Signet Pressure Transmitter

Similar documents
Signet Temperature Transmitter

Signet Flow Transmitter

Contents. 1. Installation

+GF+ SIGNET ph/orp Transmitter Instructions

SIGNET Level Transmitter

SIGNET ph/orp Transmitter

+GF+ SIGNET Conductivity/Resistivity Transmitter Instructions

Signet ph/orp Transmitter

Signet 5700 ph/orp Monitor - ph Instructions

Signet 5700 ph/orp Monitor - ORP Instructions

SIGNET 5700 ph/orp Monitor - ORP Instructions

Signet 5900 Salinity Monitor

Signet ph/orp Transmitter * *

+GF+ SIGNET 5800CR Conductivity/Resistivity Monitor Instructions

X Year mfg

FLOW MONITOR & TRANSMITTER

FLS M9.06. ph/orp MONITOR

FLS M9.06 PH/ORP MONITOR. safety instructions. packing List

Signet 5800CR Conductivity/Resistivity Monitor

+GF+ SIGNET 5900 Salinity Monitor Instructions

Signet 9900 Transmitter

Signet Conductivity/Resistivity Electrodes

Signet 2552 Metal Magmeter Flow Sensors

Table of Contents. 1 Introduction Introduction Front Panel Description Rear Panel Description 3

CDD Carbon Dioxide Transmitter

CDD4 Series Room CO2 Transmitter Installation Instructions

Conductivity Transmitters

Signet 2750 DryLoc ph/orp Sensor Electronics

Signet Conductivity/Resistivity Electrodes

Signet BC Batch Controller System

CDD4 Duct Carbon Dioxide Transmitter

Multi-Point Gas Detection and Control System

High Voltage DC Meter

Signet Conductivity Electrodes

HIGH-VOLTAGE DC METER

+GF+ SIGNET 9050CR Conductivity/Resistivity Controller

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

Multi-Point Gas Detection and Control System

Operation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data:

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)

Multi-Point Gas Detection and Control System

Table of Contents. General Information. Document Sure-Aire Flow Monitoring System. User and Service Manual WARNING CAUTION

OPERATION MANUAL MODEL TT-LP

PLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLATION!

DWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions.

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL

INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS

LAUREL ELECTRONICS, INC.

7511 / / / 711 / / 731 / Preset 27

INDICATOR FOR PROCESS CONTROL. Love Controls. LCI108J-0x INSTRUCTION MANUAL. EDITION: January Valid for models with software version P-1

DIGITAL PANEL THERMOMETER

ProSense DPM2 Series. Digital Panel Meter. User Manual. for process, temperature and resistance input signals. Models: DPM2-AT-HL DPM2-AT-2R-HL

dual-line 6-dIGIt process MeteR

DIGITAL PANEL THERMOMETER

Installation Instructions. Product Summary. Installation Guidelines. Tools and Equipment Needed. Table 1. Touchpad Power Usage

Carbon Monoxide (CO) Gas Detection and Control System

TC Type Range Conformity Error. J -210 C to +760 C (-347 F to F) ±0.09 C (±0.16 F) K -244 C to C (-408 F to F) ±0.1 C (±0.

Level-Lance Model 5400A

Installation Guide. Carbon Dioxide (CO 2. ) Detectors. General Information. Mounting WARNING CAUTION. SAE-1011/1012 Space Mount SAE-1011/1012/1062

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

Table of Contents. Introduction... 2 Description...2 Specifications...3 Installation.. 5 Calibration.. 6 General Maintenance...7

DIGITAL METERS Universal Analog Input Process Meter With Rate/Totalizer/Batch Control Features Instruction Manual

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications

Tempco Instruction Manual

Trident and Trident X2 Digital Process and Temperature Panel Meter

Analyzer/Controller. ph/orp HART. Model 54e ph/orp ESSENTIAL INSTRUCTIONS WARNINGS RISK OF ELECTRICAL SHOCK

5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL Fruitland Ave Los Angeles, CA SST7000 SST7100. Speed Switch / Transmitter

Installation Instructions

Pump-Down Controller MODEL mA Input Scalable 4-20mA Output Duplex Pump Alternation Hand-Off-Auto Controls Dual Run-time Meters

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

Operation and Maintenance Manual

PanelView Plus/VersaView CE Terminals and Display Modules

Operation Manual TX10 1/8 DIN Microcomputer Based ph/orp Controller

Iso DIN. User Manual. 1 channel Earth Fault Monitoring

Echotouch, EchoSpan & EchoSwitch Ultrasonic Liquid

Operating Manual RISH DPM Hz

TOXALERT MODEL AIR 2000

Installation Instructions

TC-9102 Series Surface Mount Temperature Controllers

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature

Series SD-3PB Digital THERMOSTAT + TIMER

DFI 7000 DIGITAL FORCE INDICATOR USER S GUIDE 1.0 INTRODUCTION 2.0 DESCRIPTION. 2.1 Configuration. 2.2 Specifications

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:

FLEX Ex Spring Clamp Terminal Base

SLIMCON-6 24V DC POWERED ISOLATING SIGNAL CONVERTER

/8 DIN Universal Process Indicator

HWS Series Wall Mount with Relay Setpoints, LCD, and Humidistat Control

MYRIAD LC1 LEVEL CONTROLLER INSTRUCTION MANUAL

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE

SX90 Process Controller

955 ebrik INSTALLATION MANUAL. Series ebrik ABSOLUTE PROCESS CONTROL KNOW WHERE YOU ARE... REGARDLESS LINEAR DISPLACEMENT TRANSDUCERS

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

Thermocouple Input Module Product Specifications and Installation Data

Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2

PD765 TRIDENT. Trident Series Process & Temperature Meters.

MODEL SW6000 & SM6100 CENELEC INSTRUCTIONS

Analog outputs Output 1 + 2: 0(4) 20 ma or 0 10 V. Configurable as - analog process value output - continuous controller output (PID action)

SERIES CMT CARBON MONOXIDE GAS TRANSMITTER

Transcription:

Signet 850 Pressure English *850.090* 850.090 Rev. H /06 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury. Contents. Installation. Specifi cations. Electrical Connections. Menu Functions Pressure Cal: 0.0 psi > Signet Pressure Relay Relay. Installation ProcessPro transmitters are available in two styles: panel mount and fi eld mount. The panel mount is supplied with the necessary hardware to install the transmitter. This manual includes complete panel mounting instructions. Field mounting requires one of two separate mounting kits. The 805 integral kit joins the sensor and instrument together into a single package. The 8050 Universal kit enables the transmitter to be installed virtually anywhere. Detailed instructions for integral mounting or other fi eld installation options are included with the 805 Integral kit or the 8050 Universal kit.. Panel Installation. The panel mount transmitter is designed for installation using a / DIN Punch. For manual panel cutout, an adhesive template is provided as an installation guide. Recommended clearance on all sides between instruments is inch.. Place gasket on instrument, and install in panel.. Slide mounting bracket over back of instrument until quickclips snap into latches on side of instrument.. To remove, secure instrument temporarily with tape from front or grip from rear of instrument. DO NOT RELEASE. Press quickclips outward and remove. gasket panel terminals mounting bracket 96 mm (.8 in.) 805 96 mm (.8 in.) Optional Rear Cover 9 mm (.6 in.) latch System Pwr Loop System Pwr Loop Output Output 7 6 5 Sensr Gnd (SHIELD) Sensr IN (RED) Sensr V (BLACK) 96 mm (.8 in.) FRONT VIEW Field Mount & Panel Mount mm (.7 in.) 65 mm (.5 in.) 07 mm (. in.) SIDE VIEW Field Mount mm (.6 in.) 56 mm (. in.) 97 mm (.8 in.) SIDE VIEW Panel Mount Panel Mount Installation Detail quickclips. Specifications General Compatibility: Signet 50 Pressure Sensors Accuracy: ±% of full scale Enclosure: Rating: NEMA X/IP65 front Case: PBT Panel case gasket: Neoprene Window: Polyurethane coated polycarbonate Keypad: Sealed key silicone rubber Weight: Approx. 5g ( oz.) Display: Alphanumeric x 6 LCD Update rate: second Contrast: User selected, 5 levels Environmental Operating temperature: 0 to 70 C ( to 58 F) Storage temperature: 5 to 80 C (5 to 76 F) Relative humidity: 0 to 95%, noncondensing Maximum altitude: 000 m (656 ft) Insulation category: II Pollution degree: Electrical Power: to VDC ±0%, regulated, 0 ma max current Current output: to 0 ma, isolated, fully adjustable and reversible Update rate: 00 ms Output accuracy: ±0.0 ma Maximum loop impedance: 50 Ω max. at V 5 Ω max. at 8 V 600 Ω max. at V Relay outputs ( sets mechanical SPDT contacts): Maximum voltage rating: 5 A @ 0 VDC, or 5 A @ 50 VAC resistive load Hi or Lo programmable with adjustable hysteresis Pulse programmable (maximum 00 pulses/minute) Standards and Approvals CE, UL listed Immunity: EN5008 Emissions: EN550 Class B Manufactured under ISO 900 and ISO 00

. Electrical Connections Caution: Failure to fully open terminal jaws before removing wire may permanently damage instrument. Wiring Procedure. Remove 0.5 0.65 in. (6 mm) of insulation from wire end.. Press the orange terminal lever downward with a small screwdriver to open terminal jaws.. Insert exposed (noninsulated) wire end in terminal hole until it bottoms out. The terminals will accomodate conductors from to AWG.. Release orange terminal lever to secure wire in place. Gently pull on each wire to ensure a good connection. Wiring Removal Procedure. Press the orange terminal lever downward with a small screwdriver to open terminal jaws.. When fully open, remove wire from terminal. Wiring Tips: Do not route sensor cable in conduit containing AC power wiring. Electrical noise may interfere with sensor signal. Routing sensor cable in grounded metal conduit will help prevent electrical noise and mechanical damage. Seal cable entry points to prevent moisture damage. Only one wire should be inserted into a terminal. Splice double wires outside the terminal. The cable length from the sensor to the transmitter must not exceed 00 ft. ( m) For best performance, ground the sensor SHIELD wire to a local earth ground at a point near the sensor. (Experiment with connecting the sensor shield wire to different local ground points to identify best signal quality.) and : Loop Power VDC ±0% system power and current loop output. Maximum loop impedance: 50Ω max. at V 5Ω max. at 8 V 600Ω max. at V 0 Relay (NO) : Digital sensor input See next page for more information. 9 Relay (COM) System Pwr Loop 8 Relay (NC) System Pwr Loop 7 Relay (NO) Sensr Gnd (WHITE) AUX Power 6 Relay (COM) Sensr IN (RED) AUX Power 5 Relay (NC) Sensr V (BLACK) and : AUXILIARY power Provides power for relay operation. 50: Relay Outputs Two sets mechanical SPDT contacts, programmable (see CALIBRATE menu) as: High or Low setpoint with adjustable hysteresis Proportional pulse output May be disabled (Off) if not used. Signet 850 Pressure

Relay Relay. Sensor Input Connections White (Sensr Gnd) Red (Sensr IN) Black (Sensr V) Signet 50 Pressure Sensors Pressure Cal: 0.0 psi > Signet Pressure 00 ft. ( m). System Power/Loop Connections Note: AUX (auxiliary) Power is required to power the Relays. Standalone application, no current loop used System Pwr Loop System Pwr Loop AUX Power AUX Power Power Supply VDC Connection to a PLC/Recorder, separate supply Connection to a PLC with builtin power supply System Pwr Loop System Pwr Loop AUX Power AUX Power PLC or Recorder Loop Input 0 ma Power Supply VDC System Pwr Loop System Pwr Loop AUX Power AUX Power PLC Loop Input 0 ma Power Supply VDC Internal PLC Connection Two transmitters connected to PLC/Recorder with separate power supply PLC or Recorder Channel 0 ma in Channel 0 ma in System Pwr Loop System Pwr Loop AUX Power AUX Power System Pwr Loop System Pwr Loop AUX Power AUX Power Power Supply VDC Signet 850 Pressure

. Relay Output The relay output can be used as a switch that responds when the process value moves above or below a setpoint. Hysteresis Process Low: Output triggers when process variable is less than the setpoint. The output will be deenergized when the process variable moves above the setpoint plus the hysteresis value. High: Output triggers when process variable is greater than the setpoint. The output will be deenergized when the process variable moves below the setpoint plus the hysteresis value. Low Setpoint Relay energized Relay deenergized Process Time Off The relays may be disabled if not being used. High Setpoint Hysteresis Time VIEW menu During normal operation, the ProcessPro displays the VIEW menu. When using the CALIBRATE or OPTIONS menus, the ProcessPro will return to the VIEW menu if no activity occurs for 0 minutes. To select the item you want displayed, press the UP or DOWN arrow keys. The items will scroll in a continuous loop. Changing the display selection does not interrupt system operations. No keycode is necessary to change display selection. Output settings cannot be edited from the VIEW menu. Pressure Cal: 0.0 psi > Signet Pressure Relay Relay View Menu Display Pressure: 60 psi Description Monitor the pressure input from the sensor. This is the permanent display. The displays below are temporary. The permanent display will return after 0 minutes Loop Output: Monitor the 0 ma Loop output..00 ma Last Cal 0600 Monitor date for scheduled maintenance or date of last calibration. Signet 850 Pressure

ProcessPro Editing Procedure: Step. Press and hold key: seconds to select the CALIBRATE menu 5 seconds to select the OPTIONS menu. Step. The Key Code is UPUPUPDOWN keys in sequence. After entering the Key Code, the display will show the fi rst item in the selected menu. Step. Scroll menu with UP or DOWN arrow keys. Step. Press RIGHT ARROW key to select menu item to be edited. The fi rst display element will begin fl ashing. Step 5. Press UP or DOWN keys to edit the flashing element. RIGHT ARROW key advances the fl ashing element. Step 6. Press key to save the new setting and return to Step. Notes on Step : The View Menu is normally displayed. The CALIBRATE and OPTIONS menus require a KEY CODE. Notes on Step : If no key is pressed for 5 minutes while display is showing "Enter Key Code", the display will return to the VIEW menu. Press & hold for access: CALIBRATE: Enter Key Code CALIBRATE: * Enter Key Code VIEW CALIBRATE s 5s CALIBRATE: ** Enter Key Code CALIBRATE: *** Enter Key Code OPTIONS Pressure Units: psi > First item in CALI BRATE menu Notes on Steps and : Refer to pages 6 and 7 for complete listing of menu items and their use. From the Step display, pressing the UP and DOWN keys simultaneously will return the display to the VIEW menu. If no key is pressed for 0 minutes, display will also return to the VIEW menu. Pressure Units: psi > Step Step : Finished Editing? Press the UP and DOWN keys simultaneously after saving the last setting to return to normal operation. Relay Setpnt: 0.00 psi > Step Notes on Steps 5 and 6: All output functions remain active during editing. Only the fl ashing element can be edited. RIGHT ARROW key advances the fl ashing element in a continuous loop. Edited value is effective immediately after pressing key. If no key is pressed for 0 minutes unit will restore the last saved value and return to step. Step 6 (pressing key) always returns you to Step. Repeat steps 6 until all editing is completed. Relay Setpnt: 0.00 psi Relay Setpnt: 00.00 psi Relay Setpnt: 00.00 psi Step 5 Step 5: Made an Error? Press the UP and DOWN keys simultaneously while any element is fl ashing. This will recall the last saved value of the item being edited and return you to Step. Step 6 Relay Setpnt: 09.00 psi Relay Setpnt: Saving Relay Setpnt: 09.00 psi > Signet 850 Pressure 5

Calibrate Menu Display (Factory settings shown) Pressure Units: psi > Description Select Pressure units for both input channels: psi, bar or kpa. Set: Pressure > Provides a maximum 5 psi offset to match 850 to external reference. Enter 999 to restore the original Factory calibration value. Changes to this setting will become effective when the display exits the Calibrate menu. Loop Range: psi 0.0 00.0 > Relay Mode Low > Relay Setpnt: 0.0 psi > Relay Hys: 5 > Last Cal 0600 > Check the 50 Sensor instructions for the range capability of your sensor. Be sure to modify this setting if you change the Pressure Units. Select the mode of operation for the relay: OFF, LOW or HIGH. The relay will be activated when the pressure reaches this value. Be sure to modify this setting if you change the Pressure Units. The relay will be deactivated at setpoint ± Hysteresis (depending on High or Low selection). Use this note pad to record important dates, such as annual recertifi cation or scheduled maintenance. 6 Signet 850 Pressure

Options Menu Display (Factory settings shown) Description Contrast: Decimal Averaging > ***.* > Off > Adjust the LCD contrast for best viewing. A setting of is lower contrast, 5 is higher. In general, select lower contrast if the display is in warmer ambient surroundings. Set the decimal to the best resolution for your application. The display will automatically scale down to this restriction. Select ****., ***.*, **.** or *.***. OFF provides the most instantaneous response to changes in pressure. It is the preferred option in systems where the measurement is very stable. Select LOW or HIGH averaging if your process experiences frequent or extreme fl uctuations in pressure. Loop Adjust:.00 ma > Loop Adjust: 0.00 ma > Adjust the minimum and maximum current output. The display value represents the precise current output. Adjustment limits:.80 ma <.00 ma > 5.00 ma 9.00 ma < 0.00 ma >.00 ma Use this setting to match the system output to any external device. Test Loop: Test Relay : > > Press UP and DOWN keys to manually order any output current value from.6 ma to.00 ma to test the output loop. Press UP and DOWN keys to manually toggle the relay state. Test Relay : > Press UP and DOWN keys to manually toggle the relay state. Signet 850 Pressure 7

Troubleshooting Display Condition Possible Causes Suggested Solutions "Check Sensor?" Sensor not wired properly. Sensor connected to 850 while power is on. Defective sensor. Correct sensor wiring. Recycle power with all sensors connected. Replace defective sensor. "Too much error CHECK SENSOR" The value entered in Set Pressure fi eld is greater than 5 psi deviation from sensor input. (The 850 allows a maximum of 5 psi calibration offset.) Confi rm calibration values. Remove sensor from installation, check 850 reading (should be zero). If necessary, Set Pressure to zero, reinstall sensor, then recalibrate. "Reset to Factory Calibration" Value in SET PRESSURE fi eld is 999. Entering "999" in this fi eld will remove all user calibration input and restore the factory values. Relay is always activated Hysteresis value too large. Reset hysteresis value in Calibrate menu. "SETUP READ ERROR Press Any Key" Memory fault occurred. Press any key to reload factory presets. Reprogram all setpoints. If this message appears again, replace the 850. Ordering Information Mfr. Part No. Code Description 850 59 000 0 Presure transmitter, Field mount 850P 59 000 0 Presure transmitter, Panel mount 850 59 000 0 Presure transmitter, Field mount with relays 850P 59 000 0 Presure transmitter, Panel mount with relays 850 59 000 05 Presure transmitter, Field mount with dual input/output 850P 59 000 06 Presure transmitter, Panel mount with dual input/output Accessories Mfr. Part No. Code Description 8050 59 000 8 Universal mounting kit 805 59 000 88 / in. Integral mounting kit 805 59 000 755 / in. NPT mount junction box 8050.95 59 000 86 Splashproof rear cover 8050.96 59 000 67 RC Filter kit (for relay use) 0000.596 59 000 6 Heavy duty wall mount bracket 5000.598 98 80 5 Surface Mount Bracket 9000.9 59 000 68 Liquid tight connector kit for rear cover (includes connectors) 9000.9 59 000 89 Liquid tight connector kit, NPT ( piece) 9000.9 59 000 8 Liquid tight connector kit, PG.5 ( piece) George Fischer Signet, Inc. 0 Aerojet Avenue, El Monte, CA 9788 U.S.A. Tel. (66) 57770 Fax (66) 57057 For Worldwide Sales and Service, visit our website: www.gfsignet.com Or call (in the U.S.): (800) 85090 850.090 Rev. H /06 English George Fischer Signet, Inc. 00 Printed in U.S.A. on recycled paper