OPERATIONS MANUAL for V1000 VARIOMETER 31/10/06

Similar documents
SPRITE. Operations manual. VRM10 Digital Audio Variometer. Recorded alarm messages including undercarriage warning

LX 16-D Audio -Variometer system for gliders Pilots` Manual

Microair Avionics Pty Ltd Airport Drive Bundaberg Queensland 4670 Australia Tel: Fax:

The Packs Infotel. GSM Converter V2. Installation Manual V7

Microair Avionics Pty Ltd Airport Drive Bundaberg Queensland 4670 Australia Tel: Fax:

Remote units Hands free or telephone handset options available. Master to remote and remote to master calling

Helios user`s manual version 1.8

CLEVELAND CONTROLS MODEL 6650 DIGITAL MANOMETER INSTRUCTION MANUAL DM

CONTENTS Introduction 4 DTR overview 4 probes 5 functions 5 display 5 DTR operation 6 switching the DTR on or off 6 changing label 6 displaying

LX Helios. Speed to fly variometer, final glide calculator and simple navigation system with internal backup battery. User s manual (version 1.

Instruction Manual. CCP Supply Type 12AL SOUND & VIBRATION. Skovlytoften 33, 2840 Holte, Denmark

OPERATION MANUAL. auto range + type K Temp. optional Humidity, Light, Anemometer SOUND LEVEL METER Model : SL-4112

Humidity + Temp. + Dew Point Pocket size HUMIDITY METER. Model : HT-315

I. PANEL DESCRIPTION... 1

PTR. printing temperature recorder. User Manual. order code:

LED Wall Clock With Calendar and Temperature Display

DIGITAL MULTIMETER 4 1/2 digits, True RMS Model : DM-9027T

SOUND LEVEL METER DVM1351 INSTRUCTION MANUAL HANDLEIDING MANUEL D UTILISATEUR DVM1351 SOUND LEVEL METER 1

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) OPERATION MANUAL. Total System Manager

VSI200E Vertical Speed Indicator with Altitude Encoder

DMP-200 Digital Media Player Installation Manual

User's Guide. Vane Thermo-Anemometer Datalogger. Model Introduction

Contents 1 Warnings, Cautions, and Notes Description Features... 1

OPERATOR S MANUAL MODEL LS110 MINI-PBX SIMULATOR

Instruction Manual. G.R.A.S. 12AA 2-Channel Power Module with gain, filters and SysCheck generator. LI April 2015

DT1 Series 2.1 SINGLE CHANNEL TALKING DIALLER # N761. INSTALLATION MANUAL 3 rd EDITION.

DT6I Series 2 INTERROGATABLE 6 CHANNEL TALKING DIALLER. INSTALLATION MANUAL 2 nd EDITION.

FILM & VIDEO SETUP MANUAL

OPERATION MANUAL. separate probe, RS-232 SOUND LEVEL METER. Model : SL-4013

MicroTrans EQ Signal Processor. Operation & Maintenance Manual

Intercom User Manual v1.1

LED LIGHT METER OPERATION MANUAL. Model : LX-1148SD. SD card real time Data Recorder 10 Light Source select, Auto range 0 to 50,000 LUX

Prisma II Platform. Optoelectronics

User's Manual. VA893 Thermo Anemometer

T0046 PROFESSIONAL LAN CABLE TESTER USER GUIDE

DTM-321 REL HOLD T2 K-TYPE TEMP: 20 C 60 C 140 F C F HUMIDITY: %RH POWER-UP OPTIONS

SOUND LEVEL CALIBRATOR DVM1356 INSTRUCTION MANUAL HANDLEIDING MANUEL D UTILISATEUR DVM1356 SOUND LEVEL CALIBRATOR 1

DMP-200 Digital Media Player Installation Manual

Model IMP-22G2,H Low Cost Slave Clock Impulser Converts your slave clock to a working timepiece without modifying its original mechanism.

E101 - Strain Gauge Transducer Display Module. Contents

ATAPI TRAY DVD-ROM DRIVE UNIT

User's Guide. Heavy Duty Vane Thermo-Anemometer. Model

SOUND LEVEL METER OPERATION MANUAL. Model : SL Your purchase of this

IXIAN. Reads. Range / Accuracy. Calibration. 1, 2, 3 point remotely through PLC or directly on board.

RADIO-POWER INTERFACE

T1203 DME, ATC, LRA DISCRETE FUNCTION INTERFACE UNIT

DEVAR Inc. Model d-rtti User Manual

SC100 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. (407) Phone: Website:

GF-1. Introduction. 1 Features. +-10G Tilt Compensated dual range aviation G-force meter. Operating Manual English 1.00

USER MANUAL. IST channel speed calibrator

Model ST-618. Instruction Manual. Digital Thermo-Anemometer. Digital Measurement Metrology, Inc PRECISION IS OUR VISION

OPERATION MANUAL. Green power, Hybrid power Auto range, A/C weighting SOUND LEVEL METER. Model : SL-4113G. Your purchase of this

PA2000 SERIES. USER MANUAL Rev. P CELL PHONE ENTRY SYSTEM. Platinum Access Systems Inc.

Operating Manual. A 1717 Message Player IMPORTANT NOTE: Redback Proudly Made In Australia

Model 620A Maintenance and Calibration

V8/V80. Installation manual. Version 5.0

KNC Model 3719 Air Data Test Set

Lighting Energy Management Building Controls. LibRE Installation Guide

2 in 1 LAN Tester and Multimeter Model:

TECHNICAL PRODUCT DATASHEET

Introduction CLASS 1 LED PRODUCT

Vehicle DC-DC 150W User Guide DCA 7

DIGITAL PANEL METERS

OPERATION MANUAL. SD card real time datalogger 3 Channels TEMPERATURE DATA RECORDER. Model : MTM-380SD. Your purchase of this 3

Zone Pressure Touch (ZPT) Sensor with Attached Tube (-AT) - Low Pressure Range Unit Installation and Operation Instructions

Measure & Control Temperature & CO2 levels with analog & digital I/O

VISTA 12a / 48a TECHNICAL TRAINING. The Best in Security plus Everyday Convenience & Control

HI ma Simulator

The GF-2 is able to measure G-forces even if the instrument is not mounted exactly on the vertical axis of the aircraft.

SLI 15 Inverter Series Data Sheet 1500 Watt, 1U Compact Inverters

All necessary data input and manipulation can be done using the seven keys as shown below:

LS351 Desktop, single circuit unit, with XLR connectors (XLR3F, XLR3M loop-through). Local plug-in PSU option.

AC/DC MAGNETIC METER

Aristel Networks Pty Ltd. All Round Cabling Solutions NEOS3003-3G01. Operating Manual * NEOS G01

Electronic SD1, AS 8, ASR 14, ASR 20

Technical documentation NLS-3000 NAVIGATION LIGHT CONTROL PANEL

L-MBUS20/L-MBUS80. User Manual. M-Bus Level Converter. LOYTEC electronics GmbH

INSTRUCTION MANUAL FOR TQ-8800 TORQUE METER PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

Air velocity, Air flow, Type K/J thermometer Real time data logger, Data logger no., RS232 ANEMOMETER. Model : DAF2005MDL

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) SUITABLE FOR EXTERNAL DISTRIBUTION

HI ma Simulator

INSTRUCTIONS FOR MODEL 1000 DIGITAL PROCESS INDICATOR AND ALARM

Microprocessor based Temperature / CO2 Controller c/w 365 Day Time Switch & Modbus Communication.

Tone Alert and Ring Tone Amplifier

Fibre Modem - Single-mode

SoniChek MC. 99 Washington Street Melrose, MA Phone Toll Free TRIPLETT. Mini Sound Level Meter C Weighted

Digital Sound Level Meter with USB Model:

353 PRECISION ALTIMETER TESTER OPERATING INSTRUCTIONS

NEUROLOGIC RESEARCH CORPORATION MODEL 2500

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

Mounting Dimensions / Viewing 2 Mounting Options 3. Wiring Configuration 4. Quick Set up Procedure 5. Changing Intensity 6.

Operation Manual CX20 1/8 DIN Microcomputer Based Conductivity/Resistivity Controller

ADAPTERAPTER INSTRUCTIONS

User Manual Digi-Sense 12-Channel Benchtop Data Logging Thermocouple Thermometer

EnCell Battery Cell Monitor

Series ULT Ultrasonic Level Transmitter


TEMPERATURE CONTROLLER 2 HEAT/ 2 COOL with Digital Room Temperature Display. Made in Australia 100% Australian Owned Company

impact INSTRUCTIONS LiteTrek 4.0 Monolight lighting equipment and accessories

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

Transcription:

Rev1.6 OPERATIONS MANUAL for V1000 VARIOMETER Software version 3.1 INTRODUCTION This instrument is designed to satisfy a need for a product that utilises the most current technology to produce the best possible performance at the lowest possible cost. It accommodates and expands on all the most important functions of a standard Vario, ie. Audio, with internal speaker, current lift/sink rate, and includes the primary feature of an average display in the same small package. Simple installation with only power and TE connections required.

INTRODUCTION cont. Considerable effort has gone into developing an audio tone and pattern to convey to the pilot the maximum information without being intrusive or annoying. The result maximizes the pilots lookout time without the need for visual confirmation of the current climb rate. FEATURES * New in version 3.1 The instrument is centered on a custom LCD display. It incorporates two sections: a 270 deg. bar graph sweep display for visual representation of current climb rate, plus a 2.5 digit seven segment screen for current/average display (0-19.9). See fig 1. All functions are simply implemented by two front panel buttons. Normal operation consists of depressing the PWR switch for 1sec to select on/off. Audio volume is set by tapping + or -. Response time adjustable from 1 to 4.5 seconds from the front buttons. As all control functions are implemented with a microcomputer. A simple mode selection procedure can change a number of operating functions such as response speed and displayed values to suit the user. A communications port is provided for connection to a slave display for two seat aircraft including data output for external logging or navigational devices. Contact Tasman Instruments for details. * The sensing is via a temperature compensated pressure transducer which, for glider applications, would normally be connected to a TE. probe. NOTE: no flask is required. The instrument is in a standard aircraft pattern 2 1\4 inch circular face mount enclosure. Power is from an external 9-16V DC source and consumption is minimal (approx. 20mA depending on audio volume). Connections are made through rear panel modular or telephone type sockets via the cables supplied. * The instrument is fully functional on a 9 volt external battery supply. To maximise battery life and for optimal performance the maximum volume is restricted at lower voltages. There is still ample sound output for most installations at 9 volts supply. The low battery flag will be shown on the screen. * Automatic powerdown if the instrument is not flying. Tests of altitude change are recorded and tested after 2 hours** to decide if the instrument is flying. The PK312 power pack will not be depleted if the main power is removed without switching off the instrument. ** 1hour after ser 061031 2

Controls and display DISPLAY Current value display. 21 segments: selectable via front panel FUNCT/SELECT switches as +/- 10 FSD or +/-20.FSD. (see settings below). Digit display. As either average or current value. Note: this display section also used to indicate current MODE. (see operation below) and battery voltage. LOW BAT Illuminates if the voltage drops below 10.5 Volts, see below. units Knots or meters/second (V1000M) AUDIO Internal speaker. External speaker. Tasman Instruments SP190 available. Volume selection via front panel switches. average 20 sec fixed. memory All settings are retained in memory and are restored on power up. battery volts Read battery volts directly by pressing both buttons simultaneously. CONTROLS Buttons The two push button switches have multiple functions;- These are in two groups: CONNECTIONS power 9-16V DC polarity protected by internal fuse. 4P4C connector. PK312 automatic battery backup available. External display Remote display connection via 6P6C connector. TE probe Push on for 6 mm tube to TE probe. FIG 1 3

Operation Power; the RED button. To power instrument ON:- press and hold PWR for one second. The display shows all segments for a few seconds and a single BELL will be heard. Two BELL sounds would indicate a memory fault has occurred and default values will be used. To power instrument OFF:-press and hold PWR for approx two seconds.(the digit display counts from 2 down). Volume The volume has five settings; TAP + or - to increase or decrease. ( TAP is push and release) The display shows the current setting as: v1-5 for about 2 seconds after a key tap. * Note: v5 only available at 12 volts supply or above Battery Voltage Pressing both buttons simultaneously will display the battery volts. Note: the current value display and audio are suppressed. 4

Setup There are various MODES accessible via SETUP: They are entered via. the FUNCT or function button and modified by the SEL or select button. NOTE: No key press for 2 seconds will accept the value displayed and return to the normal display. FUNCT; the Yellow button. If this button is held down the audio is silent. If held down for more than one second a BELL will be heard and the current value display will be blank. The Digit display will now be a SETUP screen. Now release the key. Each TAP of the FUNCT key will cycle through the modes from 1-4. TAP FUNCT MODE 1 - average display: The screen will show F or SL F-(fast) The digit display will show the current value (see mode 3). SL-(slow) The digit display will show a 20 second average value TAP SEL to toggle. MODE 2 - full scale set: The screen will show 5 or 10 10- The current value display is +/-0-10 FSD. 5- The current value display is +/-0-5 FSD. Note: m/s units display 2.5 or 5.0 FSD TAP SEL to toggle Note: The average display will not change. TAP FUNCT MODE3 - response time: The screen will show r1-7. 1=1sec response time and it is incremented by 0.5 sec. ie. r3=2 second response TAP FUNCT MODE 4 - tone on sink on/off: The screen will show t1 t2 or t3 t1 tone on climb only. t2 tone on climb/ sink 2 knot deadband. t3 tone on climb/ sink no deadband. TAP SELECT to toggle. 5

This instrument is designed for sports aviation uses only. SPECIFICATIONS. SIZE: MOUNT: WEIGHT: H.62mm, W.62mm, D.85mm. STANDARD 2,1/4 INCH CUTOUT. 236 grams. POWER: 7.5-16VDC 20mA nom.(zero volume) ACCURACY: 3%.FSD RESOLUTION: 0.1 DISPLAY UNITS: ALTITUDE: OPERATING TEMP: KNOTS, meters/second -1000ft TO 33000ft. -10 TO 70 DEG. CENTIGRADE NON CONDENSING. OPTIONS. REPEATER DISPLAY. EXTERNAL SPEAKER. OTHER UNITS SUCH AS FT/SEC or ON REQUEST. For further information contact: Tasman Instruments 33 the Crescent Belgrave Hts. Victoria Australia 3160 Ph. 613 9754 7211 Fax. 613 9752 5002 Email: info@tasmaninstruments.com.au www.tasmaninstruments.com.au Revision History 10/03 1.4 Remove reference to flight computer> Include M/sec in specifications. 09/05 1.5 Include sink tone selection. 0506 1.6 Include ver 3.1 software 6