Tube & Pipe styles disappear

Similar documents
Dreamweaver 101. Here s the desktop icon for Dreamweaver CS5: Click it open. From the top menu options, choose Site and New Site

Title and Modify Page Properties

Best Practices for Loading Autodesk Inventor Data into Autodesk Vault

IBM TRIRIGA Application Platform Version 3 Release 4.2. Object Migration User Guide

IM10025 Inventor Flexible Tube and Pipe: How to be a Hoser

Sharing and Copying Inventor Parameters

Allowing access to Outlook 2000 folders Version 1.00

How to make a Work Profile for Windows 10

EDITING AN EXISTING REPORT

Gatekeeper. The Navigation Window. Copyright 2005, Primary Solutions, Inc.

Files and Folders What are Files and Folders Files: This is the Data, Images, and things the user makes

Lesson 4: Who Goes There?

Title and Modify Page Properties

RISKMAN REFERENCE GUIDE TO FEEDBACK MANAGEMENT

Subversion was not there a minute ago. Then I went through a couple of menus and eventually it showed up. Why is it there sometimes and sometimes not?

e-storage Mail Archive e-storage Mai Archive

Installing a Custom AutoCAD Toolbar (CUI interface)

Computer Essentials Session 1 Step-by-Step Guide

Table of Contents. 3. Changing your Lotus Notes Password, page Choosing your Letterhead and Signature, page 6

FmPro Migrator Developer Edition - Table Consolidation Procedure

Inventor Vault Environment

Lab - Configure Data Backup and Recovery in Windows 7 and Vista

Keep Track of Your Passwords Easily

MAPLOGIC CORPORATION. GIS Software Solutions. Getting Started. With MapLogic Layout Manager

QSalesData User Guide

Introduction to Autodesk VaultChapter1:

SwanSim - A Guide to Git / SourceTree / GitLab for Windows

Using the Customize Dialog Box

Computer Basics: Step-by-Step Guide (Session 2)

Microsoft Expression Web is usually obtained as a program within Microsoft Expression Studio. This tutorial deals specifically with Versions 3 and 4,

WebMatrix: Why PHP Developers Should Pay Attention

Workspace Administrator Help File

How to Archive s in Outlook 2007

Working with Neutral Format Surface and Solid Models in Autodesk Inventor

Using the Link to Petrel

Word: Print Address Labels Using Mail Merge

Review and Evaluation with ScreenCorder 4

RISKMAN REFERENCE GUIDE TO FEEDBACK MANAGEMENT

Rescuing Lost Files from CDs and DVDs

Microsoft Office SharePoint. Reference Guide for Contributors

Switched-On Schoolhouse 2014 User Guide Reports & Application Functions

Getting Started Guide

General Guidelines: SAS Analyst

Outlook Web Access. In the next step, enter your address and password to gain access to your Outlook Web Access account.

TUTORIAL No 1: Page Setup

Bucknell University Digital Collections. LUNA Insight User Guide February 2006

SECTION 5 USING STUDENT

SAP BusinessObjects Live Office User Guide SAP BusinessObjects Business Intelligence platform 4.1 Support Package 2

You will always have access to the training area if you want to experiment or repeat this tutorial.

IP4 - Running reports

Lab 1: Adding a Rhapsody Model to RMM

Targeted Content Channel Creation Tutorial

Managing a complete site over multiple AutoCAD Plant 3D Projects

Working with Encrypted Data. In ODK Aggregate

Remodeling Your Office A New Look for the SAS Add-In for Microsoft Office

Grapher 10 Ribbon Bar

Introduction to Windows

Dreamweaver is a full-featured Web application

System Manager 7 Quick Guide (SIMS.net onwards)

Dreamweaver is a full-featured Web application

AXIBATCH Backing Up Procedure 9/6/2012 BACKUP PROCEDURES AXIBATCH SYSTEMS. Developed By. Control Systems

UNIVERSITY OF WOLLONGONG MICROSOFT OUTLOOK

Microsoft Office 365 Word Online

Function. Description

Clean & Speed Up Windows with AWO

CAPITAL (Collection of Astronomy and Physics Images for Teaching And Learning)

ACA 1095 Reporting - File Manager Overview. File Manager

Chapter A2: BankLink Books clients

User Manual - Tick Tool. anage

XP: Backup Your Important Files for Safety

How to set up an Amazon Work Profile for Windows 8

2. Sign the document with either your finger or a stylus. 3. Save and the signed PDF document to the desired party.

Using SupportDesk. House-on-the-Hill Software Ltd. SupportDesk Green

Folios & Web Pages. 71 WEST 23RD STREET, NEW YORK, NY T e

SharePoint SITE OWNER TRAINING

Getting Started. Chapter

Content Module. ActiveModeler Avantage. Managing Enterprise Documentation. Version 1.2, 6 May KAISHA-Tec What does the Content Module do?

SAMLab Tip Sheet #5 Creating Graphs

Laboratory Assignment #3 Eclipse CDT

HMDA LAR Submission. HMDA LAR Submission 2015

ME Week 3 Project 3 - Plastic Part Thicken Method

Course Exercises for the Content Management System. Grazyna Whalley, Laurence Cornford June 2014 AP-CMS2.0. University of Sheffield

OUTLOOK ATTACHMENT EXTRACTOR 3

PageCounter Professional RMA

Version 9. Backing Up and Restoring Progeny 9 Databases

We will now go through these steps in more detail before beginning the actual import exercises.

1 Exporting Files from Maestro Easy Dental Scan Great Lakes Orthodontics

Windows Me Navigating

Synchronizing your Psion with Lotus Organizer

TRIM Document Queue Instructions

If the workshop is being performed on a laptop provided by Nordcad there is no need to install the workshop files.

Rediscover Charts IN THIS CHAPTER NOTE. Inserting Excel Charts into PowerPoint. Getting Inside a Chart. Understanding Chart Layouts

LSSP Corporation 1 PinPoint Document Management Initial Setup Guide - Advanced

Math Dr. Miller - Constructing in Sketchpad (tm) - Due via by Friday, Mar. 18, 2016

Design Flow Highlights

CNC Transfer. Operating Manual

EPT 331 Advanced Manufacturing Technology LAB 2: CAM MILLING (Catia) 2008/2009 LAB 2: CAM MILLING

Creating Pages with the CivicPlus System

MAPLOGIC CORPORATION. GIS Software Solutions. Getting Started. With MapLogic Layout Manager

Projects and Contracts MMS. This manual will cover. CST Work Order entry. Project Contract Entry. Contract Entry. Change Order Proposal Entry

Transcription:

Tube & Pipe styles disappear Symptom On opening an assembly (which has tube & pipe runs) document it all looks OK. When double clicking "Tube & Pipe Runs" to open it up to work on pipe runs, the pull-down to select different pipe styles is blank. Or if you open Tube and Pipe Styles in the Run section it presents with no styles - except that perhaps the main folder headings are present e.g. "Rigid Pipe with Fittings", "Tubing with Bends" and "Flexible Hose". Solution Overview In writing this document I assume that you are familiar with Inventor, since I gloss over detail to give the concepts only. 1. According to a response from an Autodesk person, that advice was to do the copy, paste and save of a pipe Run then to make it adaptive. This didn't restore the styles. 2. Another idea was to export / import styles e.g. create a new assembly with Tube & Pipe and export the default styles, or scrounge around in older versions of the project to export known working styles etc etc. and import these in to the corrupt assembly. Tried that but it was far from workable - issues were that the styles had to be saved in to a new or different category to the defaults. See Figure 1. The default categories were all corrupt. You needed to save the styles in to a newly / differently named Category as shown in Figure 2. However, I could not spawn any new styles from this - it would not allow a copy of the style in order to edit and create a further one from the style "50mm feed water" shown in Figure 2. It would be way too cumbersome to now import each new style from somewhere else. This lead me to believe that there was a corrupt file that needed to be flushed.

Figure 1 Figure 2 3. Another approach was then to flush all of the folders under AIP > Tube and Pipe, create a new Tube and Pipes instance in the history tree in the work space of the troublesome assembly and then re-populate the Runs folders with the folders which have the pipe runs and parts and routes. This will work if you have no earlier back up of the entire Project folders stored elsewhere. It is a long process but appeared bullet-proof(?) 4. And finally, after discovering 3, above to work I went back and tried replacing the suspected corrupt iam file only - and it solved the problem - this assumes that you

kept earlier instances of the Project and renamed them - in order to find a working copy of the file that we need. In summary, try step 4. above first, (See para. "Step 4" below) otherwise use step 3 above - which is described under heading "A Method that Worked" below.. Importing...? If you happen to have an earlier folder that has been saved to e.g. external drive and you activate that project and open the same assembly (the files & folders must be swapped and renamed i.e. move the corrupt project folder in its entirety to the external drive with another name then move the older project folder to the active project location and name it as if it is the current working copy). Opening that same assembly will present the correct styles and tube and pipe data. Export that whole set of styles and then copy it to the corrupt version on the external drive. Close & exit Inventor and swap and rename the entire project folders to get back to the versions that were present when the problem was noticed - except now you have the styles xml that you exported. Open the corrupt assembly > open Tube and Pipe Runs in the history tree and click the Tube & Pipe Styles icon to open the pop-up window "Tube & Pipe Styles". It will still be blank so now try importing the xml file that you exported in the last step. If this fails it means one of the assembly files is likely corrupt - one of those in the assembly that caused the error - not the entire project! A Method that Worked In my set up I had an issue in the assembly called "Economiser Pump Skid". If you have a Frame or a Pipe Run in that assembly it creates a sub folder beneath where the assembly file is located (if you left all the defaults as is) - inside this is a folder for the pipe runs called AIP - see highlighted below. Below AIP is a folder called Tube and Pipe and beneath that are the folders housing the pipe runs e.g. Run03, Run04, Run05 for me.

Figure 3 Copy the AIP folder and place it somewhere far removed from the project folder path - to be sure that Inventor does no sniff it out. Now go back in to open the troublesome assembly and delete the entire Tube and Pipe Runs item from the history tree - (see below) Save the assembly without the tube and pipe runs - (you will have kept a copy on your external drive!) The idea is that this flushes the iam file of anything that is corrupting it(?) Exit Inventor and go to Explorer.

Figure 4

Delete anything that may still be in the AIP folder. Now open Inventor and open the assembly and start Tube and Pipe and create pipe runs with the same names as those you had - all we want is the shell folder - no routes etc. - just the folder structure. Inventor may offer a name that now includes the assembly name e.g. Figure 5 where "test" was the name of this assembly when initially creating Tube and Pipe. Figure 6 and this was the assembly named Economiser Pump Skid when creating a new pipe run. If it was just Run04 before and you are not sure what is going to happen with the naming, just go ahead and accept the default offered - we can change them later. Once you have the Tube and Pipe Runs created in the history tree;

Figure 7 save the assembly and close Inventor. No need to create routes!!!! You now have the structure that we need to put our original folders back into and tidy up the names. First, delete everything under folder Tube and Pipe as shown below in the red box. Figure 8 These are the empty folders. The Tube and Pipe Runs.iam I think is the file that was corrupt and now has the styles in it - this file has the same name as the history tree naming for Tube and Pipe Runs in the workspace. (It could be prefixed with the assembly name - just making the naming too long - nothing else).

Step 4 If you have a back-up copy of the project, just replace that file!! No need to do all of this! (Note: this is Step 4 mentioned in Solution Overview above) i.e. in Figure 8 above, the file shown with name "Tube and Pipe Runs.iam" is the culprit - you need to find a known working version of this and replace it. Yours may have a different name - it is in the same folder path as in the Figure - beneath YOUR assembly file that contains the tube & pipe run/s.. --- OK, now that we have deleted the folders marked in the red square, we copy the equivalent folders that we stashed away earlier - you now only need the folders to replace these - not the whole AIP folder. These sub folders e.g. Run03, contain the parts that make up the tube & pipe run: Figure 9 Now that you have copied the "populated" folders here, we can start Inventor and open the troublesome assembly again. You should now have a working set of tube and pipe runs with styles - perhaps the only two tidy-ups needed are the naming of pipe runs (to eliminate the assembly name prefix) and secondly to put the colour styles back in to the runs. The naming is done by closing Inventor and renaming the iam file in Figure 8 (to exclude the assembly name prefix) and the iam file in Figure 9 for each of the Run0x folders e.g. inside folders Run03, Run04, Run05 etc.

Now when you open the assembly in Inventor it will ask you which file to use - it will likely already be pointing in the correct directory and you just have to highlight the renamed file and then click Open. Figure 10 If all has gone to plan we are back in the opened assembly file which is working and now has correctly named tube & pipe Runs. If you had selected a colour style and that is now defaulted to "material" I found the following method resolved that. Colours Open a Run and a Route - so now you are in the line sketch to edit the pipe route. From the pipe style pull-down, choose another style (a different style) and let it settle down with that information (do NOT exit). Then re-select the correct style that you had. Now exit the Route edit window (Click the green check tick - "Finish Route") The pipe segments should now refresh with the correct colour. I didn't try it at the top level:

Figure 11 but this may well sort the problem out in one go - otherwise you have to repeat the above for each Route. Good Luck!!