High Power Electronic Gear Installation and operation Guide

Similar documents
LINEAR LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , ,

COMPACT LED DRIVERS. ComfortLine Residential. ComfortLine RESIDENTIAL , , ,

COMPACT LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , ,

COMPACT LED CONVERTERS 48 V

CC COMPACT DIP SWITCH

COMPACT LED DRIVERS. PrimeLine DALI dimmable & Selectable Current (Dip Switch) PrimeLine DALI DIMMABLE & SELECTABLE CURRENT (DIP SWITCH)

COMPACT LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , , , , , ,

ELV12 Series. Instruction Manual

LINEAR LED DRIVERS. ComfortLine Industry Selectable Current (LEDset) ComfortLine INDUSTRY SELECTABLE CURRENT (LEDset) ,

RTU500 series Data Sheet Power Supply CP-E 24/2.5

Power supply CP-C 24/5.0

LINEAR LED DRIVERS. ComfortLine NFC. ComfortLine NFC , , ,

Voltage Current Front-mounting bracket

LINEAR LED DRIVERS. PrimeLine DALI dimmable. PrimeLine DALI DIMMABLE , , , , ,

LED Driver DC-String

Power supply CP-E 24/10.0 Primary switch mode power supply

Power supply CP-E 48/1.25 Primary switch mode power supply

LED Driver Compact fixed output

COMPACT LED DRIVERS. EasyLine Selectable Current (Output Terminal) EasyLine SELECTABLE CURRENT (OUTPUT TERMINAL) , , ,

LED Driver Linear / area fixed output

LC35SE-CC LOOP

LC51SE-CC LOOP

Power supply CP-E 24/0.75 Primary switch mode power supply

QUINT-BUFFER/24DC/24DC/40

LED Driver Linear / area fixed output

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

Redundancy unit CP-A RU

PHOENIX CONTACT - 07/2006

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

LED Driver Linear / area fixed output

Operating instructions. Standstill monitor A / / 2011

Power supply CP-D 12/2.1 Primary switch mode power supply

LED Driver DC-String

VLT Line Filter MCC 107 EMC Filter Series VLT Midi Drive FC 280 (K1 K3)

LED Driver Compact fixed output

Withstands max. 320 VAC (max. 1 hour) *) Low frequency, LED load: Cree XP-G L LEDs. 350 ma 600 ma Fixed output 850 ma P Rated

LinkRay LED Drivers EasyLine With Selectable Current , Typical Applications

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

LED Driver Linear / area fixed output

LED Driver Linear / area fixed output

LED Driver Compact fixed output

LED Driver Compact fixed output

Table of Contents. Safety. Attention. Warnings

Chrome DIN Rail Power Supply 12V 9.96W 1 Phase (Class II & NEC Class 2) / DRC-12V10W1A

VP ELECTRONIQUE MASSY - Tel

MINI-PS AC/10-15DC/8

LED Driver Compact fixed output

MC 11 EB-2 Power supply cabinet with external bus, AC version

LED Driver Linear / area fixed output

LED Driver Compact fixed output

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

CUS150M1 Instruction Manual

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

LED Driver Compact fixed output

LED Driver Compact fixed output

LED Driver Linear / area fixed output

LED Driver Linear / area fixed output

LED Driver Linear / area fixed output

LED Driver Linear / area fixed output

Conductive Level Controller

LL1x50-E-DA. 1x50 W Dimmable DALI LED driver. 50 W V 0 / 50 Hz 60 Hz. Functional description. Mains characteristics

LED Driver Compact fixed output

S8VE (60/90/120/180/240-W Models)

LED Driver Linear / area dimming

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

Model No. ( Single Output ) ATC-3.3S ATC-5S ATC-12S ATC-15S ATC-24S Max Output Wattage (W) 10W 10W 10W 10W 10W VAC or VDC

Switch Mode Power Supply S8VT 120/240/480/960 W Models

LED Driver Linear / area dimming

Type Quickstart (from device Version 2)

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

Chrome DIN Rail Power Supply 5V 7.5W 1 Phase (Class II & NEC Class 2) / DRC-5V10W1AZ

LED Driver Linear / area dimming

LL1x150-CR-DA. 150 W Dimmable DALI-2 LED driver. 150 W V 0 / Hz. Functional Description. Mains Characteristics

LED Driver DC-String

Model 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1

UNO-PS/1AC/12DC/30W. Primary-switched power supply unit. Data sheet. 1 Description

300 WATT, PFC, OPEN FRAME POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, RMW 300W SERIES

Extension module for lighting control

CPCI-PS24 24V-Power Supply

PTo 150/ DIM HCI 150 W, HQI 150, NAV 150 W, and other similar commercially available 150 W lamps System wattage:

Redundancy Module QUINT-DIODE/40

DEB 575/1200. Electronic Flicker Free Ballast DMX MOD INSTRUCTION AND MAINTENANCE MANUAL

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter

Safety Standards. Model Number:

Safety Standards. Model Number:

Symmetra PX 160. Maintenance Bypass Enclosure. Installation 05/

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

LED Driver Compact dimming

Ordering Information. Three-phase Input Switch Mode Power Supply S8VT S8VT. Model Number Legend

Model 8020-STC. Kelvin Standard Triaxial Connector Card. Description / October 2014 *P * 1

MDM 011-Z1 Regen Resistor

VS-P Series. TDK-Lambda INSTRUCTION MANUAL

LED Driver Compact fixed output

LED Driver DC-String

LC35SE-DA W SELV Dimmable DALI-2 LED driver. 35 W V 0/ Hz. Functional Description. Mains Characteristics

net4more IP connected lighting system net4more Driver net4more driver DC 30W mA un:c LED Driver for net4more systems

Chameleon Stand-alone

Transcription:

High Power Electronic Gear Installation and operation Guide 96268731 GT 1 KW 230-240 V HQITS-S DGE CLI WI SC 96267936 GT 2 KW 230-240 V HO/HF DGE CLI WI SC IP21 IP21 electronical gear for 1 and 2 kw HIT-DE lamp, suitable for the dedicated Altis DGE floodlight. To be installed remotely in dedicated cabinet. Ignitor not included (integral to the Altis DGE ignitor box) Lamp Compatibility: HQITS-HF (OS); MHNSB-HO (PH) Weight: 3,6 kg Warning! Installation is entirely at your own risk. Read this manual from cover to cover before attempting installation and follow all safety instructions. Do not attempt installation unless you are suitably qualified. It is essential to isolate the electronic ballast/ignitor or the connected luminaire electrically from mains voltage before maintenance! ~ 1 ~

Installation The electrical installation has to be completed as described in Dimensions and Connection. Ballasts and fixtures / luminaires must be grounded in accordance with the National Electrical Code and any local regulations. Without proper fixture and ballast grounding, a shock hazard may occur due to the fixture becoming energized by an internal ballast failure. In addition, all ballasts have normal leakage current. When the ballast is properly grounded, the leakage current does not constitute a hazard when conductive parts are touched. Attention: The ballast/ignitor has been designed to be installed into suitable enclosure, cabinets etc. that guarantee protection against touching of active parts and life voltages. Provide for sufficient cooling when installing one or more ballasts and the corresponding components into suitable enclosures / switchgear cabinets, poles and boxes. Ambient temperature around the ballasts must not exceed 45 C during normal continuous operation. Operation After connecting to mains voltage, the ballast tries to start the HID lamp of the connected luminaire by activation of the ignitor. In case an immediate start of the lamp is not possible, for example because the lamp is still too hot, every 30s a new ignition sequence will be started automatically. This automatic restart-mode is restricted to a maximum 20min period. If no successful start can be enforced within this time period, the ballast has to be isolated from mains voltage and the installation as well as the lamp has to be checked. In case of overtemperature on the components inside the driver the lamp is turned off, press Reset button for restart after cool down. ~ 2 ~

Technical data Type GT 1KW HQITS-S GT 2KW HO/HF Order No. 96268731 96267936 Rated ballast power 1040W 2080W Rated lamp-type HQITS-S HQITS-HF; MHNSB-HO Input voltage range for operation 210-240V±10% 210-240V±10% between phase and neutral of a single phase system Maximum Input current 6.1A 11.8A Line frequency 50/60Hz Maximum inrush current (t off 60s) < 35A Open circuit voltage approx. 400V 400V Maximum lamp voltage 140V (f=250hz) 240V (f=250hz) Maximum lamp current 9.5A 11A Auto restrike function 10s max. ignition time; 30s break; 30 times repeats Protection Ground fault output monitoring with latched shutdown, restart with main voltage reset and reset button (press >= 3s) Over temperature protection, restart with main voltage reset or reset button Short circuit protection, automatic shutdown after 4 min; restart with main voltage reset or reset button Open circuit protection / End-of-lamp-life detection, reset with reset button only Current ripple < 4% Earth leakage current 264V, 60Hz < 2,5mA < 2,5mA Efficiency 0,91 typ. at U e = 230V, UL= 120V 0,93 typ. at U e = 230V, UL= 210V Max. power dissipation 130W 200W Power fluctuation in lamp arc / ± 5% / ± 1% mains Ambient temperature range -10 C.45 C Recommended ambient 20-30 C temperature of use Output power tolerance ± 5% EMI internal noise filter Maximum dimensions in mm L x W x H 392 x 145 x 116 Weight in grams 3.600gram PFC Active Power Factor Correction Lamp on LED Lamp ON Approvals - Generally all discharge lamps can be supplied within following limits: Limits: GT 1 KW: IL max = 9,5A UL max = 140V P max = 1040W GT 2 KW: IL max = 11A UL max = 240V P max = 2080W ~ 3 ~

Connections Mains input Output to ignitor Screw clamp terminals Wire cross section to handle: 1,5 to 4 mm² (6mm 2 solid wire) Protective Earth Recommended torque value 0.6Nm N Mains ~ 0.6Nm L Mains ~ 0.6Nm Screw clamp Wire cross section to handle: terminals 0,5 to 4 mm² (6mm 2 solid wire) Protective Earth 0.6Nm X4 Low Frequency Square Wave 0.6Nm X3 Low Frequency Square Wave 0.6Nm X5 *) control 0.6Nm *) Not used in combination with 2-wire ignitors LED Status indicators LED Status Operating/error mode description Reset by Continuously lighting Flashing at low frequency (~0.5Hz) Flashing at higher frequency (~5Hz) Flashing with short flash pulses Lamp on - Ignition mode - End-of-lamp-life shutdown Reset Button Error mode *) Reset Button *) Refer section First action in case of malfunction for list of possible root causes ~ 4 ~

Dimensions, mounting-, wiring data and tc - testpoint. The line markes the neccessary space for airventilation 40 369,5 392 145 holes for mounting a fall protection 40 40 115,5 10 strain relief LED Reset Airflow from top to bottom tc-testpoint tc max = 85 C Ø12 88 dimensions in mm L N PE X5 X3 X4 PE Ignitor Maintenance recommendations Visual check shall be performed each year to ensure ballast performance over time: No dust or moisture on ballast. ~ 5 ~

Ignitor Ignitor delivered pre-wired in floodlight In case of replacement, please use: 96270858 AMORC. KZG 12-8 THORN 12A / 8kV *) max input voltage: 400 Vp ca.48 30.8 83 75 3 (X3) 42 68 62.5 2 (X4) Ballast tc - testpoint tc max = 95 C 21 ca.25 *) Ignition pulse voltage measured according EN 61347-2-1:2001 circuit figure 1 First action in case of malfunction (Disconnect from the mains before maintenance!) Description malfunction possible error cause trouble shooting Shutdown (over temperature) over temperature at internal components detected Take care for sufficient air circulation Check the distance between the devices (>=40mm) Check fans Press reset button >=3s for restart after cool down. Shutdown (End-of-lamp-life) Lamp reaches max. operating hours Replace lamp and press reset button >= 3s Shutdown (Ignition time limit) No successful ignition happens during complete ignition Check lamp and ignitor and press reset button >=3s for restart sequence Shutdown (mains low) Mains voltage low Ballast performs automatic restart as soon as the mains voltage has reached nominal range values again. ~ 6 ~

Safety warnings Do not attempt to handle or operate an electronic power supply (EPS) and ignitor before completely reading and understanding this notice. Contact THORN if you are uncertain of hazards associated with these devices. The Ballast and the ignitor produce starting voltages of up to 10 kv and electromagnetic radiation interference which are hazardous to personnel and sensitive instrumentation. Exercise appropriate care in the handling of high voltages. Do not touch any conductive parts during operation. Ballasts and fixtures / luminaires must be grounded in accordance with the National Electrical Code and any local regulations. Without proper fixture and ballast grounding, a shock hazard may exist due to the fixture becoming energized by an internal ballast failure. In addition, all ballasts have normal leakage current. When the ballast is properly grounded, the leakage current does not constitute a hazard. Ensure the units are isolated electrically / disconnected from the mains before maintenance / exchanging the lamp of the luminaire connected to the ballast / ignitor. Caution: The residual charge on the capacitors inside the ballast / ignitor can be a danger to life even if the units are disconnected from the mains. Please handle with care. Also be aware that the lamp / ballast module may still be hot, so exercise necessary caution to avoid burns. Both, electronic lamp ballast and ignitor must never be installed or operated in an explosive or volatile atmosphere. Never use the ballast or ignitor near flammable gases or liquids. See that there will be no moisture, dust or similar which could lead to short circuits or fire. Before using the ballast or ignitor in any kind of outdoor application you have to take additional measures and observe special requirements. If you are uncertain, contact THORN. No potential isolation is provided between line input and output. Accidentally grounding of an output terminal by direct contact or arcing to GND can damage the unit (no warranty replacement). The electronic ballast / ignitor has been designed to be installed in closed housings (switchgear cabinet). Mounting, wiring, maintenance and replacement if necessary has to be done by qualified personnel only. Due observation of the valid norms and safety regulations is mandatory when mounting and wiring the device. The user is responsible for ensuring that sufficient cooling is provided during operation. THORN does not assume liability for disregarding of this notice, incorrect use of the ballast and ignitor or disregarding of any legal requirements. This product is subject to technical changes without prior notice. CAUTION: Mains supply must be fused according to local safety regulations. THORN recommends 2 pole fuse (L+N). The appropriate fuse value can be calculated as: P lamp 1,5 * I V line fuse 1,2 * P lamp V line symbols CE conformity Attention: Device operates on high voltage!!! Attention: Device is getting hot during operation Special waste: After product life, device has to be disposed in special waste. Installation and servicing of electronic device only by qualified electrical employees. Disconnect electronic device from power supply before servicing. For indoor use only. Read attached instructions before use. ~ 7 ~ Revision: 22.09.2014