FlexArmor 24V dc Sinking Input Modules

Similar documents
ControlLogix Redundant Power Supply Chassis Adapter Module

ArmorBlock MaXum 4 Output Module Series B

ArmorBlock MaXum 8 Input / 8 Output Module Series B

FLEX I/O EtherNet/IP Adapter Module

ArmorBlock MaXum Robot I/O Cable Base and Kempf Box Plate

Allen-Bradley PL. ControlLogix Drive Module. Installation Instructions. (Catalog Numbers: 1756-DMD30 and 1756-DMF30)

ControlLogix DC (10-30V) Isolated Output Module

ControlLogix DC ( V) Electronically Fused Output Module

ControlNet PCI Communication Interface Card

FLEX Integra 4 Input Module

FLEX Integra 2 Input/2 Protected Output Module

POINT I/O Protected Output Module

POINT I/O Source Input Module

POINT I/O 120/220V ac Output Module

ControlLogix Ethernet Communication Interface Module

ControlLogix Isolated Analog Voltage/Current Input Module

Digital Expansion Terminal Block CompactBlock LDX I/O

ControlLogix RTD Input Module

ControlLogix Thermocouple Input Module

Barrel Temperature Control Module

ControlLogix DeviceNet Scanner Module

CompactBlock I/O for DeviceNet Modules Series D

POINT I/O 2 Voltage Input Analog Module

DeviceNet CompactPCI Communication Interface Card

ControlLogix DH-485 Communications Module

dc (10 60V) Output Module

XM-124 Standard Dynamic Measurement Module

POINT I/O RTD Input Module

EtherNet/IP Modules. Installation Instructions

ControlLogix-XT EtherNet/IP Bridge Module

ControlLogix Controller and Memory Board

MicroLogix 1762-IQ16 DC Input Module

DeviceNet Analog Base Terminal Block CompactBlock LDX I/O

POINT I/O 120V AC Input Module

POINT I/O 24V DC 4-channel Discrete Input Module with Diagnostics

FLEX I/O 240V AC Digital Input and Output Modules

AB PLC. CompactBlock Distributed I/O on PROFIBUS DP Series D. Installation Instructions. (Cat. No. 1791P-16B0, -0B16P, -8B8P, -4B4P, -8V8P)

FLEX I/O Digital Input/Output Modules

POINT I/O 2 Current and 2 Voltage Input Analog Modules

Ethernet Network Appliance (with Network Address Translation)

Stratix 6000 Ethernet Managed Switches

CompactLogix EtherNet/IP Web Server Module

MicroLogix 1762-IQ32T DC Input Module

Analog Output Module

POINT I/O Synchronous Serial Interface Absolute Encoder Module

InView Marquee Message Display

POINT I/O Output Module

ControlLogix EtherNet/IP Bridge Module

MicroLogix 1762-OB32T Solid State 24V DC Source Output Module

FLEX I/O Digital DC Output Modules

FLEX I/O AC Digital Output Modules

POINT I/O 2 and 4 Relay Output Modules

Installation Instructions

User Manual. XM ControlNet Adapter Catalog Number 1440-ACNR

Installation Instructions

POINT I/O 4 Channel Analog Current Output Module

DeviceNet Base RTD and Thermocouple CompactBlock LDX I/O

POINT I/O 8 Channel High Density Current Input Module

1769 Compact I/O Communication Bus Expansion Cables

POINT I/O Synchronous Serial Interface Absolute Encoder Module

POINT I/O 2 Current Output and 2 Voltage Output Analog Modules

ControlLogix ControlNet Bridge Module

Compact 1769-OF4VI Isolated Analog Output Module

Compact 1769-OF4CI Isolated Analog Output Module

CompactLogix 5370 Controllers

PROFIBUS DP Analog, RTD and Thermocouple Base Terminal Block CompactBlock LDX I/O

MicroLogix 1200 Isolated Relay Output Module

Ethernet PLC-5 Programmable Controllers

User Manual. EtherNet/IP and ControlNet to FOUNDATION Fieldbus Linking Devices

1769-L31 CompactLogix Controller

1719 Ex I/O. Installation Instructions

ControlNet Universal PCI Communication Interface Card

ControlLogix ControlNet Interface Module

Installation Instructions

Installation Instructions

Micro800 Digital Relay Output Plug-in Module

1734 POINT I/O Dual Port EtherNet/IP Adapter

Remote I/O Scanner. Installation Instructions. (Catalog Number 1747-SN)

POINT I/O EtherNet/IP Adapter

Compact I/O ASCII Module

Micro800 8-Point Input and 8-Point Output AC Modules

POINT I/O 5V DC and 24V DC Very High Speed Counter Module

Solid-State Output Module

Installation Instructions

Micro Point Programmable Controllers

Micro820 Programmable Controllers

Compact I/O DeviceNet Scanner Module

Remote I/O Adapter Module

Micro820 Programmable Controllers

Micro Point Programmable Controllers

1719 Ex I/O. Installation Instructions. Original Instructions

Installation Instructions

You cannot install the module unless the connector is fully extended. ATTENTION: Allen-Bradley HMIs

MicroLogix 1762-OV32T Solid State 24V DC Sink Output Module

Compact 120V ac Input Module

XM-440 Master Relay Module

POINT I/O 24V DC Expansion Power Supply

PanelView Plus/VersaView CE Terminals and Display Modules

MicroLogix 1762-IQ32T DC Input Module

PanelView 800 HMI Terminals

Transcription:

Installation Instructions FlexArmor 24V dc Sinking Input Modules Catalog Number 1798-IB4 & 1798-IB8 42638 The FlexArmor I/O modules (Cat. No. 1798-IB4 & 1798-IB8) mount in a FlexArmor Baseplate. Use compatible sealed cordsets to connect all field side wiring. The 1798-IB4 module provides connections for up to 4 inputs. The 1798-IB8 module provides connections for up to 8 inputs. Both of these modules have four 12 mm connectors. Inputs are 24V dc configured for sourcing devices. A diagnostic feature for both modules includes sensor power short-circuit detection.

2 FlexArmor 24V dc Sinking Input Modules Package Contents Your package contains: 1 FlexArmor -IB4 or -IB8 module installation instructions (Note: Baseplates and other components are ordered and shipped separately.) European Union Directive Compliance If this product has the CE mark it is approved for installation within the European Union and EEA regions. It has been designed and tested to meet the following directives. EMC Directive This product is tested to meet Council Directive 89/336/EEC Electromagnetic Compatibility (EMC) and the following standards, in whole or in part, documented in a technical construction file: EN 50081-2 EMC - Generic Emission Standard, Part 2 - Industrial Environment EN 50082-2 EMC - Generic Immunity Standard, Part 2 - Industrial Environment This product is intended for use in an industrial environment. Low Voltage Directive This product is tested to meet Council Directive 73/23/EEC Low Voltage, by applying the safety requirements of EN 61131-2 Programmable Controllers, Part 2 - Equipment Requirements and Tests.

FlexArmor 24V dc Sinking Input Modules 3 For specific information required by EN 61131-2, see the appropriate sections in this publication, as well as the following Allen-Bradley publications: Industrial Automation Wiring and Grounding Guidelines For Noise Immunity, publication 1770-4.1 Automation Systems Catalog, publication B113 Related Publications For software configuration information, refer to the 1798-ADN User Manual, publication 1798-UM001A-US-P and the 1798-APB User Manual, publication 1798-UM002A-EN-P. Install Your FlexArmor I/O Module To install the module: Install the modules into the Baseplate Connect the cordsets Communicate with the module These steps are explained in more detail in the following procedures. For instructions on how to mount the FlexArmor Baseplate, refer to publication no. 1798-IN003A-EN-P.

4 FlexArmor 24V dc Sinking Input Modules Install the Modules into the Baseplate To install the modules into the Baseplate: 1. Hold the module at an angle and engage the top of the module in the indention on the rear of the Baseplate. 2. Press the module down flush with the panel until the locking lever locks. 3. Repeat these steps for each I/O module and each remaining Baseplate I/O slot. IMPORTANT I/O modules can be installed in any slot location to the right of the adapter module. The adapter is capable of addressing up to eight I/O modules. Screw down the module retaining screws to ensure IP67 compliance. IMPORTANT Torque the screws to 0.5-0.7 Nm. (4.43-6.2 inch pounds). Dust caps must have 4 inch pounds of torque to maintain IP67 compliance.

FlexArmor 24V dc Sinking Input Modules 5 Connect the Cordset to the FlexArmor Module These modules use 5 pin micro (12mm) style PCB mounted connectors. Four micro caps cover the I/O connectors on both modules. Remove the caps and connect your cables to the appropriate ports. Keep the caps in place on any unused connector to maintain the IP67 rating. Refer to publication no. 889-CP0021A-EN-P for compatible Rockwell Automation cables and cordsets. A pinout diagram for the connectors is shown below. 42652 Input Micro-Connector (View into Socket) Pin 1 Sensor Power Pin 2 Input B (IB8 module only) Pin 3 Sensor Common Pin 4 Input A Pin 5 Not Used ATTENTION Make sure all connectors and caps are securely tightened to properly seal the connections against leaks and maintain IP67 requirements. For maximum noise immunity, input and output cable return wires must be properly terminated. When inputs and outputs are connected in loopback, return wires should be connected together. I/O cable length should be less than 30 meters.

6 FlexArmor 24V dc Sinking Input Modules Communicate with Your FlexArmor System The FlexArmor DeviceNet adapter module supports multiple communication choices. The network master makes the actual communication choice. The choices are: Polled - data is sent by the adapter in response to received data. Strobe - data is sent by the network in response to the strobe command. The single bit allocated to the adapter in the strobe message is not used. If the configured size of the input data (sent from the adapter) is greater than 8 bytes, the strobe connection establishment will fail. In this case, the input size must be re-configured to 8 bytes or less. Change of State - data is sent by the adapter based on detection of any changed value within the input data. Data is independently received based on change of state from the sender. Data in both directions can be acknowledged or unacknowledged depending on the run time configuration of the system. Cyclic - data is sent cyclically by the adapter based on a configured time value. Data is independently received cyclically from the sender. Data in both directions can be acknowledged or unacknowledged depending on the run time configuration of the system. Troubleshooting with the Indicators The following table describes status indicators on digital input modules. I/O Status Indicators Function Indicator Status Inputs Inputs Yellow Input ON Off Input OFF Fault LED Red Off Sensor Power Short Normal

FlexArmor 24V dc Sinking Input Modules 7 Specifications Input Module Specifications Specifications 1798-IB4 1798-IB8 Module Type Digital Input, Sinking Digital Input, Sinking Number of Channels 1 group of 4 1 group of 8 Sensor Source Current 400 ma maximum 400 ma maximum On-state Voltage 10-28.8V dc; 24V dc nominal 10-28.8V dc; 24V dc nominal On-state Current 2-12 ma; 8 ma @ 24V dc 2-12 ma; 8 ma @ 24V dc Off-state Voltage 5V dc maximum 5V dc maximum Off-State Current 1.5 ma minimum 1.5 ma minimum Channel Impedance 4.6KΩ maximum 4.6KΩ maximum Isolation Voltage 850V dc channel-to-system for 1s 850V dc channel-to-system for 1s Delay Times: Off to On On to Off 256 us, 512 us, 1 ms, 2ms 4 ms, 8 ms, 16 ms, 32 ms (Selectable; 256 us default) 256 us, 512 us, 1 ms, 2ms 4 ms, 8 ms, 16 ms, 32 ms (Selectable; 256 us default) FlexBus Current 20 ma maximum 20 ma maximum Power Dissipation 2.0W @ 28.8V dc 3.0W @ 28.8V dc Thermal Dissipation 6.8 BTU/hr. @ 28.8V dc 10.2 BTU/hr. @ 28.8V dc Indicators 4 channel status - yellow 4 fault LED indicators- red 8 channel status - yellow 8 fault LED indicators - red External DC Power Voltage (24V dc nom.) Current Dimensions (H x D x W) Environmental Conditions: Operating Temperature Storage Temperature Shock: Operating Non-Operating Vibration Conductors Enclosure Agency Certification (When product is marked) 10-28.8V dc; 5% AC ripple 450 ma maximum 118 mm X 57 mm X 40 mm 4.63 in. X 2.25 in. x 1.58 in. -20 to 60 C (-4 to 140 F) -40 to 85 C (-40 to 185 F) 30G peak, 11±1 ms pulse width 50G peak, 11±1 ms pulse width 5G @ 10-500 Hz per IEC 68-2-6 See publication DN-6.7.2 Meets IP67 10-28.8V dc; 5% AC ripple 500 ma maximum 118 mm X 57 mm X 40 mm 4.63 in. X 2.25 in. X 1.58 in. -20 to 60 C (-4 to 140 F) -40 to 85 C (-40 to 185 F) 30G peak, 11±1 ms pulse width 50G peak, 11±1 ms pulse width 5G @ 10-500 Hz per IEC 68-2-6 CUL listed UL Hazardous Class 1, Division 2, Groups A, B, C, D certified CE marked for all applicable directives marked for all applicable acts N223

8 FlexArmor 24V dc Sinking Input Modules Hazardous Location Approval The following information applies only to products marked with Hazardous Location Approval, when operating in hazardous locations: Products marked CL I, DIV 2, GP A, B, C, D are suitable for use in Class I Division 2 Groups A, B, C, D, Hazardous Locations and nonhazardous locations only. Each product is supplied with markings on the rating nameplate indicating the hazardous location temperature code. When combining products within a system, the most adverse temperature code (lowest T number) may be used to help determine the overall temperature code of the system. Combinations of equipment in your system are subject to investigation by the local Authority Having Jurisdiction at the time of installation. WARNING EXPLOSION HAZARD - Do not disconnect equipment unless power has been removed or the area is known to be nonhazardous. Do not disconnect connections to this equipment unless power has been removed or the area is known to be nonhazardous. Secure any external connections that mate to this equipment by using screws, sliding latches, threaded connectors, or other means provided with this product. Substitution of components may impair suitability for Class I, Division 2. If this product contains batteries, they must only be changed in an area known to be nonhazardous. WARNING Use supply wires suitable for 30 C above surrounding ambient.

FlexArmor 24V dc Sinking Input Modules 9 WARNING When used in a Class I, Division 2, hazardous location, this equipment must be mounted in a suitable enclosure with proper wiring method that complies with the governing electrical codes. Les informations suivantes ne concernent que les produits marqués pour une utilisation en environnements dangereux : Les produits marqués «CL I, DIV 2, GP A, B, C, D» ne conviennent qu à une utilisation en environnements de Classe I Division 2 Groupes A, B, C, D dangereux et non dangereux. Chaque produit est livré avec des marquages sur sa plaque d identification qui indiquent le code de température pour les environnements dangereux. Lorsque plusieurs produits sont combinés dans un système, le code de température le plus défavorable (code de température le plus faible) peut être utilisé pour déterminer le code de température global du système. Les combinaisons d équipements dans le système sont sujettes à inspection par les autorités locales qualifiées au moment de l installation. AVERTISSEMENT RISQUE D EXPLOSION - Couper le courant ou s assurer que l environnement est classé non dangereux avant de débrancher l équipement. Couper le courant ou s assurer que l environnement est classé non dangereux avant de débrancher les connecteurs. Fixer tous les connecteurs externes reliés à cet équipement à l aide de vis, loquets coulissants, connecteurs filetés ou autres moyens fournis avec ce produit. La substitution de composants peut rendre cet équipement inadapté à une utilisation en environnement de Classe I, Division 2. S assurer que l environnement est classé non dangereux avant de changer les piles.

10 FlexArmor 24V dc Sinking Input Modules AVERTISSEMENT Utiliser des fils d alimentation qui conviennent à une température de 30 C au-dessus de la température ambiante. AVERTISSEMENT Pour une utilisation en environnement de classe i, division 2 dangereux, cet equipement doit etre monte dans un boitier avec un cablage approprie conforme aux normes electriques en vigueur.

FlexArmor 24V dc Sinking Input Modules 11 Notes:

Allen-Bradley is a registered trademark of Rockwell Automation. DeviceNet is a trademark of Open DeviceNet Vendor Association (ODVA). RSNetWorx for DeviceNet is a trademark of Rockwell Software, Inc. PN 957259-70 2001 Rockwell International Corporation. Printed in USA