Liebert STS2/PDU, Static Transfer Switch 2/Power Distribution Unit. A Streamlined Package For Power Distribution And Source Switching

Similar documents
Liebert. STS2/PDU, Static Transfer Switch 2/ Power Distribution Unit A Streamlined Package For Power Distribution And Source Switching

Liebert Precision Power Center

Liebert Load Bus Sync Extender/Adapter for Dual Bus UPS

THE NEW SHAPE OF NETWORK POWER PROTECTION

Liebert APM UPS The Industry s Highest Energy Efficiency In A Row-Based, On-line UPS. AC Power For Business-Critical Continuity

Liebert THE NEW SHAPE OF NETWORK POWER PROTECTION. UPStation GXT 2U. An On-Line UPS With Proven Reliability,

Liebert Nfinity. A Powerful UPS Solution For Small To Medium Data Centers. AC Power For Business-Critical Continuity

Liebert NX. UPS For Small And Medium Business. AC Power For Business-Critical Continuity

Liebert LM Series. Continuous Protection For Your Business. Surge Protection For Business-Critical Continuity

SmartRow Intelligent, Integrated Infrastructure in a Self-Contained Line-Up. Solutions For Business-Critical Continuity

Liebert NX from 30 to 60 kw. AC Power for Business-Critical Continuity

SmartAisle Intelligent, Integrated Infrastructure Using Row-based Building Blocks. Solutions For Business-Critical Continuity

GXT 2U Configuration Program

Smart Solutions Intelligent, Integrated Infrastructure for the Data Center

Powering Change in the Data Center. A White Paper from the Experts in Business-Critical Continuity TM

Liebert DCW Family Chilled Water-Based High Density Cooling For The Data Center. Precision Cooling For Business-Critical Continuity

POWER AVAILABILITY 2U POD USER MANUAL. Power Output Distribution 120 Volt

Emerson Network Power Rack PDU Solutions Rack Power Distribution For Critical IT Equipment. AC Power For Business-Critical Continuity

Liebert IntelliSlot Relay Card

Liebert : The Right Cooling For IT Environments

Chloride CROSS Rack 16 A, 32 A and 63 A

APMTM UPS 30kW - 300kW The Compact Row-Based UPS With Flexpower Technology

Liebert MicroPOD 230V

POWER AVAILABILITY 2U POD USER MANUAL. Power Output Distribution 230 Volt

Liebert exm UPS kva/kw Efficient, Flexible Power Optimized for Midsize Applications FLEXIBLE. ECONOMICAL. INTELLIGENT

Liebert Maintenance Bypass Cabinet

Liebert APM. The Compact Row-Based UPS With FlexPower Technology TM. AC Power for Business-Critical Continuity

Liebert LM Series Surge Protective Device Continuous Protection For Your Business. Surge Protection For Business-Critical Continuity

Data Center Assessment Helps Keep Critical Equipment Operational. A White Paper from the Experts in Business-Critical Continuity TM

Liebert NX - Next Generation UPS for protecting your Business Critical Systems. AC Power Systems for Business-Critical Continuity

SERIES 610 LOAD BUS SYNC

Tel: AC Power for Business-Critical Continuity TM

Liebert APM. The Compact Row-Based UPS With Flexpower Technology TM. AC Power for Business-Critical Continuity

300 Series 330/320 Surge Protective Device Installation, Operation and Maintenance Manual

APMTM UPS 18kW - 90kW The Flexpower Technology for mission critical applications

Liebert NXr Series 15KVA to 90KVA (208V/220V) AC Power for Business-Critical Continuity

Two-Stage Power Distribution: An Essential Strategy to Future Proof the Data Center

Liebert. APM from 30 to 300 kw. The Compact Row Based UPS With FlexPower Technology

MONITORING INTELLIRACK USER MANUAL

Liebert Economizer Cooling Solutions Reduce Cooling Costs by up to 50% Without Compromising Reliability

SmartMod Intelligent, Integrated Infrastructure for the Data Center

Liebert. NXC from 10 to 200 kw. Compact and Reliable Power in a Fully Integrated Packaged Solution

Liebert. GXT3 5kVA-10kVA Compact UPS Systems For High Power Network Rack Applications

400 Series 460 Surge Protective Device Installation, Operation and Maintenance Manual

AC Power For Business-Critical Continuity. Liebert NX. UPS For Small And Medium Business

Liebert APM. The Compact, Row-Based UPS with Flexpower Technology 30kW - 300kW

Liebert GXT4 UPS, 5kVA-10kVA Intelligent, Reliable UPS Protection

Higher Availability: Self-diagnostics. Automatically tests unit electronics and batteries. Designed to simplify maintenance and troubleshooting.

Liebert GXT3 5kVA-10kVA UPS Compact UPS Systems For High Power Network Rack Applications. AC Power For Business-Critical Continuity

SmartCabinet Intelligent, Integrated Containment for IT Infrastructure

Configurable power distribution

Liebert APM The Compact Row-Based UPS With Flexpower Technology TM 30kW - 300kW. AC Power For Business-Critical Continuity

Liebert APM from kw. The Compact Row-Based UPS With FlexPower Technology TM

Liebert. EXS from 10 to 20 kw. Optimized and integrated three-phase UPS solution with high efficiency power protection

SmartRow Solution Intelligent, Integrated Infrastructure for the Data Center

Liebert APM The Compact Row-Based UPS With Flexpower Technology TM 30kW - 300kW. AC Power For Business-Critical Continuity

PHASE ONE Series 700: Uninterruptible Power Supply (UPS) Systems

Symmetra PX 48kW. Scalable from 16 to 48kW. Make the most of your energy TM. Modular, Scalable, High-Efficiency Power Protection for Data Centers

Modular, scalable, high-efficiency power protection for data centers

Securely Deliver Remote Monitoring and Service to Critical Systems. A White Paper from the Experts in Business-Critical Continuity TM

Hipulse-U UPS 80kVA - 500kVA Utmost Reliable Power Solution for Critical Business Applications

Liebert Series 610 UPS

Liebert NXC. 10 to 40kVA Compact and Reliable Power in a Fully Integrated Packaged Solution

Chloride Trinergy from 200 to 1200 kw

PowerPak 2 Power Distribution Unit. Flexible. Configurable. Intelligent. Safe.

Liebert NXr Series 30kVA to 160kVA. AC Power for Business-Critical Continuity TM

Liebert Series 610 UPS

Liebert. EXL UPS 800 and 1200kVA Single Module and Multi-Module Systems

Liebert NXC from 10 to 200 kva

Maximum Efficiency UPS Protection in an Intelligent, Low TCO Design Liebert exl UPS kVA, Single Module and Multi-Module Systems

ASCO 920 Remote Control (RC) Switches

Liebert NX, kva/kw UPS Maximum Efficiency in a transformer-free, High Efficiency, Scalable On-line UPS EFFICIENCY. AVAILABILITY.

AC Power Systems for Business-Critical Continuity. Liebert LTS. The Cornerstone of High-Availability Power Systems. Tel:

Modular, scalable, high-efficiency power protection for data centers

Symmetra PX. Symmetra PX 48kW Scalable from 16kW to 48kW. Modular, Scalable, High-Efficiency Power Protection for Data Centers

Liebert PDX. The Cooling Solution for Small and Medium Data Centers. Digital Scroll. Part Load. Competent Partner Efficiency

Common Mode Noise The Often Neglected Tenth Power Problem

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

PLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet

Liebert NX Series. 30kVA to 200kVA. AC Power for Business-Critical Continuity TM

MGE Galaxy /50/60/80/100/130 kva. The recommended power protection for all critical applications

SmartOnline 240/208/120V 8kVA 5.6kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, Split-Phase input, Bypass Switch

Liebert NXC from 10 to 60kVA

UPS Operating Modes: A Global Standard. A White Paper from the Experts in Business-Critical Continuity

MGE Galaxy /30/40/60/80/100/120 kva. The recommended power protection for all critical applications.

Protect It! 7-Outlet Surge Protector, 7-ft. Cord, 2520 Joules, Fax/Modem Protection, RJ11

SmartPro 120V 2.2kVA 1.6kW Line-Interactive UPS, Tower, Extended Run, Network Card Options, USB, DB9 Serial

Zenith Series MDU & RDU. Critical Power Distribution Units

Product brochure. Cyberex. Remote Power Panel (RPP) Power distribution system

SECTION SURGE PROTECTION DEVICES. A. Section includes Surge Protection Devices for low-voltage power, control, and communication equipment.

Liebert REAL POWER PROTECTION EVERYWHERE YOU REALLY NEED IT. Compact And Effective Desk Top And Network. Power Protection Including Battery Back-Up

UPS. centric Hot scalable modular 3-phase UPS Delivers 25 up to 200 kva/kw INFINITE POWER. Mission Critical Applications

Protect It! 7-Outlet Surge Protector, 6-ft. Cord, 1080 Joules, Fax/Modem Protection, RJ11

Precision Cooling for Business-Critical Continuity. Liebert HPC-S. Designed for the Efficient Cooling of Small Data Centers

PRODUCT BROCHURE. Cyberex Remote Power Panel (RPP) Power distribution system

SmartOnline SVTX Series 3-Phase 380/400/415V 30kVA 27kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

Liebert Series 610 UPS

MP7. Uninterruptible Power Supply

R E C T I F I E R I N V E R T E R C O N V E R T E R MP7

84 kw, Tier 3, Direct Expansion, 937 ft 2

Transcription:

Liebert STS2/PDU, Static Transfer Switch 2/Power Unit A Streamlined Package For Power And Source Switching

An All-In-One Power System With A Smaller Footprint And A Smaller Price Tag Liebert is making it easier to protect your critical equipment by giving your single cord loads the reliability of dual cord power or by providing added redundancy to your dual cord devices. With a single, space-saving unit, the Liebert Static Transfer Switch 2/Power Unit provides power distribution and automatic switching between two different AC power sources. Critical Power and Switching Made Easy This is why Liebert designed the STS2/PDU to bring you a distribution system that will close the power delivery loop in your critical facility. Liebert STS2/PDU offers the benefits of a custom-tailored power system, with the convenience and cost savings of a pre-packaged, factory-tested unit. Housed in a single, self-contained cabinet, it combines distribution, computer-grade grounding, isolation, and power monitoring, as well as dual-source switching, to provide the protection your vital computer or communications equipment demands. Available in 250 800 A capacity systems, the Liebert STS2/PDU offers flexible expansion capabilities to fit growing sites. A Proven System The packaged system approach of the Liebert STS2/ PDU is convenient and space-saving, reducing installation time and cost compared to a conventional approach using multiple interconnected components. The Liebert STS2/PDU is built on proven system designs used in thousands of installations. And unlike the one-of-a-kind, built-up distribution constructed at the site, it undergoes thorough factory testing as a complete system to assure reliable, consistent performance. Flexibility Compact single cabinet conserves valuable floorspace compared to non-packaged solutions. A choice of distribution options to fit site requirements Easily relocated when site needs change. Higher Availability Computer-grade grounding automatically establishes a single point ground to meet manufacturer and code requirements Fully compatible with the non-linear loads of modern computer systems and other electronic equipment. Standard on-unit monitoring and optional centralized monitoring capability provide continuous system visibility. Lowest Total Cost Of Ownership When applied as primary side switching, costs are lower due to requiring only one power distribution unit, a lower current due to 480V vs. 208V, and lower installation and wiring costs. Single cabinet design reduces installation time and cost. UL listed as complete system. Liebert STS2/PDU 600A 2

A Reliable Choice for Critical Equipment Protection A number of integral features allow Liebert STS2/PDU to provide a higher quality level of electrical power for your critical applications: Dual AC Input and automatic or manual switching capability boost the availability of reliable power to the protected single-source equipment. The main input breaker provides primary transformer overcurrent protection and a power disconnecting means. The Liebert packaged approach gives you an easily installed package with simplified hook-up and reduced installation time and cost. Front and side access allows greater location flexibility and smaller installed footprint. And since the power source is right in the room, it eliminates difficulties in establishing a proper ground. Built-in transformers eliminate harmonic neutral currents, which are possible with building wiring systems. Double-shielded isolation transformers located close to the load provide superior noise attenuation. Power : A single output breaker Or, up to four individually enclosed 42 pole output panelboards with panelboard main breaker and individual isolated neutral and ground bus bars distribute power to the sensitive load equipment. Or, I-Line Panelboard with up to 10 circuit breakers for distribution to loads, with separate isolated neutral and ground bus bars. Oversized neutral components safely withstand neutral currents of at least 1.73 times full load currents. 3

Designed From The Ground Up For Effective Power Protection Liebert STS2/PDU is designed with proven-effective Liebert components, combined into a package that greatly improves power quality while saving valuable floorspace. 4

Computer Grade Grounding Liebert STS2/PDU establishes a single point ground for the critical load. Power ground and computer ground points are identical, minimizing ground-loop currents and common mode disturbances. Short output cables maintain the integrity of the isolation and conditioning. Non-Linear Load Compatibility Liebert STS2/PDU is designed to accommodate moderate levels of harmonic currents. Where severe levels of harmonic currents are anticipated, K-Factor transformers for harmonic current cancellation are available. Secure And Circuit Identification On-Site Power Monitoring The integral power monitoring panel provides comprehensive metering and alarms for system power parameters. The color touch-screen LCD monitor has easy to understand pop-up menus, with a wealth of operational and diagnostic information. Monitoring features include: True RMS measurements Adjustable alarm thresholds Programmable custom alarms Battery-backed alarm memory Central Monitoring Interface panels are in the computer room, limiting access to authorized personnel only. Each breaker has an adjacent identification tag for rapid circuit ID. Liebert STS2/PDU is compatible with our Liebert SiteScan centralized monitoring systems, allowing single point monitoring and alarm of power conditions. In Dual Input Source for addition, an isolated RS-232 ASCII port is Single Input Loads provided for communication of monitored The internal solid-state bus transfer switch automatically parameters and alarm information to other or manually switches to the second AC source in the monitoring systems. Liebert OpenComms NIC event of a power failure, providing true dual source interface card can also be used to enable protection for single input equipment. cost-effective monitoring of a Liebert STS2/PDU by your facility or network monitoring system. True Internal Redundancy In addition to the redundancy provided by the dual internal transformers, the transfer switch itself has triple-redundant logic. Each DSP controller is capable of working independently, and each helps monitor the other two. If one malfunctions, the other two lock it out. Each controller has power feeds from both power supplies. A host of options enable you to design the Liebert packaged power system to your exact needs: Up to four, 42 pole panelboards for power distribution to critical equipment. I-Line panelboard with 10 circuit breakers for power distribution to the intended loads. Transient voltage surge suppression (TVSS) is available for increased protection from damaging voltage surges. Very short interconnecting wiring provides superior surge-clamping performance. K20 transformers safely withstand high harmonic currents associated with electronic loads without derating. 5

Easy Installation And Maintenance In A Compact Footprint As with all Liebert systems, the Liebert STS2/PDU is a marriage of form and Single Cabinet Design The smart design of Liebert STS2/PDU minimizes installation time while function. In addition to unbeatably it uses less floorspace. The single cabinet design of the Liebert STS2/PDU reliable power, the unit also saves is a factory wired and tested, field proven solution requiring less than two time with easy installation and routine thirds the space of traditional built-up systems. This design allows the maintenance while conserving space system to expand with your growth needs, or to easily relocate to a new with its compact package. space if protected equipment is moved to a new facility. High Efficiency Power In Far Less Space Traditional Built-Up System With Multiple Components INPUT A INPUT A 47.7 Sq. Ft. INPUT B INPUT B Static Transfer Switch Static Transfer Switch 18 ft 18 ft Single Cabinet Design Provides Greatly Reduced Footprint INPUT INPUT B A INPUT A 37.8 Sq. Ft. Static Transfer Switch 8 ft Trans former INPUT B Static Transfer Switch 8 ft Convenient, Fast Maintenance The Liebert STS2/PDU requires only front, top or side access for installation, operation and maintenance. Any area requiring routine maintenance is accessed through hinged or easily removed panels. The unit is constructed of replaceable subassemblies that can be easily changed by authorized personnel without exposure to high voltage. Nameplates are provided to identify protected devices, for error-free connection and maintenance. 6

Liebert STS2/PDU 250A Liebert STS2/PDU 600A Liebert STS2/PDU 800A Liebert Static Transfer Switch 2 / Power Unit Specifications Heat Uncrated Dimensions Uncrated Shipping Dimensions 1 Shipping Amp Input Output Output (WxDxH) Weight (WxDxH) Weight 1 Rating Voltage Voltage (KW) (inches) (mm) (lbs) (kg) (inches) (mm) (lbs) (kg) 250 208,380,400, 208 3.44 77x32x77 1956x813x1956 3393 1542 99x44x86 2515x1194x2184 3593 1633 415, 480 or 600 VAC 400 380,400, 208 5.66 73x49x77 1854x1245x1956 4608 2095 79x56x86 2007x1422x2184 4808 2185 415, 480 or 600 VAC 600 380,400, 208 8.57 73x49x77 1854x1245x1956 5692 2587 79x56x86 2007x1422x2184 5892 2678 415, 480 or 600 VAC 800 2 Module A 480 or 208 11.50 97x49x77 2464x1245x1956 8618 3917 48x56x86 1016x1422x2184 4184 1902 600 VAC Module B 64x56x86 1626x1422x2184 4463 2029 Note: 1 Shipping dimensions and weight include the pallet and packing material. Actual weights will vary depending on installed options. 2 The 800 A ships as 2 modules (shipping split). Operating Specifications Input Voltage: 208, 380, 400, 415, 480 or 600 VAC, +/- 10% Frequency: 50 or 60 Hz, +/- 5% Sense and transfer time: 4ms maximum Overload Capability: 125% for 10 minutes,150% for 2 minutes Operating Temperature: 0 to 40 C Standard Features Front and side accessible for installation and service Color touch-screen LCD interface eliminates mechanical pushbuttons Intuitive user interface with drop-down menus and dialog boxes Triple-redundant DSP digital logic Dual-redundant power supplies 100% rated, fuseless design Hot-swappable circuit breakers Flash memory enables firmware updates while supporting critical load CANBUS internal control wiring Rack-out control/power assembly on units up to 600A, to allow maintenance, service, or full replacement without disrupting the critical load Top and bottom cable entry Dual-lug installation bus UL listed Optional Features Full range of Liebert Open Comms hardware and software Programmable output relays for custom customer alarms and connections Customizable input relays allow alarms from other devices to be displayed on Liebert STS2/PDU display TVSS Keylock Switch Remote Source Selection Subfeed Breakers 7

Ensuring The High Availability Of Mission-Critical Data And Applications. Emerson Network Power, the global leader in enabling business-critical continuity, ensures network resiliency and adaptability through a family of technologies including Liebert power and cooling technologies that protect and support business-critical systems. Liebert solutions employ an adaptive architecture that responds to changes in criticality, density and capacity. Enterprises benefit from greater IT system availability, operational flexibility, and reduced capital equipment and operating costs. Liebert Corporation 1050 Dearborn Drive P.O. Box 29186 Columbus, Ohio 43229 800 877 9222 Phone (U.S. & Canada Only) 614 888 0246 Phone (Outside U.S.) 614 841 6022 FAX Via Leonardo Da Vinci 8 Zona Industriale Tognana 35028 Piove Di Sacco (PD) Italy 39 049 9719 111 Phone 39 049 5841 257 FAX Emerson Network Power Asia Pacific 7/F., Dah Sing Financial Centre 108 Gloucester Rd, Wanchai Hong Kong 852 25722201 Phone 852 28029250 FAX liebert.com 24 x 7 Tech Support 800 222 5877 Phone 614 841 6755 (outside U.S.) While every precaution has been taken to ensure accuracy and completeness in this literature, Liebert Corporation assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. 2016 Liebert Corporation. All rights reserved throughout the world. Specifications subject to change without notice. All names referred to are trademarks or registered trademarks of their respective owners. Liebert is a registered trademark of the Liebert Corporation. SL-20700 (R06/16) Printed in USA EmersonNetworkPower.com Business-Critical Continuity, Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. 2016 Emerson Electric Co.