Introduction Guide. Cloud Data Service CONTEC CO., LTD.

Similar documents
CONPROSYS. M2M Controller CPS-MCS341. System Setup Guide CONTEC CO., LTD.

IG601 Intelligent Gateway Quick Guide

DIO-1616LN-FIT DIO-0808LN-FIT

DIO-0808RN-USB. N Series for USB Isolated Digital I/O Unit(8ch Relay Output, 8ch DI) DIO-0808RN-USB 1. Ver.1.02

UR72 & UR75 Industrial Cellular Router

UR51 Industrial Cellular Router

Industrial L2+ Multi-Port Full Gigabit. Managed Ethernet Switch IGS T2S/IGS UP1T2S IGS P2S/IGS P4S/IGS P2T2S

V2403 Quick Installation Guide

User Manual. cmt-svr Startup Guide

Industrial L2+ Multi-Port Full Gigabit. Managed Ethernet Switch IGS-10020MT / IGS-10020PT/HPT / IGS-10080MFT IGS-12040MT / IGS-20040MT / IGS-20160HPT

User Manual. cmt-svr Startup Guide

Hard Disk Unit for PC CPU Module Compatible with MELSEC-Q Series PPC-HDD(MS)A User s Guide

Quick Installation Guide

Installation and Configuration Quick Guide. R3000 Lite. Industrial Dual SIM Cellular VPN Router (1 Eth + 1 RS RS USB Host)

L2+ Multi-Port Full Gigabit Managed Ethernet Switch IGS-10020MT / IGS-10020PT / IGS-10020HPT / IGS-10080MFT / IGS-20040MT. Quick Installation Guide

CONPROSYS. 24VDC AC-DC Converter CPS-PWD-30AW User s Guide CONTEC CO., LTD.

Installation Guide AT-OMNI-121

Installation and Configuration Quick Guide. R3000 Quad. Industrial Cellular VPN Router with 4 Ethernet Ports (4 Eth + 1 RS-232/1 RS USB Host)

iologik 2500 Series Quick Installation Guide

256 MB RAM. 256 MB 32 bits RISC Cortex-A8 600MHz SD Card Slot. N/A USB Host. N/A USB Client

FP-2000/2010 FieldPoint Quick Start Guide

Quick Start Guide. GV-Video Server

Industrial 24-Port 10/100/1000Mbps Managed Gigabit. Switch (-40~75 degrees C) with 4 Shared SFP Ports IGSW-24040T. Quick Installation Guide

Installation Guide AT-OMNI-111

Installation and Configuration Quick Guide R3000. Industrial Dual SIM Cellular VPN Router 2 Eth + 1 RS RS USB Host.

DIO-1616LN-FIT. Features. Specifications. Ethernet Remote I/O F&eIT N Series Isolated Digital Input/Output Unit DIO-1616LN-FIT 1. Ver.1.

F Series Indoor Fixed IP Camera. Quick Start Guide

Quick Start Guide. GV-Fisheye IP Camera. 1 Introduction. Packing List

Installation and Configuration Quick Guide R2000. Industrial Dual SIM Cellular VPN Router (2 Eth + 2 SIM) Package Contents

TRP-C34H. Ethernet to 4 RS232/422/485 Converter. User s Manual. Printed Sep Rev 1.1

Quick Start Guide. Mounting the Essential Plus and Elite

VP101-BT Installation Guide

Hybrid IP-PBX Information about IP Proprietary Telephones KX-TDA200. Panasonic KX-TDA100 Panasonic KX-TDA200. Phone:

24-Port 100/1000X SFP + 4-Port 10G SFP+ Managed. Metro Ethernet Switch MGSW-28240F. Quick Installation Guide

Installing the Cisco Unified Videoconferencing 3545 MCU

INDUSTRIAL POE SWITCH

L2+ Managed Metro Ethernet Switch MGSW / MGSD Series

FP-1600 FieldPoint Quick Start Guide

Industrial L2/L4 Managed Gigabit Switch. With 4-Port 802.3at PoE+ IGS P4T/IGS P4T2S. Quick Installation Guide

User Manual Revision: A04 June 23, QuEST Rail LLC.

EasyIO FG-20 Installation Guide v1.1. FG-20 Installation Guide

Quick Start Guide. GV-Video Server. 1 Introduction. Packing List

Quick Start Guide. GV-Video Server

MGate 5111 Quick Installation Guide

MGate 5105-MB-EIP Quick Installation Guide

CONPROSYS. 24VDC AC-DC Converter CPS-PWD-90AW User s Guide CONTEC CO., LTD.

Quick Start Guide. 1 Introduction. GV-Box Camera GV-BX120D / 220D / 320D. Packing List

Machine TV Interface. mtv-100. Memory Processor. I/O Port RTC. Power. Specification. Certificate Software

Ethernet/Network Communications Module. Installation and Programming Manual. LINQ2 - Two (2) Port Connectivity Module. More than just power.

User s Guide. Ethernet Module for Barcode Printer

Basic configuration. 1 Basic configuration

CONPROSYS. CPU Module CPS-MCS341-DS Hardware Manual CONTEC CO., LTD.

Yealink VC120 Video Conferencing System Quick Start Guide

Open Smart Metering Gateway EWIO-9180-M. Energy consumption monitoring and energy monitoring in buildings, on machines, installations and systems

MOXA VPort 2110/2140/2141 Video Server Quick Installation Guide

1. Safety Precautions (Read these precautions before use.)

L2+ 24-Port Gigabit Managed Switch with. Hardware Layer3 IPv4/IPv6 Static Routing GS S8C GS S8CR. Quick Installation Guide

RC90 Upgrade Procedures

CONPROSYS. CPU Module CPS-MCS341-DS Hardware Manual CONTEC CO., LTD.

3.1 Updating Web Package Updating OS... 16

MGate 5118 Quick Installation Guide

UC-8410A Quick Installation Guide

Netbiter EC300 Series

MGate TM EIP3000 DF1 to EtherNet/IP Gateway User s Manual

Ethernet Interface Module

Industrial IP67-rated 4-Port 10/100/1000T at PoE + 2-Port 10/100/1000T. Managed Ethernet Switch. (-40~75 degrees C) IGS-604HPT-RJ

MSD-SRF2XM Multi-port RS-232 to Ethernet Data Gateway User Manual

EasyIO FG-32 Installation Guide v1.2. FG-32 Installation Guide

Industrial 8-Port 10/100/1000T 802.3af/at PoE + 2-Port 100/1000X SFP Managed Switch with Wide Operating Temperature

SIP IP VIDEO DOOR PHONE.

User Guide Automatic Transfer Switch (ATS)

Helios PD Large Display Meter Quick Start Guide

NPort 6600 Series Quick Installation Guide

MODEL: GR8-EM. Communication Adaptor GR8 Series

DL-10. User Manual. RS-485 Remote Temperature and Humidity. English Ver. 1.0, Jul. 2017

NISTA DEVICES GmbH 2013 All Rights Reserved. Door Access Control with the VoIP interface IP epcr Release 1.02

Quick Installation Guide

Setting Up Your Cisco Unified Videoconferencing 3515 MCU

Installation/User Manual

Getting Started KX-NCP500 KX-NCP1000. Pure IP-PBX. Model No.

CODESYS Modbus Master CPS-PCS341MB-DS Hardware Manual

AIO LN-USB. Features. N Series for USB Multifunction DAQ Unit (8ch AI, 2ch AO, 16ch DIO) AIO LN-USB 1. Ver.1.01

VL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A.

Manual 601: : USB/RS232. Specifications. Contents. Options

WRM 247+ QUICK GUIDE

Installation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date:

S SENECA. Installation Manual Z-TWS4. Z-PC Line. Web Multifunction Controller Straton / Linux

Power Xpert Meter 2000 Gateway Card Kit

Power Xpert Meter 2000 Gateway Card Kit

M3 Snap-On. User Guide. Product Model: A-SNO-ATYP-110-R00 (A type), A-SNO-BTYP-110-R00 (B type) Compatible Device: M3 GREEN and SKY

Unified Office Gateway UMG Quick Installation Guide. Version: 1.0

TH800DS CONTROLLER MANUAL

IFS NS3552-8P-2S and NS3550-2T-8S Quick Installation Guide

AUDIO AND VIDEO DOOR ENTRY SYSTEM WITH NEXA CODED PANEL

Yealink VC500 Full HD Video Conferencing Endpoint Quick Start Guide

Advanced Graphical Interface, AGI 100

Startup Guide. NetAXS-123. Version 5.2

Serial to Ethernet Converter

TRBOnet Swift A200. Radio-over-IP Gateway. User Manual. Internet. US Office Neocom Software Jog Road, Suite 202 Delray Beach, FL 33446, USA

Network Video Recorder Quick Operation Guide

Transcription:

Introduction Guide Cloud Data Service CONTEC CO., LTD.

Table of Contents Before installation Items to Set Up The list of items to set up the CONPROSYS. Connector Positions for Setup The names and positions are illustrated. 3 Connect the Controller How to connect the computer, the controller, and the power unit. 4 Check Communication Set the Computer Network The setup procedure of the computer IP address. Check Communication How to check whether the computer and the controller are communicating properly. 6 8 Set the Controller 9 Setup The setup procedure of the Integrated and the Configurable controllers on a DIN rail or on the wall. Check Operation How to check whether the controller is operating properly. Appendix Handy Functions Web monitoring and task functions of the controller are described.? 8

Items to Set Up (Integrated type) The product requires the items listed below to set up. Have the followings ready. Controller (CONPROSYS product) Computer Battery unit (Individually sold: CPS-PWD-5AW-0 recommended) AC power cable (Individually sold: IPC-ACCODE3 recommended) LAN cable (Cross cable) Power cable (This comes with the above recommended battery unit) Items to Set Up (Configurable type) The product requires the items listed below to set up. Have the following items ready. Controller (CONPROSYS product) Computer Battery unit (Individually sold: CPS-PWD-90AW4-0 recommended) AC power cable (Individually sold: IPC-ACCODE3 recommended) LAN cable Cross cable Power cable (This comes with the above recommended battery unit)

Connector Positions for Setup (Integrated type) See the positions to connect each cable. [Top] Power [Front] -4VDC SD USB RS-3C COM B RESET SHUT DOWN SW LAN A LAN B DI/CNT DO0 DO AI0 AI MODE TERM Isolated RS-4A/485 COM A SW [Bottom] LAN Digital I/O This layout of the connectors is the example of the multiple I/O model.please see an appropriate controller manual for your model. Connector Positions for Setup (Configurable type) See the positions to connect each cable. [Front] SW 4VDC V + V - Power ON PWR ST ST ERR DIO ID L H 3 0 SD SD RX A TX MCOM DIO0 DIO Digital I/O DIO DIO3 N.C A LAN A B 3

Connect the Controller (Integrated type) Follow the instructions below to connect the computer, the controller, and the power unit. Connect to LAN A Connect to the power connector Connection diagram Battery unit AC plug Computer LAN cable Controller AC power cable Power cable FG (Green) GND (Black) (N) AC (G) +V FG GND +V (Green) (Black) (Red) Power cable +V (Red) AC (L) AC (N) FG (G) -V +V N ( 白 ) L (Black) FG (Green) AC power cable AC power cable L N FG (Black) (White)(Green) Connect the power unit with AC plug, then turn on the computer. * After connecting the power unit with AC plug, it takes a few minutes for the controller to complete the start-up. (approx. - min) 4

Connect the Controller (Configurable type) Follow the instructions below to connect the computer, the controller, and the power unit. Connect to LAN A Connect to the power connector Connection diagram Battery unit AC plug Computer LAN cable Controller AC power cable +4V (Red) GND (Black) + - - DC_OK DC4V 3.8A OUTPUT Connect the power unit with AC plug, then turn on the computer. INPUT AC00-40V N L * After connecting the power unit with AC plug, it takes a few minutes for the controller to complete the start-up. (approx. - min) =Power cable FG FG N L (Green) (Green)(White)(Black) =AC power cable 5

Set the Computer Network Follow the Computer Network Setting Procedure described below and set the network to make the IP addresses as shown. The product must set a unique IP address for the bold part (00 or 0) that is not used by other devices on your network. Computer IP address 0... 00 Subnet mask 55. 0. 0. 0 Controller IP address 0... 0 Subnet mask 55. 0. 0. 0 * The factory default setting Computer Network Setting Procedure (for Windows 0) Click [Network & Internet] on [Windows Settings] screen. Click [Change adapter options]in [Network status]. 3 Double-click the appeared [Ethernet]. Go on to the next page. 6

4 Click [Property] in [Ethernet Status] dialog box. 5 Double-click [Internet protocol version 4(TCP/IPv4)] in [Ethernet Properties] dialog box. 6 In the [Internet protocol version 4 (TCP/IPv4) property], set IP address and Subnet mask as shown below. IP address 0... 00 Subnet mask 55. 0. 0. 0 Select 7 Click [OK] [OK] [Close] to close the dialog box and complete the network setting. 7

Check Communication Start the Internet Explorer on your computer. Enter IP address (0...0) of the controller in the address bar, then press [Enter] key. The dialog box asking for the User name and Password appears, enter them and click [OK]. 0...0 [Default setting] User name : Password : mc34 mc34 * For an actual operation, change User name and Password in [User name and Password ] from the Maintenance menu. * After entering IP address and pressing [Enter] key, the Security certificate might appear on the screen. Choose Continue to this website. If [Status menu] of Web browser menu appears, it indicates the success of the communication between the computer and the controller. Status menu screen 8

Mounting on a DIN Rail Set the Controller (Integrated type) Pull down the two fixed hooks on the bottom to unlock; preferably with a slotted screwdriver. Fixed hook ()Hang the controller on the upper part of a DIN rail, ()and press the product to the lower side of the DIN rail. 3 Push up the fixed hooks to lock on the DIN rail. Place the controller onto the wall Appropriate screws (fit into φ3.5 hole) are required to set the product on the wall. The screws can be purchased individually. 9

Mounting on a DIN Rail Set the Controller (Configurable type) Pull down the fixed hook on the bottom to unlock; preferably with a slotted screwdriver. Fixed hook ()Hang the controller on the upper part of a DIN rail, ()and press the product to the lower side of the DIN rail. 3 Push up the hook to lock on the DIN rail. 0

Check Operation (Digital I/O of the Integrated type) Connect the pin number (DI0) and 7 (DO0+), then 6 (DI_MCOM) and 8 (DO0-) of the digital I/O connector with the lead-wire to create the connector for operation check. * The lead-wires are not included in the package. Please use the recommended wire, AWG8-6. Pin number Signal name 0 9 8 7 6 5 4 3 DO- DO+ DO0- DO0+ DI_MCOM DI3/CNT DI/CNT0 DI DI0 N.C. This layout of connector pins is the example of the multiple I/O model. Please see an appropriate controller manual for your model. 3 4 5 6 7 8 9 0 Fasten the screws with a driver to secure the lead-wires. Lead-wires Operation check connector Place the operation check connector into the digital I/O connector of the controller. 3 On your computer, start up Internet Explorer and enter IP address (0...0) of the controller in the address bar, then press [Enter]. The screen asking your user name and password appear. Enter them in the dialog box and click [OK] to show Web browser menu. 0...0 [Default setting] User name: Password: mc34 mc34 Go on to the next page.

4 From Web browser menu, click [Monitoring view] in [Status menu] to show the screen for I/O check. 5 Click [DO0] in Digital Output on the I/O check screen of the controller to switch on/off. This turns on/off the [DIO0] lamp of Digital Input. This confirms that the controller is operating properly. Click Lamp is off ON Lamp turns on

Check Operation (Digital I/O of the Configurable type) Connect the pin number (DIO0) and 3 (DIO) of the digital I/O connector with the lead-wire to create the connector for operation check. * The lead-wire is not included in the package. Please use the recommended wire, AWG8-6. Pin number 3 4 5 6 Signal name MCOM DIO0 DIO DIO DIO3 N.C. 6 5 4 3 Lead-wires Fasten the screws with a driver to secure the lead-wire. Operation check connector * The configurable controller requires a signal setting from Web browser menu. Place the operation check connector into the digital I/O connector of the controller. 3 On your computer, start up Internet Explorer and enter IP address (0...0) of the controller in the address bar, then press [Enter]. The screen asking your user name and password appear. Enter them in the dialog box and click [OK] to show Web browser menu. 0...0 [Default setting] User name : Password : mc34 mc34 Go on to the next page 3

4 From Web browser menu, go to [Module setting] in [Maintenance menu] and click the Controller image or Configure in the Module list. Module setting 5 Change those DIO0, DIO set in the Step to value DIO0 DI, DIO D O respectively. (Default settings are all DI) Click set after setting. Change values Go on to the next page 4

6 After changing the settings, go to save to ROM in the Maintenance menu and click the button save to ROM to save the changes. PWR LED will be on once the changes are saved (saving time: approx. 0 seconds). After completion of the saving, click [Reboot/Shutdown] to reboot the controller (approx. minute). 7 To create a monitoring view screen, open [Monitoring edit] in [Maintenance menu], and change to [Run] in the Mode that is located on the upper-right side. Go on to the next page 5

8 From Components list on the left side, select Switch and Lamp controls and drag & drop them onto the Layer area. Drag & Drop Layer area 9 () Click the Switch control on the layer area to activate. () Click [! OnPressd] in the [Property tab] on the right side, (3)and click icon in the Link Box. (4)Select [CPU_DO0] in Device Tree and click (5) OK. This connects the Switch and the connector [DIO]. 4 3 5 Go on to the next page 6

0 () Click the Lamp control on the layer area to activate. () Click [value] in the [Property tab] on the right side, (3) and click icon in the Link Box. (4) Select [CPU_DI00] in Device Tree and click (5) OK. This connects the Lamp and the connector [DIO0]. 4 3 5 Clicking the Switch on the Layer area turns the Lamp on/off. This also turns on/off the LED of the controller. This confirms that the controller is operating properly. Click the Switch to turn on/off The Lamp turns on/off 7

Handy Functions The MM controller contains functions to monitor and operate measured or calculated values, as well as to customize pages. Moreover, the controller features a function to assemble processing tasks such as calculation and controlling by placing the controls on the pages like drawing them in the flowchart. Monitoring function CONPROSYS HMI (Human Machine Interface) - A monitoring screen can be created easily. - No expert knowledge of programming required. Simply monitor through Web browser. - Remote monitoring of facilities to check the conditions, troubles, performances, and to stop operations. Easy creating a monitoring screen. Remote location MM controller Facilities For operation details, please visit the Contec website and refer to the manuals on line. http://data.conprosys.com/help/hmi/v/en/ Task function CONPROSYS VTC (Visual Task Control) - No development environment is required. Signal processing can be added easily through Web browser. - Programming can be done by script language with the controls through Web browser. Easy setting through Web browser. MM controller For operation details, please visit the Contec website and refer to the manuals on line. http://data.conprosys.com/help/task/v/en/ 8

Security Warning When connecting to the network, be aware of security-related problems. See the examples of Security measures below and set up the product properly along with the network devices. [Information security risks] - Unauthorized access from the outside through a network could cause the system halt, data damage, or exposure to malware *. - Invaded and used as a stepping stone, a device might attack the others through networks. (a victim becomes an assailant) - Information might leak without realizing due to the connection to the network. - Secondary damages such as harmful rumors, liability in damages, social credibility fall, and opportunity loss are expected led by the troubles described above. * Malware (Malicious Software) is software that brings harm to a computer system and performs unintended operations. [Security measures - e.g.] - Do not keep using the default password. (Refer to the product manual for the password setting). - Set a strong password. Combined with upper and lowercase letters, and numbers so that it cannot be easily analogized by others. - Change the password periodically. - Disable unnecessary network services and functions. - Restrict access to the network with network devices. - Restrict ports to be released on the network with network devices. - Create a closed network connection using such as dedicated network or VPN*. * VPN (Virtual Private Network): a secured network that wards off unauthorized access by protecting the communication path with authentication and encryption. Unfortunately, there are no perfect ways to avert unauthorized access or close a security hole that are endlessly found day and night. Please understand that risks are always involved with the Internet connection, and we strongly recommend a user should constantly update information security measures. 9

MEMO 0

U.S.A. TAIWAN CHINA SINGAPORE CONTEC DTx INC. 800 Penn Street, Melbourne, FL 390 U.S.A. Tel. : +-3-78-07 THE NETHERLANDS CONTEC CO., LTD. AMSTERDAM BRANCH WTC Amsterdam Tower C Level, Strawinskylaan 49, 077XX Amsterdam, THE NETHERLANDS Tel. : +3-0-38-0960 TAIWAN CONTEC CO., LTD. CONTEC (SHANGHAI) CO., LTD 9FL, No. 738, Zhongzheng Road, Zhonghe District, Xinbei 35 TAIWAN Tel. : +886--87-8669 Room 00, Qilai Building, No. 889, Yishan Road, Shanghai 0033 CHINA Tel. : +86--540-88 KOREA CONTEC CO., LTD. Korea Liaison Office 9, Cheongmyeong-ro beongil, Yeongtong-gu, Suwon-si, Gyeonggi-do, KOREA Tel. : +8-0-6557-359 SINGAPORE CONTEC PTE. LTD. Blk 400, Ang Mo Kio Ave. 0 #07-0 Techplace I, 56966 SINGAPORE Tel. : +65-6459-667 http://www.contec.com Headquarters: CONTEC CO., LTD. 3-9-3, Himesato, Nishiyodogawa-ku, Osaka 555-005, Japan Introduction Guide 704