TM-2100 Series Room Command Module

Similar documents
TM-2100 Series Room Command Module

TC-8900 Controller Units with PM-8900 Power Modules

RCM Room Command Module New Style

Suitable for a wide range of installations with wall-mount, flush-mount and hand-held remote control options.

TC-9102 Terminal Controller

Field selectable application type and room module series, via dip-switches on controller

P216 Series Condenser Fan Speed Controller

Room unit with PPS2 interface

TAC Xenta 101-VF. 3-Speed Fan Coil Controller. TAC Xenta

Room unit with PPS2 interface

Room unit with PPS2 interface

Medium User Interface (MUI) Version 3

FXVMA Variable Air Volume (VAV) Box Controller

FX05 Controller. FX05 Controller. Features and Benefits Compatible with standard BAS protocols. LON and N2Open plug-in comm.

Onboard Inputs and Outputs. Remote User Interface. Integral LCD User Interface

N2 Dialer Module. Features and Benefits

P216. Condenser fan speed controller. Product bulletin. Features

FX Input/Output (I/O) Modules XM07 and XM14

CTR21, CTR22, CTR23, and CTR24 Wall Modules

Extended Digital Controller

DP2500 DP0250. Differential Pressure Transmitter. Product Bulletin

Series P215DP Single/Dual Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)

DP DP2500 DP0250

Series A19A/A19B/A19D. Thermostats for Refrigeration, Cooling, Heating, Ventilation and Air-conditioning. Feature and Benefits

HE-6800 Series Humidity Transmitters with Temperature Sensor

Modular Room Control (MRC) Series Expansion Board

FX14 Field Controller

UCU Room Display. Operation Modes. Features. Applications DATASHEET

LX Series Remote Input/Output (I/O) Controller

VAV Modular Assembly (VMA) 1410/1420

S66 Series Electronic Fan Speed Control

Allure EC-Smart-Comfort Series

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

Room controller STRA-17

TAC Xenta 121-FC Programmable Fan Coil Application

I ntroduction. RA Fast Running Electric Actuator. Features and Benefits

Pre-programmed room controller with display and communication

Room Temperature Controllers

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display

C7110C1001A / C7110D1009A WALL MODULES

OEM. Room unit QAA822 with2- wire interface. Building Technologies CLIMATIX TM. For use with Climatix controllers

DX-9100 Digital Controller, Version 2

TAC Xenta 121-HP Programmable Heat Pump Application

BA/BS4S Temperature Sensor Installation & Operating Instructions

Temperature controller Ducted systems

MOD-RI Room Interface Modules with Modbus

Free Energy Band RCC30U Room Temperature Controller for Four-pipe Fan Coil Unit

FX-DIS1710 Local Controller Display Installation Instructions Part No , Rev. B Issued April 2016

QAX50.1 QAX50.5 QAX51.1 QAX51.5. Flexible room unit. Desigo RXC

CDR-RH Room CO 2, Temperature and Humidity Sensors (Controllers)

Room Temperature Controller

FX06 Field Controller

EY-RU : Room operating unit, ecounit

LN Series Remote Input/Output (I/O) Modules

RC-CDTO. Pre-programmed room controller with display, communication and three-point control

Allure EC-Smart-Comfort Series

FCU-MULTI Modbus Fan Coil Unit Controller

M1000 INTELLIGENT ZONE CONTROL SYSTEM

Master room unit for RRV controllers

RCF-230CAD. Room controller with communication for fancoil applications with two analogue V DC outputs

Field Advanced Display

SmartStruxure SmartStruxure Lite ZENO InnPoint. ZENOcontrols.com. compatible with

LN Series Communicating Sensors

EY-RU : Room operating unit, ecounit

CDD Carbon Dioxide Transmitter

BlueWave ~ Intelligent Energy Control. Installation and User Manual for BW2/C and BW3/C versions. Quick Guide

AS-CVTPROx00-0 Zone Bus/N2 Bus Interface Converter

VSD-1MC MANUAL 0-10V / 4-20mA Variable Speed Module with Manual Override

DDC110-L1.. DDC110-L4 technolon Room Module

RCF-230CD. Communicating room thermostat for fan-coil applications with on/off outputs

T7460A,B,C,D,E,F WALL MODULES

Occupancy and Vacancy Sensors ROOM CONTROLLER* DAYLIGHT SENSOR WPP-INT INSTALLATION GUIDE

RXB10.1. Room controller. Siemens Building Technologies Building Automation DESIGO RXB. for chilled ceilings and radiators with EIB bus communication

RS-485 FClink Networking Room Thermostats with LCD for Fan Coil Units

ON/OFF HUMIDIFIER CONTROL (ROOM 0R DUCT SENSOR) WITH OUTDOOR TEMPERATURE RESET OVERVIEW WALL CONTROLLER INSTALLATION (TCY-BH-T-U)

RCF-230CTD. Room controller for fan-coil applications with outputs for two thermal or one 3-position actuator or function for an electric heater

CDD4 Duct Carbon Dioxide Transmitter

RCF-230CAD. Communicating room controller for fan-coil applications with two analogue V DC outputs

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

LX Series Free Programmable LX-PRG6x0-11 Controllers and LX Series Input/Output (I/O) Extension Modules

NT10 Series RS485 Modbus RTU Networking LCD Fan Coil Thermostat

NT50 Series RS485 Modbus RTU Networking LCD Fan Coil Thermostat

Content. Product Description

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

VT8600 Series Installation Guide. Rooftop Unit, Heat Pump and Indoor Air Quality Controller

LN Series Free Programmable LN-PRG6x0-12 Controllers and LN Series Input/Output (I/O) Extension Modules

Room unit with PPS2 interface

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions

Electrical Actuators

Pre-programmed room controller with display and communication

FCU-4 FAN COIL CONTROLLER

Electrical Actuators

THERMOSTATS & CONTROLLERS

INSTALLATION INSTRUCTIONS ECONOMIZERS WITH EXHAUST. For Use with Bard 3-1/2 through 6 Ton Wall Mount Air Conditioners and Heat Pumps

Viconics VT76x6W Water-source Heat Pump Controllers Engineering Guide Specification

SE8300 Room Controller

VA-7700 Series. Electric Valve Actuators. Product Bulletin

CDD4 Series Room CO2 Transmitter Installation Instructions

Room Controllers VTR8300 Line Voltage Fan Coil Controller with VC3000 Relay Pack Technical Cut Sheet

Room Temperature Controller

Transcription:

TM-2100 Series Room Command Module Product Bulletin Code No. 21.144 E Rev. B Issued 02 2007 The TM-2100 series of Room Command Modules are designed for use with the FCC series of DDC terminal unit controllers. It s also suitable for use with Facility Explorer series of field controllers. The set point dial enables the room occupant to adjust the working set point of the controller within the range of 12 to 28 C or +/- according to the model number. TM-2140-0000 TM-2150-0000 The occupancy button enables the occupant to request a "temporary occupied (bypass) mode during "unoccupied" (night/weekend) operation. The "occupied" (comfort) mode is shown by an LED indicator. The Room Command module with a three-speed fan override switch is also available. TM-2190-0000 TM-2160-0000 TM-2160-0002 TM-2190-0005 TM-2160-0005 TM-2160-0007 Figure 1: TM-2100 Series Room Command Module Table 1: Features and Benefits Features Modern and attractive cover with mounting base Terminals located on mounting base. Models available with Occupancy override button, fan speed override and/or setpoint dial Benefits Blends in with room decor. Easy installation. Easy wiring and commissioning. Covers a large number of applications in public and private buildings, offices and hotels. TM-2100 Series Room Command Module Product Bulletin 1

Application Overview Set Point Dial The Room Command Module is available with a set point dial marked 12 28 C or ±. The module must be connected to the controller configured with the corresponding remote set point range. The 12 28 C range module determines the set point of the controller while the ± range module gives a deviation to the room temperature set point programmed into the controller. Occupancy Button When pressed for approximately one second, the occupancy button changes the mode of operation of the controller to "temporary occupied" (bypass) for a period of time as configured in the controller when in "unoccupied" mode. This enables the occupant to request comfort condition at night or at the weekend when the building is normally unoccopied. Mode Indicator The LED indicator directly next to the Occupancy Button shows the current operating mode of the controller as follows: Steady On Off occupied (comfort) or temporary occupied (bypass) mode unoccupied (night) 3-Speed Fan Override The 3-speed fan override switch allows manual control of the speed of the fan. The positions of the switch are as follows: AUTO OFF I II III Automatic operating. Fan speed is set by the controller. Fan OFF Fan low speed Fan medium speed Fan high speed The fan speed override is only active when the controller is in occupied mode. When a low space temperature has been detected the fan runs at high speed with full heating. Table 2: Ordering Data: Room Command Module Ordering Codes Item Code Fan Speed Override Occupancy Button Temperature Setpoint Dial Scale TM-2140-0000 - - - TM-2150-0000 - Yes - TM-2160-0000 - Yes 12...28 C TM-2160-0005 - Yes ± TM-2160-0002 3-speed fan override Yes 12...28 C TM-2160-0007 3-speed fan override Yes ± TM-2190-0000 - - 12...28 C TM-2190-0002 3-speed fan override - 12...28 C TM-2190-0005 - - ± TM-2190-0007 3-speed fan override - ± Built-in Sensor NTC K10 Table 3: Accessories Ordering Codes Ordering Codes TM-1100-8931 TE-9100-8502 TM-9100-8900 Description Plastic Surface Mounting Base - White Unit Mount NTC K10 Temperature Sensor (1.5-m cable) Special tool for enclosure opening 2 TM-2100 Series Room Command Module Product Bulletin

Installation The TM-2100 Series Room Command Module is designed for wall mounting in the room to be controlled. It should be located where the occupant can easily read and adjust the set point dial or fan speed override switch. It should be placed where the temperature is representative of the general room conditions. Cold or warm air draughts, radiant heat and direct sunlight should be avoided. The installation of electrical wiring must conform to local codes and must be carried out by authorized personnel only. Users must ensure that all Johnson Controls products are used safely and without risk to health or property. Mounting Remove the base of the module from the cover by inserting the point of the special TM tool (Ordering Code TM-9100-8900) into the small hole at the center top of the cover. While pressing down gently, prise the base away from the cover. As the two parts separate, remove the tool and continue to pull the cover away from the base until the cover is free. To reassemble the room command module, place the cover over the lower edge of the base and push the upper part of the cover until it "clicks" firmly in place. Mount the base on the wall to cover the electrical output and secure with at least two screws. TM-9100-8900 Figure 2: Room Command Module TM-2100 Series Room Command Module Product Bulletin 3

Direct Surface Mounting over Electrical Outlet For direct surface mounting: Surface Mounting with Mounting Kit and Conduit Figure 4: Mounting kit Figure 3: Module Base - Dimensions in mm (inches) Mount the module base on the wall to cover the electrical outlet and secure with at least two screws. 1. Remove one of the notches (A) with a suitable tool for the conduit entry. 2. Mark the position of the holes (B) on the wall and drill holes 5 mm in diameter. Insert plastic plugs into holes. Figure 5: Mounting kit 3. Position and fix the mounting base to the wall using the two long screws (C) provided in the kit. 4 TM-2100 Series Room Command Module Product Bulletin

4. Fix the base of the TM-2100 to the mounting base using the two short screws (D) provided in the kit. Wiring Before connecting or disconnecting any wires, ensure that all power supplies have been switched off and all wires are potential-free to prevent equipment damage and avoid electrical shock. Terminations are made on the terminal blocks in the base of the module, which accept up to 1.5 mm 2 wires. Follow the wiring diagrams shown in the figures below. All wiring to the module is at extra low (safe) voltage and must be separated from power line voltage wiring. Do not run wiring close to transformers or high frequency generating equipment. Complete and verify all wiring connections before applying power to the controller to which the module is connected. Figure 6: Surface Mounting base (Dimensions in mm) Figure 7: TM-2140-0000 Figure 8: TM-2150-0000 TM-2100 Series Room Command Module Product Bulletin 5

Figure 9: TM-2160-0000 and TM-2160-0005 Figure 10: TM-2160-0002 and TM-2160-0007 6 TM-2100 Series Room Command Module Product Bulletin

Figure 11: TM-2190-0000 and TM-2190-0005 Figure 12: TM-2190-0002 and TM-2190-0007 TM-2100 Series Room Command Module Product Bulletin 7

Dimensions Figure 13: TM-2140-0000 Figure 14: TM-2150-0000 8 TM-2100 Series Room Command Module Product Bulletin

Figure 15: TM-2190-0005 Figure 16: TM-2160-0007 TM-2100 Series Room Command Module Product Bulletin 9

Figure 17: TM-2160-0000 Figure 18: TM-2190-0000 10 TM-2100 Series Room Command Module Product Bulletin

Technical Specifications Supply Voltage Power from Controller Ambient Operating Conditions 0 to 50 C 10 to 90% RH non condensing Ambient Storage Conditions -20 to 70 C 10 to 90% RH non condensing Terminations Terminal block in base for 1 x 1.5 mm² (maximum) cable. Temperature Sensor NTC Thermistor 0 to 50 C, 10 kohm at 25 C Remote Set Point 10 kohm potentiometer marked for 12 C to 28 C or ± (range ±3 K ) as configured in controller 3-Speed Fan Override 10 kohm potentiometer with mechanically guided positions for Auto, Off, I (low speed), II (medium speed) and III (high speed). Occupancy Button Momentary contact (switches 5V at 1 ma). Mode Indicator Green LED (5V, 4 ma) Mounting Direct surface mount or plastic base for surface mount with wiring conduits (See Ordering Codes.) Materials Enclosure Colors Base Occupancy Override Button Fan Speed Override Dial Setpoint Dial Enclosure ABS+PC; self estinguishing HB UL 94 Base Occupancy Override Button White RAL9016 (GE86280 ) Fan Speed Override Dial Setpoint Dial Grey RAL7047 (GE GY81118) Protection Class Enclosure IP30 (EN 60529) Dimensions (H x W xs) TM-2140-0000 TM-2150-0000 80 mm x 80 mm x 32 mm TM-2160-000x TM-2190-000x 80 mm x 80 mm x 35 mm Shipping Weight 0.15 kg Conformity EN-61000-6-3 EMC Directive 89/336/EEC EN-61000-6-2 The performance specifications are nominal and conform to acceptable industry standard. For application at conditions beyond these specifications, consult the local Johnson Controls office. Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. Johnson Controls International, Inc. Headquarters: Milwaukee, Wisconsin, USA Branch Offices: Principal Cities World-wide TM-2100 Series Room Command Module Product Bulletin 11 Published in Lomagna - Italy. www.johnsoncontrols.com