Bus Differential and Breaker Failure Relay. Advanced bus protection with built-in breaker failure detection

Similar documents
Bus Differential and Breaker Failure Relay. Advanced bus protection with built-in breaker failure detection

Bus Differential and Breaker Failure Relay. Advanced bus protection with built-in breaker failure detection

SEL-487B. A Powerful Solution for Busbar Differential Protection. Bus Differential and Breaker Failure Relay

Protection, Automation, and Control System. Combine subcycle line protection with complete substation bay control

Protection, Automation, and Bay Control System. Advanced feeder protection and complete substation bay control in one economical system

High-speed transformer differential protection for up to five terminals

SEL-487B Bus Differential Relay

A low-cost, economical solution for distribution feeder protection

Advanced Line Differential Protection, Automation, and Control System. Combine subcycle line protection with traveling-wave fault locating

Advanced distribution feeder solution with integrated protection, monitoring, and control

2 ms arc-flash protection and feeder relay in one platform

SEL Time-Domain Link (TiDL ) Technology

Protect induction and synchronous motors with one relay.

Maximize process uptime with the SEL-patented motor thermal model.

2 ms arc-flash protection and feeder relay in one platform

Built for speed, security, and simplicity

Real-Time Automation Controller (RTAC) Powerful, reliable, and secure multifunction controller

Lightweight and flexible recloser control for single-phase applications

Protect induction and synchronous motors with one relay

SEL-587Z High-Impedance Differential and Overcurrent Relay

One relay for safety and process continuity

Substation Automation Products. Bay control REC670/650 Relion 670 and 650 series

Modular Real-Time Automation Controller. Dependable control for harsh environments in a fully integrated, flexible platform

Protection, Monitoring, and Control System for Distribution Substations ALARM HISTORY SYSTEM COMM. On-Line Documentation TRANSFORMER 12 MW

SEL-421 Data Sheet. Protection, Automation, and Control System With Sampled Values. Major Features and Benefits

SEL-401 Data Sheet. Protection, Automation, and Control Merging Unit. Major Features and Benefits

Substation Automation Products. High impedance differential busbar protection REB650 Relion 650 series

NERC PRC-002 Recording Solutions

SEL-2730M. Reliably Control and Monitor Your Substation and Plant Networks. Managed 24-Port Ethernet Switch

Substation Automation Products. Line differential protection RED670 Relion 670 series

Comprehensive protection for large, medium, and small generators

RTAC. SEL Real-Time Automation Controller. Integrate station control, a web-based HMI, and logging through one reliable system.

SEL-311C-1 Transmission Protection System

DS Agile C264. Grid Solutions. Dual-bay Modular Substation Controller. Multi-function Controller. Automation and Control. Advanced Communication

MiCOM Agile P746. Grid Solutions. Key Benefits. Numerical Busbar Protection. A Combination of Speed, Security and Selectivity. About MiCOM P40 Agile

Substation Automation Products. Line distance protection REL670/650 Relion 670 and 650 series

Bus Bar Protection Relay B-PRO 4000

SEL Real-Time Automation Controller (RTAC)

GE Multilin 350 Feeder Protection Relay Specifications

Substation Automation Products. Transformer protection RET670/650 Relion 670 and 650 series

Deploying Digital Substations: Experience with a Digital Substation Pilot in North America. Harsh Vardhan, R Ramlachan GE Grid Solutions, USA

Powerful and flexible recloser control for many popular reclosers

SEL Protection, Automation, and Bay Control System

High-Speed Railroad Operations

SEL-2440 Discrete Programmable Automation Controller

Recloser Controller for feeder protection and automation siemens.com/distribution-automation

SEL-551/SEL-551C Overcurrent and Reclosing Relay

SEL-421-4, -5 Protection and Automation System

SEL-387E Current Differential and Voltage Protection Relay

U lity network. system Q sys. Interconnected P sys. P load Q load. P gen Q gen. Generator network

Substation Automation Products. Generator protection REG670/650 Relion 670 and 650 series

Distributed bus protection application in a platform for process bus deployment in the SMART SUBSTATION

Non-conventional instrument transformers Advanced GIS substations with IEC LE process bus

SEL-2414 Transformer Monitor

DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION. Application field

Trends in Station Bus and Process Bus Communications Via the Several IEC Protocols. Schweitzer Engineering Laboratories, Inc.

SEL-2030 Communications Processor

Designed, built, and tested for troublefree operation in extreme conditions

We will discuss two types of loss-of-potential (LOP) logic during this presentation:

SIPROTEC 7SC80 Feeder Protection and Automation Answers for infrastructure and cities.

KEY BENEFITS APPLICATIONS FEATURES

Relion 615 series Line Differential Protection and Control RED615 Ver. 2.0 Technical Presentation

SR489 SR489. Generator Management Relay. Economical protection, metering, and monitoring functions for small and medium sized generators.

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

DIGITAL RELAY OF PROTECTION AND AUTOMATION SERIES PC83 AND PC830

UR Universal Relay Series

Transformer Protection Relay

Jim McGhee, Utility Market Manager, RuggedCom Inc.

Content REF615 Technical Presentation

Relion 615 series Feeder Protection and Control REF615 Ver. 2.0 Technical Presentation

SEL-2411P Pump Automation Controller Data Sheet

SEL-351A Protection System Data Sheet

Siprotec 7ST61 / 7ST63

Busbar protection REB 670

Real-Time Automation Controllers (RTACs) Economical, multifunctional, compact real-time automation control

www. ElectricalPartManuals. com Protective Relays HIGHLIGHTS PROTECTIVE FUNCTIONS ixp-420 Transformer Protection Relay

MiCOM P122C Time-Overcurrent Protection

Merge physical security and cybersecurity for field operations.

SEL-351-5, -6, -7 Protection System Data Sheet

TWO-WINDING TRANSFORMER DIFFERENTIAL

Operator Controls and Reclosing Eliminate expensive control switches and wiring. Selectively reclose with synchronism and voltage checks.

Perfect protection smallest space

Relion 615 series Transformer Protection and Control RET615 Ver. 2.0 Technical Presentation

The SEL-700G Generator Protection Relay is the newest member of the SEL-700 series platform. It combines the protection features of the proven

IEEE 1588v2 Time Synchronization in Energy Automation Applications Case Studies from China

GE Power Management. UR F60 Feeder Management Relay An integrated feeder protection and metering solution

SIA-B. Overcurrent & Earth Fault Protection Relay for Secondary Distribution. Dual & Self Powered / Standard CTs. Main characteristics

SEL-400 Series TiDL Quick-Start Guide

Real-time visualization for detecting and solving power system challenges

Identify and understand the operation of common bus. After this presentation you will be able to: Identify common bus arrangements

g GE Power Management UR - The Universal Relay

Lecture 5 Substation Automation Systems. Course map

Type SDR reclosers plus controllers and type B-2 recloser bypass switch assembly usa.siemens.com/mediumvoltage

Function permission: yes/no. Operating range: 0.10 to 30 xin (step 0.01) Operating time: 0.02 to 300 s (step 0.01 s) Activation level 100%

Experience with a Digital Substation Pilot in North Ame rica

SEL-321 Data Sheet. Phase and Ground Distance Relay, Directional Overcurrent Relay, Fault Locator

F650 - More than Feeder Protection & Control. GE Consumer & Industrial Multilin

Merging unit ENMU. Manual

NPW800R RETROFITTING. Power and Volatge Protection Relay

750/760 Feeder Management Relay Instruction Manual

Transcription:

SEL-487B Bus Differential and Breaker Failure Relay Advanced bus protection with built-in breaker failure detection Protect busbars with up to 21 terminals using high-speed, low-impedance bus differential elements. Transform the way you modernize your substation with SEL Time-Domain Link (TiDL ) and Sampled Values (SV) technologies. Implement distributed bus protection and simplify commissioning using TiDL technology. Improve system testing and post-fault analysis with comprehensive monitoring, metering, and event recording capabilities.

Functional Overview Zone 1 52-1 89 52-2 89 89 52-6 52-52-4 52-5 50 50 50 50 50 50 50 51 51 51 51 51 51 51 50BF 50BF 50BF 50BF 50BF 50BF 50BF 87 Tie Breaker 89 89 87 89 89 Zone 2 27 59 PT ANSI Number/Acronyms and Functions 16 SEC Access Security (Serial, Ethernet) 27/59 Over-/Undervoltage 50 Overcurrent 50BF Breaker Failure Overcurrent 51 Time-Overcurrent 85 RIO SEL Mirrored Bits Communications 87 Current Differential DFR Event Reports HMI Operator Interface LGC Expanded SELogic Control Equations MET High-Accuracy Metering RTU Remote Terminal Unit SER Sequential Events Recorder 4 EIA-22 Zone 1 16 S EC 2 Ethernet 1 * SEL-487B-1 1 IRIG-B MET Zone 2 RTU SBM SER 85 RIO DFR HMI LGC SEL-487B Additional Functions SBM Station Battery Monitor SV IEC 61850-9-2 Sampled Values Technology* TiDL Time-Domain Link Technology* 1 Copper or fiber-optic *Optional feature SV subscriber relays have no analog input boards and instead receive voltages and current through Ethernet. 2 2 Ethernet Ethernet Station Bus Process Bus SEL-487B-2

Key Features Low-Impedance Bus Differential Protection The SEL-487B Bus Differential and Breaker Failure Relay protects bus systems with up to 21 terminals (21 CTs per relay, 6 CTs with a three-relay scheme), 6 protection zones, and independent check zones. To optimize protection security, each check zone supervises a designated phase in the system and a patented open-ct detection algorithm blocks potential misoperations during open- or shorted-ct conditions. Differential and directional current elements provide increased security and fast fault detection. You can also reduce protection costs with builtin breaker failure protection. Flexibility Implement different ratio CTs and nondedicated CTs with the SEL-487B. The flexibility built into the settings allows you to eliminate complex wiring by using CT ratios that differ by up to a factor of 10:1. Take advantage of the same CTs for differential protection, metering, backup relaying, and other functions. Monitoring and Metering The SEL-487B provides accurate, timely monitoring and metering of busbar, feeder, and substation signals. Terminal currents, breaker and disconnect positions, station dc voltage levels, and three-phase voltage are continuously monitored and updated. The relay also provides event reports and Sequential Events Recorder (SER) reports to simplify post-fault event analysis. Digital Secondary System Technologies Modernize your substation by applying SEL TiDL technology or SEL SV technology. Both of these digital secondary system solutions replace copper wires with fiber-optic cables to increase safety, reduce costs associated with using copper wires, and limit the impact of electromagnetic interference. TiDL is a simple and secure digital secondary system solution that is easy to implement, with no external time source or network engineering required. Apply the TiDL-enabled SEL-487B-1 in the control house with the SEL-2240 Axion TiDL node in the yard, which provides remote I/O, digitizes analog signals, and sends the signals over fiber-optic cables to the relay. SEL SV is the only digital secondary system solution in the world that combines protection in the merging unit with the flexibility of IEC 61850-9-2 to increase power system reliability. Apply the SEL-487B-2 with SEL SV technology to receive IEC 61850-9-2 SV data over fiber-optic cables from SEL merging units or other SV-compliant units. Distributed Bus Protection Apply the SEL-487B in a distributed bus protection scheme using TiDL technology. The system is easily scalable based on the number of bays in your system, and it does not require special communications ports or network engineering. TiDL s point-to-point architecture simplifies fiber-optic cable routing in the field and makes the commissioning process quick and easy.

Product Overview EIA-22 front serial port is quick and convenient for system setup and local access. Easy-to-use keypad aids simple navigation. Front-panel LEDs indicate custom alarms and provide fast and simple information to assist dispatchers and line crews with rapid power restoration. LCD automatically scrolls between custom displays. Programmable operator pushbuttons with user-configurable labels allow front-panel customization.

Communications protocols include FTP, Telnet, DNP LAN/WAN, the Parallel Redundancy Protocol (PRP), the IEEE 1588 Precision Time Protocol Version 2 (PTPv2),** and IEC 61850 Edition 2.* Choose from a horizontal panel-mount or rack-mount chassis and different size options. Use one front and three rear EIA-22 ports for Mirrored Bits communications, DNP, SCADA, and engineering access. 21 current and voltage channels accommodate different busbar configurations. Choose from power supply options such as 24 48 Vdc; 48 125 Vdc or 110 120 Vac; or 125 250 Vdc or 110 240 Vac. *Optional feature. **For PTPv2 implementation, Ports 5A and 5B must be ordered as an option.

Applications Differential Protection The SEL-487B includes six independent current differential elements, and each one provides: Fast operate times for all busbar faults. Security for external faults with heavy CT saturation. Security with subsidence current present. High sensitivity to busbar faults. Minimum delay for faults evolving from external to internal. CT Supervision For each zone, sensitive current differential elements detect differential current resulting from a differential element that is not well-balanced (i.e., has wrong CT ratios). If the conditions persist for longer than a userspecified delay, the element asserts an alarm that you can use to generate an external alarm and/or block the zone. Advanced Open-CT Detection Logic The patented open-ct detection logic improves the security of the current differential element. It ensures current differential bus zones will not misoperate due to terminals that cannot be properly measured. This advanced logic blocks differential element misoperations that occur under open- or shorted-ct conditions. The open-ct detection logic monitors the CT terminals in every bus zone to detect when a contributing CT fails. 20 100 50 10 Fault Inception 0 IO1 50 Current (amperes) 0 IO1 Current (amperes) 50 0 IO2 0 IO2 50 100 0 Internal Fault Detection (<1 cycle) 150 0 Internal Fault Detection No Differential Element Operation.05.10.15.20 Time (seconds) Differential element operates in less than one cycle for internal faults..05.10.15.20 Time (seconds) Differential element remains secure for external faults with heavy CT saturation.

Voltage Elements Supervise current differential tripping within the relay by using voltage elements. Three separate voltage elements consist of two levels of phase under- and overvoltage elements and two levels of negative- and zero-sequence overvoltage elements for each of the three analog voltage quantities measured. Integrated Overcurrent Protection Ten overcurrent curves are available for each current input. Each torque-controlled timeovercurrent element has two reset characteristics. There is also one level of instantaneous and definitetime elements available for each current input. CT Supervision Current Input I 01 Current Input I 21 I OP Differential Element Slope 2 Slope 1 External Fault Fault-Detection Logic I RT Internal Fault High-Security Operate Slope Standard Operate Slope Restraint Zone Trip Output When the relay directional elements detect an external fault, the relay enters a high-security mode and dynamically selects a higher slope for the differential elements, making them more secure during the fault. Breaker Failure Detection The SEL-487B includes complete breaker failure protection, with retrip capability for each terminal. Internal breaker failure is determined by predefined protection schemes that allow different types of trip signals and current flow conditions. You can set any terminal to either internal or external breaker failure protection; the inputs can provide individual or identical responses to each breaker failure condition. Current (amperes) 50 0 50 100 Subsidence Open-Phase Detection Traditional Overcurrent Dropout 150 0 0.02 0.04 0.06 0.08 0.1 0.12 0.14 0.16 0.18 0.2 Time (seconds); Offset: 0 High-speed open-pole detection logic detects open-pole conditions in fewer than 0.75 cycles to reduce breaker failure coordination times.

Dynamic Zone Configuration The SEL-487B dynamically assigns the input currents to the correct differential elements without the need for additional auxiliary relays. Connect the digital inputs from the busbar disconnect and breaker auxiliary contacts directly to the relay. SELogic control equations and zone selection logic will correctly assign the currents to the differential elements, even for complex bus arrangements (see top example). Note that the SEL-487B automatically includes the Zone 4 currents in Zone when disconnect switch DS is closed (see middle example). Three Independent Check Zones Supervise up to Six Differential Bus Zones In complex busbar layouts, the SEL-487B uses disconnect auxiliary contact status to define current differential bus zones and supervises these zones on a perphase basis with the independent check zone feature to prevent misoperation due to a discrepancy. The check zone feature: Allows you to create your own custom applications using powerful SELogic control equations. Provides secure supervision for bus zones. Supervises bus zones on a per-phase basis, independent of the terminal auxiliary disconnect status. Processes its logic independently of all bus zones. Fits a wide variety of applications and protection philosophies, with independent pickup and slope settings. Three-Relay Bus Protection Application For up to 21 Terminals You can configure a check zone for every phase, encompassing all terminals at the station (except bus coupler and sectionalizing breakers), independent of the disconnect auxiliary contact status. North Helium North Helium 52 Zone 1 DS2 Zone 2 East Boron Zone 1 DS1 Argon Lithium DS2 Zone 2 East Boron Argon Lithium Zone 1 52 TR 1 TR 2 DS1 Zone Silicon Krypton Zone Silicon Krypton 52 SEL-487B SEL-487B South DS Zone 4 West Sodium South DS Sodium Neon West Neon Result of ZONE Command: =>>ZONE BUS PROTECTION Rinadel Station Terminals in Protection Zone 1 HELIUM SILICON Bus Zones in Protection Zone 1 NORTH Terminals in Protection Zone 2 BORON ARGON LITHIUM Bus Zones in Protection Zone 2 EAST Terminals in Protection Zone SILICON KRYPTON Bus Zones in Protection Zone SOUTH Terminals in Protection Zone 4 SODIUM NEON Bus Zones in Protection Zone 4 WEST =>> Result of ZONE Command: =>>ZONE BUS PROTECTION Rinadel Station Terminals in Protection Zone 1 HELIUM SILICON Bus Zones in Protection Zone 1 NORTH Terminals in Protection Zone 2 BORON ARGON LITHIUM Bus Zones in Protection Zone 2 EAST Terminals in Protection Zone SILICON KRYPTON SODIUM NEON Bus Zones in Protection Zone SOUTH WEST =>> This example shows a single SEL-487B protecting a system with two -phase bus zones and increasing security by applying a check zone per phase. 52 FD 1 Zone 2 Check Zone 52 FD 2 52 FD

Automation and Control With 2 local control points, the SEL-487B helps eliminate traditional panel control switches. You can set, clear, or pulse local control points with the programmable frontpanel pushbuttons and display. Using SELogic control equations, you can program the local control points to implement your control scheme. The 2 remote control points help eliminate remote terminal unit (RTU)-to-relay wiring. Using serial port commands, you can set, clear, or pulse remote control points. You can also incorporate the remote control points into your control scheme via SELogic control equations and apply remote control points for SCADA-type control operations, such as trip and group selection. The SEL-487B control logic can replace the following: Traditional panel control switches RTU-to-relay wiring Traditional latching relays Traditional indicating panel lights Panel meters Simplified System Setup Develop SEL-487B settings and busbar configurations offline with acselerator QuickSet SEL-500 Software. The system automatically checks interrelated settings and highlights out-of-range settings. You can transfer settings created offline to the SEL-487B by using a PC communications link. The Graphical Logic Editor (GLE) in QuickSet simplifies the process of configuring your SEL-487B. With the GLE, you can view SELogic equations graphically, making it easier to document settings files for validation and commissioning. You can also convert existing SELogic control equations to easy-to-read diagrams and save diagrams with your QuickSet settings.

TiDL Technology In a TiDL solution, Axion TiDL nodes are placed in the yard close to the primary equipment to digitize discrete I/O signals and analog data and then transport them over a fiber-optic cable to the TiDL-enabled SEL-487B-1 in the control house. This innovative technology uses point-to-point connections and a nonroutable protocol, providing a simple and secure solution. Because it does not require an external time source or Ethernet switches, it is easy to implement with no network engineering required. TiDL combines the proven protection of the SEL-400 series relays with the modularity of the Axion, reducing training requirements and providing a scalable and flexible solution. It also provides built-in time synchronization and synchronous sampling, ensuring protection is available in the relay regardless of whether or not an external time signal is available. Substation Yard Fiber-Optic Cable Line 1 Line 2 Line SEL-2240 Axion SEL-2240 SEL-2240 Axion Axion SEL-2240 Axion SEL-2240 Axion SEL-2240 Axion SEL-2240 Axion SEL-2240 Axion Feeder 1 Feeder 2 Feeder Feeder 4 SEL-487B SEL-487B Control House High-speed distributed bus protection scheme using TiDL technology.

SEL-487B-1 With TiDL Technology LEDs indicate a valid configuration and successful commissioning. 4U chassis with horizontal mounting options (panel or rack) accommodates your application needs. LEDs indicate the connection status to a remote Axion TiDL node on a per-port basis. Eight 100 Mbps fiber-optic ports allow the TiDL-enabled relay to connect with eight remote Axion TiDL nodes and to receive remote analog and digital data. Commission button usage prompts the relay to communicate with the Axion TiDL nodes.

SEL SV Technology In an SEL SV solution, the SEL-487B-2 Relay (subscriber) in the control house receives digitized analog signals from an SV merging unit (publisher) in the yard via a fiberbased Ethernet network. The system uses precise time synchronization via IRIG-B or PTP. The SEL-487B-2 offers the traditional protection available in the SEL-487B-1 and can also receive SV data. Because all SEL SV devices are compliant with IEC 61850-9-2 and the UCA 61850-9-2LE guideline, they can be used with primary equipment that generates similar SV streams, with other manufacturers SV-compliant units, or with SEL merging units that offer built-in protection (such as the SEL-401 Merging Unit and the -7 Protection, Automation, and Control Merging Unit). SEL SV technology allows you to create a robust and flexible Ethernet-based point-to-multipoint network using tools such as software-defined networks or VLANs to fit your application needs. You can use the SEL-2740S Software-Defined Network Switch to provide centralized traffic engineering and improve Ethernet performance. The switch acts as a transparent PTP clock that supports the IEEE C7.28 power system profile, ensuring submicrosecond time synchronization of the end devices. Substation Yard Line 1 Merging Unit Line 2 Line Feeder 1 Feeder 2 Feeder Feeder 4 Fiber-Optic Cable Control House SEL-2488 GPS Clock SEL-2740S Ethernet Switch SEL-487B

SEL-487B-2 With SV Technology The 4U chassis has various mounting options to accommodate hardware needs. Select fiber-optic, copper, or mixed Ethernet with separate ports for SV data and engineering access. Choose from power supply options such as 24 48 Vdc; 48 125 Vdc or 110 120 Vac; or 125 250 Vdc or 110 240 Vac.

Accessibility and Communications Simplify System Testing and Post-Fault Analysis The SEL-487B event-reporting capabilities help improve understanding of even the most complex protective scheme operations. With the oscillographic and binary COMTRADE event reports and SER reporting in the SEL-487B, you can eliminate the need for external recorders or meters. View SER Records Gain a broad perspective of relay element operation with the SER in the SEL-487B. Items that trigger an SER entry are selectable and can include as many as 250 monitoring points, such as input/output change of state or element pickup/dropout. The relay SER stores the latest 1,000 events, which are available through the SER command. The latest 200 events are also viewable via the front-panel LCD. SEL-5601-2 synchrowave Event Software provides powerful analytic capabilities. Access Useful Information The SEL-487B makes it easy to access useful information when and where you need it. Metering quantities include primary and secondary voltage and current magnitudes as well as angles for each terminal. Zone information displays the primary or secondary current and voltage for each terminal. The polarity of each CT and the bus zones in each of the protective zones at the station are also included. Differential metering shows the operating and restraint currents for each zone as well as the reference current. Battery monitoring provides warning and alarm thresholds that you can monitor with the SEL-202 Communications Processor and the SEL-50 Real-Time Automation Controller (RTAC). You can also set up the system to send status messages to a local display, phones, or other devices. synchrowave Event displays individual operate and restraint currents for three different protection zones.

Integrate the SEL-487B With Ethernet Networks You can apply SEL-487B Relays with Ethernet directly to a local network or through an SEL communications processor. Use DNP LAN/WAN or Modbus TCP to quickly send information through your networks. Provide information to the right people for improved system performance. Transfer data with high-speed Ethernet for fast HMI updates and file uploads. Use popular Telnet applications for easy terminal communication with SEL relays and other devices. Combine IEC 61850 Edition 2 technology, an Ethernet network, and the SEL-487B for the fastest overall performance of IEC 61850 relays for substation automation and control. Access basic relay information on a standard Ethernet network with the built-in web server. You can view the relay status, SER reports, metering information, and settings. Web server access requires the relay password and is limited to read-only viewing of information. Simplify wiring and installation by receiving a time signal over existing Ethernet networks. The Simple Network Time Protocol (SNTP) makes a good backup to more accurate IRIG-B time synchronization, or you can use optional high-accuracy PTPv2 in place of IRIG-B. Support seamless failover for Ethernet communications with PRP, which allows communications network redundancy using two separate but identical LANs. Engineering Access SEL-2488 GPS Clock SEL-2740S SEL-50 SEL-451 Ethernet Switch Wide-Area Network SEL-487B Typical Ethernet network configuration.

SEL-487B Specifications General AC Current Inputs (21 total) AC Voltage Inputs ( total) Serial Ethernet 5 A nominal 1 A nominal 00 V L-N continuous, 600 Vac for 10 seconds 1 front-panel and rear-panel EIA-22 serial ports 00 57,600 bps TiDL Ports Fiber-optic ports: 8 SV Ports Precise-Time Input Processing Power Supply Operating Temperature Communications protocols include FTP, Telnet, DNP LAN/WAN, PRP, PTPv2, and IEC 61850 Edition 2 (optional). Choose from the following port options: Two 10/100BASE-T twisted-pair network ports Two 100BASE-FX fiber-optic network ports One 10/100BASE-T twisted-pair network port and one 100BASE-FX fiber-optic network port Range: ~2 km Data rate: 100 Mbps Choose from the following communications port options: Four 10/100BASE-T twisted-pair network ports Four 100BASE-FX fiber-optic network ports Two 10/100BASE-T twisted-pair network ports and two 100BASE-FX fiber-optic network ports Subscriber: As many as 4 SV data streams Data rate: 80 samples per cycle Demodulated IRIG-B time input and PTPv2 AC voltage and current inputs: 8,000 samples per second Protection and control processing: 12 times per power system cycle 24 48 Vdc 48 125 Vdc or 110 120 Vac 125 250 Vdc or 110 240 Vac 40 to +85 C ( 40 to +185 F) Note: LCD contrast is impaired for temperatures below 20 C ( 4 F) and above +70 C (+158 F). Making Electric Power Safer, More Reliable, and More Economical Tel: +1.509.2.1890 Email: info@selinc.com Web: www.selinc.com 2018 by Schweitzer Engineering Laboratories, Inc. PF0006 20181106