Installation Guide Versatile Access Power and Integration Enclosures

Similar documents
Installation Guide. Versatile Access Power and Integration Enclosures. Trove2M2 - Trove2 enclosure with Altronix/Mercury backplane

Access & Power Integration Solutions

Expandable Power Systems

DC Outdoor Power Supply/Chargers


3-Port Ethernet over Fiber PoE+ Hardened Switches Installation Guide

8-Port Ethernet over Fiber PoE Hardened Switches Installation Manual

4-Port Ethernet over Fiber PoE+ Hardened Switches Installation Guide

AL168 Series Multi-Output Power Supplies

Active UTP Transceiver Hub with Integral Isolated Camera Power

Enclosures AE1/AE3. Installation Guide

NetWay1DWP - Outdoor Single Port Hi-PoE Injector NetWay1DWPM - Outdoor Managed Single Hi-PoE Injector I.T.E. 43KC

long range ethernet Extend Ethernet range 5x the distance - without repeaters. Long Range Ethernet Adapters Features:

Rack Mount Power Supplies

Passive UTP Transceiver Hub with Integral Camera Power Installation Guide

Transceiver Hub with Integral Camera Power

Active UTP Transceiver Hub with Integral Camera Power Installation Guide

Passive UTP Transceiver Hub with Integral Isolated Camera Power Installation Guide

Active UTP Transceiver Hub with Integral Camera Power Installation Guide

Passive UTP Transceiver Hub Installation Guide

Installation and User Guide

ebridge200b - Managed Two Port Transceiver Board

Active UTP Transceiver Hub with Integral Isolated Camera Power Installation Guide

User s Guide. Includes Mounting, Installation, and Product Registration nd Avenue NE Arlington, WA USA (+1)

Instructions to Install Retrofit Kit RVMC 4/5000 Machine (MDB Only)

Universal Desktop and Monitor Stand

USBCNC-SW USB Disk Key reader for CNC Controls Machine Mount instructions for Universal Switcher Version

INSTALLATION INSTRUCTIONS

Installation Guide. Rev

Vertiv VR Rack 1.0 GENERAL

EWS660AP. Quick Installation Guide

INSTRUCTIONS FOR THE INSTALLATION OF THE INFINITY "L" DISPLAY HOOD (INTO PREVIOUSLY INSTALLED INFINITY "L" SYSTEMS)

New IP & Power Solutions. for 2018

7403 K321. Display Wall Mount. Kit Instructions. Issue A

ATTENTION: OBSERVE PRECAUTIONS FOR HANDLING ESD-SENSITIVE DEVICES

AM-516. Adaptor Ring. User s Manual. Complies with FD8162 fixed dome camera. Rev IP Surveillance

Assembly Instructions for #5630 Medication PalWOW

BL-FLOWSTN-P FlowStation Module Installation Guide

Firebox X Edge e-series De-Manufacturing Instructions

Installing a Power over Ethernet injector

Network Power Distribution Module

INSTRUCTION BULLETIN

USBCNC USB Disk Key reader for CNC Controls Machine Mount instructions

HomeWorks Remote Power Feed-Through Panels

IS-DM220/IR/HB IS-DM220

modular enclosure MUREVA, IP65 weatherproof & versatile enclosures aesthetics multi-functional evolutionary ergonomics and time saving security

PoE Managed Midspan Solution for Standard Network Infrastructure

Terminal Equipment Controller Enclosure

TruPortal Dual Door Interface Module Quick Reference

Installation Notes TII Model 341 Protector

Phase Loss Protection Upgrade. Phase Loss Protection Upgrade. In this bulletin:

TDM To MiniMech conversion ProceDure

TELEPHONE FLUSH WALL PLATE

ASSEMBLY AND ADJUSTMENT

How to Design Custom Enclosures for Motherboard-Based Systems

TensionLitePlus Kiosk Design 4

SITRANS F. Flowmeters SysCom Upgrade Kit IP65 (NEMA 4X) Multi-Channel. Introduction 1. Installing/Mounting 2. Hardware Installation Instructions

Models 120LS, 200LS, 300LS, 400LS, 560LS Installation Instructions

Ethernet/Network Communications Module. Installation and Programming Manual. LINQ2 - Two (2) Port Connectivity Module. More than just power.

15P0097Q1 SINUS K - PENTA REMOTE MOUNTING THE KEYPAD MOUNTING GUIDE

Portable Staging User Guide

Probably the fastest enclosure in the world

PACSystems* RX3i IC695ACC650

TruPortal Output Expansion Board Quick Reference

HAW-SIBU. Rack Installation Guide. Version 1.0.1

INSTALLATION INSTRUCTIONS: E KIT-EMV-INGENICO ICMP CRADLE-PAYPOINT E KIT-EMV-VERIFONE E355 CRADLE-PAYPOINT

DOCKING STATION SPECIFICATIONS

E1135C PDU and Pod Upgrade Procedure

Series Amp Pad Mount Quick Connect Input and Output Power Panels

Formulate Accent - 04

XDBKITS5 Bus / DB Terminal Kit (Size 5) Installation Manual DPD00116

GV-EL124S Electric Strike

Quick Start Guide. SEB-710 I/O Expansion board. Introduction

Eaton LCD Lift Flat Panel Display System. Installation Guide

Assembly Instructions Triton Enclosure for Poseidon With Data Acquisition November, 2007 V0.9 DSC Document #

Series Amp Quick Connect Input and Output Power Panels

PXC Compact Unitary Equipment Controller (UEC)

FLEXBOX. Installation Guide

In-ceiling Housing. Installation Manual SHP-3701F

TECHKNOW, INC. Kiosk Order Confirmation System INSTALLATION MANUAL. Revision Date: July 11, 2012 Part # Version 3.2

EP/2 Installation Instructions

ATTENTION: OBSERVE PRECAUTIONS FOR HANDLING ESD-SENSITIVE DEVICES

INSTALLATION INSTRUCTIONS

PowerLogic High Density Metering System 1-Meter Enclosure

Wireless Key fob, Key pad & Receiver Range

TSMIU Wireless Bridge Installation and Configuration

Kit K Instructions. V8700 to Alpha Conversion Instructions

ATTENTION: OBSERVE PRECAUTIONS FOR HANDLING ESD-SENSITIVE DEVICES

7" Touch Screen Display

Warning Before Installation. Package Contents EN-1. Power off the Network Camera as soon as smoke or unusual odors are detected.

To Purchase This Item, Visit BMI Gaming (800)

Thanks for shopping with Improvements! Chalet Standard Mailbox Item # (With 1 Line Plaque) Item # (With 2 Line Plaque)

PCLASS Integrated Paxton Access Power

Part Name/Description Part Number Quantity

Tyler - Middle Mount For Bell 407, 206 & 206L Series Helicopters FAA STC # SH3246NM

Please read thoroughly before starting installation and check that kit contents are complete.

FortiCam FD40 Mounting Guide

Portable Staging User Guide

Use flat head screws for the out side of chassis and pan head screw for inside of chassis.

Ultima X5000 Rectangular Duct Mount Kit User Instructions

Transcription:

Rev. 053116 Installation Guide Versatile Access Power and Integration Enclosures Trove1C1 Trove2CV2 - Trove1 enclosure with - Trove2 enclosure with /CDVI backplane (TC1) /CDVI backplane (TCV2) TC1 TCV2 - /CDVI backplane only - /CDVI backplane only Overview: Trove1C1 and Trove2CV2 accommodate various combinations of CDVI boards with or without power supplies and accessories for access systems. Specifications: 19 Gauge grey enclosure with ample knockouts for convenient access. Trove1C1 - Trove1 enclosure with TC1 /CDVI backplane. Includes: tamper switch, cam lock, lock nuts and mounting hardware. Enclosure Dimensions (H x W x D): 18 x 14.5 x 4.6255 (457mm x 368mm x 118mm) TC1 - TC1 /CDVI backplane. 19 Gauge backplane. Includes mounting hardware. Dimensions (H x W x D): 16.625 x 12.5 x 0.3125 (422.275mm x 317.5mm x 7.9mm) TC1 Backplane accommodates a combination of the following: One (1) AL400ULXB2, AL600ULXB, AL1012ULXB, AL1024ULXB2, eflow4nb, eflow6nb, eflow102nb or eflow104nb. One (1) ACM4(CB), MOM5, PD4UL(CB), PD8UL(CB), PDS8(CB), VR6. Four (4) A22 modules. Trove2CV2 - Trove2 enclosure with TCV2 /CDVI backplane. Includes: tamper switch, cam lock, lock nuts and mounting hardware. Enclosure Dimensions (H x W x D): 27.25 x 21.75 x 6.5 (692.15mm x 552.45mm x 165.1mm) TCV2 - TCV2 /CDVI backplane. 19 Gauge backplane. Includes mounting hardware. Dimensions (H x W x D): 25.375 x 19.375 x 0.3125 (644.525mm x 492.125mm x 7.9mm) TCV2 Backplane accommodates a combination of the following: Two (2) AL400ULXB2, AL600ULXB, AL1012ULXB, AL1024ULXB2, eflow4nb, eflow6nb, eflow102nb or eflow104nb. One (1) ACM8(CB), or two (2) MOM5, PD4UL(CB), PD8UL(CB), PDS8(CB), VR6. Five (5) A22 modules. Trove1C1/TC1/Trove2CV2/TCV2 - /CDVI - 1 -

Installation Instructions: Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having jurisdiction. Product is intended for indoor use only. 1. Remove backplane from enclosure. Do not discard hardware. 2. Trove1C1 (Fig. 5, pg. 5) Mark and predrill holes on the wall to line up with the top two keyholes in the enclosure. Install two upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure s upper keyholes over the two upper screws, level and secure. Mark the position of the lower two holes. Remove the enclosure. Drill the lower holes and install the two fasteners. Place the enclosure s upper keyholes over the two upper screws. Install the two lower screws and make sure to tighten all screws. Trove2CV2 (Fig. 9, pg. 8) Mark and predrill holes on the wall to line up with the top three keyholes in the enclosure. Install three upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure s upper keyholes over the three upper screws, level and secure. Mark the position of the lower three holes. Remove the enclosure. Drill the lower holes and install the three fasteners. Place the enclosure s upper keyholes over the three upper screws. Install the three lower screws and make sure to tighten all screws. 3. Mount UL Listed tamper switch (Included) (Ademco model 112 or equivalent) in desired location, opposite hinge. Slide the tamper switch bracket onto the edge of the enclosure approximately 2 from the right side (Fig. 1, pg. 1). Connect tamper switch wiring to the Access Control Panel input or the appropriate UL Listed reporting device. To activate alarm signal open the door of the enclosure. 4. Mount /CDVI modules to TC1 or TCV2 backplane, refer to pages 3 and 6. Mounting Hardware: Plastic Standoff Metal Standoff 3/8 Pan Head Screw Honeywell model # 112 Tamper Switch or equivalent (provided) Enclosure to Access Control Panel or U.L. Listed Reporting Device Fig. 1 Edge of Enclosure - 2 - Trove1C1/TC1/Trove2CV2/TCV2 - /CDVI

TC1: Configuration of Power Supply and/or Sub-Assembly Boards and CDVI Modules 1. Fasten standoffs (provided) to pems that match the hole pattern for Power Supply/Chargers or Sub-Assembly boards (Fig. 3, pg. 3). Fasten metal standoffs in the correct locations to provide proper grounding, see below (Fig. 3, pg. 3). 2. Mount boards to standoffs utilizing 5/16 pan head screws (provided) (Fig. 3, pg. 3). 3. Mount appropriate CDVI A22 modules into the correct positions (Fig. 3, pg. 3). by postioning standoffs over appropriate holes on the backplane and depress down on board to secure standoff to the backplane (Fig. 2, pg. 3). Note: CDVI A22 modules have one (1) RJ45 jack each. Please make sure that they are mounted correctly, as shown in Fig. 3 below. 4. Fasten TC1 backplane to Trove1 enclosure utilizing pan head screws (provided). Fig. 3 - Trove1C1/TC1 Configurations Plastic Stand Off pre-mounted into CDVI Atrium modules Insert into TC1/TCV2 backplane Fig. 2 Metal Standoff Placement Power Supply Sub- Assembly Trove1C1/TC1/Trove2CV2/TCV2 - /CDVI - 3 -

Fig. 4 TC1 Dimensions 0.5 (12.7mm) 12.5 (321.31mm) 8.15 (207.01mm) 16.65 (422.9mm) 15.65 (397.5mm) 6.25 (158.75mm) 0.5 (12.7mm) - 4 - Trove1C1/TC1/Trove2CV2/TCV2 - /CDVI

Fig. 5 Trove1C1 Enclosure Dimensions (H x W x D): 18 x 14.5 x 4.6255 (457mm x 368mm x 118mm) 7.25 (184.15mm) 14.5 (321.31mm) 1.45 (36.83mm) 1.948 (49.483mm) 4.5 (114.3mm) 13.0 (330.2mm) 1.5 (38.09mm) 0.5897 (14.98mm) 1.5 (38.09mm) 0.569 (14.52mm) 8.5 (215.9mm) 8.5 (215.9mm) 18.0 (457.2mm) 6.5 (165.1mm) 6.5 (165.1mm) 0.6012 (15.27mm) 1.0958 (27.83mm) 4.5 (114.3mm) 4.5 (114.3mm) 2.75 (69.85mm) 1.115 (28.32mm) 1.362 (34.59mm) Trove1C1/TC1/Trove2CV2/TCV2 - /CDVI - 5 -

TCV2: Configuration of Power Supply and/or Sub-Assembly Boards and CDVI Modules 1. Fasten standoffs (provided) to pems that match the hole pattern for Power Supply/Chargers or Sub-Assembly boards (Fig. 7, pg. 6). Fasten metal standoffs in the correct locations to provide proper grounding, see below (Fig. 7, pg. 6). Note: sub-assembly position can accommodate either one (1) ACM8/ ACM8CB or two (2) PD4UL/PD4ULCB, PD8UL/PD8ULCB or MOM5. 2. Mount boards to standoffs utilizing 5/16 pan head screws (provided) (Fig. 7, pg. 6). 3. Mount appropriate CDVI A22 modules into the correct positions (Fig. 7, pg. 6). by postioning standoffs over appropriate holes on the backplane and depress down on board to secure standoff to the backplane (Fig. 6, pg. 6). Note: CDVI A22 modules have one (1) RJ45 jack each. Please make sure that they are mounted correctly, as shown in Fig. 7 below. 4. Fasten TCV2 backplane to Trove2 enclosure utilizing pan head screws (provided). Fig. 7 Plastic Stand Off pre-mounted into CDVI Atrium modules Insert into TC1/TCV2 backplane Fig. 6 Power Supply Metal Standoff Placement Power Supply or Sub-Assembly Metal Standoff Placement Sub-Assembly - 6 - Trove1C1/TC1/Trove2CV2/TCV2 - /CDVI

Fig. 8 7.5 (190.5mm) TCV2 Dimensions 19.4 (492.76mm) 7.5 (190.5mm) 24.95 (633.73mm) 0.156 ( 3.96mm) 25.4 (645.16mm) 12.62 (320.55mm) 12.62 (320.55mm) 8.495 (215.77mm) 16.245 (412.62mm) 1.0 (25.4mm) 0.45 (11.43mm) 7.5 (190.5mm) 1.0 (25.4mm) 7.5 (190.5mm) 9.2 Trove1C1/TC1/Trove2CV2/TCV2 - /CDVI - 7 -

Fig. 9 Trove2CV2 Enclosure Dimensions (H x W x D): 27.25 x 21.75 x 6.5 (692.15mm x 552.45mm x 165.1mm) 5.25 (133.35mm) 3.50 (88.9mm) 21.50 (546.1mm) 3.50 (88.9mm) 5.25 (133.35mm) 0.5625 (14.29mm) 2.415 (61.34mm) 1.77 (44.96mm) 0.685 (17.399mm) Knockouts 1.125 (28.32mm) 0.885 (22.479mm) 6.25 (158.75mm) 6.25 (158.75mm) 0.85 (21.59mm) 1.5 (38.1mm) 19.80 (502.92mm) 6.75 (171.45mm) G 27.00 (685.8mm) 8.25 (209.54mm) 8.00 (203.2mm) 0.85 (21.59mm) 1.00 (25.4mm) 5.25 (133.35mm) 7.00 (177.79mm) 5.25 (133.35mm) is not responsible for any typographical errors. Product specifications are subject to change without notice. 140 58th Street, Brooklyn New York 11220 USA, 718-567-8181, fax: 718-567-9056 website: www.altronix.com, e-mail: info@altronix.com. Made in USA. IITrove1C1/Trove2CV2 - Rev. 05312016 F22P MEMBER - 8 - Trove1C1/TC1/Trove2CV2/TCV2 - /CDVI