac ac e k r U e s r e Man an al P e r f e a f c a e

MobilSwitch - Micro. 1. Operation: General purpouses GSM remote signal and remote control modules with 2 inputs and 2 relay outputs

HydroGuard Expert Pool Manual

1. Short description. 2. Features. 3. Technical parameters

DESSMANN - FINGERPRINT LOCK

JVA SMS Gateway User Manual

GSM communicator G17F INSTALLATION MANUAL

GPS Vehicle Tracker User Manual

EZY SWITCH. SMS-8 System Monitor Installation Manual Applicable for firmware version 1.1 or above

TUTA S30. GSM Power Socket. User Manual Manual version 1.3

gavc 1200 EVCD Accessories GSM board Product number : 94042

C.D. Products S.A. 1

GSM/GPRS/GPS TK303 Long Time Standby Tracker User Manual

SMM Series 3G and GSM Modems. Quick Start Guide. Document Number: Version: 1.2 (20 October, 2015)

MSS-UP200-GSM Single Dwelling GSM Intercom Unit. Operation Manual. [Ver /5/2015]

GSM POWER OUTAGE ALARM SYSTEM (Single Phase) Model: GSM-0308POA1P

Limmex Emergency Watch

1 BUTTON GSM INTERCOM WITH KEYPAD (3G)

Installation Manual & User Instructions

Manual Simatek Control Unit GFC 32

CoverTitle. Raven XT. Quick Start Guide for AT&T Rev 3.0E

UAB TRIKDIS Draugystės str. 17, LT Kaunas LITHUANIA Webpage: GSM communicator G10. (v.1.

HI GSM Supervisor. Instruction Manual

GPS Vehicle Tracker (GPS+GSM+SMS/GPRS) User Manual (A5E-3)

EA-GSM-Interface-GB.odt

ELA FLOAT LEVEL SWITCH 1 ELA. ELA 100 ELA 200 ELA 305s ELA 400 ELA 500 ELA 600 ELA 600/GSM

B-33. Hardware and Install Manual. (DC 12V / PoE)

Transcription:

A1400 GSM Temperature Alarm USER MANUAL A1400-REV2.1-1604 FW-A1400v2.94 ERBAŞ TEKNOLOJİ Innovative Solutions 1 www.erbasteknoloji.com

SAFETY INSTRUCTIONS - This user manual contains important notices for installation, usage and safety instructions. Please read this manual carefully before you start using your device! - Device is containing a radio transceiver operating on GSM 900/1800 MHz bands. - Do not use device in environments, exceeding temperature limits (device should operate not lower than -10 0 C and not higher than +50 0 C). - Do not use device in chemical or other hazardous environments. - Device is intended to use in dry and clean places. Do not use device in high humidity. - Protect your device from dust, moisture, heat and water. - Do not expose the device to strong vibrations and mechanical impacts. - Do not attempt to repair device personally. USE IN ACCORDANCE WITH THE REGULATION - The use of this device in accordance with the regulation is sending SMS text messages and making phone calls after an alarm case. Other usages are not permitted. - Police, fire or healthcare emergency call lines are not permitted to call directly from this device. Do not configure emergency call numbers into this device. BATTERY RECYCLING - CR123A batteries are classified as recycled batteries. Please take your empty batteries to a nearest collection point. BATTERY LIFE - Battery life, announced by manufacturer, is calculated under normal operating conditions and normal frequency of usage. - Battery life can vary against frequency of usage, quality of cellular service, environment conditions (temperature, humidity etc.), quality of used batteries and other effects. - Manufacturer does not guarantee battery life of the device operation. LIMITED LIABILITY - The buyer must agree that Reporter devices will reduce the risk of theft, burglary, fire or other dangers but do not guarantee against such events. - Manufacturer will not take any responsibility regarding personal or property or revenue loss while using devices. - Manufacturer liability according to local laws does not exceed value of the purchased device. 2

1. DESCRIPTION A1400 is a simple & easy to use GSM Temperature Alarm Device which sends SMS and calls you in case of alarm events. Alarm event occurs in case of High Temperature, Low Temperature, Temperature Restoration and Cable Fault alarms. Up to 3 numbers can be registered (1 admin, 2 users). Temperature high and low values can be set by simple SMS. A1400 also operates as Power Failure Detector, if used together with power adaptor. Sends you POWER FAIL message in case of power adaptor fails and sends you POWER OK message in case of power restored. Device understands Power Failures and Power Restorations from the adaptor voltage. Once battery is low, device sends you LOW BATTERY text message. Battery voltage is checked daily and text message is sent if it is low. It will repeat this message every week after the first alert, as soon as batteries are not replaced. Device sends you STILL ALIVE messages once per week (6~8 days). This message shows that device is working well (means battery or power is OK, SIM card is OK, no errors). This function can be disabled / enabled by admin (Factory default is: enabled). Device also sends you GSM Signal Strength Level while making configuration. This will help you to understand if the location is suitable for installation or not. Below list shows the feedbacks from your device: - High Temperature : Text Message TEMP:+056 C and phone call (ring) - Low Temperature : Text Message TEMP:-017 C and phone call (ring) - Temp. Restored : Text Message OK:+020 C and phone call (ring) - Temp. Cable Fault : Text Message CABLE FAULT and phone call (ring) - Power Failure : Text Message POWER FAIL - Power Restored : Text Message POWER OK - Low Battery : Text Message LOW BATTERY - Weekly Keep Alive : Text Message STILL ALIVE A1400 might operate in below power options: - Adaptor + battery used together: In this case all functions will work and battery lifetime is up to 4 years. - Battery-only use: In this case battery lifetime is 1 year (calculated 1 SMS per day). In this mode Power Failure and Power Restoration functions will not work. - Adaptor-only use: In this case Power failure function will not work. Note that Reporter devices do not have voice record function, so phone calls are used for only ringing your mobile phone. There is no voice call. Only a local 900/1800MHz GSM SIM card is required to operate the device. SMS and Call function is enough for SIM Card. Data or GPRS functions are not required. Reporter devices are designed to operate in ultra-low power consumption. Further to this feature; device de-attaches itself from GSM network in standby, for saving battery life. If you try to call or send SMS to device in standby mode, you will not be able to reach the device. It attaches to the network if an alarm occurs or if you press Config Button. 3

All settings and registered admin & user numbers are saved in device s own EPROM memory. So, settings will not be deleted if battery or SIM card is removed. Device will continue with new batteries or new SIM Card with the last saved settings & numbers. 2. GETTING STARTED 2.1. Insert SIM Card A local SIM card is required to operate the system. Before inserting the SIM card, try it with a mobile phone. And then: o o o Disable PIN code protection Send an SMS to a mobile number for testing Call a mobile phone number for testing After above steps; please open the screws on the back of the item. And please insert SIM card into your device, by opening the SIM card holder. Once SIM card is inserted, please lock the holder. 2.2. Connect Temperature Probe Connect RED (+) wire of temperature probe into terminal 3. Connect WHITE (-) wire of temperature probe into terminal 4. 2.3. Connect Power Connect 12V DC power adaptor into terminal block numbers 1 and 2. Number 1 is positive (+12V) and 2 negative (GND). 4

Note: Wires should pass into the holes of the top cover! Please check Wiring Diagram! Connect +12V of power adaptor to the terminal block 1. Connect GND of power adaptor to the terminal block 2. Please note power adaptor current should be at least 1000 ma. Then insert two pieces of CR123A batteries included in the package. (If power adaptor is not used, insert batteries only). 2.4. Register Admin Number Admin number is authorized to make configurations, change & delete settings of the device. And also will receive all alerts with SMS and/or phone calls. Other users will only receive alerts and will not be able to make configurations. The LED will blink a few times until it is connected to an available network. Please wait for LED becomes solid ON. Once LED is ON; that means device is connected to a GSM network and ready to work. Now please call the device s number with your phone. Once you hear the ringing volume, your number is registered to devices memory as ADMIN NUMBER. Then the LED will blink and device will send you an SMS including ADMIN OK message. Once you received this message that means device is ready to work and now operating! If you want to make some changes on settings please continue from below steps. 2.5. Send Configuration Commands Press config button for 3 seconds and wait LED becomes solid ON. Now your device is waiting for a configuration SMS from you (note that timeout is 2 minutes). Please note all commands should start with an admin password (except RESET command). Default password is 1111. Also, it is possible to send one or several commands in one SMS. Commands should be written in big letters (correct one: 1111 NEWP:3333, wrong one is: 1111 newp:3333). There should be a space character between independent commands e.g.: 1111<space>NEWP:1234<space>DEL1<space>DISABLE Device is case sensitive; please pay attention to text message ingredients. Attention: If you write the password wrong you will receive an SMS including WRONG PSWR text. In that case device will keep in configuration mode. Please wait until LED becomes solid again and send a configuration SMS with correct password. Otherwise device will keep the same settings and continue operation after 2 minutes timeout and LED will become OFF. Below is the list of commands: DESCRIPTION COMMAND DEFAULT Change Password NEWP:XXXX 1111 Add / Change User1 TEL1:+XXXXXXXXXX Add / Change User2 TEL2:+XXXXXXXXXX 5

Delete User1 DEL1 Delete User2 DEL2 Enable Keep Alive ENABLE Enabled (Weekly) Disable Keep Alive DISABLE Enabled (Weekly) Reset Device RESET Temp High Set in 0 C TEMPH:+XX or -XX (set between -55 to +99) +08 Temp Low Set in 0 C TEMPL:+XX or -XX (set between -55 to +99) +02 EXAMPLE: Table 1 Commands List 1111 NEWP:5555 TEL1:+906661234567 TEMPL:-17 TEMPH:+45 Above example means: o New admin password is now 5555 and you have to use this new password to make new configurations in the future. Please note it carefully. o You added a new user1 number +906661234567. o Temp High set value is set to +45 C o Temp Low set value is set to +17 C Once you sent this SMS to your device, it will reply you with an SMS including: CONFIG OK 26 TEMPL:-17 TEMPH:+45 Where 26 is GSM signal strength, see Table-2 for further details. TEMPL is Low Temperature saved limit, TEMPH is High Temperature saved limit. Note: Make sure that TEMPH value is higher than TEMPL value. Otherwise this will cause wrong alarm! Note: Make sure that device replied with the right values you want to set for. If the values you sent to device and the values device replied you are different; that means there is a wrong sequence. All temperature values should be written in two letters and should start with the + or - sign (i.e. -23, -08, +00, +05, +23, +85 are correct ones). Otherwise device will keep the previous settings. Now LED will turn off and your device is ready to operate. Finally close the cover and insert screws on the back. <XX> MEANING ADVICE Between 19~31 Excellent Signal Between 14~18 Good Signal Between 9~13 Workable Signal Try changing location Between 1~8 Weak Signal Check antenna / change device location Table 2 GSM Signal Strength Levels 6

3. RESET & RECONFIGURE 3.1. Re-configure Your Device Press at least 1 second to the Configuration Button on your device anytime. LED will blink a few times and please keep waiting for LED becomes solid ON. Then you might send a new configuration SMS to device with using your latest password. The procedure of sending configuration SMS is same with article 2.5. Send Configuration Commands. 3.2. Check GSM Signal Strength Please follow article 3.1 and then only send your last password with SMS. You will receive CONFIG OK <XX> text message where <XX> indicates GSM Signal Strength. For further description please see Table-2. 3.3. Reset Your Device Press Configuration button at least 1 second. LED will blink a few times and please keep waiting for LED becomes solid ON. Then send an SMS to the device including RESET command. LED will blink 10 times quickly. Now your device has been reset, it is ready to start. Please follow instructions starting from 2.4. Register Admin Number. Please note that RESET can be only made by sending RESET text message to your device (while it s in config mode). Password is not required for Reset function. Also Reset can be made from any third person s mobile phone; Admin or users not required to make Reset. 4. TROUBLESHOOTING TROUBLE REASON SOLUTION I received ADMIN OK, I sent a config SMS but didn t receive CONFIG OK text SMS is sent while LED is blinking or LED is OFF Wait for LED is solid OFF. Then press config button 1 sec. Wait for LED blinks and becomes solid ON. Then send your SMS. LED blinks continuously in first use, never becomes solid ON SIM card not inserted Remove batteries and adaptor. Insert SIM card first and then power device. PIN code not disabled Remove batteries, adaptor and then SIM card. Insert SIM card into a mobile phone. Disable SIM Card PIN protection from settings. Insert SIM card to your device first and then power device. Signal level not enough (below 13) Change device location or try with another GSM operator until finding good signal level. I don t use batteries but I receive LOW BATTERY text messages. Alarm occurred, I received SMS but didn t receive a Call Alarm occurred, I received Call but didn t receive an SMS I (admin) receive SMS & Calls on alerts but users don t. I receive POWER FAIL but don t receive POWER OK texts. My batteries finished very quickly Batteries not used Network signal was not enough on Reporter location or your own mobile phones location. Low credit on prepaid card Network signal was not enough on Reporter location or your own mobile phones location. Low credit on prepaid card Users not saved correctly Adaptor not powered or wiring is wrong Device worked without SIM card or PIN code not disabled or signal is too low Please use batteries for safer operation. Otherwise you will receive LOW BATTERY alarms with weekly repeat. Check signal level of Reporter. Check if you had a missed call while your mobile phone is unreachable. Check your credit (if prepaid cards used). Check signal level of Reporter. Sometimes SMS messages are delivered after some period of its sent, caused by GSM operators. Check your credit (if prepaid cards used). Config messages are correct. Read Reconfigure your device section and make configuration. Check if adaptor is powered by mains. Check adaptor connection on 1&2 (It might be connected opposite). Replace with fresh batteries. Check signal level. Disable PIN code protection. 7

5. TECHNICAL SPECIFICATIONS A1400 Technical Specifications Power Supply 2 x CR123A Lithium batteries (NOT included) 12V 1000mA DC Adaptor (included) Battery Life More than 1 year under normal usage Inputs Digital temperature input Power adaptor input Outputs Not available Sampling Freq. & Accuracy 1 sample per minute, +/- 1 C accuracy GSM Module GSM 900/1800 MHz Dual Band Antenna Internal Antenna Event Alerts SMS / Call in case of Temperature Limits Exceeds SMS / Call in case of Temperature Restored SMS / Call in case of Temperature Cable Fault / Broken SMS for Power Failure SMS for Power Restored SMS for Low Battery SMS for Keep Alive Messages SMS for GSM Signal Strength and Set Levels (while configuration) Configurations via SMS Change security password Set high and low temperature limits Register & delete user phone numbers (up to 2) Enable & disable weekly keep alive messages Reset device Operating Temperature -10 0 C ~ + 50 0 C Dimensions 109 x 58 x 31 mm Package Content 1 x A1400 GSM Temperature Alarm 1 x A9900 12V 1000mA Power Adaptor 1 x A9910 Digital Temperature Probe 1 x User Manual 4 x Fixing Screws & Fixing Plugs Made in Turkey 8