TeSys UASILUFC5 - ASILUFC51 AS-i Communication Module

Similar documents
TeSys U LULC07 Profibus DP Communication Module

TeSys U Communication Variables

TeSys U LUTM Controller

Acti 9 Communication System

TeSys U LUTM Controller User Manual 03/

LULC031 Telemecanique

Ethernet Modbus X80 Gateway Device Type Manager

LUTM TeSys Model U Controller User s Manual 02/2005

TeSys U LULC Modbus Communication Module

TeSys U LULC09 DeviceNet Communication Module

EcoStruxure Power Commission Installation Guide

5521 Potentiometer Analog Input Module

5504 Thermocouple Analog Input Module

Altivar 61/71 Adjustable Speed Drives Heatsink Fan Kits VZ3V1212 and VZ3V1216

XPSMCMx Fieldbus Expansion Modules Instruction Sheet (Original Language)

Schneider Electric Floating License Manager

5401 and 5402 Digital I/O Modules

Schneider Electric License Manager

Schneider Electric AB DH485 Protocol XBT N/R/RT

Packaging User Guide for Temperature Control M221 Project Template

Clipsal Bus Couplers. Two Channel (SLC5102BCLEDL) and Four Channel (SLC5104BCL) for Use with C-Bus Wired Systems

Unity Pro OSLoader User Manual

SCADAPack E 5405 Digital Input Hardware Manual

170 ADM to 60 VDC Module Base / 170 ADO Pt. Relay Out Module Base. Version 1.0

Operating instructions. Switching amplifier DN0210 DN / / 2015

EIO /2011. Magelis HMISTO501. Zelio/Millenium Driver 07/2011 EIO

Installation Instructions

Operating instructions ClassicLine module AC5203 / AC5205 AC5208 / AC5211 AC5213 / AC5214 AC5215 / AC5233 AC /00 02/2015

TeSys T LTM R EtherNet/IP with a Third-Party PLC Quick Start Guide

5403 and 5404 Digital Input Modules

AS-Interface Bus for Modicon M340

LXM32. Explanation for detected error E 733F. Expert Support Machine Solution

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

SoMachine Scan for Buttons Linked to ZBRN Modules Harmony ZBRN Library Guide

Operating instructions. Speed monitor D / / 2014

MANUAL VAA-2E2A-G12-SAJ/EA2L Original Instructions Version 1.0

Digital encoder interface module 5/12/24 V DANGER

SCADAPack E Target 5 DF1 PLC Interface

Installation Instructions Temperature transmitter TAA /00 06/2011

AS-i Safety Relay Output Module with Diagnostic Slave

Twido Programmable Controllers Discrete I/O Modules

Altivar 61/71. Variable speed drives for synchronous and asynchronous motors. POWERLINK Communication Manual VW3A /2013

SCADAPack E Idec PLC Interface Manual

PHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller),

GV3000/SE AC Drive ControlNet Network Communication Option Board M/N 2CN3000

Electrical network protection Sepam series 20 Sepam series 40 Quick start

Profinet Module. User Manual. Contents

SMVector Additional I/O Module Installation and Operation Manual

X-12s Users Manual. X-12s User Manual Revisions Revision Description Initial release. Xytronix Research & Design, Inc.

AS-i Safety Relay Output Module with Diagnostic Slave

SCADAPack E 5505 RTD Input Hardware Manual

TeSys IEC Contactors and Overload Relays

Digital ac/dc (24V) Input Module

Redundancy unit CP-A RU

Modicon TM3 Expert I/O Modules Hardware Guide

TRIO-DIODE/12-24DC/2X10/1X20

DriveGuard. Safe-Off Option for PowerFlex 70 AC Drives. User Manual.

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A

Options for ABB drives, converters and inverters. User s manual FDIO-01 digital I/O extension module

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Galaxy Shore Connection 500 kva. Operation 04/

MultiTech Router Commissioning for Com X 200/210/510

PV Rapid Shutdown device

ATS22D75Q soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)

QUINT-BUFFER/24DC/24DC/40

PowerLogic ION7550 RTU option

P3-SCM. General Specifications

Operating instructions ClassicLine module AC5204 / AC5209 / AC5212 AC5235 / AC5236 / AC5237 AC /00 07/2017

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

Model DPDT Switch Module

ARA Automatic Recloser

PowerLogic High Density Metering System 1-Meter Enclosure

Modicon TM3 (SoMachine Basic) Expansion Modules Configuration Programming Guide

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

Allen-Bradley Drives

Redundancy Module QUINT-DIODE/40

ATS22C17Q. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

Serial PROFIBUS Interface

ATS22D62Q soft starter-ats22-control 220V-power 230V(15kW)/ V(30kW)

VLT Line Filter MCC 107 EMC Filter Series VLT Midi Drive FC 280 (K1 K3)

5607 Input/Output (I/O) Module

ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW)

SCADAPack Input/Output Module Hardware Manual. Version: February 2016

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

EIO /2009. Advantys ETB. IP67 Ethernet Block I/O Modules for Modbus TCP/IP User Guide 7/2009 EIO

English. Operating Manual. Conductive point level switch MLR120. Retain for later reference. Companies / brands of GHM

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW)

270 MHz Control Modules

PSR DC/ESP4/2X1/1X2

ekorrps MULTIFUNCTIONAL PROTECTION UNIT CONFIGURATION AND GENERAL CHARACTERISTICS LIB

CC COMPACT DIP SWITCH

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

AS-Interface. I/O modules for use in the control cabinet. AS-Interface SlimLine Compact Modules. Gerätehandbuch. siemens.com.

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

Copyright: December 2017 Nidec Issue: E

XCSR Contactless RFID Safety Switches User Manual

Model Channel TTL I/O

TXM1.8RB. TX-I/O Blinds module

Options for ABB drives. User s manual Emergency stop, stop category 0 (option +Q951) for ACS880-07/17/37 drives

Transcription:

1639093 03/2009 TeSys UASILUFC5 - ASILUFC51 AS-i Communication Module User Manual 03/2009 1639093 www.schneider-electric.com

Schneider Electric assumes no responsibility for any errors that may appear in this document. If you have any suggestions for improvements or amendments or have found errors in this publication, please notify us. No part of this document may be reproduced in any form or by any means, electronic or mechanical, including photocopying, without express written permission of Schneider Electric. All pertinent state, regional, and local safety regulations must be observed when installing and using this product. For reasons of safety and to help ensure compliance with documented system data, only the manufacturer should perform repairs to components. When devices are used for applications with technical safety requirements, the relevant instructions must be followed. Failure to use Schneider Electric software or approved software with our hardware products may result in injury, harm, or improper operating results. Failure to observe this information can result in injury or equipment damage. 2009 Schneider Electric. All rights reserved. 2 1639093 03/2009

Table of Contents Safety Information............................................ 5 About the Book............................................... 7 Chapter 1 Hardware Implementation...................................... 9 Description and Installation.................................................... 10 Connections............................................................... 14 Technical Characteristics..................................................... 17 Chapter 2 Software Implementation....................................... 19 Configuration Software....................................................... 20 Addressing................................................................ 21 Description of the I/O Variables on the ASILUFC5/ASILUFC51 Module................. 22 Managing Faults............................................................ 23 1639093 03/2009 3

4 1639093 03/2009

Safety Information Important Information NOTICE Read these instructions carefully, and look at the equipment to become familiar with the device before trying to install, operate, or maintain it. The following special messages may appear throughout this documentation or on the equipment to warn of potential hazards or to call attention to information that clarifies or simplifies a procedure. PLEASE NOTE Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel. No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material. A qualified person is one who has skills and knowledge related to the construction and operation of electrical equipment and the installation, and has received safety training to recognize and avoid the hazards involved. 1639093 03/2009 5

6 1639093 03/2009

About the Book At a Glance Document Scope This manual describes the implementation, functionalities and operation of the TeSys U AS-i communication module (ASILUFC5 or extended ASILUFC51). Field of application: mainly automation systems in industry and building areas. Validity Note ASILUFC5 and ASILUFC51 can be used with TeSys U power bases (LUB/2B, LUS/2S) only. ASILUFC5 and ASILUFC51 are not compatible with TeSys U controller bases (LUTM). Related Documents Title of Documentation Reference Number ASILUF Communication Module - Instruction Sheet 1743239 TeSys U Communication Variables - User s Manual 1744082 LU B/LU S TeSys U Starters - Instruction Sheet 1629984 LUCM/LUCMT Multifunction Control Units - User s Manual 1743237 LUCM/LUCMT/LUCBT/LUCDT Control Units - Instruction Sheet AAV40504 LUCA/LUCB/LUCC/LUCD Control Units - Instruction Sheet AAV40503 You can download these technical publications and other technical information from our website at www.schneider-electric.com. User Comments We welcome your comments about this document. You can reach us by e-mail at techcomm@schneiderelectric.com. 1639093 03/2009 7

8 1639093 03/2009

Hardware Implementation 1639093 03/2009 Hardware Implementation 1 Overview This chapter describes the installation and technical characteristics of a TeSys U AS-i communication module (ASILUFC5 or extended ASILUFC51). What's in this Chapter? This chapter contains the following topics: Topic Page Description and Installation 10 Connections 14 Technical Characteristics 17 1639093 03/2009 9

Hardware Implementation Description and Installation Introduction The AS-i ASILUFC5 or extended ASILUFC51 communication module connects the TeSys U starterscontrollers to the AS-i wiring system for direct or remote control. The different operation conditions of the AS-i ASILUFC5 or ASILUFC51 AS-i communication module (ASi bus voltage presence, communication fault on AS-i bus, addressing fault,...) are displayed on the front panel by two light-emitting diodes (green and red). Module operation is continuously monitored by self-tests. This is totally transparent to the user. The integration of AS-i V2 functions enables remote module diagnostics via the bus or local diagnostics via the ASITERV2 and XZMC11 addressing terminals. The module must be supplied with a 24V DC auxiliary source and must only be used with the LUC BL 24V DC control units. IMPROPER COMMUNICATION PORT USAGE WARNING Use communication ports for transfer of non-critical data only. The data provided by monitoring contactor status and current levels is delayed by transmission time. Do not use this data for critical control decisions. Verify function settings before starting the motor. Do not use functions such as Run, Stop and Reverse for emergency or critical control applications. Failure to follow these instructions can result in death, serious injury, or equipment damage. 10 1639093 03/2009

Hardware Implementation Description Description of ASILUFC5 or ASILUFC51 different states of LEDs. Light Emitting Diodes (LEDs) Status Meaning Green "Power" LED On AS-i bus voltage present Off No AS-i bus voltage Red "fault" LED On No exchange with the Master (Communication fault on AS-i bus) Addressing fault (address is factory-set to 0) Flashing No 24V DC auxiliary voltage Motor feed engaged in the "TRIP" position Off No fault 1639093 03/2009 11

Hardware Implementation Installation The AS-i ASILUFC5 or ASILUFC51 communication module is easily installed in the power base (LUB /LUS or LU2B /LU2S ) under the LUC BL control unit that locks it into position. It must be assembled in the following order: 1. Install the ASILUFC5 or ASILUFC51 module. 2. Install the LUC BL control unit. Note: The control unit must be 24V DC. 3. The Output control connector can be connected by wire using LUBN11C cable (for LUB /LUS ) or LU9MR1C cable (for LU2B /LU2S ). Note: Direct wiring can be used, for example, to insert external stop control or a voltage interface. 12 1639093 03/2009

Hardware Implementation Once all components have been installed, here are complete power bases: 1639093 03/2009 13

Hardware Implementation Connections Electrical Connections The connections to the AS-i bus and auxiliary 24V DC are made using XZCG connecting accessories. 14 1639093 03/2009

Hardware Implementation Examples of Application Diagrams 1639093 03/2009 15

Hardware Implementation Connection Capacities The following table shows the conductor cross-sections that may be used on ASILUFC5 / ASILUFC51 terminals: Connection Conductor type AS-i / 24V aux Conductor Cross-section (min. - max.) Control / Monitor Conductor Cross-section (min. - max.) 1 conductor Rigid conductor Flexible conductor Flexible conductor with cable end: without an insulating inlet taper with an insulating inlet taper 0.2... 1.5 mm 2 [24... 16 AWG] 0.2... 1.5 mm 2 [24... 16 AWG] 0.25... 1.5 mm 2 [24... 16 AWG] 0.25... 1.5 mm 2 [24... 16 AWG] 0.14... 1 mm 2 [26... 18 AWG] 0.14... 1 mm 2 [26... 18 AWG] 0.25... 1.0 mm 2 [24... 18 AWG] 0.25... 0.5 mm 2 [24... 20 AWG] 2 conductors (same cross-section) 2 rigid conductors 2 flexible conductors 2 flexible conductors with cable end: without an insulating inlet taper with an insulating inlet taper 0.2... 1.0 mm 2 [24... 18 AWG] 0.2... 1.0 mm 2 [24... 18 AWG] 0.25... 1.0 mm 2 [24... 18 AWG] 0.5... 1.5 mm 2 [20... 16 AWG) 0.14... 0.5 mm 2 [26... 20 AWG] 0.14... 0.75 mm 2 [26... 20 AWG] 0.25... 0.34 mm 2 [24... 22 AWG] 0.5 mm 2 [20 AWG] Connectors 2 pins 3 pins Pitch 5.08 mm [0.20 in.] 3.81 mm [0.15 in.] Tightening torque 4.4 to 5.3 lb-in [0.5 / 0.6 N.m.] 4.4 to 5.3 lb-in [0.5 / 0.6 N.m.] Flat screwdriver 3.5 mm [0.14 in.] 2.5 mm [0.10 in.] 16 1639093 03/2009

Hardware Implementation Technical Characteristics Technical Characteristics Module certification ASI Protection class Complying with IEC 539 IP20 Immunity to fast transients Complying with IEC 1000-4-4 / EN 610004-4 level 4 2kV AS-i power supply 26.5V - 31.6V Current consumed On the AS-i bus 25mA in normal operation. 30mA in fault. Auxiliary power supply 24V DC +/- 30% Current consumed On the 24V auxiliary Depends on the load connected to the outputs. Limited to 500mA Relay output rating Short-circuit and overload protected 0.5A / 24V 1639093 03/2009 17

Hardware Implementation 18 1639093 03/2009

Software Implementation 1639093 03/2009 Software Implementation 2 Overview Hardware implementation of an ASILUFC5 / ASILUFC51 AS-i communication module is being followed by its software implementation. What's in this Chapter? This chapter contains the following topics: Topic Page Configuration Software 20 Addressing 21 Description of the I/O Variables on the ASILUFC5/ASILUFC51 Module 22 Managing Faults 23 1639093 03/2009 19

Software Implementation Configuration Software AS-i Comm. Module and PL7 Software The AS-i communication module is configured with the PL7 Micro/Junior/Pro software. All the slave equipment corresponding to all the inputs/outputs of the AS-i bus can be configured from the PLC interface declaration screen. Used with the Master PLC interface TSXSAY 1000 and to retain interchangeability compatibility with the motor starters in box LF1/LF2. The 7.D.F.0 motor start profile limits the configuration to 31 slave devices as a maximum. In fact, an ASILUFC5 / ASILUFC51 module occupies the 2 addresses of banks A and B. The 7.A.7.E motor start profile limits the configuration to 62 slave devices as a maximum. The ASILUFC5 configuration is guided by the screen sequence. The following is a configuration example with the Premium TSXSAY 1000 PLC interface. Configuration Example (Steps 1-2) Configuration example: step 1 Configuration example: step 2 20 1639093 03/2009

Software Implementation Addressing Description of Addressing Here is a view of the links with an addressing terminal, which can be of two differents types: referenced as ASITERV2, referenced as XZMC11. 1639093 03/2009 21

Software Implementation Description of the I/O Variables on the ASILUFC5/ASILUFC51 Module AS-i Profiles The following table describes the input and output variables associated to the AS-i profiles: AS-i Profiles: 7.D.F.0 (for ASILUFC5) or 7.A.7.E (for ASILUFC51) Current consumed on the AS-i bus 15mA typical Bit value = 0 = 1 Data bits (commands) D0 Stop direct direction Run forward direction (Outputs) D1 Stop reverse direction Run reverse direction D2 Reserved Reserved D3 Reserved Reserved Data bits (status) D0 Not ready or in fault Ready (Inputs) D1 Stopped Running D2 Reserved Reserved D3 Reserved Reserved If D0 and D1 output bits are set to 1 at the same time, the motor stops. NOTE: The parameter bits are reserved. Schematic diagram The ON, OFF, TRIP and power contact states are transmitted via a mechanical link. 22 1639093 03/2009

Software Implementation Managing Faults Description of the Faults Fault Causes Corrective actions Green "Power" LED Off No AS-i bus voltage Check the state of the AS-i power supply Check the cables and the connecting terminals Check the polarity of the power supply wire Red "Fault" LED flashing No 24V DC auxiliary voltage Check the state of the auxiliary power supply Check the cables and connection terminals Check the polarity of the power supply wire Motor feed engaged in the "TRIP" position Remove the cause of the fault Rearm the product Red "Fault" LED permanently On No exchange with the Master (Communication fault on AS-i bus) Addressing fault (Address factory-set to 0) Check the connection to the Master Check if the Master is set to Run Check if the 24V AS-i and 24V DC auxiliary connections are not reversed Set an address from 1 to 31 (ASILUFC5) or 1 to 62 (ASILUFC51) 1639093 03/2009 23

Software Implementation 24 1639093 03/2009