Total Home Surge Protection for Point-of-Entry. FirstSurge TM. User Manual - Canada (English)

Similar documents
Surge Protective Devices. Installation & Operation Manual. Model 335

User Manual - Canada. TPS3 03 DC For DC Photovoltaic Applications. Surge Protective Device

TPS3 09. Surge Protective Device. User Manual - USA

R-LB R-LX Series Installation, Operation & Maintenance Manual

Surge Protective Devices. Installation & Operation Manual. Model 420

TPS3 11. Surge Protective Device. User Manual - USA

Surge Protective Devices. Installation & Operation Manual. Model 425

TWL Series Installation Guide

Total Protection Solutions Surge Protective Devices SurgeTrack Series: 080, 120, 160, 240, 300 and 400

INSTALLATION INSTRUCTIONS STZ-R SERIES (ENGLISH)

Specifications, Installation, and Operating Instructions

Specifications 1 Installation Procedures 2 Wiring Diagrams 3 Installation Checklist 5 Maintenance 5 Warranty Information 6 Material Return Policy 6

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL

HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD)

Liebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

Instruction Manual IM E Table of Contents

Surge Protective Devices Installation, Operation and Maintenance Manual. ServiceTrack ST Series: 080, 120, 160, 200, 240, 300 and 400

Installation and Operation Manual

Eaton Innovative TechnologyT XT50/100 surge protective device

GE Digital Energy. Power Quality

Always "On" UPS Systems Inc. USER MANUAL

DANGER DANGER: is used in this manual to warn of high voltages capable of causing shock, burns, or death.

Surge Protective Devices. Installation & Operation Manual. Model 457

INSTALLATION, OPERATION AND MAINTENANCE MANUAL GE TRANQUELL Series Wall Mounted Low and Medium Exposure Surge Protective Devices (SPDs)

Models 120LS, 200LS, 300LS, 400LS, 560LS Installation Instructions

SECTION SURGE PROTECTION DEVICES. A. Section includes Surge Protection Devices for low-voltage power, control, and communication equipment.

Eaton SPD Series. Instruction Manual IM E Effective June 2014 Rev. 2

Eaton SPD Series. for Mounting External to Electrical Distribution Equipment. Instruction Manual IM E Effective March 2014 Rev.

Instruction Manual: IM E

1. Section Lightning Protection for lightning protection system. D. The installation shall be in conformance with NEC Article 285.

Instruction / Installation Sheet DataComm Electronics WH Recessed Pro-Power Kit with Duplex Receptacle and Straight Blade Inlet

Surge Protection Devices (SPD)

Eaton s Innovative Technology Surge Suppression Guideform Specification High Exposure DIVISION 16 SECTION 16289

Eaton s Innovative Technology Surge Suppression Guideform Specification Low Exposure DIVISION 16 SECTION 16289

DIVISION 16 SECTION Surge Protective Device Submittal (SPD)

Installation and Operation Manual

Hubbell Surge Protective DeviceS

PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL

for the SPV Installation and Operation Manual Instruction Manual IM E Contents

The following standards are the basis of design, manufacture, and test of SPD equipment: Guide for Surge Voltages in Low-Voltage AC Power Circuits

Installation, Operation, and Service Manual SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET

Surge Protective Devices. STV100K Series. Instruction Manual

Progressive Industries, Inc. EMS Electrical Management System

Surge Protective Devices. STV100K Series. Instruction Manual

TPS3 Internal Manual. Surge Protective Device. User Manual - Canada

SECTION TRANSIENT VOLTAGE SUPPRESSION FOR LOW-VOLTAGE ELECTRICAL POWER CIRCUITS

Installation Instructions & User Manual

Surge Protective Devices (SPD)

SURGE PROTECTION USER MANUAL. Surge Protection Device PORTABLE POWER DISTRIBUTION SURGE PROTECTION DEVICE (SPD) B

EMS Electrical Management System

Breaker Panel Technical Practice NPDRP1114

Zonit μats TM Users Guide μats1-lv Version 1.2

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data:

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2

Installation and Operation Guide for PD5200 and PD5300 Automatic Transfer Switch

Broadband Automatic Disconnect Switch. User Manual

Digital Lighting Systems, Inc. PD216. Two Channel Dimmer and Switch Packs PROTOCOL USER'S MANUAL. PD216-UM Rev. E - 02/03

Westell. Breaker Panel Technical Practice NPDRP1114

Powerware TVSS (Transient Voltage Surge Suppression) ZoneMaster, ZoneSentinel, ZoneDefender

PDI Modular Compact Remote Power Panel

Wise HP33 THREE PHASE HIGH PRECISION AVR SURVO-MOTOR AUTOMATIC VOLTAGE STABILIZER

SAVE THESE INSTRUCTIONS

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE

SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET

Installation Manual. APEX Series. Silicon and MOV Panel Protection. APEX Series

THE SURGE PROTECTION SOLUTION

Microframe Corporation

Series Amp Pad Mount Quick Connect Input and Output Power Panels

INSTALLATION AND MOUNTING MANUAL

TransGuard. Electrical Transient Suppression Filter Systems. Installation, Operation and Maintenance Manual PN ,

EMS Electrical Management System

Installation Instructions & User Manual POWERWARE TVSS ZONESENTINEL. AC Panel Transient Voltage Surge Suppressors

SSMx24 Series 240 ka Per Phase Peak Surge Current ANSI/UL1449 UL Fourth Edition

B. System Design and Performance Requirements

UL th Edition SPD. TPS3 Internal SPDs. User Manual - USA. usa.siemens.com/spd

Model 450 Model 451 Model 452 Model 453 Model 460 Model 465 Model 480 Model 485. Surge Protective Devices. Installation & Operation Manual

400 Series 460 Surge Protective Device Installation, Operation and Maintenance Manual

User s Guide. POWERVAR Single Phase Power Conditioners

GE TR7000 Series Wall Mounted Surge Protective Device (SPD)

M215 (M215-60) Safety

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

SECTION TRANSIENT VOLTAGE SURGE SUPPRESSION

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

PGM-8325 MANUAL NEUTRAL GROUNDING MONITOR

MAXIMA + Series ROTARY LEVEL CONTROL

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

PGR-4300 MANUAL GENERATOR GROUND-FAULT RELAY

Catalog Number Identification with Elements Explained V V V V X 347 V Hz

Installation. MGE Galaxy 3500 and Smart-UPS VT. Maintenance Bypass, Distribution and Transformer Cabinet

Secondary Surge Arrester Instruction Manual Page 1 of 5

EMS. Electrical Management System. Progressive Industries Incorporated Morrisville, North Carolina

Series Amp Quick Connect Input and Output Power Panels

PV Rapid Shutdown device

MasterMind. MasterMind. Diagnostic Monitoring System For Select and TransGuard Suppression Filter Systems

BSPD Surge Protective Devices

MFJ ENTERPRISES, INC.

MAXIMA + Series ROTARY LEVEL CONTROL

Models beginning with 2M, 2L or 2X. Product Description. Technical Specifications. Installation Instructions. Series 2000 Multiple Meter Units (MMUs)

Enphase S-Series Microinverter and Engage Cable Safety

Transcription:

Total Home Surge Protection for Point-of-Entry FirstSurge TM User Manual - Canada (English) www.siemens.ca/surge

Introduction Thank you for choosing the Siemens FirstSurge Residential Surge Protective Device. Save this manual! It includes instructions for obtaining warranty service and for returning a defective device. Please read and understand all information in this manual prior to installation. The procedures contained herein are not intended to supersede local or national electrical codes. Check all applicable electrical codes to ensure compliance. In all instances, local and national electrical code requirements are to be followed. This manual provides instructions for installing the FirstSurge Surge Protective Device (SPD). The FirstSurge SPD can be mounted three ways. The preferred way is to mount the SPD directly to the outside of the electrical panel equipment using the chase nipple on the body of the SPD. It can also be installed against a panel/wall using installer supplied hardware, or it can be installed using an optional Flush Mount Kit. The latter two methods require use of additional conduit and hardware (not provided). The FirstSurge provides protection from damaging transient voltage surges and spikes. Proper installation is imperative to maximize the effectiveness and overall performance of this device. This device must be installed by a licensed electrician. The electrician should follow the steps outlined in this manual to insure proper installation. Note: Siemens products are extensively tested to industry standards as set by ANSI/IEEE C62.41.1-2002, C62.41.2-2002 and C62.45-2002. FirstSurge is listed to the most recent edition of UL 1449. This product is suitable for installation on electrical distribution equipment capable of delivering not more than 100,000 rms symmetrical amperes. During installation into an electrical system, the FirstSurge must NOT be energized until the electrical system is installed, inspected and tested. All conductors must be connected and functional. Failure to follow the guidelines in this manual can lead to abnormally high voltage being applied to the SPD. This may cause the FirstSurge unit to become inoperative. The warranty does not cover an incorrectly installed device. Do not high potential test the electrical system with the SPD connected. Failure to disconnect the SPD during elevated voltage testing will result in damage to the suppression components and/or other electronic components (see Safety Information). Parts List and Inspection Items included in the package consist of the following: 1 FirstSurge Surge Protective Device Data Sheet 1 User s Manual (this document) If the Flush Mount Kit (Part #XMFMKIT) was ordered, additional parts are supplied as follows: 1 Flush Mount Plate 4 Pan-head Screws See Figure 3 for installation Carefully inspect each item in the package for signs of damage. If damage is found, please contact Siemens Technical Support:. For more information about this product or other Siemens products, visit www.siemens.ca/surge.

Safety Information Operation This section provides pertinent safety information that must be considered before installing the SPD. Do not install this device during a lightning storm. This device is rated NEMA 4X. Suitable for indoor and outdoor applications. The customer must seal the conduit nipple against the panel using watertight fittings (not supplied) to ensure a watertight connection. Do not install the surge protector in an excessively hot or moist location. Other safety considerations are listed on the previous page. Siemens FirstSurge Residential surge suppressor normally requires no remedial action. However in the event of a power anomaly or a malfunction, the operational status may change and may require action. The table below outlines the operating conditions of the FirstSurge and any correction action if required. This device features internal circuitry that will disconnect the surge protective component at the end of its useful life. Power will maintain to the load, however the load is now unprotected. Follow the manufacturer s instructions for replacing the device. Light 1 Light 2 Alarm Red Audible Alarm Corrective Action Out Out Out Off Reset Breaker if re-opens Replace Unit Green Green No action Out Green Blinks Sounds Replace Unit Green Out Blinks Sounds Replace Unit Green Green Blinks Sounds Check Neutral to Ground Connection before Replacing Unit Model FirstSurge Voltage Rating & Service Type 120/240V Single Phase Specifications Temperature Operating Temperature Storage Audible Noise Service Clearance Installation Type Wire Length vs. Response Time and Let- Through Voltage Wire Size & Installation Torque Circuit Breaker Connection System Grounding -40 C (-40 F) to +60 C (+140 F) -55 C (-65 F) to +65 C (+149 F) None 36 in (94.1 cm) in front of the unit Chase Nipple 1 ft (31.7 cm) of wire = 1 nanosecond. 175 volts per foot (6kV,3kA, 8/20 microseconds) are added to the clamp voltage. Wire Size = #10 AWG, torque to 18 in. lbs. 20 Amp Per IEEE STD 142-1991. For sensitive electronics/computer systems, the recommended ground impedance is 25 ohms or less.

Figure 1: Typical Panel Installation Figure 2: Leads Short & Straight (Type 1 or individual equipment installations may vary) To Protected Loads A BREAKER C Use closest breaker to SPD Locate SPD close to intended breaker Keep Leads Short as Possible Avoid Sharp Bends NOT GOOD Cut off Excess Length Do Not Loop or Coil N G s s Rotate unit such that LED indicator is most visible GOOD Short & Straight Outdoor installation requires appropriate weather sealing at nipple (gasket, sealing conduit, etc.) Installation FirstSurge is a Type 2 SPD. It is suitable for use downstream of the service disconnect. Pre-Plan your installation. You need to accomplish the following: Meet all National and Local codes (NEC Article 285 and UL 1449 address SPDs). Confirm System voltage to SPD voltage (120V SPD will fail instantly on 240V, 277V, etc.). Mount SPD as close to panel or equipment as possible to keep leads short. (long leads hurt performance). Ensure leads are as short and straight as possible, including neutral and ground. Use a breaker position that is close to the SPD and the panel s neutral and ground. Recommended breaker size is 20A. Make sure system is grounded per NEC and clear of faults before energizing SPD. (inadvertent system problem may fail SPD). Never Hi-Pot test Any SPD. (will prematurely fail SPD). 1. Use voltmeter to check voltages and ensure correct SPD. See Data Sheet for specs and wire-outs. 2. Determine Mounting location weather resistant equipment may be required. 3. If SPD has optional Flush Mount Kit, pre-plan its installation. See Figure 3. (If flush mounting, be careful to not drop SPD into wall). 4. Remove power from panel/source. Confirm panel/source is deenergized. 5. Identify breaker location and SPD location. Position SPD such that LEDs are best visible. If Flush Mount Kit was ordered, follow Flush Mount instructions and then proceed at #6. 6. Mount SPD weather resistant applications require additional sealing, etc. (not included) -- Remove an appropriately sized knockout from panel. -- Connect conductors as appropriate short and straight as possible. 7. Label or mark conductors as appropriate (neutral: white, ground: green, energized: black). 8. Make sure system is bonded per NEC and is clear of hazards or faults before energizing (N-G bonding not per NEC will fail SPDs: #1 cause of SPD failures). 9. Energize and confirm proper operation of green LED indicators. If any connected phase LED does not illuminate, remove power, check all connections and test again. If any connected phase LED still does not illuminate, contact Siemens Technical Support at:. 10. The SPD is equipped with an audible alarm which will sound in the event of an alarm condition. This indicates a problem with the SPD which requires further evaluation. There is no test or silence switch. De-energizing the SPD will silence the alarm. CAUTION VERIFY THAT ALL POWER CIRCUITS ARE DEENERGIZED BEFORE MAKING CONNECTIONS All electrical connections should be performed by a qualified (licensed) electrician or technician. All wiring must comply with the National Electrical Code (NEC ) and applicable local codes.

Flush Mount Installation Instructions 1. Select the location where the SPD and Flush Mount Kit (XMFMKIT) will be mounted. Aesthetics may have to be sacrificed in order to achieve maximum surge protection. 2. Place the Flush Mount Kit plate where it will be mounted and trace the center hole and mounting holes. Cut this shape into the mounting surface and mount the XMFMKIT panel to the mounting surface 3. BE CAREFUL TO NOT DROP THE SPD INTO THE WALL. 4. Install the SPD to the back side of the Flush Mount Kit plate using the four 8/32 x 5/8 Thread Cutting Screws provided with the XMFMKIT kit. 5. Proceed with #6 on page 3. Figure 3: Typical FirstSurge SPD installation s s NOTICE CONDUCTING DIELECTRIC AND/OR HIGH POTENTIAL TESTING WILL CAUSE INTERNAL DAMAGE TO THE SPD UNIT. DO NOT PERFORM DIELECTRIC OR HIGH POTENTIAL TESTS WITH THE PHASE OR NEUTRAL SPD WIRES CONNECTED.

Figure 4: Dimensions & Weight 8.28 (210.31) 7.41 (188.21) s 2.21 (56.13) 3.67 (93.22) s 3.00 (76.20) 0.19 (4.83) Troubleshooting & Service Please contact us for any service related issues. We want to take care of any problems. Quality SPDs withstand severe duty and attempt to protect their load until failure. There are electrical anomalies that SPDs cannot protect against. These are generally Sustained Overvoltages also known as Temporary Overvoltages (TOVs). In this context, Sustained Overvoltages may be only a few cycles. Failed SPDs tend to be symptoms, not root causes. As a generalization, the single largest killer of SPDs is reference to ground issues. If the SPD shows problems on startup, there is reasonable chance of bonding/grounding/misapplication issue. This permanently damages the unit. If not corrected, it will happen again. Any returns need a Return Authorization (RA) number. Warranty & Service LIMITED WARRANTY Siemens warrants it s AC electrical distribution equipment protection products against defective workmanship and materials for 10 years. Liability is limited to the replacement of the defective product. A Return Material Authorization number (RMA #) must be given by the company prior to the return of any product. Returned products must be sent to the factory with the transportation charges prepaid. The company specifically disclaims all other warranties, expressed or implied. Additionally, the company will not be responsible for incidental or consequential damages resulting from any defect in any product or component thereof. Siemens Technical Support & Customer Service info@purgethesurge.com This manual as well as information about the entire Siemens product line are available on the Internet at: www.siemens.ca/surge. Prior to calling Siemens for technical support, please have the following information available: Model Number of unit: Manufacture Date: Purchase Date: Your Order Number: Return Shipment Address: Siemens 14550 58th Street North Clearwater, FL 33760 Attn: RMA#

Siemens Canada Limited 1577 North Service Road East Oakville, ON L6H 0H6 Canada 888-333-3545 info@purgethesurge.com Order No. EM-LP-1414 Printed in USA 2015, Siemens Industry, Inc. European Authorized Representative Obelis s.a. Boulevard Général Wahis 53 1030 Brussels, BELGIUM Tel: +(32) 2. 732.59.54 Fax: +(32) 2. 732.60.03 E-Mail: mail@obelis.net www.siemens.ca/surge 6.16.15.lh #9036